Citations

Showing 10 of 108060 citations.

Comparative sensitivity and accuracy of 24 vs. 18 MHz ultrasound probes for the diagnosis of flexor tendon repair integrity
Renfree, Sean P. , Hinckley, Nathaniel B. , Dahiya, Nirvikar , Zhang, Nan , Renfree, Kevin J. , Renfree, Sean , Renfree, Kevin

Mayo Clinic

Australasian Journal of Ultrasound in Medicine | August 16, 2023 | Volume: 26 | Issue: 4 | Pages: 230-235

10.1002/ajum.12359 | PMID 38098614 Get It

AbstractPurposeTo determine whether a 24 MHz transducer significantly improves sensitivity, specificity and accuracy in evaluating flexor tendon repair integrity compared with an 18 MHz transducer.MethodsOne hundred and twelve cadaveric digits were randomised to an intact repair or simulated ‘failed’ repair, and to a two‐ or eight‐strand repair of a flexor digitorum profundus laceration. A blinded sonologist evaluated specimens in static mode using 18 and 24 MHz transducers. Gaps were remeasured after scanning, and final gap width recorded. McNemar's exact test calculated differences between sensitivity, specificity and accuracy, and chi‐squared test to compare sensitivity, specificity and accuracy between number of strands (2 vs. 8) and repair gap (≥4 mm).ResultsThe 24 MHz transducer had higher sensitivity (81 vs. 59%), lower specificity (67 vs. 70%) and higher overall accuracy (74 vs. 64%), than the 18 MHz transducer. The difference for sensitivity was significant (P = 0.011), but not differences for specificity and overall accuracy (P > 0.05). Pearson's correlation (r = 0.61) demonstrated a moderate‐to‐strong positive correlation between measured and true gap sizes. Increased number of suture strands (2 vs. 8) did not impair sensitivity, specificity nor accuracy.DiscussionUltrasound may tend to overestimate gap width, and a slight risk that some intact repairs, or those with small, clinically insignificant gaps may undergo surgical exploration that may not be indicated.ConclusionsA 24 MHz transducer is a more sensitive and accurate transducer for assessing flexor tendon repair integrity and measuring small gaps.
To ultrasound or auscultate? That is the question!
Musa, Arif , Carpenter‐Thompson, Rhett, Arnold, El Caney, Johnson, Samuel , Harb, Ali, Carpenter-Thompson, Rhett

Mayo Clinic

Journal of Clinical Ultrasound | August 16, 2023 | Volume: 51 | Issue: 7 | Pages: 1144-1145

10.1002/jcu.23538 | PMID 37584324 Get It

Atypical distal tracheal fibrous bridge and bronchial stenosis in an adult patient with bronchopulmonary dysplasia
Wadiwala, Ishaq , Lee‐Mateus, Alejandra Yu , Alhayek, Bakr , Hazelett, Britney N. , Fernández-Bussy, Sebastián , Wadiwala, Ishaq J , Yu Lee-Mateus, Alejandra , Fernandez-Bussy, Sebastian , Alhayek, Bakr , Abia‐Trujillo, David , Chadha, Ryan

Mayo Clinic

Respirology Case Reports | August 16, 2023 | Volume: 11 | Issue: 9 | Pages: No page available

10.1002/rcr2.1203 | PMID 37593371 Get It

AbstractTracheobronchial stenosis (TBS) in adults derives from congenital and acquired conditions, including prolonged mechanical intubation, expiratory central airway collapse, infectious or inflammatory disease, and malignancy. The most common clinical presentation is shortness of breath, recurrent infections, and chronic cough. TBS is usually diagnosed via computed tomography or bronchoscopy, with the latter doubling as a therapeutic tool. We present a case of an atypical fibrotic bridge connecting the walls of the distal trachea and fibrotic bronchial stenosis treated with electrocautery knife and balloon dilation, in an adult patient with bronchopulmonary dysplasia.
Antidepressant-Associated Treatment Emergent Mania
Núñez, Nicolás A. , Özerdem, Ayşegül , Singh, Balwinder , Prieto, Miguel L. , Frye, Mark A. , Melhuish Beaupre, Lindsay, Singh, Balwinder , Ozerdem, Aysegul , Coombes, Brandon J. , Beaupre, Lindsay Melhuish , Romo‐Nava, Francisco , Gardea‐Resendez, Manuel , Veldić, Marin , Sánchez-Ruiz, Jorge A. , Cuéllar‐Barboza, Alfredo B. , Leung, Jonathan G. , McElroy, Susan L. , Biernacka, Joanna M.

Mayo Clinic

Journal of Clinical Psychopharmacology | August 16, 2023 | Volume: 43 | Issue: 5 | Pages: 428-433

10.1097/jcp.0000000000001747 | PMID 37683232 Get It

Abstract Background The purpose of this study was to review the association between the SLC6A4 5-HTTLPR polymorphism and antidepressant (AD)-associated treatment emergent mania (TEM) in bipolar disorder alongside starting a discussion on the merits of developing risk stratification models to guide when not to provide AD treatment for bipolar depression. Methods Studies that examined the association between clinical and genetic risk factors, specifically monoaminergic transporter genetic variation, and TEM were identified. A meta-analysis was performed using the odds ratio to estimate the effect size under the Der-Simonian and Laird model. Results Seven studies, referencing the SLC6A4 5-HTTLPR polymorphism and TEM (total N = 1578; TEM+ =594, TEM− = 984), of 142 identified articles were included. The time duration between the start of the AD to emergence of TEM ranged from 4 to 12 weeks. There was a nominally significant association between the s allele of the 5-HTTLPR polymorphism and TEM (odds ratio, 1.434; 95% confidence interval, 1.001–2.055; P = 0.0493; I 2 = 52%). No studies have investigated norepinephrine or dopamine transporters. Conclusion Although the serotonin transporter genetic variation is commercially available in pharmacogenomic decision support tools, greater efforts, more broadly, should focus on complete genome-wide approaches to determine genetic variants that may contribute to TEM. Moreover, these data are exemplary to the merits of developing risk stratification models, which include both clinical and biological risk factors, to guide when not to use ADs in bipolar disorder. Future studies will need to validate new risk models that best inform the development of personalized medicine best practices treating bipolar depression.
Physicians’ knowledge, attitudes, and beliefs regarding practices of male and female surgical sterilization procedures in Lebanon
Armache, Alexandre , Heidar, Nassib Abu, Fadel, Anthony, Nehme, Jimmy, Bachir, Bassel G. , Najdi, Jad A. , Chawareb, Elia Abou , Zein, Marwan , Fadel, Anthony

Mayo Clinic

No container title available | August 16, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-3236682/v1 Get It

Abstract Objective Surgical sterilization, including vasectomy in males and tubal ligation in females, is a highly effective but underutilized contraception method. Adoption rates vary globally mostly due to misconceptions by both the general public and practicing physicians. Our survey aims to explore physicians' knowledge, attitudes and beliefs about surgical sterilization techniques.Study Design A web-based survey of four parts was sent to residents and attending physicians of different specialties in Lebanon between April 2022 and April 2023. 183 physicians responded to the survey. Data was analyzed using IBM SPSS Statistics. A descriptive analysis was performed using the chi-square test for categorical variables and ANOVA for continuous variables.Results Physicians specialized in Urology, OB/GYN, Family medicine and Internal medicine, filled the survey. The majority were resident physicians (79%), male (57%), single (72%) and did not receive training in family planning (73%). Knowledge assessment showed an average score of 5/7. After setting this as a passing score, 60.7% of participants passed the assessment with higher likelihood of passing among attending physicians (84.6%), OB/GYN physicians (94.4%), married participants (80.8%), and physicians who received training in family planning (91.8%). Recommendations varied among specialties, with urologists being more likely to recommend vasectomy depending on the clinical scenario (70–97%). Most physicians perceived the general public preferring tubal ligation as a sterilization method (98%).Conclusion Surgical sterilization is underutilized mostly due to lack of knowledge and cultural beliefs among practicing physicians in our region. Ongoing education is needed in medical training to promote family planning.
Leadership Development in Early Career Scientists: Themes and Feedback from Executive Coaching and Mindful Leadership Training
Morrow, Melissa M. , Schafer, Marissa , Kantarci, Kejal , Vachon, Celine M. , Morrow, Melissa M , Kantarci, Kejal , Schafer, Marissa J , Mielke, Michelle M. , Vachon, Celine M. , Winham, Stacey J.

Mayo Clinic

Journal of Women's Health | August 16, 2023 | Volume: 32 | Issue: 8 | Pages: 877-882

10.1089/jwh.2023.0024 | PMID 37585518 Get It

A TGF-β/KLF10 signaling axis regulates atrophy-associated genes to induce muscle wasting in pancreatic cancer
Dasgupta, Aneesha , Gibbard, Daniel F., Schmitt, R. , Arneson‐Wissink, Paige C. , Ducharme, Alexandra M. , Bruinsma, Elizabeth S. , Hawse, John R. , Jatoi, Aminah , Schmitt, Rebecca E, Bruinsma, Elizabeth S , Ducharme, Alexandra , Gibbard, D., Doles, Jason D.

Mayo Clinic

Proceedings of the National Academy of Sciences | August 16, 2023 | Volume: 120 | Issue: 34 | Pages: No page available

10.1073/pnas.2215095120 | PMID 37585460 Get It

Cancer cachexia, and its associated complications, represent a large and currently untreatable roadblock to effective cancer management. Many potential therapies have been proposed and tested—including appetite stimulants, targeted cytokine blockers, and nutritional supplementation—yet highly effective therapies are lacking. Innovative approaches to treating cancer cachexia are needed. Members of the Kruppel-like factor (KLF) family play wide-ranging and important roles in the development, maintenance, and metabolism of skeletal muscle. Within the KLF family, we identified KLF10 upregulation in a multitude of wasting contexts—including in pancreatic, lung, and colon cancer mouse models as well as in human patients. We subsequently interrogated loss-of-function of KLF10 as a potential strategy to mitigate cancer associated muscle wasting. In vivo studies leveraging orthotopic implantation of pancreas cancer cells into wild-type and KLF10 KO mice revealed significant preservation of lean mass and robust suppression of pro-atrophy muscle-specific ubiquitin ligases Trim63 and Fbxo32, as well as other factors implicated in atrophy, calcium signaling, and autophagy. Bioinformatics analyses identified Transforming growth factor beta (TGF-β), a known inducer of KLF10 and cachexia promoting factor, as a key upstream regulator of KLF10. We provide direct in vivo evidence that KLF10 KO mice are resistant to the atrophic effects of TGF-β. ChIP-based binding studies demonstrated direct binding to Trim63 , a known wasting-associated atrogene. Taken together, we report a critical role for the TGF-β/KLF10 axis in the etiology of pancreatic cancer–associated muscle wasting and highlight the utility of targeting KLF10 as a strategy to prevent muscle wasting and limit cancer-associated cachexia.
Viewpoint: What’s in a name: a reflection 20 years later
Woywodt, Alexander , Matteson, Eric L.

Mayo Clinic

Rheumatology | August 16, 2023 | Volume: 63 | Issue: 2 | Pages: 261-263

10.1093/rheumatology/kead411 | PMID 37589568 Get It

When I say… transformative learning
Vipler, Benjamin , Sawatsky, Adam P. , Vipler, Benjamin S

Mayo Clinic

Medical Education | August 16, 2023 | Volume: 57 | Issue: 12 | Pages: 1184-1186

10.1111/medu.15189 | PMID 37584372 Get It

Transformation = change. Learning = change. So what do @VipsMDMEd & @APSawatskyMD mean when they say #TransformativeLearning?
Magnetic Resonance Imaging Artifact Associated With Transcutaneous Bone Conduction Implants: Cholesteatoma and Vestibular Schwannoma Surveillance
Nassiri, Ashley M. , Lane, John I. , McGee, Kiaran P. , Trzasko, Joshua D. , Carlson, Matthew L. , Messina, Steven A. , Benson, John C.

Mayo Clinic

Otolaryngology–Head and Neck Surgery | August 16, 2023 | Volume: 170 | Issue: 1 | Pages: 187-194

10.1002/ohn.474 | PMID 37582349 Get It

AbstractObjectiveTo evaluate the magnetic resonance (MR) image artifact and image distortion associated with the two transcutaneous bone conduction implants currently available in the United States.Study DesignCadaveric study.MethodsTwo cadaveric head specimens (1 male, 1 female) were unilaterally implanted according to manufacturer guidelines and underwent MR imaging (General Electric and Siemens 1.5 T scanners) under the following device conditions: (1) no device, (2) Cochlear Osia with magnet and headwrap, (3) Cochlear Osia without magnet, and (4) MED‐EL Bonebridge with magnet. Maximum metal mitigation techniques were employed in all conditions, and identical sequences were obtained. Blinded image scoring (diagnostic vs nondiagnostic image) was performed by experienced neuroradiologists according to anatomical subsites.ResultsAll device conditions produced artifact and image distortion. The Osia with magnet produced diagnostic T1‐ and T2‐weighted images of the ipsilateral temporal bone, however, non‐echo planar imaging diffusion‐weighted imaging (DWI) was nondiagnostic. The Osia without magnet scanned on the Siemens MR imaging demonstrated the least amount of artifact and was the only condition that allowed for diagnostic imaging of the ipsilateral temporal bone on DWI. The Bonebridge produced a large area of artifact and distortion with the involvement of the ipsilateral and contralateral temporal bones.ConclusionIn summary, of the three device conditions (Osia with magnet, Osia without magnet, and Bonebridge), Osia without magnet offered the least amount of artifact and distortion and was the only condition in which diagnostic DWI was available for the middle ear and mastoid regions on the Siemens MR imaging scanner.