Back to Authors

Copet, Brandon

A5119809882 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 2

B-123 Clinical Implication of Light Chain Fragmentation in Patients with Monoclonal Gammopathies

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.520

Abstract Background The diagnosis of monoclonal gammopathies relies on the detection of monoclonal immunoglobulins (M-proteins) in serum or urine. Mass-Fix utilizes matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) to detect and quantify M-proteins. This method employs immunoaffinity enrichment using antibodies against heavy chains (HC) and light chains (LC), followed by MS analysis to determine M-protein isotypes. Mass-Fix has also revealed novel M-protein characteristics, including LC glycosylation and fragmentation, facilitated by measuring the mass of LC. LC glycosylation is as an independent risk factor for disease progression of monoclonal gammopathy of undetermined significance (MGUS), while light chain fragments have been postulated as the origin of amyloid light chain (AL) plaques. Since Mass-Fix enriches intact immunoglobulins before dissociating LCs, it potentially enhances fragment detection. However, the precise nature and clinical significance of these fragments remain to be fully elucidated. Methods Mass-Fix serum results from Mayo Clinic patients tested from September 10, 2018, to October 1, 2024, were reviewed for the presence of M-protein and LC fragments. The frequency and the isotype of fragment LC fragments was determined in the M-protein positive cohort (n=15410). Patients diagnosed with either MGUS (n=6996), AL amyloidosis (n=315), or both (n=32) who had positive M-protein results on Mass-Fix, either prior to or within one month after the diagnosis, were included for a retrospective clinical association study of LC fragments and disease. To validate that these fragments were not artifacts of MS analysis, PAGE gel analysis and Western blots were performed using clinical residual serum from 9 patients: 2 IgG/kappa and 3 IgG/lambda patients with detectable LC fragments and 2 IgG/kappa and 2 IgG/lambda patients without fragments. Samples were purified using antibodies against gamma heavy chains and reduced with TCEP prior to gel electrophoresis and Western blot. Results Of the 15410 patients with monoclonal proteins detected by Mass-Fix, 2896 (18.7%) had detectable LC fragments; kappa fragments in 1533 and lambda fragments in 1363. Most often, the fragments were observed in pairs, with combined molecular weight typically equaled that of the full-length monoclonal LC present in the same sample. LC fragments were observed more frequently among patients diagnosed with AL amyloidosis (118/347=34%) compared to those without the diagnosis (685/6996=10%), with an odds ratio of 4.75 (95% CI, 3.75-6.01). PAGE with Coomassie blue staining revealed bands with sizes representing LC fragments in the five M-protein samples with detectable LC fragments on Mass-Fix, while no such bands observed in those without LC fragments. Western blot using anti-kappa or anti-lambda antibodies confirmed the identity of the bands with higher molecular weight as a fragment of LC in each of the IgG/kappa and IgG/lambda samples. Conclusion Mass-Fix is able to discriminate LC fragments from intact LC based on their sizes. The detection of LC fragments with Western blot without ionization suggests a biological origin rather than analytical artifacts from MS. The clinical association study suggests that LC fragments may have utility in increasing the suspicion of AL amyloidosis in M-protein positive patients with LC fragments, potentially facilitating earlier intervention and improving patient outcomes.
B-094 Evaluating the Impact of Stabilized Calibrator on Free Light Chains Reference Intervals

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.492

Abstract Background The Freelite serum free light chain (FLC) assay has been widely used for detecting and monitoring monoclonal gammopathies. Reference intervals (RIs) established by Katzmann et al. in 2002 have served as the standard values for interpreting kappa/lambda FLC ratios. However, multiple reports suggested an assay drift and clinical laboratories started to move towards locally established RIs given the challenge in verifying original RIs. The assay drift over time increased kappa concentration measurements and was attributed to an interaction between the kappa FLC calibrator and serum proteins, including alpha-1-antitrypsin. A stabilized calibrator was developed to improve consistency of results with original RI. The objective of this study was to assess whether the new updated kappa calibrator would warrant a RI update. Methods Healthy adult donors’ serum samples were selected from the institution quality unit. Exclusion criteria included autoimmune diseases, cancers and renal disease. FLC measurements were obtained on the Optilite by turbidimetry using routine reagents for kappa (old lot); the new lot of reformulated kappa calibrator, and a single measurement for lambda FLC. FLC ratios were calculated with the old lot and new lot. All samples were tested by MASS-FIX to confirm absence of a monoclonal protein. Bootstrap resampling (10,000 replicates) estimated standard errors, with statistical significance defined as p < 0.05. Clinical significance was assessed per CLSI EP28-A3 guidelines. A RI was considered for partitioning by sex if the mean difference between males and females exceeded 25% of the RI width or if >4% of either sex had values beyond RI limits. Similar tests were applied to age groups (<60 and =60 years). Results 465 donors (48.2% male, 51.8% female) aged 30-89 years were used. Sixteen donors with incidental monoclonal proteins identified by MASS-FIX were excluded, for a final n=449. No clinically significant relationships of results were found with sex or age. The updated kappa calibrator resulted in a measurable shift down in FLC values with the new lot of reagents. The kappa FLC concentration and corresponding FLC ratio decreased by a median -12.1%, see table 1 for absolute values When reviewing Optilite results of the new lot, 98/449 samples were outside the kappa concentration original RI (21%). Lambda concentration RI was shifted up on Optilite when compared to original RI but passes verification (1.6% of samples, acceptance criteria < or =10%). 19 samples (4.2%) were outside the original RI for the FLC ratio of 0.26 to 1.65 (all >1.65), which was originally established as a 100% diagnostic range. The calibrator reformulation, while decreasing test results by >10%, was not sufficient to verify the original RI for kappa and still left a few cases outside the original diagnostic range for the FLC ratio. Conclusion This study assessed the impact of the stabilized calibrator on RIs for the Optilite Freelite assay. These findings suggest revisiting existing RIs to ensure continued accuracy in clinical interpretation and should be further evaluated with additional lots of reagents for robustness.