Citations

Clear

237 citation(s) found for "Desimone, C".

Recurrent Gastrointestinal Bleeding in Patients With Atrial Fibrillation Treated With Left Atrial Appendage Occlusion
Ramadan, Adham, Doma, Mohamed , Félix, Iuri Ferreira , Ahmed, Mahmoud Samy, Mahmoud, Ahmed K., Ismayl, Mahmoud, Karara, Yehia , Villablanca, Pedro A., Saw, J, DeSimone, Christopher V., Doma, Mohamed , Ferreira Felix, Iuri , Mahmoud, Ahmed K , DeSimone, Christopher V , Ramadan, Adham, Kamel, Ibrahim, Ismayl, Mahmoud , Villablanca, Pedro, Saw, Jacqueline , DeSimone, Christopher V. , Goldsweig, Andrew M.

Mayo Clinic

Pacing and Clinical Electrophysiology | February 21, 2026 | Volume: 49 | Issue: 7 | Pages: 898-910

10.1111/pace.70177 | PMID 41721735 Get It

ABSTRACT Background Concomitant atrial fibrillation (AF) and gastrointestinal (GI) bleeding present a clinical challenge due to recurrent bleeding risk associated with anticoagulation for AF‐associated stroke prevention. Left atrial appendage occlusion (LAAO) offers an alternative stroke prevention strategy, but its impact on recurrent GI bleeding remains unknown. Methods This retrospective, multicenter cohort study used the TriNetX database to identify adults with AF on oral anticoagulation and a history of GI bleeding. Patients were stratified by treatment with or without LAAO. 1:1 propensity score matching (PSM) was employed. The primary outcome was recurrent GI bleeding. Cox regression analysis was used to generate hazard ratios (HRs) with 95% confidence intervals (CIs). Odds ratios (ORs) were used to evaluate effect sizes between groups. Kaplan–Meier curves were used for time‐to‐event analyses. Results After PSM, 9259 patients were compared in each group. Odds of recurrent GI bleeding were consistently lower in patients undergoing LAAO than without LAAO across all follow‐up intervals: at 3 months (OR 0.84; 95% CI 0.78–0.91), 6 months, 1 year, 3 years, and 5 years (OR 0.87; 95% CI 0.82–0.92). Kaplan–Meier analysis demonstrated significantly lower risk of recurrent GI bleeding with LAAO (HR 0.80; 95% CI 0.76–0.84; p < 0.01). Conclusion In patients with AF and prior GI bleeding, LAAO was associated with a significantly lower risk of recurrent GI bleeding at short‐term and long‐term time intervals.
High-power short-duration ablation versus conventional power ablation in pulmonary vein isolation of atrial fibrillation patients: a systematic review and meta-analysis of randomized controlled trials
Cabral, D Curi Barbosa Izoton, Rivera, A , Braga, M, Passos, B Mariz Ferreira, Felix, I Ferreira, Ternes, C, Brigido, A Regia Dantas, Carvalho, G Dagostin De, Deshmukh, A, Desimone, C, Cabral, David C. B. I. , Braga, M, Passos, Bárbara Mariz Ferreira, Félix, Iuri Ferreira , Ternes, Caique M. P. , Brígido, Alexandra Régia Dantas , Carvalho, G Dagostin De, Deshmukh, Abhishek , DeSimone, Christopher V.

Mayo Clinic

European Heart Journal | February 5, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.814 Get It

Abstract Introduction High-power short-duration (HPSD) ablation has emerged as a promising alternative to conventional power delivery (CPD) for pulmonary vein isolation (PVI) among patients with atrial fibrillation (AF). However, its efficacy, procedural efficiency, and safety profile remain uncertain. Methods PubMed, Embase, Cochrane Library and ClinicalTrials.Gov databases were systematically searched for randomized controlled trials (RCTs) comparing HPSD with CPD ablation for PVI in patients with AF. Random-effects models were used to pool hazard ratios (HR) and risk ratios (RR) with 95% confidence intervals (CI). Results Seven RCTs with 1,006 patients (514 HPSD, 489 CPD) were included. No significant differences were found in freedom from arrhythmia during the follow-up period (HR 0.77; 95% CI 0.41–1.45; p=0.424). AF recurrence did not differ (RR 0.94; 95% CI 0.65–1.36; p=0.733) between groups. HPSD had a significantly shorter procedural (MD -22.61 min; 95% CI -33.18, -12.04; p&lt;0.001) and RF ablation (MD -15.70 min; 95% CI -20.86, -10.55; p&lt;0.001) times, with comparable fluoroscopy time (MD 0 min; 95% CI -0.44, 0.45; p=0.99) between groups. Conclusion In patients with AF undergoing PVI, HPSD did not increase freedom from arrhythmia as compared with CPD ablation, however it was associated with shorter procedure and RF ablation times. These findings suggest that HPSD may be a more efficient approach without compromising clinical outcomes.
Atrial fibrillation and flutter conversion with pulsed electric field delivery: preclinical proof of concept
Tan, N, Munoz, F Del-Carpio, Tri, Jason , Koya, T, Otsuka, Naoto , Desimone, C, Yalamuri, S, Maor, Elad, Miklavcic, D, Asirvatham, S, Munoz, Freddy Del‐Carpio , Koya, Taro , DeSimone, Christopher V. , Yalamuri, Suraj , Maor, Elad , Castellví, Quim , Ivorra, Antoni , Miklavčič, Damijan , Asirvatham, Samuel J.

Mayo Clinic

European Heart Journal | February 4, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.786 Get It

Abstract Background Many patients with atrial fibrillation (AF) suffer life-limiting symptoms and heart failure. Although enormous advances in rhythm control have been made, device-based therapies for treating recurrent episodes are limited. Using pulsed electric fields (PEF) to induce reversible electroporation of cardiac tissue may effectively terminate AF. Purpose To assess the feasibility of PEF delivery for converting atrial arrhythmias via reversible electroporation. Methods Four swine models were used in this acute study. Custom-made decapolar catheters for PEF delivery were deployed with the following configurations: 1. Endocardial right atrium (RA) and coronary sinus (CS), n=2; 2. Endocardial RA and epicardial left atrium (epiLA), n=2. AF and atrial flutter (AFL) were induced with programmed stimulation. PEF delivery was performed using the BTX 830 generator. For each attempt, a single monophasic pulse at 10 or 20µs pulse width was administered, with voltage varied across attempts (range 750-3000V). Successful (type 1 and 2 breaks) and unsuccessful conversion attempts were recorded. Post-PEF signal changes and arrhythmias were identified. Results A total of 58 AF/AFL (28 and 30 respectively) episodes were induced. Of the 37 successful conversion attempts, 33 (89.1%) were type 1 breaks. Conversion success probabilities generally increased with higher voltages for both configurations. &gt;70% conversion success was seen with ≥1500V for the RA/CS configuration and ≥2000V for the RA/epiLA configuration. Arrhythmias including intra-atrial delay and high-grade atrioventricular block were seen, usually following successive PEF deliveries. Significant muscle stimulation was provoked with the current experimental setup. Conclusion Termination of atrial arrhythmias with PEF delivery is feasible, although further work is required to optimize its efficacy and safety.
Ventricular pulsed field defibrillation: preclinical feasibility study
Tan, N, Munoz, F Del-Carpio, Tri, Jason , Koya, T, Otsuka, Naoto , Desimone, C, Yalamuri, S, Maor, Elad, Miklavcic, D, Asirvatham, S, Munoz, Freddy Del‐Carpio , Koya, Taro , DeSimone, Christopher V. , Yalamuri, Suraj , Maor, Elad , Castellví, Quim , Ivorra, Antoni , Miklavčič, Damijan , Asirvatham, Samuel J.

Mayo Clinic

European Heart Journal | February 4, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.788 Get It

Abstract Background Ventricular fibrillation (VF) is a leading cause of sudden cardiac death worldwide. Defibrillation via direct current shocks is effective but associated with significant pain and morbidity, prompting the need for alternative approaches. Reversible electroporation of cardiac tissue with pulsed electric fields (PEF) may be an effective means of terminating VF. Purpose To assess the feasibility of PEF delivery for terminating VF. Methods 5 acute swine models were used. Mechanical circulatory support with peripheral veno-arterial extracorporeal membrane oxygenation +/- percutaneous left ventricular assist device (Impella 5.5 L) was implemented and titrated to a mean arterial pressure ≥65 mmHg. Decapolar catheters were introduced into the endocardial right and/or left ventricle as well as epicardium. VF was induced with R on T shocks or rapid ventricular pacing. PEF was delivered with the endocardial catheter as the cathode and epicardial catheter as the anode; monophasic pulses (5-10) at 3000V, 100µs, and 200ms inter-pulse intervals were used. If VF persisted post-PEF, catheters were repositioned into regions of intact voltages for repeat delivery. Results 10 VF episodes were induced, 7 of which were successfully terminated with PEF delivery (70.0%). The median number of attempts to achieve VF termination was 2 (range 1-5). The post-VF rhythm was complete heart block with ventricular asystole in all successful defibrillation attempts, with no recovery after 30 minutes of observation. Significant muscle stimulation was seen with the utilized PEF parameters and catheter configurations. Conclusion Termination of VF using PEF – pulsed field defibrillation – is possible. However, further study is required to optimize delivery parameters/configurations to improve effectiveness and avoid muscle stimulation as well as conduction abnormalities.
Clinical outcomes after implantable cardioverter-defibrillator therapy in patients with chronic Chagas cardiomyopathy: an updated systematic review and meta-analysis
Felix, I Ferreira, Vizentin, V Karlinski, Cabral, D, Schwengber, W Klein, Nogueira, A, Chagas, G C L, Deshmukh, A J, Desimone, C V, Félix, Iuri Ferreira , Vizentin, Vanessa Karlinski , Felix, Nicole Santos , Schwengber, Wallace Klein , Chagas, Gabriel Cavalcante Lima , Deshmukh, A J, DeSimone, Christopher V.

Mayo Clinic

European Heart Journal | February 4, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.668 Get It

Abstract Background Implantable cardioverter-defibrillator (ICD) is a well-established therapeutic option associated with decreased mortality in patients with ischemic and non-ischemic cardiomyopathies. However, the indications for patients with chronic Chagas cardiomyopathy (CCC) are not well established since these patients were underrepresented in the trials validating ICD use. Purpose This systematic review and single-arm meta-analysis aims to synthetize the available evidence in the literature on the role and outcomes of ICD in CCC. Methods A systematic search of PubMed, Web of Science, Cochrane, and LILACS registries was performed following PRISMA guidelines. Studies evaluating the response to ICD in CCC were included. There were no language restrictions. Data were collected and synthesized using a meta-analysis of proportions with Freeman-Tukey double-arcsine transformation as needed. Results We included 14 observational studies and 1 randomized clinical trial (RCT), comprising 1315 patients with CCC. Mean age at ICD implantation was 58.2 ± 11.8, 65% were male, and 77% received an ICD for secondary prevention. During a mean follow up of 37.3 ± 37.0 months, the all-cause death rate was 22% (95% CI 15 to 29%; Figure 1A), the cardiovascular death rate was 16% (95% CI 11 to 22%; Figure 1B), the sudden cardiac death rate was 3% (95% CI 2 to 5%), and the non-cardiovascular death rate was 7% (95% CI 2 to 5%). In addition, 55% (95% CI 43 to 67%; Figure 1C) of patients received ≥1 appropriate ICD therapy (shocks or antitachycardia pacing), 8% (95% CI 5 to 12%) received inappropriate ICD shocks, and 23% (95% CI 11 to 37%) experienced electrical storms. Conclusion Despite ICD, the mortality rate in patients with CCC remains unacceptably high, primarily driven by cardiovascular causes, with frequent appropriate ICD therapies and electrical storms. Further studies are needed to better delineate the benefits and risks of ICD therapy in patients with CCC.Figure 1
Place of Death in Ventricular Arrhythmias in the United States: A 25-Year Population-Based Analysis From 1999 2024
Naveed, Muhammad Abdullah, Razzak, Muhammad Junaid , Hasan, Muhammad, Ali, Ahila , Rehan, Maryam, Agarwal, Siddharth, Neppala, Sivaram , Deshmukh, Abhishek, DeSimone, Christopher Vincent, Munir, Muhammad Bilal, DeSimone, Christopher V. , Munir, Muhammad Bilal , DeSimone, Christopher V , Munir, Muhammad Bilal , Naveed, Muhammad Abdullah, Agarwal, Siddharth

Mayo Clinic

No container title available | January 16, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.01.14.26344154 Get It

Abstract Background Ventricular arrhythmias (VAs) are a proximate mechanism of sudden cardiac death, yet national patterns in place of death (POD) and their determinants remain sparsely described. We quantified 25-year trends and factors associated with POD among UAs decedents in the United States. Methods We analyzed CDC WONDER Multiple Cause of Death data (1999–2024) for adults ≥25 years with ventricular arrhythmias (ICD-10 I47.2, I49.0) as underlying cause. POD was categorized as inpatient, outpatient/emergency department (ED), home, hospice/nursing, or other/unknown. Covariates included age, sex, race, Hispanic origin, and urbanization. We calculated Annual and Average Annual Percent Changes (AAPCs and APC) using Age-Adjusted Mortality Rates (AAMRs), and fit multinomial logistic regression (reference = inpatient) to obtain adjusted odds ratios (ORs, 95% CIs). Results Among 433,988 ventricular arrhythmia (VA) deaths, POD was inpatient 62.0%, outpatient/ED 18.1%, home 11.1%, hospice/nursing 5.8%, other 3.1%. Inpatient deaths increased from 57.8% (1999) to 66.1% (2024). AAMRs declined sharply from 13.3 per 100,000 in 1999 to 6.3–6.5 during 2010–2019, then rose to 7.4 in 2021 and fell to 6.8 in 2024. In home vs inpatient: ≥85 years, medium/small metropolitan counties and rural counties had higher odds of VA deaths, whereas younger age groups, females, Black, American Indian, Asian/Pacific Islander individuals and Hispanic individuals had lower odds. In outpatient/ED vs inpatient: 25–44 years, 45–64 years, males, Black, American Indian and Asian/Pacific Islander individuals had higher odds, whereas ≥85 years and females had lower odds. In hospice/nursing facilities: ≥85 years, females, Whites, non-Hispanic individuals, medium/small metropolitan counties and rural counties had higher odds of VA deaths, whereas younger age groups, Black, American Indian, Asian/Pacific Islander individuals and Hispanic individuals had markedly lower odds. Conclusion From 1999–2024, VA deaths shifted toward hospitals. Persistent disparities by age, sex, race/ethnicity, and rurality highlight the need to expand equitable advance care planning and device deactivation discussions.
Clinical Characteristics of Patients With Patent Foramen Ovale and Pyogenic Brain Abscess
Abu-Zeinah, Khalid , Tabaja, Hussam , Enzler, Mark J., REEDER, GUY S., DeSimone, Daniel C. , Baddour, L.M., Saleh, Omar M Abu, Campioli, Cristina Corsini , Damronglerd, Pansachee, Tabaja, Hussam , DeSimone, Daniel C , Abu Saleh, Omar M, Corsini Campioli, Cristina , Chesdachai, Supavit , Abu-Zeinah, Khalid , Damronglerd, Pansachee , Yetmar, Zachary A. , Reeder, Guy S., Saleh, Omar Abu , Chesdachai, Supavit

Mayo Clinic

Open Forum Infectious Diseases | January 14, 2026 | Volume: 13 | Issue: 2 | Pages: No page available

10.1093/ofid/ofag026 | PMID 41635445 Get It

Abstract Patent foramen ovale (PFO) has a prevalence of approximately 25%. Its association with pyogenic brain abscess (PBA) is unclear. We reviewed adults with PBA and known PFO status from 1 January 2009 through 31 December 2021 at Mayo Clinic. High PFO prevalence (40.5%) was seen. PBA patients with PFO had distinct abscess characteristics but unchanged 1-year, all-cause mortality.
Impact of Timing of Atrial Fibrillation Ablation on AF Recurrence and Clinical Outcomes in Patients With HFpEF and HFrEF
Eisa, Mahmoud , Elbenawi, Hossam , Deshmukh, Abhishek J., DeSimone, Christopher V., DeSimone, Christopher V. , Deshmukh, Abhishek J , DeSimone, Christopher V , Deshmukh, Abhishek

Mayo Clinic

Journal of Cardiovascular Electrophysiology | January 14, 2026 | Volume: 37 | Issue: 4 | Pages: 898-899

10.1111/jce.70247 | PMID 41528062 Get It

P-73. Unique Pathogen Distribution in Patients Undergoing Chronic Antibiotic Suppression for Cardiac Implantable Electronic Device Infection
Zaslow, Shari J. , Baddour, L.M., DeSimone, Daniel C. , Chesdachai, Supavit

Mayo Clinic

Open Forum Infectious Diseases | January 12, 2026 | Volume: 13 | Issue: Supplement_1 | Pages: No page available

10.1093/ofid/ofaf695.302 Get It

Abstract Background Cardiac implantable electronic device infection (CIEDI) is a serious complication, occurring in approximately 1% of implantations. In addition to antimicrobial therapy, complete device extraction is considered essential for definitive cure. However, this may not always be feasible due to a variety of factors. In select cases, long-term chronic antibiotic suppression (CAS) has been used, yet clinical characteristics and outcomes of patients who received CAS have scarcely been reported. Methods A descriptive study analyzing all adult (age &gt; 18) patients with definite CIEDI who received CAS between 2016 and 2023 across the Mayo Clinic Enterprise (Arizona, Florida, Minnesota, and Upper Midwest) was conducted. Patients with either ventricular assist devices or fungal infection were excluded. Results A total of 321 patients were diagnosed with definite CIEDI during the study period. A total of 37 (8.7%) patients received CAS due to device retention. The median age was 77.5 [IQR 70.5, 87.5] with 32.4% female. Permanent pacemakers were involved in most (64.9%) infections. Approximately one-third (32.4%) of patients had a prosthetic valve. The median time from initial device implantation to CIEDI was 10.6 years [IQR 4.8, 18.1]. CIED-related infective endocarditis was present in 70.3% of cases and 67.6% had lead involvement. The most commonly isolated organisms were Staphylococcus aureus (29.7%), coagulase-negative staphylococci (27%), Enterococcus faecalis (13.5%) and Streptococci (13.5%). Other pathogens or culture-negative cases comprised 16.3%. The primary reason for device retention and CAS was poor surgical candidacy. Doxycycline was the most commonly used agent for CAS, accounting for 37.8% of cases. The average length of suppression was 469.0 days [IQR158.0, 1264.0]. The rate of relapse was 8.1% with all occurring within 90 days of diagnosis. One year mortality was 27.0%. Conclusion CAS may be a feasible option for patients with device retention, although a small proportion experience CIEDI relapse. Unexpectedly, the pathogen distribution among CAS recipients differed from that seen in a general CIED infection population, highlighting selection bias and the distinct clinical characteristics of patients managed with CAS. Disclosures Larry M. Baddour, MD, UpToDate, Inc.: Royalty payments (authorship duties).
P-68. Effect of hypoalbuminemia on blood culture clearance and outcomes in methicillin-susceptible Staphylococcus aureus bacteremia managed with antistaphylococcal penicillins or cefazolin
Stevens, Ryan W W, Baddour, L.M., Cole, Kristin, Kooda, Kirstin , Robinson, John, Stevens, Ryan W. , DeSimone, Daniel C. , Ilges, Dan

Mayo Clinic

Open Forum Infectious Diseases | January 12, 2026 | Volume: 13 | Issue: Supplement_1 | Pages: No page available

10.1093/ofid/ofaf695.297 Get It

Abstract Background Methicillin-susceptible Staphylococcus aureus bacteremia (MS-SAB) is treated with antistaphylococcal penicillins (ASP) or cefazolin. Altered pharmacokinetics in the setting of hypoalbuminemia may reduce the likelihood of therapeutic success in patients receiving highly protein bound beta-lactams. ASPs and cefazolin are 94% and 80% protein bound, respectively. We assessed the impact of hypoalbuminemia (≤2.5 g/dL) on clinical outcomes in patients with MS-SAB treated with ASPs or cefazolin.Table 1:Unweighted and weighted analysis of full cohort by albumin statusTable 2:Weighted analysis of cefazolin and ASP cohorts by albumin status Methods This single center, retrospective study included adults (≥18 years) admitted with community-acquired MS-SAB between 1/1/2006 and 12/31/2019 who received ASPs or cefazolin and had a serum albumin obtained between the date of first culture positivity and 72 hours of definitive therapy. Exclusion criteria included receipt of ≥5 days of MSSA active empiric therapy prior to definitive, polymicrobial bacteremia, antibiotics for an indication other than MS-SAB, or central nervous system infection. The primary outcome was failure to clear blood cultures within 72 hours of definitive therapy initiation. Propensity score weighting was used to adjust for baseline differences between cohorts. Results 160 patients were included with 61 (38.1%) being hypoalbuminemic (Table 1). In the propensity score weighted analysis, the primary outcome occurred in 37% of patients with an albumin ≤2.5 g/dL vs. 10.2% with an albumin &gt;2.5 g/dL (p&lt; 0.001). This finding was consistent in both ASP and cefazolin subgroups (Table 2). Hospital length of stay was longer in hypoalbuminemic patients but did not represent a statistically significant difference in the weighted overall analysis (15.9 vs. 11.6 days, p=0.8). There was no difference in inpatient mortality in any of the cohorts analyzed. 90-day all-cause mortality was higher in hypoalbuminemic patients only in the cefazolin subgroup analysis (20.7% vs 4.9%, p=0.019). Conclusion The presence of hypoalbuminemia was associated with failure to clear blood cultures within 72 hours of definitive therapy initiation in patients with MS-SAB. While no significant difference in mortality was observed overall, the higher mortality in the cefazolin subgroup warrants further research on the impact of hypoalbuminemia on clinical outcomes in patients with MS-SAB. Disclosures Larry M. Baddour, MD, UpToDate, Inc.: Royalty payments (authorship duties).