Citations 9

Evaluation of bone fracture healing in children using acoustic radiation force: Initial in vivo results

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1893-1893

10.1121/1.5101860

Vibrational characteristics of the bone are directly dependent on bone’s physical properties. In this paper, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on acoustic radiation force of ultrasound for bone characterization in patients with fracture. In this method, we excite the clavicle and ulna by an ultrasound radiation force (URF) pulse. The URF pulse induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. To further separate different vibration characteristics, we adopt a variational mode decomposition (VMD) technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, which allows analyzing the acoustic signals in terms of their constitutive components. We conducted a prospective study that included a total of 15 patients, 12 with clavicle fractures and 3 with ulna fractures. The contralateral intact bones were used as control. Statistical analysis demonstrated that fracture bones can be differentiated from intact bone with a detection probability of 80%. Also, we introduce a “healing factor” that quantifies the progress of healing in clavicle bones. Statistical analysis showed that healing factor can track the progress of healing in clavicle in 80% of fractures.
Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results

The Journal of the Acoustical Society of America | March 18, 2019 | Volume: 145 | Issue: 3 | Pages: EL236-EL242

10.1121/1.5094337 | PMID 31067972

Sparse array (SA) is an approach to reduce the number of system channels. However, SA suffers from grating lobe (GL) artefacts due to the sparsity of array aperture resulting in degradation of the ultrasound image quality. Based on a given or known data sets of radio frequency (RF) echo acquired from active elements of an array, RF echo data in unknown and/or inactive elements of array can be created virtually and used to suppress the GL artefact in SA. This letter presents gap-filling (GF) approaches to generate channel data, which are not physically acquired. It is demonstrated that the proposed GF technique can reduce the artefacts of SA by filling the gaps in the array aperture. Simulation results show that the GF technique can suppress the GL level of SA by up to 16 dB. Also, the GF technique can improve the image quality of fully sampled arrays with small number of active elements.
Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study

Sensors | February 25, 2019 | Volume: 19 | Issue: 4 | Pages: 955

10.3390/s19040955 | PMID 30813465

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a “healing factor” to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.
Acoustic navigation of intramyocardial injection needle catheter using color doppler echocardiography

2018 IEEE International Ultrasonics Symposium (IUS) | February 21, 2019 | Volume: No volume available | Issue: No issue available | Pages: 1-3

10.1109/ultsym.2018.8579717

A Real‐time Color Doppler Marker for Echocardiographic Guidance of an Acoustically Active Extracorporeal Membrane Oxygenation Cannula

Journal of Ultrasound in Medicine | November 12, 2018 | Volume: 38 | Issue: 7 | Pages: 1875-1885

10.1002/jum.14859 | PMID 30419612

B‐mode ultrasound imaging guidance of cannulas can be compromised by noise, artifacts, and echogenicity that is not distinctive from that of surrounding anatomy. We have modified a venovenous extracorporeal membrane oxygenation cannula by embedding piezoelectric crystals into each of its 3 blood flow ports. Each vibrating crystal acoustically interacts with a Doppler imaging signal and produces an instantaneous color marker. The aim of this study was to compare identification of the extracorporeal membrane oxygenation cannula ports by B‐mode imaging versus the color Doppler marker. Unlike B‐mode imaging, the color Doppler marker identified the corresponding port even in highly challenging closed‐chest scans in anesthetized pigs. The method could improve guidance accuracy of cannulas by ultrasound scans.
Using mean frequency estimation algorithms for unambiguous identification and visualization of an acoustically active catheter

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1930-1930

10.1121/1.5036307

Minimally invasive procedures using ultrasound are becoming prominent, especially in applications like biopsy, catheter guidance, and surgeries. In our previous work a catheter tip is fitted with a miniature omnidirectional piezoelectric crystal; the ultrasonic field from the imaging array and the piezoelectric crystal interact resulting in a symmetric Doppler shift. Previously, a frequency domain algorithm was used to identify pixels having the symmetric Doppler shift. The identified pixels can then be visualized on B-mode and color map with a unique color thus representing the location of the catheter tip. However, frequency domain algorithms are computationally expensive and require changes to data workflow. Using mean frequency estimators with symmetric Doppler shift results in the catheter tip being displayed as zero mean noise making it hard to distinguish from color Doppler noise. To overcome this limitation, complex demodulation can be used. Modulating the time domain signal with sine and cosine by the piezoelectric excitation frequency and summing them up results in cancellation of one of the symmetric Doppler components. With only one frequency component remaining mean frequency estimators can be used to identify the location of the catheter. The presented algorithm has lower computational complexity and requires minimal change in software design.
Quantifying nonlinear elasticity modulus of tissue-like solids using acoustic radiation force

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035900

As shown in a recent study, estimation of the magnitude of the acoustic radiation force (ARF) in isotropic tissue-like solids is the key to measuring a third-order nonlinear modulus of elasticity (C)—responsible for coupling the shear and volumetric constitutive responses of a material. Due to experimental limitations, a direct measurement of the ARF in tissue is however difficult. To overcome this problem, we deploy 3D elastodynamic finite element (EFE) simulations of the ARF experiment in tissue-mimicking phantoms to estimate (i) the “background” shear modulus from the phase of the induced shear waves; (ii) the ARF magnitude from the shear wave amplitude, and (iii) the modulus C from the knowledge of the ARF. In this way, by interpreting the ARF-generated shear waves through the prism of 3D-EFE simulations, we facilitate local estimation of the nonlinear C modulus with spatial resolution equaling the size of the focal region. We call this method the C-Elastography (CE). In this study, the CE technique is applied to gelatin phantoms containing an agar-based inclusion. The profiles of the C-modulus in phantoms tested demonstrate good correlation with the phantom geometry, showing marked (and sharp) C-contrast at push points acting on the inclusion. [Acknowledgment: NIH-Grant EB23113.]
Clinical results of ultrasound bladder vibrometry for assessment of bladder compliance

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2176-2176

10.1121/1.4950464

Healthy human bladder is a viscoelastic shell capable of expanding to allow storage of urine at low pressures. The ability to maintain low pressures as the urine volume increases is called bladder compliance. Compliance is a key in proper functioning of urinary system. Spinal cord injuries and other neurogenic diseases can cause deterioration in bladder expansion capability (e.g., through excessive growth of fibrotic tissue), which in turn can increase the rigidity of the wall and reduce bladder compliance. Urodynamic study (UDS) is the clinical standard for evaluation of the bladder compliance through observation of bladder pressure-volume behavior. However, this method is costly and invasive. Ultrasound bladder vibrometry (UBV) has been introduced as noninvasive technique for evaluation of bladder viscoelasticity through excitation of the bladder using ultrasound radiation force and tracking the resulting Lamb waves. Here, we present the results of UBV from 44 patients undergoing concurrent UDS and UBV studies. Our results show that elasticity parameters obtained from the UBV closely correlate with the UDS pressure-volume data with a median Pearson’s correlation value of more than 0.8. These results prove the potential utility of UBV as an alternative noninvasive method for bladder compliance assessment. [Work supported by NIH grant DK99231.]
Differentiation of breast lesions based on viscoelasticity response at sub-Hertz frequencies

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2028-2028

10.1121/1.4949985

There is an urgent need for a noninvasive but more accurate method to assess breast masses before referring the patient to biopsy. In this study, we use the slow viscoelastic creep response to evaluate breast masses at low (<1 Hz) frequencies. This method uses an automated ramp-and-hold compression device and a high-frame-rate ultrasound imaging to track tissue strain. The study cohort included 30 pre-biopsy patients with suspicious masses. Sequential high-frame-rate images were recorded during the ramp-and-hold process. The data were used to calculate the creep response at each point. Then, using a classic linear model, the retardation-time map was created within the field of view. The resulting retardation-time maps exhibited clear distinction of the mass margins. The results showed that benign breast lesions appear with an increase in creep retardation-time compared to surrounding breast glandular tissue, and the opposite trend was true for the malignant lesions. Statistical analysis of the viscoelasticity features revealed that a contrast feature based on the retardation-time is an accurate classifier of malignant and benign masses (P<0.0003). It is concluded that the retardation time is a promising biomarker for differentiation of breast masses. [Work supported by NIH Grant CA168575.]