Citations

Clear

16287 citation(s) found for "Su, David".

Significance of a positive tau PET scan with a negative amyloid PET scan
Robinson, Carling G. , Lee, Jeyeon , Min, Hoon‐Ki , Przybelski, Scott A. , Josephs, Keith A. , Graff‐Radford, Jonathan , Jack, Clifford R. , Petersen, Ronald C. , Fields, Julie A. , Lowe, Val J. , Lowe, Val J , Min, Hoon-Ki Paul , Jack, Clifford R , Jones, David T. , Boeve, Bradley F. , Knopman, David S. , Machulda, Mary M.

Mayo Clinic

Alzheimer's & Dementia | December 30, 2023 | Volume: 20 | Issue: 3 | Pages: 1923-1932

10.1002/alz.13608 | PMID 38159060 Get It

AbstractINTRODUCTIONThe implications of positive tau positron emission tomography (T) with negative beta amyloid positron emission tomography (A) are not well understood. We investigated cognitive performance in participants who were T+ but A‐.METHODSWe evaluated 98 participants from the Mayo Clinic who were T+ and A‐. Participants were matched 2:1 to A‐ and T‐ cognitively unimpaired (CU) controls. Cognitive test scores were compared between different groups.RESULTSThe A‐T+ group demonstrated lower performance than the A‐T‐ group on the Mini‐Mental Status Exam (MMSE) (p < 0.001), Wechsler Memory Scale‐Revised Logical Memory I (p < 0.001) and Logical Memory II (p < 0.001), Auditory Verbal Learning Test (AVLT) delayed recall (p = 0.004), category fluency (animals p = 0.005; vegetables p = 0.021), Trail Making Test A and B (p < 0.001), and others. There were no significant differences in demographic features or apolipoprotein E (APOE) e4 genotype between CU A‐T+ and CI A‐T+.DISCUSSIONA‐T+ participants show an association with lower cognitive performance.
Analgesia in Transcutaneous Laryngeal Botulinum Toxin Injections: A Randomized Crossover Trial
Heyes, Richard , Lott, David G. , Karle, William E. , Lott, David G , Karle, William E , Adler, Charles H. , Yee, Claire

Mayo Clinic

The Laryngoscope | December 29, 2023 | Volume: 134 | Issue: 5 | Pages: 2277-2281

10.1002/lary.31208 | PMID 38157199 Get It

ObjectivesThere is an absence of data in the literature regarding methods to improve the patient experience during the performance of awake in‐office laryngeal injections. This study sought to evaluate whether the use of local anesthetic or a vibrating instrument decreased overall pain experienced by patients with laryngeal dystonia, frequently referred to as spasmodic dysphonia (SD), undergoing transcervical botulinum toxin injections.MethodsThis was an unblinded, prospective randomized control trial with a crossover design where each patient received transcutaneous transcricothyroid injection of botulinum toxin with alternating use of no anesthesia, local anesthesia (2% lidocaine in 1:100,000 epinephrine), and vibrating instrument in three consecutive laryngeal injections to treat adductor SD. Patients were randomized to the order they received these treatments. Patients measured pain on a 0–10 visual analogue scale (VAS) and selected their preferred technique after receiving all three analgesic modalities.ResultsThirty‐two patients completed the study. There was no statistically significant difference in pain between the three analgesic techniques (p = 0.38). The most preferred analgesic technique was the vibrating wand (44% (14/32)). Lidocaine was the second most preferred (37% (12/32)) and 19% (6/32) of patients preferred nothing. When combining the wand and nothing groups, 63% of patients preferred one of these two methods (95% exact CI: 44%–79%).ConclusionThere was no statistically significant difference in median pain experienced by patients during laryngeal botulinum toxin injection between these different analgesic modalities. More than half of the patients selected a preference for a technique that did not include lidocaine. This data supports individualization of analgesia during transcutaneous laryngeal injections.Level of Evidence2 Laryngoscope, 134:2277–2281, 2024
Safety of COVID‐19 convalescent plasma: A definitive systematic review and meta‐analysis of randomized controlled trials
Cruciani, Mario , Joyner, Michael J. , Senefeld, Jonathon W. , Sullivan, David , Zani, Matteo , Focosi, Daniele , Franchini, Massimo , Cruciani, Mario , Casadevall, Arturo , Joyner, Michael J , Senefeld, Jonathon W , Sullivan, David J , Focosi, Daniele , Franchini, Massimo , Casadevall, Arturo

Mayo Clinic

Transfusion | December 29, 2023 | Volume: 64 | Issue: 2 | Pages: 388-399

10.1111/trf.17701 | PMID 38156374 Get It

Utility of the Japanese version of the Clinical Dementia Rating® plus National Alzheimer's Coordinating Centre Behaviour and Language Domains for sporadic cases of frontotemporal dementia in Japan
Taomoto, Daiki , Sato, Shunsuke , Kanemoto, Hideki , Suzuki, Maki , Hirakawa, Natsuho, Takasaki, Akihiro , Akimoto, Miu, Satake, Yuto , Koizumi, Fuyuki , Yoshiyama, Kenji , Takahashi, Rei , Shigenobu, Kazue, Hashimoto, Mamoru , Miyagawa, Toji , Mori, Etsuro , Ikeda, Manabu , Boeve, Bradley F. , Knopman, David S.

Mayo Clinic

Psychogeriatrics | December 28, 2023 | Volume: 24 | Issue: 2 | Pages: 281-294

10.1111/psyg.13072 | PMID 38152057 Get It

AbstractBackgroundWe aimed to validate the Clinical Dementia Rating (CDR®) dementia staging instrument plus the National Alzheimer's Coordinating Centre Behaviour and Language Domains (CDR® plus NACC FTLD) for use in clinical settings in Japan and in the Japanese language.MethodsThis prospective observational study enrolled 29 patients with frontotemporal dementia (FTD) and 21 patients with Alzheimer's disease (AD) dementia from the Departments of Psychiatry at Osaka University Hospital and Asakayama General Hospital and the Brain Function Centre at Nippon Life Hospital. CDR® plus NACC FTLD, CDR®, Mini‐Mental State Examination (MMSE), Western Aphasia Battery (WAB), Neuropsychiatric Inventory‐plus (NPI‐plus), Stereotypy Rating Inventory (SRI), and frontal behavioural symptom scores obtained from items of NPI‐plus and SRI, were conducted to assess inter‐ and intra‐rater reliability, validity, and responsiveness. We performed receiver operating characteristic (ROC) curve analysis to evaluate the discriminating power of the Behaviour/Comportment/Personality (BEHAV) and Language (LANG) domains of the CDR® plus NACC FTLD and the MEMORY domain of the CDR® in patients AD dementia and FTD.ResultsThe CDR® plus NACC FTLD showed good inter‐ and intra‐rater reliabilities. In patients with FTD, the BEHAV domain of the CDR® plus NACC FTLD was significantly correlated with all clinical measures except for the SRI total score, while the LANG domain of the CDR® plus NACC FTLD was significantly correlated with the MMSE and the WAB‐Aphasia quotient. In addition, the CDR® plus NACC FTLD sum of boxes significantly changed after 6 months and after 1 year. ROC curve analysis showed that the BEHAV and LANG domains of the CDR® plus NACC FTLD distinguished between patients with AD dementia and FTD better than the MEMORY domain of the CDR®.ConclusionsThis study validated the Japanese version of the CDR® plus NACC FTLD with good reliability, validity, and responsiveness.
Artificial Intelligence Evaluation of Stool Quality Guides Management of Hepatic Encephalopathy Using a Smartphone App
Fagan, Andrew , Gallagher, Mary Leslie, Mousel, Travis, Davis, Brian , Puri, Puneet, Anstey, Jacob, Tiede, David, Kraus, Asaf, Bajaj, Jasmohan S. , Bajaj, Jasmohan S , Fuchs, Michael A. , Puri, Puneet, Simonetto, Douglas A.

Mayo Clinic

American Journal of Gastroenterology | December 28, 2023 | Volume: 119 | Issue: 5 | Pages: 977-981

10.14309/ajg.0000000000002646 | PMID 38153339 Get It

Lactulose-based hepatic encephalopathy treatment requires bowel movements/day titration, which is improved with Bristol stool scale (BSS) incorporation. Dieta app evaluates artificial intelligence (AI)-based BSS (AI-BSS) with stool images. Initially, controls (N = 13) and cirrhosis patients on lactulose/not on lactulose (n = 33) were trained on the app. They entered self-reported BSS (self-BSS) with AI-BSS communicated. Lactulose dose changes were tracked. A subset (n = 12) was retested with AI communication blocked. Most subjects were comfortable with the app. Self/AI-BSS and lactulose dose/AI-BSS correlation increased with app use. AI-BSS communications improved insight into self-BSS over time. Dieta app to gauge stool AI characteristics was acceptable and increased insight into lactulose dose and BSS in cirrhosis.
Flexible CO2 Laser in Therapeutic Bronchoscopy
ORTIZ-JAIMES, GABRIEL E, Mullon, John J., Nelson, Darlene R. , Reisenauer, Janani , Midthun, David E. , Edell, Eric S. , Anderson, Dagny , Vargas-Brochero, Maria J. , Petrossian, R., Kern, Ryan , Vargas-Brochero, Maria, Kern, R

Mayo Clinic

Journal of Bronchology & Interventional Pulmonology | December 28, 2023 | Volume: 31 | Issue: 2 | Pages: 205-214

10.1097/lbr.0000000000000962 | PMID 38151967 Get It

Background: CO2 Laser (CO2L) technology deployable through flexible endoscopes now allows for their use throughout the airway, although published data are limited. Methods: Retrospective analysis of CO2L bronchoscopic procedures, excluding glottic and subglottic interventions. Procedural success was defined as >50% visual reduction in airway obstruction in the area treated or resolution of the procedural indication. Results: Seventy-two procedures were performed on 36 patients. Nonmalignant indications comprised 66%: stent-associated granulation tissue (28%), granulomatosis with polyangiitis lesions (23%), and lung transplant-related granulation tissue (16%) were the most common. Bronchoscopic access was flexible only in 81% and primarily rigid (combined with flexible) in 18%. The site of intervention was the trachea at 19%, the mainstem at 56%, and lobar/segmental airways at 45%. Procedural success was 89%. CO2L was used exclusively in 19%; in 81%, additional techniques were required, most commonly balloon dilation (59%), cryo-debulking (23%), and rigid dilation (16%). Malignant indications had a nonsignificant trend toward requiring adjuvant techniques (P=0.05). Seventy-six percent of the patients required more than 1 procedure. CO2L exclusive cases had no statistically different needs for subsequent therapeutic bronchoscopies (P=0.10) or time to reintervention (109 vs. 41 days, P=0.07), and reintervention-free survival was similar (P=0.10) and difficult to predict. The complication rate attributable to CO2L was 2.7%. Conclusion: CO2L is a safe and useful tool when precise cutting and vaporization are desired. Its use in multi-modality approaches has high levels of success in adequately selected lesions, adding an ablative potential to dilation techniques. Vasculitis-associated scars/webs and granulation tissue (including stent-associated) appear to be ideal targets.
How the United States syphilis epidemic may portend a resurgence of an unusual hematologic condition: The connection between syphilis and paroxysmal cold hemoglobinuria
Jacobs, Jeremy W. , Booth, Garrett S. , Adkins, Brian D. , Adkins, Brian David , Jacobs, Jeremy W , Booth, Garrett , Woo, Jennifer S. , Stephens, Laura D.

Mayo Clinic

American Journal of Hematology | December 28, 2023 | Volume: 99 | Issue: 3 | Pages: 484-485

10.1002/ajh.27190 | PMID 38151909 Get It

Challenges in recognising paroxysmal cold hemoglobinuria
Jacobs, Jeremy W. , Booth, Garrett S. , Villalba, Cristina A. Figueroa , Adkins, Brian D. , Jacobs, Jeremy W , Booth, Garrett , Adkins, Brian David , Woo, Jennifer S. , Stephens, Laura D.

Mayo Clinic

Transfusion Medicine | December 28, 2023 | Volume: 34 | Issue: 1 | Pages: 71-73

10.1111/tme.13024 | PMID 38151804 Get It

Discrepancies among studies reporting the prevalence of positive direct antiglobulin tests in the COVID‐19 patient population
Jacobs, Jeremy W. , Adkins, Brian D. , Booth, Garrett S. , Jacobs, Jeremy W , Booth, Garrett , Adkins, Brian David , Stephens, Laura D. , Woo, Jennifer S.

Mayo Clinic

Transfusion Medicine | December 28, 2023 | Volume: 34 | Issue: 3 | Pages: 234-235

10.1111/tme.13023 | PMID 38151773 Get It

Comparative analysis of syringes versus pump devices in benchtop aspiration thrombectomy models: A systematic review and meta-analysis
Şenol, Yiğit Can , Orscelik, Atakan , Kobeissi, Hassan , Bilgin, Cem , Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F. , Orscelik, Atakan , Kobeissi, Hassan , Bilgin, Cem , Oliver, Alexander A , Ghozy, Sherief , Kadirvel, Ram , Kallmes, David F , Senol, Yigit Can , Li, Jiahui

Mayo Clinic

Interventional Neuroradiology | December 27, 2023 | Volume: 32 | Issue: 3 | Pages: 891-897

10.1177/15910199231222305 | PMID 38151033 Get It

Background Although direct contact aspiration has emerged as one of the leading techniques for mechanical thrombectomy (MT), there is still ongoing debate about the aspiration/suction pump devices that can optimize recanalization rates. To address this gap, we conducted a meta-analysis comparing the aspiration efficacy of 60 ml syringe and pump devices in benchtop MT models. Methods Systematic literature review was conducted using Medline, Embase, Web of Science, and Scopus in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Outcomes of interest included flow rate and vacuum pressure delivered by a 60 ml syringe and several aspiration pumps. We used a random effects model to calculate the mean difference (MD) with 95% confidence intervals (CIs) and a statistically significant difference was considered as a two-sided p -value of less than 0.05. Results We included six benchtop studies comparing 60 ml syringes and vacuum pumps. Our meta-analysis showed that there were no significant differences in vacuum pressure (MD:0.71inHg, 95% CI: [−0.81;2.23], p = 0.359) and flow rate (MD:0.27 mL/s, 95% CI: [−3,07; 3.61], p = 0.873) between 60 ml syringes and vacuum pumps groups. Conclusions Our study demonstrated comparable performance in terms of vacuum pressure and flow rates between a 60 ml syringe and a heterogeneous combination of commercially available aspiration pumps.