Citations

Clear

1577 citation(s) found for "Wu, Samuel".

High‐resolution electrical mapping of porcine gastric slow‐wave propagation from the mucosal surface
Angeli, Timothy R. , Du, Peng , Sathar, Shameer , Asirvatham, S, Farrugia, Gianrico , Windsor, John A. , Cheng, Leo K. , O’Grady, Gregory , Asirvatham, Samuel J. , Paskaranandavadivel, Niranchan , Hall, Andrew , Asirvatham, Samuel J , Angeli-Gordon, Timothy R

Mayo Clinic

Neurogastroenterology & Motility | December 30, 2016 | Volume: 29 | Issue: 5 | Pages: No page available

10.1111/nmo.13010 | PMID 28035728 Get It

AbstractBackgroundGastric motility is coordinated by bioelectrical slow waves, and gastric dysrhythmias are reported in motility disorders. High‐resolution (HR) mapping has advanced the accurate assessment of gastric dysrhythmias, offering promise as a diagnostic technique. However, HR mapping has been restricted to invasive surgical serosal access. This study investigates the feasibility of HR mapping from the gastric mucosal surface.MethodsExperiments were conducted in vivo in 14 weaner pigs. Reference serosal recordings were performed with flexible‐printed‐circuit (FPC) arrays (128‐192 electrodes). Mucosal recordings were performed by two methods: (i) FPC array aligned directly opposite the serosal array, and (ii) cardiac mapping catheter modified for gastric mucosal recordings. Slow‐wave propagation and morphology characteristics were quantified and compared between simultaneous serosal and mucosal recordings.Key ResultsSlow‐wave activity was consistently recorded from the mucosal surface from both electrode arrays. Mucosally recorded slow‐wave propagation was consistent with reference serosal activation pattern, frequency (P≥.3), and velocity (P≥.4). However, mucosally recorded slow‐wave morphology exhibited reduced amplitude (65‐72% reduced, P<.001) and wider downstroke width (18‐31% wider, P≤.02), compared to serosal data. Dysrhythmias were successfully mapped and classified from the mucosal surface, accorded with serosal data, and were consistent with known dysrhythmic mechanisms in the porcine model.Conclusions & InferencesHigh‐resolution gastric electrical mapping was achieved from the mucosal surface, and demonstrated consistent propagation characteristics with serosal data. However, mucosal signal morphology was attenuated, demonstrating necessity for optimized electrode designs and analytical algorithms. This study demonstrates feasibility of endoscopic HR mapping, providing a foundation for advancement of minimally invasive spatiotemporal gastric mapping as a clinical and scientific tool.
Evaluation of a Unique Defibrillation Unit with Dual‐Vector Biphasic Waveform Capabilities: Towards a Miniaturized Defibrillator
Okamura, Hideo , Killu, Ammar M. , Gilles, Emily J., Tri, Jason , Asirvatham, Roshini, LADEWIG, DEJAE J., Suddendorf, Scott H., Powers, Joanne, Wood‐Wentz, Christina M. , Gray, Peter D., RAYMOND, DOUGLAS M., SAVAGE, SHELLEY J., Savage, Walter T., Asirvatham, Samuel J. , Friedman, Paul A. , Powers, Joanne M, Wood-Wentz, Christina M, Bruce, Charles J. , DeSimone, Christopher V. , GRAY, PETER D., Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | December 19, 2016 | Volume: 40 | Issue: 2 | Pages: 108-114

10.1111/pace.12979 | PMID 27990645 Get It

BackgroundAutomated external defibrillators can provide life‐saving therapies to treat ventricular fibrillation. We developed a prototype unit that can deliver a unique shock waveform produced by four independent capacitors that is delivered through two shock vectors, with the rationale of providing more robust shock pathways during emergent defibrillation. We describe the initial testing and feasibility of this unique defibrillation unit, features of which may enable downsizing of current defibrillator devices.MethodsWe tested our defibrillation unit in four large animal models (two canine and two swine) under general anesthesia. Experimental defibrillation thresholds (DFT) were obtained by delivery of a unique waveform shock pulse via a dual‐vector pathway with four defibrillation pads (placed across the chest). DFTs were measured and compared with those of a commercially available biphasic defibrillator (Zoll M series, Zoll Medical, Chelmsford, MA, USA) tested in two different vectors. Shocks were delivered after 10 seconds of stable ventricular fibrillation and the output characteristics and shock outcome recorded. Each defibrillation series used a step‐down to failure protocol to define the defibrillation threshold.ResultsA total of 96 shocks were delivered during ventricular fibrillation in four large animals. In comparison to the Zoll M series, which delivered a single‐vector, biphasic shock, the energy required for successful defibrillation using the unique dual‐vector biphasic waveform did not differ significantly (P = 0.65).ConclusionsOur early findings support the feasibility of a unique external defibrillation unit using a dual‐vector biphasic waveform approach. This warrants further study to leverage this unique concept and work toward a miniaturized, portable shock delivery system.
Targeting integrin-linked kinase to suppress oncogenic KRAS signaling in pancreatic cancer
Kulp, Samuel K. , Bekaii‐Saab, Tanios , Chen, Ching-Shih, Chu, Po‐Chen , Bekaii-Saab, Tanios S

Mayo Clinic

Small GTPases | December 19, 2016 | Volume: 9 | Issue: 6 | Pages: 452-456

10.1080/21541248.2016.1251383 | PMID 27936345 Get It

Expecting the Expected
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | December 13, 2016 | Volume: 9 | Issue: 12 | Pages: No page available

10.1161/circep.116.004726 | PMID 27956435 Get It

Endocardial Device Leads in Patients with Patent Foramen Ovale: Echocardiographic Correlates of Stroke/TIA and Mortality
Ponamgi, Shiva , Vaidya, Vaibhav R. , Noheria, Amit , Hodge, David O. , Slusser, Joshua P. , Ammash, Naser M., Friedman, Paul A. , Asirvatham, Samuel J. , Ponamgi, Shiva P , Bruce, Charles J. , DeSimone, Christopher V. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | December 12, 2016 | Volume: 40 | Issue: 3 | Pages: 310-322

10.1111/pace.12985 | PMID 27943333 Get It

BackgroundEchocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO.MethodsIn 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow‐up echocardiogram.ResultsOf 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow‐up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time‐dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447–2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593–2.556, P < 0.0001), or maximum RVSP in follow‐up (HR 1.432, 95% CI 1.351–1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow‐up.ConclusionsIn patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.
Impact of Left Atrial Appendage Closure During Cardiac Surgery on the Occurrence of Early Postoperative Atrial Fibrillation, Stroke, and Mortality
Melduni, Rowlens M. , Lee, Hon-Chi, Bailey, Kent R. , Ammash, Naser M., Cha, Stephen S., Seward, James B., Packer, Douglas L. , Rihal, Charanjit S. , Asirvatham, Samuel J. , Fatema, Kaniz , Schaff, Hartzell V. , Gersh, Bernard J. , Noseworthy, Peter A. , Cha, Stephen S., Fatema, Kaniz , Wysokiński, Waldemar E. , Rihal, Charanjit S. , Asirvatham, Samuel J

Mayo Clinic

Circulation | December 1, 2016 | Volume: 135 | Issue: 4 | Pages: 366-378

10.1161/circulationaha.116.021952 | PMID 27903589 Get It

Background: Prophylactic exclusion of the left atrial appendage (LAA) is often performed during cardiac surgery ostensibly to reduce the risk of stroke. However, the clinical impact of LAA closure in humans remains inconclusive. Methods: Of 10 633 adults who underwent coronary artery bypass grafting and valve surgery between January 2000 and December 2005, 9792 patients with complete baseline characteristics, surgery procedure, and follow-up data were included in this analysis. A propensity score–matching analysis based on 28 pretreatment covariates was performed and 461 matching pairs were derived and analyzed to estimate the association of LAA closure with early postoperative atrial fibrillation (POAF) (atrial fibrillation ≤30 days of surgery), ischemic stroke, and mortality. Results: In the propensity-matched cohort, the overall incidence of POAF was 53.9%. In this group, the rate of early POAF among the patients who underwent LAA closure was 68.6% versus 31.9% for those who did not undergo the procedure ( P <0.001). LAA closure was independently associated with an increased risk of early POAF (adjusted odds ratio, 3.88; 95% confidence interval, 2.89–5.20), but did not significantly influence the risk of stroke (adjusted hazard ratio, 1.07; 95% confidence interval, 0.72–1.58) or mortality (adjusted hazard ratio, 0.92; 95% confidence interval, 0.75–1.13). Conclusions: After adjustment for treatment allocation bias, LAA closure during routine cardiac surgery was significantly associated with an increased risk of early POAF, but it did not influence the risk of stroke or mortality. It remains uncertain whether prophylactic exclusion of the LAA is warranted for stroke prevention during non–atrial fibrillation-related cardiac surgery.
His Bundle Refractoriness
Asirvatham, Samuel J. , Stevenson, William G. , Asirvatham, Samuel J

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | November 9, 2016 | Volume: 9 | Issue: 11 | Pages: No page available

10.1161/circep.116.004719 | PMID 27906656 Get It

Outcomes of atrial arrhythmia radiofrequency catheter ablation in patients with Ebstein’s anomaly
Hassan, Abdalla, Tan, Nicholas Y. , Aung, Htin , Connolly, Heidi M. , Hodge, David O. , Vargas, Emily , Cannon, Bryan C. , Packer, Douglas L. , Asirvatham, Samuel J. , Vargas, Emily R, McLeod, Christopher J. , Asirvatham, Samuel J

Mayo Clinic

EP Europace | November 7, 2016 | Volume: 20 | Issue: 3 | Pages: 535-540

10.1093/europace/euw396 | PMID 28340054 Get It

Alcohol Consumption and the Risk of Colorectal Cancer for Mismatch Repair Gene Mutation Carriers
Dashti, S. Ghazaleh , Buchanan, Daniel D. , Jayasekara, Harindra , Ouakrim, Driss Ait , Rosty, Christophe , Winship, Ingrid , Parry, Susan, Haile, Robert W. , Gallinger, Steven , Thibodeau, Stephen N. , Lindor, Noralane M. , Jenkins, Mark A. , Win, Aung Ko , Clendenning, Mark , Macrae, Finlay , Giles, Graham G. , Casey, Graham , Marchand, Loı̈c Le , Newcomb, Polly A. , Potter, John D. , Baron, John A. , Hopper, John L. , Buchanan, Daniel D , Win, Aung K , Jenkins, Mark A , Haile, Robert W , Rosty, Christophe , Winship, Ingrid M , Jayasekara, Harindra

Mayo Clinic

Cancer Epidemiology, Biomarkers & Prevention | November 4, 2016 | Volume: 26 | Issue: 3 | Pages: 366-375

10.1158/1055-9965.epi-16-0496 | PMID 27811119 Get It

Abstract Background: People with germline mutation in one of the DNA mismatch repair (MMR) genes have increased colorectal cancer risk. For these high-risk people, study findings of the relationship between alcohol consumption and colorectal cancer risk have been inconclusive. Methods: 1,925 MMR gene mutations carriers recruited into the Colon Cancer Family Registry who had completed a questionnaire on lifestyle factors were included. Weighted Cox proportional hazard regression models were used to estimate hazard ratios (HR) and 95% confidence intervals (CI) for the association between alcohol consumption and colorectal cancer. Results: Colorectal cancer was diagnosed in 769 carriers (40%) at a mean (SD) age of 42.6 (10.3) years. Compared with abstention, ethanol consumption from any alcoholic beverage up to 14 g/day and &gt;28 g/day was associated with increased colorectal cancer risk (HR, 1.50; 95% CI, 1.09–2.07 and 1.69; 95% CI, 1.07–2.65, respectively; Ptrend = 0.05), and colon cancer risk (HR, 1.78; 95% CI, 1.27–2.49 and 1.94; 95% CI, 1.19–3.18, respectively; Ptrend = 0.02). However, there was no clear evidence for an association with rectal cancer risk. Also, there was no evidence for associations between consumption of individual alcoholic beverage types (beer, wine, spirits) and colorectal, colon, or rectal cancer risk. Conclusions: Our data suggest that alcohol consumption, particularly more than 28 g/day of ethanol (∼2 standard drinks of alcohol in the United States), is associated with increased colorectal cancer risk for MMR gene mutation carriers. Impact: Although these data suggested that alcohol consumption in MMR carriers was associated with increased colorectal cancer risk, there was no evidence of a dose-response, and not all types of alcohol consumption were associated with increased risk. Cancer Epidemiol Biomarkers Prev; 26(3); 366–75. ©2016 AACR.
Myeloid-Derived Suppressor Cell Subset Accumulation in Renal Cell Carcinoma Parenchyma Is Associated with Intratumoral Expression of IL1β, IL8, CXCL5, and Mip-1α
Najjar, Yana G. , Jia, Xuefei, Tannenbaum, Charles S., Haywood, Samuel , Cohen, Peter A. , Hamilton, Thomas A. , Díaz‐Montero, C. Marcela , Finke, James H., Cohen, Peter, Rayman, Patricia A. , Jia, Xuefei, Pavicic, Paul G. , Rini, Brian I. , Ko, Jennifer S.

Mayo Clinic

Clinical Cancer Research | November 1, 2016 | Volume: 23 | Issue: 9 | Pages: 2346-2355

10.1158/1078-0432.ccr-15-1823 | PMID 27799249 Get It

Abstract Purpose: Little is known about the association between myeloid-derived suppressor cell (MDSC) subsets and various chemokines in patients with renal cell carcinoma (RCC) or the factors that draw MDSC into tumor parenchyma. Experimental Design: We analyzed polymorphonuclear MDSC (PMN-MDSC), monocytic MDSC (M-MDSC), and immature MDSC (I-MDSC) from the parenchyma and peripheral blood of 48 patients with RCC, isolated at nephrectomy. We analyzed levels of IL1β, IL8, CXCL5, Mip-1α, MCP-1, and Rantes. Furthermore, we performed experiments in a Renca murine model to assess therapeutic synergy between CXCR2 and anti-PD1 and to elucidate the impact of IL1β blockade on MDSC. Results: Parenchymal PMN-MDSC have a positive correlation with IL1β, IL8, CXCL5, and Mip-1α, and I-MDSC correlate with IL8 and CXCL5. Furthermore, peripheral PMN-MDSC correlate with tumor grade. Given that PMN-MDSC express CXCR2 and parenchymal PMN-MDSC correlated with IL8 and CXCL5, we assessed the response of CXCR2 blockade with or without anti-PD1. Combination therapy reduced tumor weight and enhanced CD4+ and CD8+ T-cell infiltration. In addition, anti-IL1β decreased PMN-MDSC and M-MDSC in the periphery, PMN-MDSC in the tumor, and peripheral CXCL5 and KC. Anti-IL1β also delayed tumor growth. Conclusions: Parenchymal PMN-MDSC have a positive correlation with IL1β, IL8, CXCL5, and Mip-1α, suggesting they may attract PMN-MDSC into the tumor. Peripheral PMN-MDSC correlate with tumor grade, suggesting prognostic significance. Anti-CXCR2 and anti-PD1 synergized to reduce tumor weight and enhanced CD4+ and CD8+ T-cell infiltration in a Renca murine model, suggesting that CXCR2+ PMN-MDSC are important in reducing activity of anti-PD1 antibody. Finally, anti-IL1β decreases MDSC and delayed tumor growth, suggesting a potential target for MDSC inhibition. Clin Cancer Res; 23(9); 2346–55. ©2016 AACR.