Citations

Showing 10 of 107964 citations.

Plasma Quantitative Microbial Cell-Free DNA for Staphylococcal Cardiac Implantable Electronic Device Infection—Too Soon?
Chesdachai, Supavit , Ranganath, Nischal , Saleh, Omar Abu , Ranganath, Nischal , Abu Saleh, Omar M, Chesdachai, Supavit , DeSimone, Daniel C.

Mayo Clinic

Clinical Infectious Diseases | April 12, 2025 | Volume: 81 | Issue: 4 | Pages: e235-e236

10.1093/cid/ciaf195 | PMID 40231409 Get It

Prolonged Adrenal Insufficiency After Failed Cryoablation and Osilodrostat for Cushing Syndrome in Nodular Adrenal Disease
Veloski, Colleen, Sturgeon, Amanda, Hallanger‐Johnson, Julie

Mayo Clinic

JCEM Case Reports | April 12, 2025 | Volume: 3 | Issue: 6 | Pages: No page available

10.1210/jcemcr/luaf091 | PMID 40303510 Get It

Abstract Nodular adrenocortical disease is an entity more commonly recognized in recent years. We present a case of bilateral adrenal nodular disease in a young woman with ACTH-independent Cushing syndrome. She was treated with medical therapies at her preference to avoid adrenal insufficiency (AI) from surgery. She developed intolerance to medical therapy. Cryoablation of the right adrenal nodule was performed after adrenal vein sampling identified the right adrenal as the dominant source of cortisol. Cortisol levels were normal while on medical therapy after cryoablation but quickly became elevated after discontinuing medical therapy. The patient was then treated with osilodrostat and ultimately developed medication-induced AI that has persisted for more than 3 years. Due to the increased availability of new medications to treat Cushing syndrome, we present our experience to educate endocrinology audiences about the unexpected responses to medications. Using osilodrostat (off-label) in this patient led to prolonged primary AI after 4 months of use and now presumed permanent AI 36 months after discontinuation of treatment.
Evaluation of an Automated Workstation for Aliquoting Whole Blood from Primary Sample Tubes
Zuckerman, Eric Zimmerman , Dukek, Brian A. , Hunsberger, Dee, Scheitz, Eric, Ward, A. H., Erickson, Steven, Hartman, Tom, Yiglletu, Martha, Baumann, N, Jannetto, Paul J. , Zimmerman Zuckerman, Eric , Dukek, Brian, Faber, Jennifer , Ward, Amanda, Baumann, Nikola, Jannetto, Paul, Faber, Jennifer, Ward, Amanda, Erickson, Steven, Hartman, Tom

Mayo Clinic

The Journal of Applied Laboratory Medicine | April 12, 2025 | Volume: 10 | Issue: 4 | Pages: 924-936

10.1093/jalm/jfaf035 | PMID 40219827 Get It

Abstract Background We evaluated the Tecan Fluent Mix and Pierce Workstation as an automated platform to aliquot directly from whole blood collection tubes. The Fluent Mix and Pierce Workstation uses the Tube Rotator™, an on-deck rotisserie, to keep whole blood in suspension, and 8 Piercing Tips™ to cross the pierceable caps of collection tubes to aliquot samples. Methods We performed accuracy and precision testing by aliquoting residual whole blood specimens into an on-deck gravimetric scale. To test carryover, we aliquoted alternating blanks and high calibrators for several analytes and performed mass spectrometry on the blanks. We performed 168 runs over a 21-day period to test the robustness of the platform. We aliquoted and analyzed 2 batches of samples on both our clinical platform and the Mix and Pierce Workstation to check concordance. Results We observed that the Fluent Mix and Pierce Workstation can aliquot 200 µL with 0.5% inaccuracy and 0.9%CV and can aliquot 300 µL with 0.1% inaccuracy and 0.7%CV. We were unable to detect any analyte carryover using mass spectrometry. We observed no hardware failures during the instrument stress test. Clinical comparison runs indicated that the performance of aliquots made on the Fluent Mix and Pierce Workstation was equivalent to that of aliquots made by our current clinical method. Conclusions Overall, our evaluation showed that the Tecan Fluent Mix and Pierce Workstation is a viable platform for aliquoting whole blood for downstream work flows and can eliminate labor-intensive sample decapping and recapping in high-throughput settings.
Advances in computer vision and deep learning-facilitated early detection of melanoma
Liu, Yantong , Li, Chuang , Li, Feifei , Lin, Rubin, Zhang, Dongdong , Lian, Yifan , Lin, Rubin

Mayo Clinic

Briefings in Functional Genomics | April 12, 2025 | Volume: 24 | Issue: No issue available | Pages: No page available

10.1093/bfgp/elaf002 | PMID 40139223 Get It

Abstract Melanoma is characterized by its rapid progression and high mortality rates, making early and accurate detection essential for improving patient outcomes. This paper presents a comprehensive review of significant advancements in early melanoma detection, with a focus on integrating computer vision and deep learning techniques. This study investigates cutting-edge neural networks such as YOLO, GAN, Mask R-CNN, ResNet, and DenseNet to explore their application in enhancing early melanoma detection and diagnosis. These models were critically evaluated for their capacity to enhance dermatological imaging and diagnostic accuracy, crucial for effective melanoma treatment. Our research demonstrates that these AI technologies refine image analysis and feature extraction, and enhance processing capabilities in various clinical settings. Additionally, we emphasize the importance of comprehensive dermatological datasets such as PH2, ISIC, DERMQUEST, and MED-NODE, which are crucial for training and validating these sophisticated models. Integrating these datasets ensures that the AI systems are robust, versatile, and perform well under diverse conditions. The results of this study suggest that the integration of AI into melanoma detection marks a significant advancement in the field of medical diagnostics and is expected to have the potential to improve patient outcomes through more accurate and earlier detection methods. Future research should focus on enhancing these technologies further, integrating multimodal data, and improving AI decision interpretability to facilitate clinical adoption, thus transforming melanoma diagnostics into a more precise, personalized, and preventive healthcare service.
Distal Medial Collateral Ligament Avulsion Repair
Rechter, Griffin R. , Barrera, Lindsay , Daniel, Adam V. , Hevesi, Mario, Krych, Aaron J. , Tagliero, Adam J. , Levy, Bruce A. , Tagliero, Adam , Krych, Aaron J , Hevesi, Mario

Mayo Clinic

Arthroscopy Techniques | April 12, 2025 | Volume: 14 | Issue: 6 | Pages: No page available

10.1016/j.eats.2025.103525 | PMID 40656730 Get It

Abstract The ability of the knee to resist valgus stress is largely a result of the integrity of the superficial medial collateral ligament (MCL) and neighboring supporting structures (i.e., deep MCL, semimembranosus, and posterior oblique ligament). The MCL is known to have a robust healing capacity; consequently, the decision to proceed with operative versus nonoperative management of even grade III MCL tears is controversial. When it comes to operative management of these injuries, the decision to proceed with repair or reconstruction is nuanced because the chronicity and location of the MCL tear (i.e., proximal, midsubstance, or distal) largely determine which technique is appropriate. In distal MCL avulsions, including the so‐called Stener lesion, with good tissue quality, direct MCL repair has shown excellent mid‐term outcomes. Consequently, there is a growing need to understand different techniques to address MCL incompetence. In this article, we present a method for primary MCL repair using a washer post–suture post construct. Technique Video video See video under supplementary data.
SAHVAI‐3D and 4D: Automated AI Volumetric Measurement of Subarachnoid Hemorrhage on Noncontrast Head CT
Wirtz, Melina, Salman, Saif , Wei, Yujia , Patel, Vishal , Sharma, Rohan , Gupta, Vikash , Gu, Qiangqiang , Dherin, Benoît , Reddy, Sanjana , Patel, Vishal N, Freeman, William D , Tawk, Rabih G. , Erickson, Bradley J. , Freeman, William D.

Mayo Clinic

Stroke: Vascular and Interventional Neurology | April 12, 2025 | Volume: 5 | Issue: 3 | Pages: No page available

10.1161/svin.124.001620 | PMID 41573412 Get It

Background We automated subarachnoid hemorrhage volume (SAHV) calculation with artificial intelligence (SAHVAI) and created 3‐dimensional volumetric images (SAHVAI‐3D) using noncontrast head computed tomography data for patients with aneurysmal SAH. We also defined 4‐dimensional SAHVAI (SAHVAI‐4D), representing SAHV over time. We aimed to compare automated SAHVAI values and computational times to manual SAHV measurement methods, explore the potential of imaging biomarkers to identify at‐risk brain regions for delayed cerebral ischemia and explore potential insights in future neurotherapeutic interventions for patient recovery after SAH. Methods A training set of 10 consecutive patients with aneurysmal SAH was used to manually compute SAHV, SAHVAI‐3D, and SAHVAI‐4D, including 92 noncontrast computed tomography scans (182 slices each). The SAHVAI deep learning algorithm generated automated SAHV values in cubic centimeters. A 3‐dimensional SAH brain map was created for each patient for the SAHVAI and manual evaluations. Blood volumetric outputs were analyzed and compared to neurologic outcomes at discharge, including delayed cerebral ischemia events, symptomatic vasospasm, and areas with the thickest SAH blood concentration. Results SAHVAI quantified SAHV in a mean of 6.7 seconds per scan, significantly faster than the manual method, which took >60 minutes per scan (Fisher exact test, P <0.001). SAHVAI demonstrated an accuracy of 99.8%, Dice score of 0.701, false‐positive rate of 0.0005, and negative predictive value of 0.999. The mean absolute error between SAHVAI and manual methods was 5.67 mL. SAHVAI‐3D brain map and total SAHV at admission were inversely associated with Glasgow Coma Scale (R 2 = 0.23, P = 0.017) and directly associated with length of hospital stay (R 2 = 0.175, P = 0.004), especially in regions with dense blood concentration. Conclusion SAHVAI‐3D and SAHVAI‐4D brain mapping techniques represent innovative imaging biomarkers for SAH. These advancements enable rapid evaluation and targeted interventions, potentially improving patient care in SAH management.
An interactive care plan plus remote blood pressure monitoring in a rural primary care clinic: a pilot study
DeJesus, Ramona S. , Njeru, Jane W. , Beahm, Mark R., Gullerud, Rachel E., Grimm, Jessica A. , Copeland, Barbara J., Lunde, Julianne J. , Croghan, Ivana T.

Mayo Clinic

Blood Pressure | April 12, 2025 | Volume: 34 | Issue: 1 | Pages: No page available

10.1080/08037051.2025.2490589 | PMID 40219656 Get It

Bilateral External Ear Canal Duplication: A Case Report
Ebbert, Landon E. , Crockett, David J. , Page, Nathan , Ebbert, Joshua , Amoo-Quaye, Grace, Hanson, Nana Andoh Mensah, Appiah–Thompson, Peter , Crockett, David, Page, Nathan C , Crockett, David

Mayo Clinic

Ear, Nose & Throat Journal | April 12, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/01455613251333233 | PMID 40219830 Get It

Herein described is an eight-year-old female patient presenting with bilateral external ear canal duplication and a history of recurrent postauricular abscesses, otorrhea, and moderate left-sided conductive hearing loss. Previous incision and drainage of the postauricular abscesses yielded little long-term success. Medical history was otherwise unremarkable. Physical examination revealed a cystic mass in the right ear and postauricular fibrosis, likely a result of previous surgical interventions. An audiogram revealed asymmetric hearing function, with mild-to-moderate conductive hearing loss in the left ear contrasting normal hearing in the right ear, while tympanometry confirmed an intact right tympanic membrane but was precluded on the left due to purulent otorrhea. A head CT scan revealed postauricular soft tissue swelling and well-pneumatized mastoid air cells. Both ears were explored intraoperatively via postauricular incisions. Surgical excision included removal of a cyst, cartilaginous remnants, and fibrotic tissue. The patient was followed up to assess for postsurgical complications. The surgical site healed uneventfully; no new symptoms or recurrences of past symptoms of otorrhea, cyst formation, or abscesses had developed within the twelve weeks post-surgery. Although external ear canal duplications are rare, it is imperative that early, accurate diagnoses be made to ensure optimal patient outcomes.
The terrible triad of the shoulder: injury characteristics and outcomes of axillary nerve reconstruction
Wilson, Charlie D. , Welling, Benjamin D, Spinner, Robert J. , Shin, Alexander Y. , Shin, Alexander Y , Bishop, Allen T.

Mayo Clinic

Journal of Hand Surgery (European Volume) | April 12, 2025 | Volume: 50 | Issue: 9 | Pages: 1185-1193

10.1177/17531934251333250 | PMID 40219809 Get It

We aimed to describe outcomes, including shoulder motion, deltoid strength and Disabilities of Arm, Shoulder and Hand scores, in 19 patients with terrible triad shoulder injuries (anterior shoulder dislocation, rotator cuff tear or greater tuberosity fracture, and axillary nerve injury) who required axillary nerve reconstruction. The type of nerve surgery (grafting vs. nerve transfer), demographic factors and injury characteristics were not significantly associated with outcomes. The mean postoperative abduction and Disabilities of Arm, Shoulder and Hand score were 95° and 28, respectively. Patients with rotator cuff tears had a higher Disabilities of Arm, Shoulder and Hand score (more disability) than those with isolated greater tuberosity fractures. We conclude that spontaneous recovery of the axillary nerve may not occur in patients with a terrible triad injury. Functional outcomes after axillary nerve repair are poor with respect to motion, strength and patient-reported outcomes compared with reported results for axillary nerve reconstruction in the absence of rotator cuff injury. Level of evidence: IV
Safety and Efficacy of Genicular Artery Embolization for Knee Joint Osteoarthritis Associated Pain: A Systematic Review
Ashraf, Nader , Tahir, Muhammad Junaid , Arabi, Tarek Ziad , Shaar, Bader Abou , Osman, Nadine , Mashkoor, Yusra , Ouban, Abderrahman , Abou Shaar, Bader , Asghar, Muhammad Sohaib , Arabi, Tarek , Fawzy, Nader A , Sabbah, Belal Nedal , Khan, Faheemullah , Asad, Ali , Yousaf, Zohaib

Mayo Clinic

Journal of Endovascular Therapy | April 12, 2025 | Volume: 33 | Issue: 4 | Pages: 1642-1659

10.1177/15266028251326770 | PMID 40219609 Get It

Purpose: To systematically review the literature on the effectiveness, safety, and long-term outcomes of genicular artery embolization (GAE) for knee joint osteoarthritis (OA) associated pain. Materials and Methods: After registering the protocol with the PROSPERO database, a search was conducted from inception until July 31, 2023, in MEDLINE, Cochrane Central Register of Controlled Trials, and ScienceDirect databases to gather studies evaluating GAE’s safety and efficacy in knee OA. A total of 4979 studies were identified and evaluated against the inclusion criteria. Data on study characteristics, success parameters, and adverse events were collected and synthesized. Results: Twenty-three studies, primarily single-center prospective studies with a total of 657 patients, were included. Most studies reported a 100% technical success rates, except one study reporting a rate of 84.2%. Clinical success rates, defined variably across studies, ranged from 30% to 100%, depending on the study’s follow-up period and outcome measures. The most frequent adverse events included skin discoloration without an ulcer (15.6%, n = 98) and transient post-procedural knee pain (10.2%, n = 64). Most studies were rated as fair in terms of quality, but the lack of robust randomized controlled trials highlighted the need for further comparative studies to standardize outcome reporting. Conclusion: GAE appears to be a promising option for knee OA pain, particularly for patients unresponsive to conservative treatments or ineligible for surgery. High-quality studies are needed to confirm long-term effectiveness and standardize outcome measures. Clinical Impact This study highlights the safety and efficacy of genicular artery embolization as a minimally invasive treatment for knee osteoarthritis, particularly in patients who are unresponsive to conservative treatments or unsuitable for surgery. By targeting neovascularization and reducing inflammation, genicular artery embolization provides pain relief and functional improvement. Clinicians can consider genicular artery embolization as an alternative to surgery for mild-to-moderate OA, offering a lower adverse event rate and faster recovery.