Back to Authors

Sanon, Saurabh

https://orcid.org/0000-0002-7600-4388

A5046637054 | I1330342723

Mayo Clinic

for the SURTAVI Trial Investigators

Citations 6

Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients

JAMA Cardiology | August 24, 2022 | Volume: 7 | Issue: 10 | Pages: 1000

10.1001/jamacardio.2022.2695 | PMID 36001335

Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
A Novel Technique to Reduce Contrast Exposure During Subclavian Interventions

Vascular and Endovascular Surgery | January 24, 2017 | Volume: 51 | Issue: 2 | Pages: 84-86

10.1177/1538574416689415 | PMID 28114856

We describe a novel technique to minimize total body contrast exposure during endovascular angiography. A patient with severe renal impairment and history of contrast-induced nephropathy was referred for subclavian artery intervention. Angiography and intervention was performed via transfemoral access, while a transradial sheathless-guiding catheter was used to aspirate injected contrast/blood mix from the downstream axillary artery. Semiquantitative analysis indicated approximately 50% of the injected contrast was retrieved. Adaptation of this simple strategy could be considered for selected coronary, lower extremity, and carotid procedures, using contrast removal techniques from the coronary sinus, femoral, and jugular veins.
Techniques and Outcomes for the Treatment of Paravalvular Leak

Circulation: Cardiovascular Interventions | July 24, 2015 | Volume: 8 | Issue: 8 | Pages: No page available

10.1161/circinterventions.115.001945 | PMID 26206850

Percutaneous Transapical Access With Closure for Ventricular Tachycardia Ablation

Circulation: Arrhythmia and Electrophysiology | April 21, 2015 | Volume: 8 | Issue: 2 | Pages: 508-511

10.1161/circep.114.002632 | PMID 25900995

Hydrophilic polymer embolism induced acute transcatheter aortic valve thrombosis: A novel complication

Catheterization and Cardiovascular Interventions | January 9, 2014 | Volume: 83 | Issue: 7 | Pages: 1152-1155

10.1002/ccd.25353 | PMID 24403026

Hydrophilic polymer coated introducer sheaths and medical devices are widely used in interventional cardiology. Despite the potential procedural advantages that these provide, a risk of polymer embolization has been recently reported. We describe the first reported case of hydrophilic polymer induced acute transcatheter aortic valve thrombosis. © 2014 Wiley Periodicals, Inc.
Magnetic navigation facilitates percutaneous coronary intervention for complex lesions

Catheterization and Cardiovascular Interventions | December 11, 2013 | Volume: 84 | Issue: 4 | Pages: 660-667

10.1002/ccd.25321 | PMID 24327388

BackgroundWe sought to determine the utility of a magnetic navigation system (MNS) in treating a variety of coronary artery lesions including those that could not be revascularized with standard percutaneous coronary intervention (PCI). MNS may add value in the treatment of tortuous arteries and bifurcation lesions; however its widespread adoption has lagged because of cost and a lack of clear advantage over conventional PCI. We performed a retrospective analysis to determine whether MNS improved procedural success for highly complex lesions.Methods and ResultsOne hundred and forty‐eight patients underwent treatment with MNS at Mayo Clinic, Rochester. Clinical data, angiographic and procedural characteristics, lesion crossing success and outcomes were reviewed. Overall 133 patients underwent successful revascularization with 87% (143) of 164 lesions crossed using MNS alone. Another six lesions required a combination of MNS and conventional devices resulting in overall success of 91% (149/164). Eighteen complex lesions had previously failed PCI and 12 (67%) were successfully treated with MNS. Success after failed PCI was higher (88%) when a frequent user operated MNS, but occasional users also noted incremental success (30%). Twenty‐five chronic total occlusions were included amongst these 164 lesions, with observed antegrade MNS lesion crossing rates of 78% for regular and 14% for occasional users.ConclusionsMNS is a useful adjunct to performance of PCI. This specialized technology has a clear learning curve and can facilitate treatment of highly complex lesions. © 2013 Wiley Periodicals, Inc.