Citations

Clear

7552 citation(s) found for "Ku, Matthew".

Neoadjuvant Immunotherapy in Melanoma: The Paradigm Shift
Aedo-Lopez, Veronica , Block, Matthew S. , Amaria, Rodabe N. , Hieken, Tina J. , Kreidieh, Firas , McArthur, Grant A.

Mayo Clinic

American Society of Clinical Oncology Educational Book | April 28, 2023 | Volume: No volume available | Issue: 43 | Pages: No page available

10.1200/edbk_390614 | PMID 37116111 Get It

Clinical stage III melanoma, defined as resectable RECIST measurable nodal disease with or without in-transit metastases, represents approximately 15% of new melanoma diagnoses every year with additional cases presenting as recurrent nodal disease following previous treatment of a primary melanoma. The standard of care for patients with resectable clinical stage III melanoma is surgical resection, consisting of therapeutic lymph node dissection and/or resection of in-transit disease and consideration of adjuvant systemic therapy and occasionally adjuvant radiation. These patients have high rates of regional recurrence and progression to metastatic disease postsurgery, highlighting the need for better treatment options. With the success of immune checkpoint inhibitors in both the adjuvant and metastatic settings, the use of these agents in the neoadjuvant setting has been an emerging area of research interest. In this chapter, we will discuss the rationale for neoadjuvant immunotherapy; review impactful clinical trials; and define response monitoring, surgical considerations, emerging therapies, and unanswered questions for neoadjuvant therapy as a recent paradigm shift in the management of clinical stage III melanoma.
Age and Sex Distributions of MOG-IgG and AQP4-IgG Positive Sera from a Large Neuroimmunology Laboratory Database (P2-5.028)
Vorasoot, Nisa , Kunchok, Amy , Edmond, Matthew C., McCombe, Jennifer A. , Redenbaugh, Vyanka , Tisavipat, Nanthaya , Abdulrahman, Yahya, Chen, John , Irani, Sarosh R. , Irani, Sarosh R , Pittock, Sean J , Vorasoot, Nisa , Tisavipat, Nanthaya , Cacciaguerra, Laura , Thakolwiboon, Smathorn , Pittock, Sean J. , Flanagan, Eoin P.

Mayo Clinic

Neurology | April 28, 2023 | Volume: 100 | Issue: 17_supplement_2 | Pages: No page available

10.1212/wnl.0000000000204098 Get It

Impact of Artificial Intelligence System and Volumetric Density on Risk Prediction of Interval, Screen-Detected, and Advanced Breast Cancer
Vachon, Celine M. , Scott, Christopher G. , Norman, Aaron D. , Khanani, Sadia, Jensen, Matthew R. , Hruska, Carrie B. , Brandt, Kathleen R. , Winham, Stacey J. , Kerlikowske, Karla , Khanani, Sadia A, Winham, Stacey J , Hruska, Carrie B , Scott, Christopher , Norman, Aaron D , Kerlikowske, Karla M , Vachon, Celine M.

Mayo Clinic

Journal of Clinical Oncology | April 27, 2023 | Volume: 41 | Issue: 17 | Pages: 3172-3183

10.1200/jco.22.01153 | PMID 37104728 Get It

PURPOSE Artificial intelligence (AI) algorithms improve breast cancer detection on mammography, but their contribution to long-term risk prediction for advanced and interval cancers is unknown. METHODS We identified 2,412 women with invasive breast cancer and 4,995 controls matched on age, race, and date of mammogram, from two US mammography cohorts, who had two-dimensional full-field digital mammograms performed 2-5.5 years before cancer diagnosis. We assessed Breast Imaging Reporting and Data System density, an AI malignancy score (1-10), and volumetric density measures. We used conditional logistic regression to estimate odds ratios (ORs), 95% CIs, adjusted for age and BMI, and C-statistics (AUC) to describe the association of AI score with invasive cancer and its contribution to models with breast density measures. Likelihood ratio tests (LRTs) and bootstrapping methods were used to compare model performance. RESULTS On mammograms between 2-5.5 years prior to cancer, a one unit increase in AI score was associated with 20% greater odds of invasive breast cancer (OR, 1.20; 95% CI, 1.17 to 1.22; AUC, 0.63; 95% CI, 0.62 to 0.64) and was similarly predictive of interval (OR, 1.20; 95% CI, 1.13 to 1.27; AUC, 0.63) and advanced cancers (OR, 1.23; 95% CI, 1.16 to 1.31; AUC, 0.64) and in dense (OR, 1.18; 95% CI, 1.15 to 1.22; AUC, 0.66) breasts. AI score improved prediction of all cancer types in models with density measures ( P LRT values < .001); discrimination improved for advanced cancer (ie, AUC for dense volume increased from 0.624 to 0.679, Δ AUC 0.065, P = .01) but did not reach statistical significance for interval cancer. CONCLUSION AI imaging algorithms coupled with breast density independently contribute to long-term risk prediction of invasive breast cancers, in particular, advanced cancer.
Using 3D printed structures to evaluate the potential causes of the color Doppler twinkling signature
Wood, Benjamin , Saracaydin, Renc, Lee, Christine U. , Lee, Christine, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A355-A355

10.1121/10.0019138 Get It

The color Doppler twinkling artifact has been attributed to existing microbubbles or cavitation occurring on objects like kidney stones, some breast biopsy markers, and sandpaper. The grooves of helical constructs that twinkle may provide sufficient locations for bubble retention and/or cavitation. We developed six half-cylinders that replicate the geometry of twinkling helical constructs with a micro 3D-printing process to explore how their characteristics relate to twinkling. Four copies of each design including a control were created. The cylinders had pitch (groove-to-groove distance) of 87.5–343 μm and amplitude (groove depth) of 41.5–209 μm. The cylinders were submerged in degassed water and optically imaged before and after ultrasound to visualize bubbles on the cylinders. The cylinders remained submerged while scanning with color Doppler at frequencies from 3.1 to 6.3 MHz with a General Electric Logiq E9 scanner and 9L linear array transducer. Two designs that showed twinkling characteristics were further examined. The presence or absence of bubbles on these designs was confirmed with microscopy, and the resulting twinkling behavior was investigated. This work shows strong evidence that both existing visible bubbles and either cavitation or ultrasound wave interactions with patterned or rough surfaces are significant factors in producing the twinkling signature.
Limitations of the Caputo time-fractional wave equation when applied to shear waves in pig liver
McGough, Robert J., Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A312-A312

10.1121/10.0018969 Get It

When applied to compressional waves, the Caputo time-fractional wave equation describes power law attenuation in soft tissue. However, when applied to shear waves, the Caputo wave equation produces some unexpected behavior. To demonstrate examples of the time-domain waveforms generated by this fractional calculus model, the Caputo wave equation is numerically evaluated for multiple orders of the time-fractional derivative between 0 and 1, for an extended range of values for the relaxation time, and for a fixed value of the shear wave speed extracted from ex vivo pig liver. The computed waveforms are then compared to the measured shear wave particle velocities obtained from ex vivo pig liver. These comparisons reveal that the full-width at half maximum (FWHM) of the positive component of the main shear wave particle velocity waveform measured in pig liver is at least an order of magnitude greater than the FWHM obtained from the Caputo wave equation for all parameter combinations evaluated. These preliminary results indicate that the Caputo wave equation produces time-domain waveforms that are inconsistent with measured shear wave data in pig liver and that further efforts are required to establish more effective fractional calculus models for shear waves in soft tissue.
Parametric evaluation of Kelvin-Voigt dispersion curve fitting
Vasconcelos, Luiz, Kijanka, Piotr , Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A313-A313

10.1121/10.0018970 Get It

Ultrasound shear wave elastography (SWE) is a useful technique for non-invasive tissue assessment. For effective quantitative analysis the employment of physical models is necessary for rheological parameter estimation, such as the Kelvin-Voigt (KV) model. From SWE data, the frequency response can be calculated, and the shear wave velocity dispersion can be fit, yielding the shear elasticity and shear viscosity, μ1 and μ2, respectively. In this study, a parametric evaluation is performed using staggered-grid finite-difference simulations of materials with μ1 = 1–25 kPa (increment: 1 kPa) and μ2 = 0–10 Pa s (increment: 0.5 Pa s), with an acoustic radiation force push of f-number equal to 2. The novel Stockwell transform combined with a slant frequency-wavenumber analysis (GST-SFK) was compared with the two-dimensional Fourier transform for dispersion curve estimation over a variety of frequency ranges. Regardless of dispersion curve estimation technique, the accuracy of estimating μ1 is confounded for μ2 values above 5 Pa s. It was found that KV fitting benefits from wider frequency ranges (up to 1kHz), with lower μ1 and μ2 estimation errors. The GST-SFK was the best dispersion curve calculation technique, yet the KV fitting process was found to be unreliable for parameter estimation in highly viscous media.
Nonlinear least-squares estimation of shear modulus and shear viscosity in viscoelastic media
Bannon, Nicholas A., McGough, Robert J., Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A313-A313

10.1121/10.0018971 Get It

Time-domain estimates of the shear wave speed are obtained by performing cross-correlations or by evaluating the time-to-peak for two laterally separated shear wave particle velocity waveforms, where the distance divided by the propagation time yields an approximate value for the shear wave speed. Challenges associated with these time-domain estimation approaches include increasing errors as the shear viscosity increases and the absence of an estimated value for the shear viscosity parameter which is responsible for the rapid attenuation of shear waves in soft tissue. To obtain a time-domain estimate of the shear viscosity that also provides an estimate for the shear wave speed, a nonlinear least squares estimation approach is applied to three-dimensional (3D) shear wave particle velocities computed for a shear elasticity of 1.5 kPa, shear viscosities of 1, 2, 3, and 4 Pa.s, and a realistic simulated 3D acoustic radiation force excitation. The results show cross-correlations tend to over-estimate the value of the shear wave speed, the nonlinear least squares approach tends to under-estimate the value of the shear wave speed, and the nonlinear least square approach produces more accurate estimates as the shear viscosity increases. Two-dimensional maps of each estimated parameter are also shown.
Shear wave elastography: From dispersion matching to full waveform inversion
Guddati, Murthy N. , Elmeliegy, Abdelrahman , Roy, Tuhin, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A265-A265

10.1121/10.0018796 Get It

Shear Wave Elastography (SWE) involves estimating mechanical properties through inversion, i.e., matching measured and simulated propagation characteristics of shear waves in the tissue. The accuracy of the estimated properties depends significantly on the specific characteristics/responses that are being matched. These could range from simple group velocity to dispersion curves and to full-wave response (particle velocity measurements). Using specific applications of arterial, liver, and tumor elstography, we illustrate that effective SWE is performed by resorting to an inversion approach, or combination of inversion approaches, guided by the underlying physics. To this end, we present inversion approaches ranging from matching dispersion characteristics to matching full waveform responses and provide rationale for choosing the appropriate technique(s) depending on the problem at hand.
Improving group velocity based estimates of arterial stiffness
Capron, Charles , Guddati, Murthy N. , Roy, Tuhin, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A266-A266

10.1121/10.0018801 Get It

Arterial stiffness is a predictor of cardiovascular diseases, the leading causes of death worldwide. Ultrasound-based methods that measure arterial wave propagation have promise for evaluating local stiffness in vivo. However, geometric properties of arteries cause dispersion, invalidating typical assumptions underlying the relationship between shear modulus G and group velocity cg, which clinical implementations of ultrasound shear wave elastography do not consider. Here, we examine the dependence of these estimates on geometry and evaluate alternative approaches. Wave motion in the proximal wall of an artery after application of focused acoustic radiation force is simulated with a semi-analytical finite element (SAFE) model, and cg is estimated using a time-to-peak algorithm to determine G with several methods. First, the value of G a clinical scanner would report is calculated assuming a bulk medium. Second, a pulse wave velocity (PWV)-based G estimate is calculated by taking cg = PWV and applying the Moens–Korteweg equation. Third, we develop an interpolation-based method to provide a corrected G estimate using data generated by the SAFE model. Simulation results show severe geometry-dependent bias with the bulk method, which is partially ameliorated with the PWV method and substantially improved with the interpolation approach. Results are validated using arterial phantoms.
Crosstalk analysis of comb detection for measuring shear wave propagation
Lee, Hyungkyi, Holmes, Philip M. , Greenleaf, James F. , Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | April 26, 2023 | Volume: 153 | Issue: 3_supplement | Pages: A266-A266

10.1121/10.0018802 Get It

Applications, such as shear wave elastography and Doppler imaging, require high frame rates. Plane wave compounding (PWC) is widely used for these applications. Comb detection was proposed to combine the high frame rate of PWC and the high signal quality of focused beam scanning. Comb detection transmits multiple focused beams simultaneously to increase the frame rate. These comb beams are scanned laterally to cover the whole region-of-interest. The simultaneous multiple transmission of focused beams causes crosstalk between neighboring beams. Transmit crosstalk is related to the pressure field of transmit beams, and receive crosstalk is determined by the beam profile of receive beamforming. In this study, we varied f-number (F/N) and apodization window and measured their effects on crosstalk based on the pressure field and an arterial wall simulation using Field II. For transmit design, transmit apodization with a Hamming window significantly reduced crosstalk compared to a rectangular window and transmit F/N had little impact on the crosstalk. Regarding receive beamforming, a Hamming window led to lower crosstalk than the rectangular window and F/N from 1 to 5 suppressed crosstalk to below 30 dB. The effects of crosstalk in shear wave motion data from phantom experiments were also analyzed. Comb detection showed less motion artifact than PWC in phantom experiments.