Abstract The highest risk for liver allograft rejection is within the first weeks to months after a liver transplant; however, while later-stage mechanisms are well described, the initial window at the moment of alloantigen influx (e.g., ~ 1 h post-reperfusion) remains unmapped. T-cell priming is initiated in lymph nodes, yet these sites are rarely profiled in humans and their relationship to rejection risk is unclear. To address this gap, we profiled paired pre- and ~ 1 h post-reperfusion hepatic draining lymph nodes from liver transplant recipients using multiplexed immunofluorescence and GeoMx whole-transcriptome profiling to identify features that predict rejection versus non-rejection. Early after reperfusion, CD4 + and CD8 + T cells became proximal to macrophages in rejection compared to dendritic cells in non-rejection, which also displayed an immunoregulatory-leaning profile marked by PD-1, IDO1, and CD39, suggesting that macrophages and dendritic cells differentially influence early T-cell alloimmunity. These results provide nodal targets for precise immune modulation.
Autosomal Recessive PKD: Not Just for Kids, Long-Term Outcomes in Early vs. Late-Onset Disease
Background: Patients performing self-triage for chest pain need to pick an algorithm which includes questions pertinent to chest pain to triage accurately. Objective: Our study reviews patient self-triage choices and outcomes for patients who completed an online self-triage encounter before being triaged by a nurse for chest pain. Methods: Patients who underwent telephone nurse triage for chest pain, and also had an online self-triage encounter within the prior 24 hours were reviewed for the frequency with which they chose “chest pain” as their symptom to triage for during self-triage, whether they reported chest pain during the self-triage encounter (if asked as part of the algorithm for their chosen self-triage symptom) and whether the patient had any follow up evaluation within 1 week. Results: There were 70 self-triage and nurse triage dyads during the study period where triage nurses chose “chest pain” as the primary symptom to be triaged for during the telephone triage encounter. Of these, only 5 (7.1%) patients chose the “chest pain” self-triage option during online self-triage. During the self-triage encounter, 50 (71%) reported chest pain, 10 (14%) denied chest pain and 10 chose to self-triage their symptoms with an algorithm that did not include a question on whether chest pain was present. Of the 70 total dyads 59 (84%) had a follow up emergency department (40 patients) or office visit (19 patients) documented. Conclusion: Most patients chosen to be triaged for chest pain by triage nurses did not choose the online self-triage algorithm for chest pain even though the majority did report chest pain during their self-triage encounter (when asked). This is concerning from a safety perspective as a non-chest pain self-triage option chosen by the patient may not always ask about the presence or absence of chest pain and thus could increase the risk of being triaged inaccurately. Implications for improvement of self-triage could include diagrams for patients to choose the symptom area.
Relevance of Lesion Volume as an Outcome in Cerebral Cavernous Malformation Drug Trial: Exploratory Analyses in Atorvastatin Treatment of Cavernous Angiomas with Symptomatic Hemorrhage Exploratory Proof of Concept
BACKGROUND AND OBJECTIVES: It is not clear whether changes in lesion volume might represent a clinically relevant and statistically advantageous outcome parameter in early phase trials aimed at preventing bleeding in cerebral cavernous malformations (CCM). METHODS: We examined prospective changes in CCM lesion volume in the double-blinded AT CASH EPOC trial (clinicaltrials.gov NCT02603328). We correlated these with symptomatic hemorrhage (SH) events, contemporaneously assessed changes in lesional iron content by quantitative susceptibility mapping (QSM) on MRI, and objective (modified Rankin Scale (mRS)) and subjective (Euro-QoL Visual Analog Scale [EQ-VAS]) functional status. We also simulated sample sizes needed to detect potential effects on lesion volume. RESULTS: There was excellent correlation between independently assessed maximum lesion diameter and CCM lesion volume (R 2 = 0.68, P < .0001). The mean (SD) percentage change in lesion volume per year was +6 (65) and +18 (94) in atorvastatin and placebo patients, respectively ( P = .43). All cases with SH had increases in lesion volume and increases in mean lesional iron content by QSM, and most had declines in functional status on mRS and EQ-VAS, but there were no overall meaningful correlations of changes in lesion volume with concomitant changes in mean lesional QSM, mRS, or EQ-VAS (all R/R 2 < 0.5 and Bonferroni corrected P > .05), including in brainstem lesions analyzed separately. Sample size simulations indicate larger case numbers needed to demonstrate an effect on change in lesion volume than those needed to detect an effect on QSM change with α = 0.05 and β = 0.8, and even larger samples to detect effects on the number of cases with increased or decreased lesion volume. CONCLUSION: Changes in lesion volume occur frequently in CCM lesions after recent SH, but do not correlate with biomarkers of lesional bleeding, nor reflect functional changes, and are not statistically advantageous compared with QSM measures in detecting potential drug effects.
Accelerating eSource scale-up in oncology clinical trials: The i~HD Task Force initiative
Abstract eSource – particularly EHR-to-EDC – is an emerging paradigm in clinical research that enables automated transfer of electronic health record (EHR) data into electronic data capture (EDC) systems, with the potential to reduce site burden, improve data quality and accelerate oncology clinical trial workflows. However, widespread implementation remains limited due to technical, regulatory and operational barriers. To address these challenges, the European Institute for Innovation through Health Data (i~HD) launched the eSource Scale-Up Task Force in 2024. This multi-stakeholder initiative brings together leading oncology centres and pharmaceutical sponsors to establish a consensus-driven roadmap for eSource adoption. Central to this effort are three foundational resources: readiness criteria for early adopters, a performance indicator framework for monitoring success and an operational playbook to guide implementation. This article provides a structured overview of the Task Force’s objectives, collaborative model and outputs, with specific attention to its focus on interoperability, regulatory alignment and real-world validation. While initially developed for oncology, the Task Force’s framework is applicable across therapeutic areas characterized by data-intensive workflows.
Adaptation and Performance of the Self‐Report‐Generated Charlson Comorbidity Index in the Lymphoma Epidemiology of Outcomes (LEO) Cohort
ABSTRACT Newly diagnosed patients with non‐Hodgkin lymphoma (NHL) often have a history of other diseases, and these comorbidities can impact patient treatment and management options, as well as overall survival (OS). We developed the Lymphoma Epidemiology of Outcomes (LEO) comorbidity index (LCI) as a sum of 10 comorbidities adapted from the Self‐Report‐Generated Charlson Comorbidity Index (SRG‐CCI) for use in the LEO cohort, a national prospective study of newly diagnosed NHL. Of the 5502 participants with self‐reported comorbidity data, 3107 (56.4%) were male and the mean age at diagnosis was 60.9 years (range, 18–99 years). The LCI ranged from 0 to 6, with 48.6% having 0, 30.2% having 1, 21.2% having 2 or more comorbidities. With a median follow‐up of 62.4 months among surviving participants, 2099 patients had an event and 1219 died. Continuous LCI similarly predicted both 1‐year mortality (c‐statistic = 0.654) and OS (c‐statistic = 0.655), while it showed a weaker but still statistically significant predictive ability for lymphoma‐specific (c‐statistics = 0.617) and event‐free (c‐statistic = 0.574) survival. Participants with 1 (HR = 1.21, 95% CI 1.05–1.39) and 2+ (HR = 1.80, 95% CI 1.56–2.08) comorbidities had inferior OS compared to those with no comorbidities after adjustment for age and sex (c‐statistic = 0.654), and performance strengthened after adjustment for the International Prognostic Index (c‐statistic = 0.672). LCI predicted OS most strongly in marginal zone (c‐statistics = 0.748) and weakest in T‐cell (c‐statistic = 0.579) lymphoma. The cumulative incidence of death due to lymphoma, lymphoma treatment, and other causes all increased with increasing comorbidities, with the greatest increase observed for death due to other causes. The LCI performs comparable to other published comorbidity indices, supporting its use in the LEO cohort to better model real‐world outcomes and more generally providing an approach to implementing comorbidity indices in cancer survivorship cohorts.
B-094 Evaluating the Impact of Stabilized Calibrator on Free Light Chains Reference Intervals
Abstract Background The Freelite serum free light chain (FLC) assay has been widely used for detecting and monitoring monoclonal gammopathies. Reference intervals (RIs) established by Katzmann et al. in 2002 have served as the standard values for interpreting kappa/lambda FLC ratios. However, multiple reports suggested an assay drift and clinical laboratories started to move towards locally established RIs given the challenge in verifying original RIs. The assay drift over time increased kappa concentration measurements and was attributed to an interaction between the kappa FLC calibrator and serum proteins, including alpha-1-antitrypsin. A stabilized calibrator was developed to improve consistency of results with original RI. The objective of this study was to assess whether the new updated kappa calibrator would warrant a RI update. Methods Healthy adult donors’ serum samples were selected from the institution quality unit. Exclusion criteria included autoimmune diseases, cancers and renal disease. FLC measurements were obtained on the Optilite by turbidimetry using routine reagents for kappa (old lot); the new lot of reformulated kappa calibrator, and a single measurement for lambda FLC. FLC ratios were calculated with the old lot and new lot. All samples were tested by MASS-FIX to confirm absence of a monoclonal protein. Bootstrap resampling (10,000 replicates) estimated standard errors, with statistical significance defined as p < 0.05. Clinical significance was assessed per CLSI EP28-A3 guidelines. A RI was considered for partitioning by sex if the mean difference between males and females exceeded 25% of the RI width or if >4% of either sex had values beyond RI limits. Similar tests were applied to age groups (<60 and =60 years). Results 465 donors (48.2% male, 51.8% female) aged 30-89 years were used. Sixteen donors with incidental monoclonal proteins identified by MASS-FIX were excluded, for a final n=449. No clinically significant relationships of results were found with sex or age. The updated kappa calibrator resulted in a measurable shift down in FLC values with the new lot of reagents. The kappa FLC concentration and corresponding FLC ratio decreased by a median -12.1%, see table 1 for absolute values When reviewing Optilite results of the new lot, 98/449 samples were outside the kappa concentration original RI (21%). Lambda concentration RI was shifted up on Optilite when compared to original RI but passes verification (1.6% of samples, acceptance criteria < or =10%). 19 samples (4.2%) were outside the original RI for the FLC ratio of 0.26 to 1.65 (all >1.65), which was originally established as a 100% diagnostic range. The calibrator reformulation, while decreasing test results by >10%, was not sufficient to verify the original RI for kappa and still left a few cases outside the original diagnostic range for the FLC ratio. Conclusion This study assessed the impact of the stabilized calibrator on RIs for the Optilite Freelite assay. These findings suggest revisiting existing RIs to ensure continued accuracy in clinical interpretation and should be further evaluated with additional lots of reagents for robustness.
A-193 It Started with Tape: Empowering Technologists on a Journey of Innovation and Safety in Cryoglobulin Testing
Abstract Background Cryoglobulins are immunoglobulins that precipitate at cold temperatures. They are associated with plasma cell disorders, infectious and autoimmune diseases. Laboratory testing is manual and requires strict temperature control, from keeping the blood sample warm from the moment of draw until processing in the laboratory. Serum samples are transferred to Kolmer glass graduated tubes upon arrival, and kept on ice for visualization of a precipitate for up to 7 days. Because of the temperature variation samples are subjected to, positive sample identification is important. The Kolmer glass tubes are not disposable, and undergo several steps of deidentification and cleaning for reuse. The goal of this project was to improve patient safety and label adherence in cryoglobulin testing by using the Managing for Daily Improvement (MDI) method to monitor and implement changes effectively. Methods During a Plan Do Study Act (PDSA) initiative, it was discovered that labels were not being secured on both ends with tape due to safety concerns when using a box cutter to remove the label prior to cleaning. This practice led to an increase in labels detaching from the glass tubes. To address this issue, we employed the MDI method and established a Key Performance Indicator (KPI) to monitor and evaluate potential changes aimed at improving label adherence. The MDI method facilitates problem-solving through daily visual indicators and discussions by empowering technologists to identify and address issues affecting daily operations. This approach encourages open communication and collaborative problem-solving, allowing the entire team to share insights and solutions in real time. Results A PDSA initiative via MDI uncovered the label adherence challenges. A KPI was developed to monitor interventions to improve the process. First, removable tape was used to secure both sides of the label. Initial results were worse than the original method but slight improvement occurred at about 3 weeks. A Just Do It (JDI) approach was initiated to leave additional space between samples. No improvements were observed and the practice discontinued within < 2 weeks. A second JDI was trialed with a different tool to remove labels post-use. The entire sample identification process was reviewed and the original identification process resumed, by adding scotch tape securing both sides of the labels and using a ceramic box cutter to remove the labels. Significant improvements to labels adherence was observed, from about 60% of labels coming off to zero, while the new tool was also safer for the team. Another PDSA was initiated to investigate if plastic, disposable tubes were a viable option for testing, and a full method validation of the new plastic tubes followed, finally eliminating the challenges with the larger process or reusing glass tubes. Conclusion MDI helped recognize a problem from the front-line and find real time solutions that benefited end-to-end operations. Visual daily indicators clearly showed effectiveness of interventions. Identifying real issues, even if they appear small, can lead to improved patient and staff safety, and empowerment to initiate meaningful change.
ER stress upregulates S100A11 in steatohepatitis models via epigenetic modifications within the lipotoxicity-influenced enhancer
Metabolic dysfunction–associated steatohepatitis (MASH) is a progressive liver disease characterized by complex interactions between lipotoxicity, ER stress responses, and immune-mediated inflammation. We identified enrichment of the proinflammatory alarmin S100 calcium-binding protein A11 (S100A11) on extracellular vesicles stimulated by palmitate-induced lipotoxic ER stress with concomitant upregulation of hepatocellular S100A11 abundance in an IRE1A-XBP1s–dependent manner. We next investigated the epigenetic mechanisms that regulate this stress response. Publicly available human liver ChIP-Seq GEO datasets demonstrated a region of histone H3 lysine 27 (H3K27) acetylation upstream of the S100A11 promoter. H3K27 acetylation ChIP-qPCR demonstrated a positive correlation between lipotoxic ER stress and H3K27 acetylation of the region, which we termed the lipotoxicity-influenced enhancer (LIE) domain. CRISPR-mediated repression of the LIE domain reduced palmitate-induced H3K27 acetylation and corresponding S100A11 upregulation in Huh7 cells and immortalized mouse hepatocytes. Silencing of the murine LIE in 2 independent steatohepatitis models demonstrated reduced S100a11 upregulation and attenuated liver injury. We confirmed H3K27 acetylation and XBP1s occupancy at the LIE domain in human MASH liver samples and an increase in hepatocyte-derived S100A11-enriched extracellular vesicles in MASH patient plasma. Our studies demonstrate a LIE domain that mediates hepatic S100A11 upregulation. This pathway may be a potential therapeutic target in MASH.
Magnetic Resonance Spectroscopy of 2‐Hydroxyglutarate and Glycine in Adult Subjects With Brainstem Gliomas
ABSTRACTSurgical biopsy of brainstem tumors carries a risk of neurological injury. We performed magnetic resonance spectroscopy (MRS) of 2‐hydroxyglutarate (2HG) and glycine in patients with brainstem tumors to assess the feasibility of detecting and quantifying 2HG in the brainstem to obviate the need for a diagnostic biopsy and to establish the clinical significance of glycine MRS in brainstem tumors in vivo. Twenty adult patients with radiographically identified presumed brainstem gliomas were prospectively enrolled in the study. Proton MRS was obtained at 3T with a protocol tailored for detection of 2HG and glycine (TE 97‐ms PRESS). Spectra were fit using LCModel software and in‐house basis signals of metabolites and lipids. The metabolite concentrations were quantified with reference to water and examined with respect to clinical outcomes, including postgadolinium MRI and overall survival time. MRS data from 19 patients were included in subsequent analysis, excluding suboptimal data from one patient. Tumors with elevated 2HG (> 1.9 mM, N = 8) and undetectable 2HG (< 0.3 mM, N = 11) were clearly distinguishable. Tumors with elevated glycine (> 1.5 mM, N = 4) showed rapid progression. Kaplan–Meier survival analyses with metabolite measures demonstrated that tumors with 2HG higher than 1.0 mM were significantly associated with a favorable prognosis (p = 0.01). In contrast, tumors with glycine higher than 2.5 mM showed a strong association with poor survival (p = 0.0005). The data confirm detection of 2HG in brainstem tumors at a concentration that is consistent with an IDH mutation and expected good prognosis, whereas elevated glycine in brainstem tumors portends rapid tumor progression and a worse prognosis.