Citations

Clear

137 citation(s) found for "Fatemi, Mostafa".

Shear wave elastography of the median nerve: A mechanical study
Schrier, Verena J.M.M. , Lin, Jason , Gregory, Adriana , Thoreson, Andrew R. , Amadio, Peter C. , Fatemi, Mostafa , Fatemi, Mostafa , Alizad, Azra

Mayo Clinic

Muscle & Nerve | March 14, 2020 | Volume: 61 | Issue: 6 | Pages: 826-833

10.1002/mus.26863 | PMID 32170959 Get It

AbstractBackgroundShear wave elastography (SWE) shows promise in peripheral neuropathy evaluation but has potential limitations due to tissue size and heterogeneity. We tested SWE sensitivity to elasticity change and the effect of probe position in a median nerve cadaver model.MethodsTen specimens were used to measure median nerve elasticity under increasing loads using SWE and indentation. Measurements were compared using repeated‐measures analysis of variance.ResultsIndentation and SWE‐based longitudinal nerve elasticity increased with tensile loading (P< .01), showing a similar relationship. Acquisition in a transverse plane showed lower values compared with longitudinal measurements, mostly under higher loads (P= .03), as did postdissection elasticity (P= .02). Elasticity did not change when measured proximal to the carpal tunnel.ConclusionsLongitudinal SWE is sensitive to changes in median nerve elasticity. Measuring elasticity of peripheral nerves noninvasively could elucidate intra‐neural pathology related to compression neuropathies, and proof to be of added value as a diagnostic or prognostic tool.
Ultrasonic evaluation of bone health in patients
Fatemi, Mostafa , Alizad, Azra

Mayo Clinic

The Journal of the Acoustical Society of America | November 13, 2019 | Volume: 146 | Issue: 4_Supplement | Pages: 2863-2863

10.1121/1.5136934 Get It

Noninvasive and quantitative methods for evaluation of bone health are of interest in clinical practice. Two areas of particular interest include evaluation of bone fracture healing and assessment of osteoporosis. Determination of bone healing time impacts patient health and the associated economic factors. Furthermore, assessment of bone quality in patients at risk for osteoporosis/osteopenia can benefit a large number of patients in the upper age group. Here, we present a quantitative method for the evaluation of bone integrity and quality. This method is based on analyzing the acoustic response of bone to stimulation provided by the acoustic radiation force of ultrasound. Longitudinal studies for bone healing assessment were conducted on a group of patients with clavicle fracture. The contralateral intact bone was used as a control for each patient. Bone healing assessments were performed using mode decomposition. It was found that the healing process could be detected in 80% of fractured bones. A separate study was conducted to differentiate osteoporotic/osteopenic from normal bones. A total of 27 adult volunteers in two groups of healthy and those with osteopenia/osteoporosis were tested. Results of the test on tibia showed that osteoporosis/osteopenia bones could be differentiated from the healthy ones (&lt;2 × 10-5).
Evaluation of bone fracture healing in children using acoustic radiation force: Initial in vivo results
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Denis, Max , Milbrandt, Todd A. , Kumar, Viksit , Larson, A. Noelle , Fatemi, Mostafa , Alizad, Azra

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1893-1893

10.1121/1.5101860 Get It

Vibrational characteristics of the bone are directly dependent on bone’s physical properties. In this paper, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on acoustic radiation force of ultrasound for bone characterization in patients with fracture. In this method, we excite the clavicle and ulna by an ultrasound radiation force (URF) pulse. The URF pulse induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. To further separate different vibration characteristics, we adopt a variational mode decomposition (VMD) technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, which allows analyzing the acoustic signals in terms of their constitutive components. We conducted a prospective study that included a total of 15 patients, 12 with clavicle fractures and 3 with ulna fractures. The contralateral intact bones were used as control. Statistical analysis demonstrated that fracture bones can be differentiated from intact bone with a detection probability of 80%. Also, we introduce a “healing factor” that quantifies the progress of healing in clavicle bones. Statistical analysis showed that healing factor can track the progress of healing in clavicle in 80% of fractures.
Repeatability of linear and nonlinear quantitative compression elastography in the breast
Barbone, Paul E. , Gendin, Daniel , Wang, Yuqi , Nayak, Rohit , Oberai, Assad A. , Hall, Timothy J. , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1891-1891

10.1121/1.5101854 Get It

Compression elastography allows the precise measurement of large deformations of soft tissue in vivo. From a measured large deformation, an inverse problem for both the linear and nonlinear elastic moduli distributions can be solved. As part of a larger clinical study to evaluate NEMs in breast cancer, we evaluate the repeatability of linear and nonlinear modulus maps from repeat measurements. Within the cohort of 31 subjects scanned to date, several had repeated scans. These repeated scans were processed to evaluate NEM repeatability. In vivo data were acquired by a custom, digitally controlled, uniaxial compression device with force feedback. RF-data were acquired using plane wave imaging, at a frame-rate of 200 Hz, with a ramp-and-hold compressive force of 8N, applied at 8 N/s. A two-dimensional (2D) block-matching algorithm was used to obtain sample-level displacement fields which were then tracked at subsample resolution using 2D cross correlation. Linear and nonlinear elasticity parameters in the Blatz model of tissue elasticity are estimated using iterative optimization. Repeatability between both modes and elastic modulus maps is measured and compared. Preliminary results indicate that when images are acquired in the same region of tissue, the modulus maps are consistent. [Work supported by NIH R01CA195527.]
Comparisons of inverse and forward problem approaches to elastography
Ghavami, Siavash , Aquino, Wilkins , Adabi, Saba , Babaniyi, Olalekan A. , Alizad, Azra , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1891-1891

10.1121/1.5101853 Get It

We present a full-wave inversion approach with total variation regularization for elastography. The proposed method is based on the minimization of an error in constitutive equations functional augmented with a least squares data misfit term referred to as MECE for “modified error in constitutive equations.” The main theme of this paper is to demonstrate several key strengths of the proposed method on experimental data. In addition, some illustrative examples are provided where the proposed method is compared with a common shear wave elastography (SWE) approach. To this end, ultrasonically tracked displacement data from an acoustic radiation force (ARF) pulse are used in different phantoms including phantom with layered inclusion and triangle inclusion. The results indicate that the MECE approach can produce accurate shear modulus reconstructions in comparison with SWE, especially around the sharp edges in the layered and triangle inclusions. We compare shear modulus reconstruction using MECE and SWE with original inclusion shapes using two-dimensional normalized zero mean cross correlation, edge preservation index and dice coefficient similarity index. [Work supported by NIH Grant R01 CA174723.]
Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results
Kim, Bae-Hyung , Fatemi, Mostafa , Kumar, Viksit, Fatemi, Mostafa , Kumar, Viksit , Alizad, Azra

Mayo Clinic

The Journal of the Acoustical Society of America | March 18, 2019 | Volume: 145 | Issue: 3 | Pages: EL236-EL242

10.1121/1.5094337 | PMID 31067972 Get It

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.
Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Bayat, Mahdi , Denis, Max , Milbrand, Todd A., Larson, A. Noelle , Fatemi, Mostafa , Alizad, Azra , Kumar, Viksit, Larson, A Noelle , Alizad, Azra , Fatemi, Mostafa , Kumar, Viksit

Mayo Clinic

Sensors | February 25, 2019 | Volume: 19 | Issue: 4 | Pages: 955

10.3390/s19040955 | PMID 30813465 Get It

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a “healing factor” to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.
Acoustic navigation of intramyocardial injection needle catheter using color doppler echocardiography
Katayama, Minako , Zarbatany, David, Vaitkus, Veronica V. , Fortuin, David, Fatemi, Mostafa , Bëlohlávek, Marek , Fatemi, Mostafa , Kumar, Viksit

Mayo Clinic

2018 IEEE International Ultrasonics Symposium (IUS) | February 21, 2019 | Volume: No volume available | Issue: No issue available | Pages: 1-3

10.1109/ultsym.2018.8579717 Get It

Non-Local Based Denoising Framework for In Vivo Contrast-Free Ultrasound Microvessel Imaging
Ghavami, Siavash , Fatemi, Mostafa , Alizad, Azra , Adabi, Saba, Fatemi, Mostafa , Alizad, Azra , Adabi, Saba

Mayo Clinic

Sensors | January 11, 2019 | Volume: 19 | Issue: 2 | Pages: 245

10.3390/s19020245 | PMID 30634614 Get It

Vascular networks can provide invaluable information about tumor angiogenesis. Ultrafast Doppler imaging enables ultrasound to image microvessels by applying tissue clutter filtering methods on the spatio-temporal data obtained from plane-wave imaging. However, the resultant vessel images suffer from background noise that degrades image quality and restricts vessel visibilities. In this paper, we addressed microvessel visualization and the associated noise problem in the power Doppler images with the goal of achieving enhanced vessel-background separation. We proposed a combination of patch-based non-local mean filtering and top-hat morphological filtering to improve vessel outline and background noise suppression. We tested the proposed method on a flow phantom, as well as in vivo breast lesions, thyroid nodules, and pathologic liver from human subjects. The proposed non-local-based framework provided a remarkable gain of more than 15 dB, on average, in terms of contrast-to-noise and signal-to-noise ratios. In addition to improving visualization of microvessels, the proposed method provided high quality images suitable for microvessel morphology quantification that may be used for diagnostic applications.
A Real‐time Color Doppler Marker for Echocardiographic Guidance of an Acoustically Active Extracorporeal Membrane Oxygenation Cannula
Bëlohlávek, Marek , Vaitkus, Veronica V. , Fatemi, Mostafa , Grabham, Jason, Sandweiss, Bryan M., Katayama, Minako , Kumar, Viksit, Fatemi, Mostafa , Kumar, Viksit

Mayo Clinic

Journal of Ultrasound in Medicine | November 12, 2018 | Volume: 38 | Issue: 7 | Pages: 1875-1885

10.1002/jum.14859 | PMID 30419612 Get It

B‐mode ultrasound imaging guidance of cannulas can be compromised by noise, artifacts, and echogenicity that is not distinctive from that of surrounding anatomy. We have modified a venovenous extracorporeal membrane oxygenation cannula by embedding piezoelectric crystals into each of its 3 blood flow ports. Each vibrating crystal acoustically interacts with a Doppler imaging signal and produces an instantaneous color marker. The aim of this study was to compare identification of the extracorporeal membrane oxygenation cannula ports by B‐mode imaging versus the color Doppler marker. Unlike B‐mode imaging, the color Doppler marker identified the corresponding port even in highly challenging closed‐chest scans in anesthetized pigs. The method could improve guidance accuracy of cannulas by ultrasound scans.