Citations

Clear

367 citation(s) found for "Friedman, Paul A".

Right Parasternal Lead Placement Increases Eligibility for Subcutaneous Implantable Cardioverter Defibrillator Therapy in Adults With Congenital Heart Disease
Okamura, Hideo , Webster, Tracy L., Bonnichsen, Crystal R. , Grogan, Martha , Phillips, Sabrina D. , Connolly, Heidi M. , Ammash, Naser M., Warnes, Carole A. , Friedman, Paul A. , McLeod, Christopher J. , DeSimone, Christopher V.

Mayo Clinic

Circulation Journal | April 21, 2016 | Volume: 80 | Issue: 6 | Pages: 1328-1335

10.1253/circj.cj-16-0153 | PMID 27109124 Get It

Ischemic Stroke or Systemic Embolism After Transseptal Ablation of Arrhythmias in Patients With Cardiac Implantable Electronic Devices
Madhavan, Malini , Yao, Xiaoxi , Sangaralingham, Lindsey R. , Asirvatham, Samuel J. , Friedman, Paul A. , Sugrue, Alan , Sugrue, Alan M, McLeod, Christopher J. , DeSimone, Christopher V. , Noseworthy, Peter A. , Asirvatham, Samuel J , Yao, Xiaoxi

Mayo Clinic

Journal of the American Heart Association | April 14, 2016 | Volume: 5 | Issue: 4 | Pages: No page available

10.1161/jaha.115.003163 | PMID 27076562 Get It

Background Incidental mobile thrombi are commonly found on endovascular leads of cardiac implantable electronic devices ( CIED s). Transseptal puncture for catheter ablation of arrhythmia poses a risk for paradoxical embolism. We examined risk of ischemic stroke, transient ischemic attack ( TIA ), or systemic embolism after transseptal ablation in patients with and without CIED s. Methods and Results Using a national administrative claims database, 31 720 patients who underwent a transseptal catheter ablation between January 2004 and September 2014 were identified. Two propensity‐matched cohorts were created by matching demographic variables, administrative variables, Charlson Comorbidity Index, CHA 2 DS 2 ‐Vasc score, and year and indication for ablation (5533 and 11 300 patients with and without CIED s). Incidence rates and Cox proportional hazards models were used to estimate risk of ischemic stroke, TIA , or systemic embolism for patients with and without CIED s. Impact of oral anticoagulation ( OAC ) use on the endpoint was examined. Over a mean follow‐up of 2.1 years, the incidence of the combined endpoint was 1.9 per 100 person‐years in patients with CIED s and 1.5 per 100 person‐years in patients without CIED s ( P =0.03). Among patients not on OAC , presence of a cardiac device was associated with an increased risk (hazard ratio [ HR ], 1.71 [1.24–2.35]; P <0.01), whereas there was no association noted among patients treated with OAC ( HR , 0.98 [0.75–1.28]). Conclusion CIED s are associated with an increased risk of stroke, TIA , or systemic embolism after transseptal ablation, but this risk is attenuated with postablation OAC use. Role of anticoagulation post‐transseptal ablation in patients with CIED warrants further investigation.
Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG
Sapir, Yehu , Dugan, Jennifer , Ackerman, Michael J. , Asirvatham, Samuel J. , Striemer, Bryan L., Bukartyk, Jan , Bennet, Kevin E. , Ladewig, Dorothy J., Gilles, Emily J., Sadot, Dan , Geva, Amir B. , Friedman, Paul A. , Dillon, John J, Dugan, Jennifer L, Bruce, Charles J. , Attia, Zachi I. , DeSimone, Christopher V. , Dillon, John J., Somers, Virend K. , Scott, Christopher G. , Asirvatham, Samuel J

Mayo Clinic

Journal of the American Heart Association | January 25, 2016 | Volume: 5 | Issue: 1 | Pages: No page available

10.1161/jaha.115.002746 | PMID 26811164 Get It

Background Hyper‐ and hypokalemia are clinically silent, common in patients with renal or cardiac disease, and are life threatening. A noninvasive, unobtrusive, blood‐free method for tracking potassium would be an important clinical advance. Methods and Results Two groups of hemodialysis patients (development group, n=26; validation group, n=19) underwent high‐resolution digital ECG recordings and had 2 to 3 blood tests during dialysis. Using advanced signal processing, we developed a personalized regression model for each patient to noninvasively calculate potassium values during the second and third dialysis sessions using only the processed single‐channel ECG . In addition, by analyzing the entire development group's first‐visit data, we created a global model for all patients that was validated against subsequent sessions in the development group and in a separate validation group. This global model sought to predict potassium, based on the T wave characteristics, with no blood tests required. For the personalized model, we successfully calculated potassium values with an absolute error of 0.36±0.34 mmol/L (or 10% of the measured blood potassium). For the global model, potassium prediction was also accurate, with an absolute error of 0.44±0.47 mmol/L for the training group (or 11% of the measured blood potassium) and 0.5±0.42 for the validation set (or 12% of the measured blood potassium). Conclusions The signal‐processed ECG derived from a single lead can be used to calculate potassium values with clinically meaningful resolution using a strategy that requires no blood tests. This enables a cost‐effective, noninvasive, unobtrusive strategy for potassium assessment that can be used during remote monitoring.
Gender, Racial, and Health Insurance Differences in the Trend of Implantable Cardioverter‐Defibrillator (ICD) Utilization: A United States Experience Over the Last Decade
Patel, Nileshkumar , Patel, Nileshkumar J., Edla, Sushruth , Deshmukh, Abhishek, Nalluri, Nikhil , Patel, Nilay, Patel, Achint , Agnihotri, Kanishk, Patel, Nish , Savani, Chirag, Bhimani, Ronak , Thakkar, Badal, Arora, Shilpkumar, Asti, Deepak, Badheka, Apurva O., Parikh, Valay, Mitrani, Raul D., Noseworthy, Peter, Paydak, Hakan, Viles-González, Juan F., Friedman, Paul A. , Patel, Nileshkumar J., Deshmukh, Abhishek , Patel, Nilay , Savani, Chirag, Arora, Shilpkumar , Badheka, Apurva O., Mitrani, Raul D. , Kowalski, Marcin

Mayo Clinic

Clinical Cardiology | January 22, 2016 | Volume: 39 | Issue: 2 | Pages: 63-71

10.1002/clc.22496 | PMID 26799597 Get It

ABSTRACTPrior studies have highlighted disparities in cardiac lifesaving procedure utilization, particularly among women and in minorities. Although there has been a significant increase in implantable cardioverter‐defibrillator (ICD) insertion, socioeconomic disparities still exist in the trend of ICD utilization. With the use of the Nationwide Inpatient Sample from 2003 through 2011, we identified subjects with ICD insertion (procedure code 37.94) and cardiac resynchronization defibrillator (procedure code 00.50, 00.51) as codified by the International Classification of Diseases, Ninth Revision, Clinical Modification. Overall, 1 020 076 ICDs were implanted in the United States from 2003 to 2011. We observed an initial increase in ICD utilization by 51%, from 95 062 in 2003 to 143 262 in 2006, followed by a more recent decline. The majority of ICDs were implanted in men age ≥65 years. Implantation of ICDs was 2.5× more common in men than in women (402 per million vs 163 per million). Approximately 95% of the ICDs were implanted in insured patients, and 5% were used in the uninsured population. There has been a significant increase in ICD implantation in blacks, from 162 per million in 2003 to 291 per million in 2011. We found a significant difference in the volume of ICD implants between the insured and the uninsured patient populations. Racial disparities have narrowed significantly in comparison with those noted in earlier studies and are now more reflective of the population demographics at large. On the other hand, significant gender disparities continue to exist.
Patterns of Anticoagulation Use and Cardioembolic Risk After Catheter Ablation for Atrial Fibrillation
Yao, Xiaoxi , Deshmukh, Abhishek , Houten, Holly Van, Sangaralingham, Lindsey R. , Siontis, Konstantinos C. , Piccini, Jonathan P. , Asirvatham, Samuel J. , Friedman, Paul A. , Packer, Douglas L. , Shah, Nilay D. , Van Houten, Holly, Noseworthy, Peter A. , Gersh, Bernard J. , Asirvatham, Samuel J , Yao, Xiaoxi

Mayo Clinic

Journal of the American Heart Association | November 6, 2015 | Volume: 4 | Issue: 11 | Pages: No page available

10.1161/jaha.115.002597 | PMID 26541393 Get It

Background There is significant practice variation in oral anticoagulation ( OAC ) use following catheter ablation for atrial fibrillation. It is not clear whether the risk of cardioembolism increases after discontinuation of OAC following catheter ablation. Methods and Results We identified 6886 patients within a large national administrative claims database who underwent catheter ablation for atrial fibrillation between January 1, 2005, and September 30, 2014. We assessed the effect of time off of OAC by CHA 2 DS 2 ‐ VAS c score (after adjusting for other comorbidities) on risk of cardioembolism, using Cox proportional hazards models. There was an increase in the use of non–vitamin K OAC after ablation from 0% in 2005 to 69.8% in 2014. OAC discontinuation was high, with only 60.5% and 31.3% of patients remaining on OAC at 3 and 12 months, respectively. The rate of discontinuation was higher in low‐risk patients (82% versus 62.5% at 12 months for CHA 2 DS 2 ‐ VAS c 0–1 versus ≥2, respectively; P <0.001). Stroke occurred in 1.4% of patients with CHA 2 DS 2 ‐ VAS c ≥2 and 0.3% of those with CHA 2 DS 2 ‐ VAS c 0 or 1 over the study follow‐up. The risk of cardioembolism in the first 3 months after ablation was increased among those with any time off OAC (hazard ratio 8.06 [95% CI 1.53–42.3], P <0.05). The risk of cardioembolism beyond 3 months was increased with OAC discontinuation among high‐risk patients (hazard ratio 2.48 [95% CI 1.11–5.52], P <0.05) but not low‐risk patients. Conclusion The overall risk of stroke in postablation patients is low; however, OAC discontinuation after ablation is common and is associated with increased risk of cardioembolism for all patients within the first 3 months and for high‐risk patients in the long term. Continuing OAC for at least 3 months in all patients and indefinitely in high‐risk patients appears to be the safest strategy.
Trends in Use and Adverse Outcomes Associated with Transvenous Lead Removal in the United States
Deshmukh, Abhishek , Patel, Nileshkumar , Patel, Nileshkumar, Patel, Achint , Patel, Nilay, Patel, Nilay, Arora, Shilpkumar , Noheria, Amit , Mulpuru, Siva K. , Badheka, Apurva, Fischer, Avi, Coffey, James O., Cha, Yong‐Mei , Friedman, Paul A. , Asirvatham, Samuel J. , Viles-González, Juan F., Patel, Achint A, Kapa, Suraj , Mulpuru, Siva, Patel, Nileshkumar, Noseworthy, Peter A. , Patel, Nilay, Patel, Nilay, Asirvatham, Samuel J

Mayo Clinic

Circulation | November 4, 2015 | Volume: 132 | Issue: 25 | Pages: 2363-2371

10.1161/circulationaha.114.013801 | PMID 26534954 Get It

Background— Transvenous lead removal (TLR) has made significant progress with respect to innovation, efficacy, and safety. However, limited data exist regarding trends in use and adverse outcomes outside the centers of considerable experience for TLR. The aim of our study was to examine use patterns, frequency of adverse events, and influence of hospital volume on complications. Methods and Results— Using the Nationwide Inpatient Sample, we identified 91 890 TLR procedures. We investigated common complications including pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in-hospital deaths described with TLR, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. We specifically assessed in-hospital death (2.2%), hemorrhage requiring transfusion (2.6%), vascular complications (2.0%), pericardial complications (1.4%), open heart surgery (0.2%), and postoperative respiratory failure (2.4%). Independent predictors of complications were female sex and device infections. Hospital volume was not independently associated with higher complications. There was a significant rise in overall complication rates over the study period. Conclusions— The overall complication rate in patients undergoing TLR was higher than previously reported. Female sex and device infections are associated with higher complications. Hospital volume was not associated with higher complication rates. The number of adverse events in the literature likely underestimates the actual number of complications associated with TLR.
Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?
Fu, Hai‐Xia , Huang, Xinmiao, Li, Zhong , Osborn, Michael J., Asirvatham, Samuel J. , Espinosa, Raúl E. , Brady, Peter A. , Lee, Hon-Chi , Greason, Kevin L. , Sohail, M. Rizwan , Acker, Nancy G., Hodge, David O. , Friedman, Paul A. , Cha, Yong‐Mei , Sohail, Rizwan M., Baddour, Larry M. , Asirvatham, Samuel J , Sohail, M Rizwan

Mayo Clinic

Pacing and Clinical Electrophysiology | August 21, 2015 | Volume: 38 | Issue: 12 | Pages: 1439-1447

10.1111/pace.12736 | PMID 26293652 Get It

Percutaneous Transapical Access With Closure for Ventricular Tachycardia Ablation
Konečný, Tomáš , Friedman, Paul A. , Sanon, Saurabh , Rihal, Charanjit S. , Mulpuru, Siva K. , Rihal, Charanjit S.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | April 21, 2015 | Volume: 8 | Issue: 2 | Pages: 508-511

10.1161/circep.114.002632 | PMID 25900995 Get It

Implantable Cardioverter‐Defibrillator Therapy in Patients With Ventricular Fibrillation out of Hospital Cardiac Arrest Secondary to Acute Coronary Syndrome
Madhavan, Malini , Friedman, Paul A. , Lennon, Ryan J. , Prasad, Abhiram , White, Roger D., Sriram, Chenni S. , Gulati, Rajiv , Gersh, Bernard J. , Prasad, Abhiram

Mayo Clinic

Journal of the American Heart Association | February 26, 2015 | Volume: 4 | Issue: 2 | Pages: No page available

10.1161/jaha.114.001255 | PMID 25713292 Get It

Background Survivors of ventricular fibrillation out of hospital cardiac arrest ( VF ‐ OHCA ) due to a potentially reversible cause such as acute myocardial infarction (MI) or ischemia are considered to be at low risk of recurrent arrhythmia. Implantable cardioverter defibrillators ( ICD ) are not routinely recommended in such patients. However, the outcome of these patients in the era of rapid coronary revascularization and ICD therapy is not known. Methods and Results We examined the outcome of 114 consecutive survivors of VF OHCA due to acute MI or ischemia in Olmsted County, MN from 1990 to 2011. An ICD was implanted in 45/114 patients. ICD recipients had lower EF [median ( IQR ) 38 (26 to 54) versus 48 (35 to 58) %, P =0.04]. During a median ( IQR ) follow‐up of 9.9 (4.4 to 14.6) years, ICD implantation was associated with reduced cardiac mortality ( HR 0.24 [0.07 to 0.88], P =0.031) and a trend towards reduced all‐cause mortality ( HR 0.56 [0.30 to 1.02], P =0.059) after adjusting for the first principal component. One or more appropriate ICD therapies were delivered in 19/45, with half of the patients receiving therapy within 1 year. Patients with EF ≤35% at discharge continued to be at long‐term risk for ICD therapy compared with those with EF >35% who were at increased risk predominantly in the first 8 months. EF and revascularization were not significantly associated with ICD therapy in the multivariable analysis. Conclusions Patients with VF ‐ OHCA in the setting of acute MI or myocardial ischemia remain at high risk of recurrent ventricular arrhythmias, particularly if EF ≤35%. This suggests that ICD implantation may be reasonable if EF ≤35%.
Troubleshooting Implantable Cardioverter-Defibrillator Sensing Problems II
Swerdlow, Charles D. , Asirvatham, Samuel J. , Ellenbogen, Kenneth A. , Friedman, Paul A. , Asirvatham, Samuel J , Ellenbogen, Kenneth A

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | February 17, 2015 | Volume: 8 | Issue: 1 | Pages: 212-220

10.1161/circep.114.002514 | PMID 25691555 Get It