Abstract 268: Improvements in Emergency Department CPR Quality Utilizing Real-Time Audiovisual CPR Feedback
Crowe, Christopher, Bronnenkant, Tyler, Silver, Annemarie, Hefner, Marcia, Vadeboncoeur, Tyler F. , LoVecchio, Frank , Stolz, Uwe, Bobrow, Bentley J., Crowe, Christopher, Spaite, Daniel W.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 128 | Issue: suppl_22 | Pages: No page available

10.1161/circ.128.suppl_22.a268 Get It

Background: CPR quality is closely linked to outcome in cardiac arrest. The AHA 2010 Guidelines recommend monitoring CPR quality performed by healthcare providers both inside and outside the hospital. However, most EDs currently do not monitor CPR quality. The goal of the present investigation was to assess the quality of CPR performed in an urban ED and determine the influence of training and real-time audiovisual feedback (RTAVF) on CPR quality and patient outcome. Methods: CPR quality was monitored using an R Series defibrillator (ZOLL Medical) during the treatment of adult cardiac resuscitation attempts. During phase 1 (P1; 11/2010-11/2012), real-time audiovisual chest compression feedback was disabled. During phase 2 (P2; 11/2012-3/2013), clinicians underwent a 60 minute didactic/hands-on CPR training session after which the RTAVF and the ECG artifact filtering feature were enabled. CPR quality data (fraction, depth, rate, release, peri-shock pause) were reviewed using Code Review software (ZOLL Medical). Student’s t-test and Wilcoxon-signed rank test were employed. Results: A total of 44 OHCA patients were treated in P1 (mean age 57±18 yrs, 59% male) and 24 in Phase 2 (mean age 63±15 yrs, 88% male). The majority of patients (89% P1; 96% P2) suffered prehospital arrest and were transported to the ED. Chest compression (CC) depth increased from 1.8±0.5 inches in P1 to 2.3±0.4 in P2 (p<0.001), with the percentage of compressions exceeding 2 inches more than doubling from 36% in P1 to 79% in P2 (p<0.001). CC release velocity increased from 1.25±0.36 inch/sec in P1 to 1.69±0.28 in P2 (p<0.001). No significant differences were identified in CC rate (125±12 cpm P1 vs. 121±15 cpm P2, p=0.3) or CC fraction (82% P1 vs. 87% P2, p=0.1). Pre-shock pause (11.5±10.4 sec P1 vs. 8.0±6.2 P2, p=0.4) and post-shock pause (5.2±3.4 sec vs. 3.8±0.6, p=0.9) were statistically similar in P1 and P2. Conclusion: The bundle of real time audiovisual CPR feedback and training were associated with an improvement in chest compression depth and recoil and closer adherence to guidelines for CPR quality in this large urban ED.
Abstract 18059: Utility of Infarct Edge Homogenization in Controlling Ventricular Tachycardia in Patients With Underlying Ischemic Heart Disease
Mulpuru, Siva K. , Monahan, Kristi H. , Friedman, Paul A. , Packer, Douglas L. , McLeod, Christopher J.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 128 | Issue: suppl_22 | Pages: No page available

10.1161/circ.128.suppl_22.a18059 Get It

Introduction: Point source ablation may be effective in eliminating stable ventricular tachycardia (VT), where actual mapping and ablation are possible. Ablating patients with unstable VT is more complicated and may require aggressive intervention. While small linear lesions have been utilized, the actual utility of longer linear homogenization for eliminating ventricular arrhythmias has not been examined. Methods: Therefore, the results of 86 patients undergoing VT ablation at Mayo Clinic were examined. 42 had underlying ischemic heart disease with an EF of 33.5 ± 16.8 had VT with a cycle length of 326 ± 165 ms, and had 2.5± 1.6 episodes of VT in the preceding three months. 32 required shocks for that tachycardia. Results: Of these, 21 patients (16 male, 5 female Age 67±18) underwent detailed linear ablation at the scar margin in an effort to homogenize that region. This was drawn into the infarct scar by decreasing the upper voltage boundary to 2.0. In these patients, 18 showed elimination of clinical VT. In addition, 12 showed a decrease in VT from 10 ± 8.7 episodes down to 2.5 ± 1.2 episodes of actual ventricular arrhythmias. The shock requirement decreased from 8.6 ±4.7 to 1.5 ±2.7. These patients had 7 ± 3.5 different VTs at the time of ablation. These data suggest not only a decrease the occurrence of VT, but an improved control of the arrhythmia as manifested by decreased frequency of episodes and a decrease in shock. This suggests a straightforward alternative to point source ablation or to the requirement of detailed LAVA intervention. Conclusion: Linear infarct edge homogenization is a straightforward means of ablating ventricular tachycardia’s, even when unstable. This approach may be simpler than seen with LAVA interventions.
Abstract 15764: Aortic Valve Intervention for Severe Aortic Stenosis Improves Outcomes Following Non-cardiac Surgery
Luis, Sushil Allen , Pislaru, Sorin V. , Scott, Christopher G. , Kane, Garvan C. , Abel, Martin , Nkomo, Vuyisile T. , Pellikka, Patricia A.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.15764 Get It

Background: Non-cardiac surgery (NCS) in patients with severe aortic stenosis has traditionally been associated with high perioperative mortality. Aortic valve replacement is recommended prior to elective NCS, but the impact of this strategy has not been systematically assessed. Methods: A retrospective review was performed of all patients with severe aortic stenosis undergoing major NCS at Mayo Clinic between 2000 and 2013. Patients undergoing aortic valve intervention (AVI) prior to NCS were compared to those undergoing surgery without prior AVI (control). Patients undergoing emergency surgery were excluded. Primary endpoint was occurrence of major adverse cardiac events (MACE; combination of death, stroke, myocardial infarction, new/worsening heart failure, ventricular arrhythmia) within 30 days of NCS; secondary endpoints were mortality at 30 days and 1 year after NCS. Results: 180 patients (age 74.5 ± 10.5 years, 64% male) who underwent NCS within 12 months after AVI, were compared to 232 patients (age 76.6 ± 10.7 years, 56% male) in the control group. Patients undergoing AVI were more often symptomatic than controls (41% vs 26%, p = 0.002). MACE was significantly higher in the control group (21.6% vs 5.6%, p < 0.001), mainly due to the increased risk of heart failure in the postoperative period in this group (18.5% vs 2.2%, p < 0.001). There was no significant difference in the rate of myocardial infarction (1.7% vs 0.6%, p = 0.39), ventricular arrhythmia (0.9 % vs 0 %, p = 0.51) or stroke (0.9 % vs 0 %, p = 0.51). Kaplan-Meier assessment demonstrated no significant difference at 30 days but a reduction in 1 year mortality in the AVI group compared to the control group (Figure). Conclusions: Pre-operative AVI for severe aortic stenosis results in reduced heart failure and improved 1 year survival. However, other MACE and 30 day mortality appears unchanged. Pre-operative AVI should be considered in symptomatic patients, where the benefit of AVI is demonstrated to be greatest.
Abstract 14709: Right Sternal Lead Placement Increases Eligibility for Subcutaneous Defibrillator Implantation in Adults With Congenital Heart Disease
Okamura, Hideo , Bashir, Mohammad U, Webster, Tracy L., Bonnichsen, Crystal R. , Grogan, Martha , Phillips, Sabrina D. , Warnes, Carole A. , Ammash, Naser M., Connolly, Heidi M. , Friedman, Paul A. , McLeod, Christopher J.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14709 Get It

Introduction: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an attractive option for patients with congenital heart disease (CHD) in whom a transvenous system is contraindicated. However, more than 10% of adult patients with CHD fail S-ICD screening due to a large T- to R-wave ratio. We hypothesized right-sternal electrodes may permit S-ICD placement in patients who fail left-sternal screen. Methods: We prospectively screened 40 patients with CHD for S-ICD using the standard proprietary approach. We also screened with right sternal electrodes (with left can electrode position). Results: The mean age of the cohort was 46+/-15 years; 24 males were enrolled. CHD anomalies consisted of tetralogy of Fallot (n=11), Ebstein’s anomaly (n=7), atrial septal defect (n=6), dextro-looped transposition of the great artery (n=5) and other (n=11). Left side screening ECG failed in 9 patients (23%), five of whom passed with right sternal electrodes, increasing the pass rate from 77% to 90%. Figure shows the screening ECG and chest x-ray of a patient who failed in all three vectors on the left side but passed in the alternative vector on the right side and underwent right sided implantation. Conclusions: The addition of right sternal electrodes during screening increases S-ICD eligibility and may avoid thoracotomy for high risk patients with CHD.
Abstract 13796: Safety of Subcutaneous Cenderitide Co-Therapy With LVAD Support: A Phase I, Placebo Controlled Cross-Over Study for Heart Failure
Schirger, John A., Koenig, LuAnne J., Wanek, Jacqueline R., Heublien, Denise M., Joyce, Lyle D., Chen, Horng H. , Burnett, Johh C, Ichiki, Tomoko , Scott, Christopher G.

Mayo Clinic

Circulation | April 23, 2024 | Volume: 134 | Issue: suppl_1 | Pages: No page available

10.1161/circ.134.suppl_1.13796 Get It

Introduction: While left ventricular assist devise (LVAD) support improves the prognosis of end-stage heart failure (HF) patients, the long-term outcomes remains suboptimal. Improved outcomes may occur with organ protection including reverse myocardial remodeling. Cenderitide (CDNP) is a Mayo engineered designer natriuretic peptide (NP) that co-activates particulate guanylyl cyclase A and B receptors and functions via the second messenger cGMP. We reported a NP deficient state in the heart with LVAD support which lays the rationale for NP replacement therapy with Cenderitide which has cardiorenal protective actions in experimental HF. We sought to determine if Cenderitide co-therapy would be safe and activate cGMP in patients with LVAD support. Hypothesis: Acute single dose of subcutaneous (SQ) Cenderitide will be safe and activate cGMP in patients with LVAD support. Methods: Stable HF patients with LVAD support (Heartmate II, all males) were enrolled in a cross-over design comparing SQ placebo and low (Low-C, 5 ug/kg, n=8) or high dose (High-C, 10 ug/kg, n=8) Cenderitide (Capricor Therapeutics) administration. Vital signs, plasma C(D)NP, cGMP, Aldosterone (Aldo), and NT-proBNP levels were measured before or after drug administration over 24 hours. All parameters in Cenderitide group were adjusted by those in placebo. Results: Both Low-C and High-C group demonstrated significantly increased plasma C(D)NP and cGMP levels for 2 hours after drug injection and those in High-C group showed more prolonged and higher increases than Low-C group. Mean arterial pressure (MAP) in Low-C did not show any changes but in High-C group tended to be lower for 18 hours but this was not significant. Plasma Aldo and NT-proBNP levels in Low-C group did not show any change but those in High-C group tended to be lower after drug injection s similar to the change in MAP. No adverse events were observed in the study. Conclusions: SQ Cenderitide was successfully absorbed, activated cGMP and well tolerated in patients with LVAD support. High dose Cenderitide may have cardiac unloading effects suggested by decreases in NT-proBNP. Further clinical trial for efficacy is warranted to clarify cardiorenal protective effects of Cenderitide in the LVAD population to improve outcomes.
Abstract 11366: Retained Cardiac Implantable Electronic Device Fragments After Incomplete Extraction Do Not Adversely Affect Magnetic Resonance Imaging Quality or Safety
Austin, Christopher , Landolfo, Kevin , Parikh, Pragnesh , Kusumoto, Fred

Mayo Clinic

Circulation | April 23, 2024 | Volume: 134 | Issue: suppl_1 | Pages: No page available

10.1161/circ.134.suppl_1.11366 Get It

Introduction: The prevalence of cardiac implantable electronic devices (CIED) is steadily increasing. Accordingly, the frequency of CIED extraction has also increased. Occasionally, safe retrieval of all CIED components is not feasabile and lead fragments are left behind. Little is known about the safety and diagnostic accuracy of MRI in patients with retained CIED fragments. Methods: Two hundred consecutive patients were identified as having undergone orthotopic heart transplantation (OHT) at our institution between April 2006 and December 2014. Chest x-rays immediately prior to OHT were reviewed for presence of CIED and chest x-rays immediately following OHT were reviewed for retained CIED fragments. MRI performed after OHT in patients with retained CIED fragments were inspected for image quality and procedural safety. The most recent chest x-ray in patients with retained CIED fragments subjected to MRI was reviewed for change in fragment position. Results: One hundred seventy-eight of 200 patients (89%) had CIED prior to OHT. All patients with CIED had surgical device extraction at the time of OHT. Of these, 29 patients (12%) had retained CIED fragments after OHT, the majority of which (23/29) were ICD coil fragments located in the superior vena cava, brachiocephalic or subclavian vein. Ten patients with retained CIED fragments underwent a total of 28 MRI after OHT. No patient safety issues were identified during MRI acquisition, and all MRI images were of diagnostic quality. There were no changes in the position of CIED fragments following MRI. Conclusions: Diagnostic MRI can be safely performed in patients with retained CIED fragments after incomplete device extraction. Adherence of the ICD coil to the vessel wall due to fibrosis has been well described and is a common impediment to complete device extraction. Retrieval of these fragments prior to MRI does not appear warranted given the demonstrated safety and preserved MRI image quality in this population.
Improved Skeletal Dynamics in Adults Treated With Palopegteriparatide for Hypoparathyroidism: 52-Week Analysis of Phase 3 PaTHway Trial
Khan, Aliya , Rubin, Mishaela R. , Shoback, Dolores , Peter, Schwarz, Kohlmeier, Lynn, Eriksen, Erik Fink , Jain, Rajesh Kumar , Zhao, Carol, Lai, Bryant, Ukena, Jenny, Ominsky, Michael S. , Tsourdi, Elena , Palermo, Andrea , Clarke, B.L. , Cetani, Filomena , Zhao, Carol, Ukena, Jenny, Sibley, Christopher T. , Shu, Aimee D , Rejnmark, Lars

Mayo Clinic

Osteologie | April 23, 2024 | Volume: 33 | Issue: 02 | Pages: 113-113

10.1055/s-0044-1782054 Get It

International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Romańczyk, Monika , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, P. , Iyer, Prasad G. , Srinivasan, Sachin , Grover, Samir C , Kaminski, Michal Filip , Bisschops, Raf , Bugdol, Marcin Dominik , Gyawali, P., Inoue, H., Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Hassan, Cesare , Sharma, Prateek

Mayo Clinic

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S27-S28

10.1055/s-0044-1782743 Get It

Outpatient COVID-19 convalescent plasma recipient antibody thresholds correlated to reduced hospitalizations within a randomized trial
Park, Han-Sol , Yin, Anna , Barranta, Caelan, Caputo, Christopher , Sachithanandham, Jaiprasath , Li, Maggie , Yoon, Steve, Sitaras, Ioannis , Jedlicka, Anne , Eby, Yolanda , Ram, Malathi , Fernández, Reinaldo E. , Baker, Owen R. , Fukuta, Yuriko , Patel, Bela , Heath, Sonya L. , Spivak, Emily S , Huamán, Moisés A. , Blair, Janis E. , Gerber, Jonathan M. , Petrini, Joann, Broderick, Patrick , Rausch, William, Cordisco, Marie Elena , Hammel, Jean, Greenblatt, Benjamin, Cluzet, Valerie , Cruser, Daniel, Oei, Kevin , Abinante, Matthew, Hammitt, Laura L. , Forthal, Donald N. , Cachay, Edward R. , Marshall, Christi E., Lane, Karen , McBee, Nichol , Gawad, Amy L., Karlen, Nicky, Singh, Atika, Jabs, Douglas A. , Shade, David , Lau, Bryan , Ehrhardt, Stephan , Baksh, Sheriza , Ou, Jiangda , Na, Yu Bin , Knoll, Maria Deloria , Ornelas-Gatdula, Elysse, Gniadek, Thomas J. , Wu, Jinke, Ndahiro, Nelson , Betenbaugh, Michael J. , Ziman, Alyssa , Bloch, Evan M. , Laeyendecker, Oliver , Ziman, Alyssa , Huaman, Moises A , Laeyendecker, Oliver , Lee, John S. , Shenoy, Aarthi , Mosnaim, Giselle S , Levine, Adam C , Meisenberg, Barry R. , Anjan, Shweta , Currier, Judith S. , Paxton, James H , Sutcliffe, Catherine G , Zand, Martin S. , Raval, Jay S. , Kassaye, Seble , Yarava, Anusha , Ford, Daniel E , Appel, Lawrence J. , Shapiro, Janna R. , Arroyo‐Currás, Netzahualcóyotl , Caturegli, Patrizio , Hanley, Daniel F. , Casadevall, Arturo , Shoham, Shmuel , Gebo, Kelly A , Tobian, Aaron A.R. , Pekosz, Andrew , Klein, Sabra L , Sullivan, David

Mayo Clinic

JCI Insight | April 23, 2024 | Volume: 9 | Issue: 8 | Pages: No page available

10.1172/jci.insight.178460 | PMID 38483534 Get It

BACKGROUND COVID-19 convalescent plasma (CCP) virus-specific antibody levels that translate into recipient posttransfusion antibody levels sufficient to prevent disease progression are not defined. METHODS This secondary analysis correlated donor and recipient antibody levels to hospitalization risk among unvaccinated, seronegative CCP recipients within the outpatient, double-blind, randomized clinical trial that compared CCP to control plasma. The majority of COVID-19 CCP arm hospitalizations (15/17, 88%) occurred in this unvaccinated, seronegative subgroup. A functional cutoff to delineate recipient high versus low posttransfusion antibody levels was established by 2 methods: (i) analyzing virus neutralization–equivalent anti–Spike receptor-binding domain immunoglobulin G (anti-S-RBD IgG) responses in donors or (ii) receiver operating characteristic (ROC) curve analysis. RESULTS SARS-CoV-2 anti–S-RBD IgG antibody was volume diluted 21.3-fold into posttransfusion seronegative recipients from matched donor units. Virus-specific antibody delivered was approximately 1.2 mg. The high-antibody recipients transfused early (symptom onset within 5 days) had no hospitalizations. A CCP-recipient analysis for antibody thresholds correlated to reduced hospitalizations found a statistical significant association between early transfusion and high antibodies versus all other CCP recipients (or control plasma), with antibody cutoffs established by both methods-donor-based virus neutralization cutoffs in posttransfusion recipients (0/85 [0%] versus 15/276 [5.6%]; P = 0.03) or ROC-based cutoff (0/94 [0%] versus 15/267 [5.4%]; P = 0.01). CONCLUSION In unvaccinated, seronegative CCP recipients, early transfusion of plasma units in the upper 30% of study donors’ antibody levels reduced outpatient hospitalizations. High antibody level plasma units, given early, should be reserved for therapeutic use. TRIAL REGISTRATION ClinicalTrials.gov NCT04373460. FUNDING Department of Defense (W911QY2090012); Defense Health Agency; Bloomberg Philanthropies; the State of Maryland; NIH (3R01AI152078-01S1, U24TR001609-S3, 1K23HL151826NIH); the Mental Wellness Foundation; the Moriah Fund; Octapharma; the Healthnetwork Foundation; the Shear Family Foundation; the NorthShore Research Institute; and the Rice Foundation.