A 16‐year‐old high school football player presented with 4 months of anterior knee pain and small, mobile, prepatellar “lumps” after falling onto an opponent's cleat. He reported knee pain primarily during knee flexion and direct pressure during squatting and kneeling. Knee radiographs were unremarkable. Ultrasonography revealed multiple, freely mobile, subcutaneous nodules of variable size and echogenicity in the prepatellar region. Analysis of magnetic resonance imaging suggested possible fat necrosis but was nondiagnostic. The patient opted for surgical exploration, at which time multiple, opalescent subcutaneous nodules were removed. Pathology was consistent with encapsulated fat necrosis. After surgery, his symptoms resolved, and he returned to sports without restrictions.
Ultrasound‐guided Ischial Bursa Injection: Technique and Positioning Considerations
ObjectivesTo 1) describe and validate an ultrasound‐guided ischial bursa injection technique in an unembalmed cadaveric model and 2) to compare the distance between the ischial tuberosity and the sciatic nerve in a hip neutral versus 90° flexed hip position in asymptomatic volunteers.DesignThe first part was a single‐blind prospective study. The second part was a prospective cohort study.SettingAn academic institution procedural skills laboratory and outpatient clinic.ParticipantsThe first part of the study involved 1 cadaveric specimen. The second part of the study involved 20 asymptomatic subjects. The mean age of the subjects was 28 years, and the mean (standard deviation) body mass index was 23.2 ± 2.8 kg/m2 (minimum, 18.3 kg/m2; maximum, 29.5 kg/m2).MethodsIn the first part of the study, a single operator completed bilateral ultrasound‐guided ischial bursa injections in an unembalmed cadaveric specimen by using diluted colored latex. In the second part of the study, ultrasound was used in 20 asymptomatic volunteer subjects (10 men and 10 women) to measure the distance from the lateral edge of the ischial tuberosity to the sciatic nerve.Main Outcome MeasurementsThe injections were graded for accuracy as follows: accurate (all injectate contained within the ischial bursa), accurate with overflow (injectate within the ischial bursa but also located in adjacent structures other than the needle track), or inaccurate (injectate not within the ischial bursa). The second part of the study measured the distance from the ischial tuberosity to the sciatic nerve with subjects in 2 different positions (prone and side lying with the tested hip flexed to 90°).ResultsPostinjection cadaveric dissections revealed that both ultrasound‐guided injections accurately placed liquid latex within the ischial bursae. There was no evidence of injury to surrounding neurovascular structures. Among asymptomatic volunteers, the average distance between the ischial tuberosity and the sciatic nerve increased from 28.4 mm (range, 20.5‐38.9 mm) in the neutral position to 41.9 mm (range, 30.9‐66.0 mm) with the hip flexed to 90° (average change, 13.5 mm away from the ischial tuberosity; P = .0001).ConclusionsUltrasound‐guided ischial bursa injections are technically feasible. Flexing the hip to 90° increases the distance between the ischial tuberosity and the sciatic nerve in asymptomatic volunteers, thus potentially resulting in a safer needle trajectory when ischial bursa injections are clinically indicated. Further investigation in clinical settings is warranted to validate these findings.
Evaluation of intracranial disorders in children by computerized transaxial tomography
Background: Invasive leg compartment testing may be performed to diagnose chronic exertional compartment syndrome. No prior study has assessed the accuracy of leg compartment needle tip access. Purpose: This study was undertaken to describe and determine the accuracy of palpation-guided and ultrasound-guided techniques for needle tip placement into the deep and superficial posterior leg compartments by a less experienced clinician and a more experienced clinician using a cadaveric model. Study Design: Controlled laboratory study. Methods: Twenty unembalmed adult lower limb cadaveric specimens were used for the study. Two investigators, a sports medicine fellow with 10 months of musculoskeletal ultrasound experience and a staff physiatrist with 3 years of musculoskeletal ultrasound experience, each performed 1 palpation-guided and 1 ultrasound-guided colored latex dye injection into the deep and superficial posterior leg compartments of each cadaveric specimen. A blinded investigator dissected the specimens and graded them for accuracy. Results: The accuracy rates of palpation-guided (accuracy rate, 90%; 95% confidence interval [CI], 76%-97%) and ultrasound-guided (accuracy rate, 88%; 95% CI, 73%-95%) deep posterior compartment injections were statistically equivalent ( P = 1.000). All 80 injections performed into the superficial posterior compartment were accurate (accuracy rate, 100%; 95% CI, 89%-100%). The accuracy of the less experienced investigator (total injection accuracy rate, 88%; 95% CI, 73%-95%) and the more experienced investigator (total injection accuracy rate, 90%; 95% CI, 76%-97%) were not significantly different ( P = 1.000). Conclusion: Needle tip placement into the deep and superficial posterior leg compartments is relatively accurate with palpation guidance regardless of level of experience, and does not improve with the use of ultrasound guidance. Clinical Relevance: Ultrasound guidance does not appear to be indicated for routine deep or superficial posterior leg compartment pressure testing. However, this does not preclude the need for ultrasound guidance in selected clinical scenarios.
Refining Rehabilitation With Proprioception Training
Background Golf provides an opportunity for relatively low-impact exercise for nearly all age groups and is considered a recommended activity for patients after total knee arthroplasty. Hypothesis We hypothesized that total knee arthroplasty would afford patients increased ability to participate in and enjoy golf, allowing a large percentage of these patients to walk the golf course. Study Design Case series; Level of evidence, 4. Methods Surveys were sent to 151 golfers who had undergone primary total knee arthroplasty from 1995 to 2000. The detailed survey included 33 questions specific to the patients’ golf performance, enjoyment of golf, frequency of participation, timing of return to play, presence of pain, use of a cart, and related golf-specific issues. Results We received and evaluated 93 responses (62%). Fifty-seven percent reported they had returned to golf within 6 months after total knee arthroplasty. Eighty-one percent of respondents reported golfing as frequently, or more frequently, than before knee replacement. Notably, golfers reported less pain while golfing after total knee arthroplasty than before (13% vs 83%; P < .0001), and 94% of respondents reported currently enjoying golf as much as or more than before surgery. Twenty-eight percent of respondents stated that they walked the course, rather than using a motorized golf cart, before surgery, while only 14% walked the course after surgery ( P = .02). Conclusion In this population of golfers, total knee arthroplasty reliably relieved pain that had been previously experienced while golfing, and increased or maintained this group’s enjoyment of playing golf. However, 86% of these patients reported using a cart while golfing. Further patient education is needed regarding the potential health benefits of walking during golf after total knee arthroplasty.