Citations 3

Experimental Study of Aperiodic Plane Wave Imaging for Ultrafast 3-D Ultrasound Imaging

IEEE Transactions on Biomedical Engineering | February 18, 2022 | Volume: 69 | Issue: 8 | Pages: 2679-2690

10.1109/tbme.2022.3152212 | PMID 35180073

Fully Automated Segmentation of Bladder Sac and Measurement of Detrusor Wall Thickness from Transabdominal Ultrasound Images

Sensors | July 28, 2020 | Volume: 20 | Issue: 15 | Pages: 4175

10.3390/s20154175 | PMID 32727146

Ultrasound measurements of detrusor muscle thickness have been proposed as a diagnostic biomarker in patients with bladder overactivity and voiding dysfunction. In this study, we present an approach based on deep learning (DL) and dynamic programming (DP) to segment the bladder sac and measure the detrusor muscle thickness from transabdominal 2D B-mode ultrasound images. To assess the performance of our method, we compared the results of automated methods to the manually obtained reference bladder segmentations and wall thickness measurements of 80 images obtained from 11 volunteers. It takes less than a second to segment the bladder from a 2D B-mode image for the DL method. The average Dice index for the bladder segmentation is 0.93 ± 0.04 mm, and the average root-mean-square-error and standard deviation for wall thickness measurement are 0.7 ± 0.2 mm, which is comparable to the manual ground truth. The proposed fully automated and fast method could be a useful tool for segmentation and wall thickness measurement of the bladder from transabdominal B-mode images. The computation speed and accuracy of the proposed method will enable adaptive adjustment of the ultrasound focus point, and continuous assessment of the bladder wall during the filling and voiding process of the bladder.
Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results

The Journal of the Acoustical Society of America | March 18, 2019 | Volume: 145 | Issue: 3 | Pages: EL236-EL242

10.1121/1.5094337 | PMID 31067972

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.