Back to Authors

Caturegli, Patrizio

0000-0001-6768-6308

A5011334545 | I145311948

Mayo Clinic

Johns Hopkins University

Citations 6

COVID-19 convalescent plasma safety and efficacy analysis for biologics license application approval

Expert Review of Anti-infective Therapy | January 28, 2026 | Volume: 24 | Issue: 1 | Pages: 97-111

10.1080/14787210.2026.2623136 | PMID 41592860

Reply to Letter: Real‐World Clinical Experience With Serum MOG and AQP4 Antibody Testing by Live Versus Fixed Cell‐Based Assay

Annals of Clinical and Translational Neurology | May 14, 2025 | Volume: 12 | Issue: 8 | Pages: 1725-1726

10.1002/acn3.70061 | PMID 40368601

Real‐world clinical experience with serum MOG and AQP4 antibody testing by live versus fixed cell‐based assay

Annals of Clinical and Translational Neurology | February 4, 2025 | Volume: 12 | Issue: 3 | Pages: 556-564

10.1002/acn3.52310 | PMID 39901660

Abstract Objective To assess the real‐world performance of a live (LCBA) versus a fixed (FCBA) cell‐based assay for the detection of serum antibodies directed against myelin oligodendrocyte glycoprotein (MOG‐IgG) and aquaporin‐4 (AQP4‐IgG). Methods This was a retrospective study of patients evaluated at a single tertiary academic referral center, with serum testing performed clinically for AQP4‐IgG and/or MOG‐IgG by FCBA and LCBA on the same day. Additionally, frozen banked sera from the same day for patients tested only by one assay were retrieved and tested by the other assay. FCBA was performed by the Johns Hopkins Immunology Laboratory using Euroimmun kits with detection by indirect immunofluorescence (FCBA‐IF), whereas LCBA was performed by the Mayo Clinic Neuroimmunology Laboratory with detection by flow cytometry (LCBA‐FACS). Results Of 594 specimens with paired MOG‐IgG testing, 500 were negative by both assays, 33 were positive by both assays, 56 were positive exclusively by LCBA‐FACS, and 5 were only positive by FCBA‐IF. Overall, MOG‐IgG LCBA‐FACS exhibited 95.1% sensitivity and 97.7% specificity, whereas MOG‐IgG FCBA‐IF had 45.7% sensitivity and 99.8% specificity. Of 577 specimens with paired AQP4‐IgG testing, 503 were negative by both assays, 51 were positive by both assays, 21 were positive exclusively by LCBA‐FACS, and 2 were only positive by FCBA‐IF. Overall, AQP4‐IgG LCBA‐FACS exhibited 97.3% sensitivity and 100% specificity, whereas AQP4‐IgG FCBA‐IF had 71.6% sensitivity and 100% specificity. Interpretation LCBA‐FACS for both MOG‐IgG and AQP4‐IgG had markedly better sensitivity than FCBA‐IF, with similar specificity. The use of FCBA‐IF may result in underrecognition of both MOG antibody‐associated disease (MOGAD) and AQP4‐IgG seropositive neuromyelitis optica spectrum disorder (NMOSD).
Outpatient COVID-19 convalescent plasma recipient antibody thresholds correlated to reduced hospitalizations within a randomized trial

JCI Insight | April 23, 2024 | Volume: 9 | Issue: 8 | Pages: No page available

10.1172/jci.insight.178460 | PMID 38483534

BACKGROUND COVID-19 convalescent plasma (CCP) virus-specific antibody levels that translate into recipient posttransfusion antibody levels sufficient to prevent disease progression are not defined. METHODS This secondary analysis correlated donor and recipient antibody levels to hospitalization risk among unvaccinated, seronegative CCP recipients within the outpatient, double-blind, randomized clinical trial that compared CCP to control plasma. The majority of COVID-19 CCP arm hospitalizations (15/17, 88%) occurred in this unvaccinated, seronegative subgroup. A functional cutoff to delineate recipient high versus low posttransfusion antibody levels was established by 2 methods: (i) analyzing virus neutralization–equivalent anti–Spike receptor-binding domain immunoglobulin G (anti-S-RBD IgG) responses in donors or (ii) receiver operating characteristic (ROC) curve analysis. RESULTS SARS-CoV-2 anti–S-RBD IgG antibody was volume diluted 21.3-fold into posttransfusion seronegative recipients from matched donor units. Virus-specific antibody delivered was approximately 1.2 mg. The high-antibody recipients transfused early (symptom onset within 5 days) had no hospitalizations. A CCP-recipient analysis for antibody thresholds correlated to reduced hospitalizations found a statistical significant association between early transfusion and high antibodies versus all other CCP recipients (or control plasma), with antibody cutoffs established by both methods-donor-based virus neutralization cutoffs in posttransfusion recipients (0/85 [0%] versus 15/276 [5.6%]; P = 0.03) or ROC-based cutoff (0/94 [0%] versus 15/267 [5.4%]; P = 0.01). CONCLUSION In unvaccinated, seronegative CCP recipients, early transfusion of plasma units in the upper 30% of study donors’ antibody levels reduced outpatient hospitalizations. High antibody level plasma units, given early, should be reserved for therapeutic use. TRIAL REGISTRATION ClinicalTrials.gov NCT04373460. FUNDING Department of Defense (W911QY2090012); Defense Health Agency; Bloomberg Philanthropies; the State of Maryland; NIH (3R01AI152078-01S1, U24TR001609-S3, 1K23HL151826NIH); the Mental Wellness Foundation; the Moriah Fund; Octapharma; the Healthnetwork Foundation; the Shear Family Foundation; the NorthShore Research Institute; and the Rice Foundation.
Convalescent plasma with a high level of virus-specific antibody effectively neutralizes SARS-CoV-2 variants of concern

Blood Advances | April 20, 2022 | Volume: 6 | Issue: 12 | Pages: 3678-3683

10.1182/bloodadvances.2022007410 | PMID 35443020

Abstract The ongoing evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants severely limits available effective monoclonal antibody therapies. Effective drugs are also supply limited. COVID-19 convalescent plasma (CCP) qualified for high antibody levels effectively reduces immunocompetent outpatient hospitalization. The Food and Drug Administration currently allows outpatient CCP for the immunosuppressed. Viral-specific antibody levels in CCP can range 10- to 100-fold between donors, unlike the uniform viral-specific monoclonal antibody dosing. Limited data are available on the efficacy of polyclonal CCP to neutralize variants. We examined 108 pre-δ/pre-ο donor units obtained before March 2021, 20 post-δ COVID-19/postvaccination units, and 1 pre-δ/pre-ο hyperimmunoglobulin preparation for variant-specific virus (vaccine-related isolate [WA-1], δ, and ο) neutralization correlated to Euroimmun S1 immunoglobulin G antibody levels. We observed a two- to fourfold and 20- to 40-fold drop in virus neutralization from SARS-CoV-2 WA-1 to δ or ο, respectively. CCP antibody levels in the upper 10% of the 108 donations as well as 100% of the post-δ COVID-19/postvaccination units and the hyperimmunoglobulin effectively neutralized all 3 variants. High-titer CCP neutralizes SARS-CoV-2 variants despite no previous donor exposure to the variants.
American Thyroid Association Guidelines on the Management of Thyroid Nodules and Differentiated Thyroid Cancer Task Force Review and Recommendation on the Proposed Renaming of Encapsulated Follicular Variant Papillary Thyroid Carcinoma Without Invasion to

Thyroid | January 23, 2017 | Volume: 27 | Issue: 4 | Pages: 481-483

10.1089/thy.2016.0628 | PMID 28114862