Change in REVEAL Lite 2 and COMPERA 2.0 risk status in patients with pulmonary arterial hypertension initiating oral treprostinil on dual background therapy: a retrospective chart review
Abstract Background Post-hoc analyses of the FREEDOM-EV study demonstrated that addition of oral treprostinil (ORE) to background monotherapy improves risk in patients with pulmonary arterial hypertension (PAH). Evidence is needed to understand the incremental effect of ORE added to dual background therapy with an endothelin receptor antagonist (ERA) and phosphodiesterase-5 inhibitor (PDE5)/soluble guanylate cyclase stimulator (sGC). Purpose To describe longitudinal changes in REVEAL Lite 2 and COMPERA 2.0 risk status in patients initiating ORE on dual background therapy. Methods A multisite, double-blind retrospective chart review of PAH patients was conducted by US PAH-treating physicians and included patients meeting prior diagnostic PAH criteria (mPAP ≥25 mmHg/PAWP ≤15 mmHg/PVR >3 WU), age ≥18 at diagnosis, began a PAH treatment 01/2014–03/2017, and had NT-proBNP/BNP, WHO functional class (FC), and 6-minute walk distance (6MWD) at baseline visit. Baseline was most recent assessment prior to ORE initiation. This analysis included a subset of patients on dual background therapy at time of ORE initiation without prior prostacyclin use. Follow-up was evaluated in 0–6 and 6–12 months after ORE initiation. Results 30 (61.2%) of 49 ORE patients were on dual background therapy at time of ORE start; 23 had baseline assessments while on dual background therapy and were included in this analysis. At baseline, mean (SD) 6MWD was 140.9 (49.8) m and 21 (91.3%) patients were FC III. Prior to ORE, median (IQR) time on ERA was 6.6 (5.5–7.6) months and PDE5/sGC was 3.7 (3.3–5.7) months. After ORE start, median (IQR) time to follow-up was 4.3 (3.4–5.6) months in 0–6 months and 10.9 (9.6–11.6) months in 6–12 months. Using REVEAL Lite 2, baseline mean (SD) REVEAL Lite 2 risk score was 7.9 (0.8); 1 (4.4%), 2 (8.7%), and 20 (87%) patients were in the low, intermediate, and high risk strata, respectively. In 0–6 months (n=22), 13 (59.1%) patients improved and 9 (40.9%) stabilized REVEAL Lite 2 risk strata from baseline. In 6–12 months (n=22), mean (SD) REVEAL Lite 2 risk score was 6.5 (1.1); 15 patients (68.2%) improved, 6 (27.3%) stabilized, and 1 (4.6%) worsened REVEAL Lite 2 risk strata from baseline. Using COMPERA 2.0, at baseline, 1 (4.4%) patient was in the intermediate-low and 22 (95.7%) patients were in the intermediate-high risk strata. In 0–6 months (n=15), 10 (66.7%) patients improved and 5 (33.3%) patients stabilized COMPERA 2.0 risk strata from baseline. In 6–12 months (n=17), 15 (88.2%) patients improved and 2 (11.8%) stabilized COMPERA 2.0 risk strata from baseline. Conclusion Of patients initiating oral treprostinil in this study, most were on dual background therapy and at high risk by REVEAL Lite 2 or intermediate-high risk by COMPERA 2.0. This analysis suggests adding ORE to dual background therapy can improve risk status in patients, with clinical benefit attained within 6 months and continued incremental improvement through first year of therapy. Funding Acknowledgement Type of funding sources: Private company. Main funding source(s): United Therapeutics Corporation
Vendor independent coronary calcium scoring improves individual risk assessment – the Multi-Ethnic Study of Atherosclerosis (MESA)
Abstract Background Coronary artery calcium (CAC) scoring improves event prediction of coronary heart disease (CHD) and can be used to guide initiation or deferral of statin therapy in asymptomatic individuals at low-to-intermediate risk. However, there is substantial variation of CAC scores acquired with different CT scanners. Therefore, CAC scoring discrepancies may lead to suboptimal patients' treatment and harmonization is needed. Purpose The aim of our study was twofold. Our first aim was to develop a calibration tool resulting in vendor neutral Agatston Score (vnAS). Second, we aimed to assess the effect of using this calibration tool in the existing Multi-Ethnic Study of Atherosclerosis (MESA) study cohort on both risk prediction of coronary heart disease (CHD), and initiation of statin therapy. Methods Two static anthropomorphic phantoms containing multiple CAC inserts were imaged on seven different CT systems and one EBT system. For each CT system, the vnAS calculator parameters were derived using regression analysis based on Agatston scores from EBT and CT. To validate our vnAS, we used CAC scoring information and clinical data of participants from MESA study. All included participants (Cohort I, n=3181) were assigned to one out of four calcium groups, which were defined as zero-calcium (AS and vnAS of 0), low-calcium (AS and vnAS of 1–99) high-calcium (AS and vnAS ≥100), and reclassified individuals (AS <100 and vnAS ≥100). The occurrence of CHD events in each group was assessed and multivariable Cox regression models were used to assess the added value of the vnAS in the prediction of CHD events For a sub-cohort of 890 participants at intermediate cardiovascular risk, the potential benefit from statin therapy was estimated based on the number needed to treat (NNT). NNT were determined for patients with vnAS ≥100 and vnAS ≥300 with original AS below 100 (group I) or 300 (group II), respectively. Results For all CT systems, a high degree of correlation with EBT Agatston scores was shown (R2 >0.932). Using the vnAS, 85 individuals (2.7%) were reclassified from a lower to a higher risk category. For the reclassified participants, CHD event rates increased significantly from 7% to 15% (p=0.008) with a CHD hazard ratio of 3.39 (95% CI 1.82–6.35, p=0.001) (Figure 1). In intermediate risk cohort, the NNT was smaller for reclassified individuals as compared to their original (low) calcium group, at 7 vs 12 for group I and 2 vs 15 for group II, respectively. The summary of vnAS applicability is depicted in Figure 2. Conclusions We developed a calibration tool, which enables to calculate vendor neutral AS (vnAS). Based on vnAS, 85 individuals from MESA study, who were reclassified from a lower to a higher calcium category, did indeed have a higher CHD event rate. Consequently, the potential benefit from statin therapy, based on vnAS, was also increased for reclassified participants at intermediate cardiovascular risk. Funding Acknowledgement Type of funding sources: None.
Outcomes of dual antiplatelet therapy in combination with direct oral anticoagulants in patients with acute coronary syndrome: a meta-analysis
Abstract Background Recent data showed that the use of direct oral anticoagulants (DOAC) in addition to dual antiplatelet therapy (DAPT) is associated with reduced risk of adverse cardiovascular (CV) outcomes in patients with acute coronary syndrome (ACS) with or without percutaneous coronary intervention (PCI), but It has also been associated with increased risk of bleeding. The data differs among different studies, thus, the CV outcomes associated with use of DOAC therapy plus DAPT are not fully understood. We conducted a meta-analysis to explore the CV and bleeding outcomes of DOAC therapy plus DAPT vs DAPT with or without placebo in patients with ACS Methods We conducted a literature search of studies exploring the use of DAPT plus DOAC therapy with focusing on bleeding and CV outcomes including myocardial infarction (MI), stroke, stent thrombosis, limb thrombosis and VTE using Ovid, Scopus, PubMed, Medline, and EBSCO databases from January 2010 to March 2020. We used the following terms for the literature search: (Aspirin AND Clopidogrel OR Prasugrel OR Ticagrelor) AND (Apixaban OR Rivaroxaban OR Edoxaban OR Dabigatran OR Betrixaban). The efficacy outcome was a composite of CV death, MI and stroke, and the safety outcome was major bleeding. Results 4857 articles were included. Only RCTs and RCTs post-hoc analysis, were included (N=3). We found no significant heterogeneity and lower odds of the efficacy outcome in DOAC plus DAPT (experimental arm) compared to DAPT plus placebo (Control arm), which were unchanged in both the fixed and random effect models (Odds Ratio [OR] 0.87, 95% Confidence Interval [CI]: 0.78–0.97, I2=0%). We found no significant heterogeneity and higher odds of the safety outcome in DOAC plus DAPT (experimental arm) compared to DAPT plus placebo (Control arm) (OR fixed model 3.27, 95% CI: 2.28–4.70; OR random model 3.18, 95% CI: 2.21–4.57; I2=0%). Conclusion DOAC therapy plus DAPT in patients with ACS with or without PCI was associated with a lower rate of CV death, MI and stroke when compared to DAPT alone or with placebo and also associated with significant increase in major bleeding Funding Acknowledgement Type of funding sources: None.
A Narrative Review of the Impact of Extracorporeal Membrane Oxygenation on the Pharmacokinetics and Pharmacodynamics of Critical Care Therapies
Objective: Extracorporeal membrane oxygenation (ECMO) utilization is increasing on a global scale, and despite technological advances, minimal standardized approaches to pharmacotherapeutic management exist. This objective was to create a comprehensive review for medication dosing in ECMO based on the most current evidence. Data Sources: A literature search of PubMed was performed for all pertinent articles prior to 2022. The following search terms were utilized: ECMO, pharmacokinetics, pharmacodynamics, sedation, analgesia, antiepileptic, anticoagulation, antimicrobial, antifungal, nutrition. Retrospective cohort studies, case-control studies, case series, case reports, and ex vivo investigations were reviewed. Study Selection and Data Extraction: PubMed (1975 through July 2022) was the database used in the literature search. Non-English studies were excluded. Search terms included both drug class categories, specific drug names, ECMO, and pharmacokinetics. Data Synthesis: Medications with high protein binding (>70%) and high lipophilicity (logP > 2) are associated with circuit sequestration and the potential need for dose adjustment. Volume of distribution changes with ECMO may also impact dosing requirements of common critical care medications. Lighter sedation targets and analgosedation may help reduce sedative and analgesia requirements, whereas higher antiepileptic dosing is recommended. Vancomycin is minimally affected by the ECMO circuit and recommendations for dosing in critically ill adults are reasonable. Anticoagulation remains challenging as optimal aPTT goals have not been established. Relevance to Patient Care and Clinical Practice: This review describes the anticipated impacts of ECMO circuitry on sedatives, analgesics, anticoagulation, antiepileptics, antimicrobials, antifungals, and nutrition support and provides recommendations for drug therapy management. Conclusions: Medication pharmacokinetic/pharmacodynamic parameters should be considered when determining the potential impact of the ECMO circuit on attainment of therapeutic effect and target serum drug concentrations, and should guide therapy choices and/or dose adjustments when data are not available.
NAFLD in Cardiovascular Diseases: A Contributor or Comorbidity?
Nonalcoholic fatty liver disease (NAFLD) and cardiovascular diseases are both highly prevalent conditions around the world, and emerging data have shown an association between them. This review found several longitudinal and cross-sectional studies showing that NAFLD was associated with coronary artery disease, cardiac remodeling, aortic valve remodeling, mitral annulus valve calcifications, diabetic cardiomyopathy, diastolic cardiac dysfunction, arrhythmias, and stroke. Although the specific underlying mechanisms are not clear, many hypotheses have been suggested, including that metabolic syndrome might act as an upstream metabolic defect, leading to end-organ manifestations in both the heart and liver. Management of NAFLD includes weight loss through lifestyle interventions or bariatric surgery, and pharmacological interventions, often targeting comorbidities. Although there are no Food and Drug Administration–approved nonalcoholic steatohepatitis-specific therapies, several drug candidates have demonstrated effect in the improvement in fibrosis or nonalcoholic steatohepatitis resolution. Further studies are needed to assess the effect of those interventions on cardiovascular outcomes, the major cause of mortality in patients with NAFLD. In conclusion, a more comprehensive, multidisciplinary approach to diagnosis and management of patients with NAFLD and cardiovascular diseases is needed to optimize clinical outcomes.
Direct cost analysis of genetic testing for CYP2C19*2 and *3 loss of function variants in percutaneous coronary intervention patients
Abstract Background/Introduction Patients with CYP2C19*2 or *3 loss of function (LOF) variants who undergo percutaneous coronary intervention (PCI) have an increased risk of ischemic events when treated with clopidogrel. Purpose A subgroup of patients who were included in the TAILOR-PCI trial were also enrolled in this study to determine if a genotype-guided (GG) approach based on CYP2C19*2 or *3 LOF variants is cost-effective. Methods Patients were randomized to the conventional therapy group with clopidogrel and to the GG group who underwent point of care genotype testing for CYP2C19*2 or *3 LOF variants. In the GG group, therapy was based on genotype results. Those identified as LOF carriers were prescribed ticagrelor while non-carriers were prescribed clopidogrel. Results There were no significant differences in direct medical costs between the conventional therapy group and GG group (mean $19,747 versus $20,682, p=0.11), however total costs were significantly greater in the GG group which was primarily driven by the outpatient cost of ticagrelor. Furthermore, there was no significant cost difference between ticagrelor treated LOF carriers and clopidogrel treated non-carriers. Conclusion These findings suggest that a GG approach with point of care testing for CYP2C19*2 or *3 LOF variants in patients undergoing PCI may be a cost-effective practice. Funding Acknowledgement Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): NIH grants
Artificial intelligence-enabled electrocardiographic algorithm for the detection of left ventricular dysfunction in emergency department patients undergoing high-sensitivity cardiac troponin T
Abstract Background Artificial intelligence-augmented electrocardiogram (AI-ECG) algorithms have been developed from the standard 12-lead ECG and validated for the recognition of left ventricular systolic dysfunction (LVSD), defined as LV ejection fraction (LVEF)≤35%. Whether AI-ECG facilitates identification of LVSD and is associated with adverse outcomes in emergency department (ED) patients undergoing high-sensitivity cardiac troponin (hs-cTnT) testing is uncertain. Purpose To investigate the diagnostic and prognostic performance of AI-ECG in ED patients undergoing hs-cTnT measurement. Methods Observational US cohort study of ED patients undergoing hs-cTnT measurement. Cases with hs-cTnT increases >sex-specific 99th percentiles were adjudicated following the Fourth Universal Definition of Myocardial Infarction (MI). Post-discharge major adverse cardiac events (MACE) included death, MI, heart failure (HF) hospitalization, stroke or transient ischemic attack, and new onset atrial fibrillation/flutter during 2-years follow-up. The AI-ECG network output, which is a continuous number between 0–1, that provides a probability of LVSD, was obtained for each patient from the first ECG during the index presentation. An AI-ECG threshold of ≥0.256 indicates a positive screen that correlates with a high probability of LVSD. Results Among 1977 patients, 1729 (87%) had a negative AI-ECG screen, while 248 (13%) had a positive AI-ECG screen. Patients with a positive AI-ECG screen were older and had more comorbidities. As compared to patients with hs-cTnT≤99th percentile in whom AI-ECG was positive in 5.8%, those with hs-cTnT>99th percentile had a positive AI-ECG in 22% of cases (p<0.0001). Based on adjudicated diagnoses, the frequency of a positive AI-ECG was 20% in myocardial injury, 38% in type 1 MI, and 20% in type 2 MI. At 2-years follow-up, as compared to patients with a negative AI-ECG, those with a positive AI-ECG had a higher risk for MACE (48% vs. 21%, p<0.0001, adjusted HR 1.39, 95% CI 1.11–1.75) (Figure 1), mainly because of more deaths (43% vs. 30%, p=0.004) and HF hospitalizations (36% vs. 13%, p<0.0001). A positive AI-ECG was associated with a higher risk for MACE (60% vs. 41%, p<0.0001, adjusted HR 1.30, 95% CI 1.02–1.64) in those with hs-cTnT increases >99th percentile, but not in those without hs-cTnT increases. Among patients with an echocardiogram during index presentation or within 30-days (n=452), the diagnostic accuracy of AI-ECG for LVEF ≤35% was 81.4% (95% CI 77.5, 84.9) with a negative predictive value of 96.5% (95% CI 94.0, 98.2). A normal LVEF (>50%) was observed in 87% of those with a negative AI ECG, whereas in those with a positive AI-ECG LVEF was reduced (<50%) in 60%. Conclusions Among ED patients evaluated with hs-cTnT, a positive AI-ECG screen for LVSD identifies patients at high risk of MACE. These findings are largely because of more deaths and HF hospitalizations in those with hs-cTnT increases >sex-specific 99th percentiles. Funding Acknowledgement Type of funding sources: None.
Screening for cardiac allograft rejection among heart transplant recipients using an electrocardiogram-based deep learning model
Abstract Background Current approaches utilizing non-invasive methods to screen for cardiac allograft rejection (gene expression profiling and cell free DNA) have yet to be broadly integrated into heart transplant management and have shown limited discrimination (AUCs of 0.68 and 0.77, respectively). Changes in the electrocardiogram (ECG) have been reported at the time of severe cardiac rejection, including low voltages and conduction abnormalities. It remains unknown if subtle ECG changes correlating with cardiac allograft rejection can be detected earlier using machine learning methods. Purpose We sought to develop an artificial intelligence (AI) model to detect cardiac allograft rejection based on the 12 lead ECG. Methods We identified all patients who underwent a heart transplant at 3 hospital sites within a single health system from Jan 1998 through Apr 2021 and extracted digital 12-lead ECG data as well as endomyocardial biopsy pathology results from the electronic medical record. We partitioned our data into a training (80%), validation (10%), and test set (10%) based on a group stratification sampling. Each patient was present in only one set and each set had a positivity rate of 2.6% with 6,074/758/758 ECGs belonging to 1,146/140/141 unique patients in each set respectively. Cardiac allograft rejection was defined as moderate or severe acute cellular rejection based on International Society for Heart and Lung Transplantation (ISHLT) guidelines. A convolutional neural network, using the 12-lead ECG data as input, was trained with hyperparameter optimization for regularization, learning rate adjustments, and class weights. Model performance metrics were based on the test data and estimated using the final model architecture. Results 1,587 heart transplant recipients who had at least one endomyocardial biopsy were evaluated for inclusion. We limited our sample to ECGs performed within 30 days of the biopsy date (7,590 ECGs, representing 1,425 unique patients). Our study population had a median age of 55.8 years and 28.7% were female. The median number of ECG-biopsy pairs per patient was 5. The majority of endomyocardial biopsy results were classified as none or mild rejection (97.1%), and 2.9% had moderate/severe rejection. The ECG-based AI model detected cardiac allograft rejection with an area under the receiver operative curve (AUC) of 0.84 in the test set. The sensitivity, specificity, positive and negative predictive values were 95%, 52.6%. 5.2% and 99.7% respectively. Conclusions An AI-ECG model appears to outperform novel non-invasive laboratory tests (gene expression profiling and cell free DNA) for detecting cardiac allograft rejection and does not require a blood draw or the additional complexities surrounding sample processing. This model relies on a readily available and relatively inexpensive test, the ECG. In addition, AI predictions can be made available within a few minutes following ECG acquisition. Funding Acknowledgement Type of funding sources: Private hospital(s). Main funding source(s): Mayo Clinic
Basic or comprehensive strain analyses, which variable is better to predict hard endpoints as clinical heart failure in lymphoma patients receiving anthracyclines
Abstract Background Speckle tracking echocardiography (STE) has shown to be a good tool to foresee early myocardial dysfunction in lymphoma patients who receive anthracycline based chemotherapy. Conventional STE such as global longitudinal strain (GLS) is a good predictor of cardiotoxicity in these patients, however, a more in-depth characterization of conventional and comprehensive STE parameters to predict a hard end-point as chemotherapeutic related heart failure (HF) has not been evaluated. Purpose The aim of this prospective study was to evaluate predictability of cancer therapeutic-related clinical HF by conventional and comprehensive STE. Methods We enrolled 269 Hodgkin & non-Hodgkin lymphoma patients who underwent chemotherapy at Mayo Clinic from 2013 through 2021. All patients had an echocardiogram performed at baseline (T0), during chemotherapy (T1) and after (T2). HF was diagnosed by a cardiologist and defined as the first occurrence after the initiation of chemotherapy. Conventional (GLS) and comprehensive strain analyses that included: global circumferential strain (GCS), global radial strain (GRS), global longitudinal early diastolic strain rate (GLSRe), global longitudinal systolic strain rate (GLSRs), global circumferential early diastolic strain rate (GCSRe), global circumferential systolic strain rate (GCSRs), global radial early diastolic strain rate (GRSRe), and global radial systolic strain rate (GRSRs), were performed offline. Logistic regression analyses were used to evaluate the association of 2D and 3D STE measurements with the development of clinical HF. Results Overall, 215 (79.9%) patients had non-Hodgkin lymphoma while 54 (20.1%) had Hodgkin lymphoma. Mean age was 58.4±16.1 years and 64.7% of the patients were males. The most prevalent comorbidities were hypertension (101/37.5%), dyslipidemia (87/32.3%) and diabetes (28/10.4%). HF occurred in 21 (7.8%) patients, including 9 (3.3%) during chemotherapy and 12 (4.5%) after chemotherapy. The best predictors of HF were: i) GLSRe and GCSRs performed at baseline (T0) to predict HF at T1 with an AUC of 0.85 each and p values of 0.0006 and 0.0005 respectively (Table 1); ii) GCSRs and GCS at baseline (T0) to predict HF at T1 or T2 with AUCs of 0.82 (p, <0.0001) and 0.81 (p, 0.0004), respectively. Basic strain (GLS) was able to predict HF when measured at T0 but not when measured at T1. All the AUCs for GLS were below 0.75 (Figure 1). Conclusions To our knowledge this is the first study to evaluate the use of conventional and comprehensive STE to predict a hard end-point as heart failure in patients with lymphoma who received anthracyclines. Comprehensive STE measurements as GLSRs, GLSRe, GCS, GCSRs and GCSRe are better than GLS to predict HF in patients with lymphoma who received anthracycline based chemotherapy. These findings can be crucial for the management of these patients by guiding when to start cardioprotection and/or avoid interruptions of cancer treatment. Funding Acknowledgement Type of funding sources: Private hospital(s). Main funding source(s): Department of cardiovascular diseases, Mayo Clinic, Rochester, MN
Mitral annular plane systolic excursion and global longitudinal strain for the prediction of cardiotoxicity or heart failure in lymphoma patients treated with anthracycline-based chemotherapy
Abstract Background Assessing cardiac performance of patients receiving chemotherapy is a cornerstone for adequate cardiovascular care. Mitral annular plane systolic excursion (MAPSE) has been considered as a surrogate for Ejection Fraction (EF). However, little is known about its role in predicting Cardiotoxicity or Heart Failure in Lymphoma patients, as its relationship with Global Longitudinal Strain (GLS) and EF. Purpose Our aims were: i) to evaluate if MAPSE and GLS can predict the development of CT and/or HF in lymphoma patients treated with anthracyclines and ii) to evaluate its correlation with GLS and EF. Methods For this prospective observational study, 325 Hodgkin (HL) & non-Hodgkin (NHL) lymphoma patients (n=325) treated with anthracyclines were recruited from 2013 to 2021 and followed for 1 year. MAPSE by M-mode and GLS by Speckle-Tracking (ST) were measured at baseline (T0), during treatment (T1), and up to 1 year after chemotherapy completion (T2). CT was defined as a decrease in EF by >10% to a value <50% and HF by a cardiologist as the first occurrence after the initiation of anthracyclines. Logistic regression analyses with Receiving operator characteristics (ROC) and Area under the curve (AUC) were performed. Pearson's correlation coefficient was also calculated. A p-value <0.05 was considered statistically significant. Results Two hundred sixty-four patients (81.2%) had NHL and 61 (18.8%) HL. Of these, fifteen (4.6%) and 21 individuals (6.4%) developed CT at T1 and T2, respectively. Nine subjects (2.8%) developed HF at T1 and 14 (4.3%) at T2. MAPSE at T0 had the highest AUC to predict both HF at T1 (AUC=0.865, cut-off 14.9, sensitivity 100%, specificity 63%, p=0.008) and at T2 (AUC=0.757, cut-off 10.9, sensitivity 67%, specificity 93%, p=0.045). This same variable at T1 predicted HF at T2 with an AUC of 0.752 (cut-off 11.4, sensitivity 67%, specificity 94%, p=0.004). For CT prediction at T2, MAPSE at T1 had an AUC of 0.738 (cut-off 12.5, sensitivity 56%, specificity 85%, p<0.0001). GLS at T0 predicted CT at T1 (AUC=0.657, cut-off −19, sensitivity 67%, specificity 63%, p=0.012) and when obtained at T1, it predicted CT at T2 (AUC=0.776, cut-off −17, sensitivity 74%, specificity 75%, p-value <0.0001) (Table 1). Pearson's correlation between MAPSE and GLS at T0 (coefficient −0.25, p=0.023) at T1 (coefficient −0.38, p<0.0001) at T2 (coefficient −0.037, p<0.0001) and MAPSE with EF at T0 (coefficient 0.33, p=0.0002) at T1 (coefficient 0.28, p<0.0001) and T2 (coefficient 0.29, p<0.001). Conclusions To our best knowledge, this is the first time that MAPSE and GLS were compared to predict CT and HF in lymphoma patients receiving anthracycline-based chemotherapy; we have demonstrated that MAPSE measured at T0 was a very good predictor of HF at T1. Either MAPSE or GLS assessment at T0 and T1 were able to predict CT or HF. Future studies could explore the combination of these two variables to predict either CT or HF. Funding Acknowledgement Type of funding sources: Private hospital(s). Main funding source(s): Department of Cardiovascular Medicine. Mayo Clinic, Rochester-MN