Citations

Clear

343 citation(s) found for "Asirvatham, Samuel J".

Activation Pattern During His-Bundle Pacing
Yasin, Omar , Bush, Jaime, Vaidya, Vaibhav R. , Tri, Jason , Zyl, Martin van , Xiao, Peilin , Scheuermann, Cory, Asirvatham, Samuel J. , Cha, Yong‐Mei , Asirvatham, Samuel J , Xiao, Peilin , Han, Jie

Mayo Clinic

No container title available | July 11, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162602806.64990926/v1 Get It

Abstract 60: Inducible Arrythmogenicity of Direct Current Electroporation Ablation: Insight from a Series of Acute Canine Studies
Sugrue, Alan , Witt, Chance M. , Padnanabhan, Deepak, Killu, Ammar M. , Naksuk, Niyada , DeSimone, Christopher V. , Kapa, Suraj , Asirvatham, Samuel J.

Mayo Clinic

Circulation Research | July 3, 2021 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.60 Get It

Background: The use of direct current electroporation has the potential for significant utility because of its non-thermal approach to tissue destruction. However, the fear of inducibility of cardiac arrhythmias (particular ventricular fibrillation) when using electroporation remains of concern due to membrane poration and ion flux during periods of vulnerability occurring in ventricular repolarization. Objectives: Critically examine the incidence of arrhythmias in a series of acute canine studies to retrospectively determine cause and safe electoporative dosing margins. Methods: We performed electroporation ablation in 6 acute canine studies. These were experimental studies performed at sites critical in arrhytmogenesis. Sites included the pulmonary veins, left atrial appendage, superior vena cavae, right atrium and ventricle. Electroporation was delivered using an ECG gating algorithm so that QRS complexes are tagged and direct current energy is not delivered during the vulnerable portion of the T wave. Results: In 6 acute canine experiments, we delivered a total of 62 electroporation applications for ablation purposes. The average electroporation dosage delivered involved an average of 1427 Volts (range 750-3000 V), Pulse length of 100 ms, and number of pulses of 20.2 (range 10-100). AF was induced in 27.4% of electroporiatve applications. Atrial flutter/tachycardia occurred in 8.1%. VF occurred in only one application at a location of the left superior pulmonary vein. Conclusion: These data suggest that induction of VF is relatively uncommon with ECG gating and highlight its importance when using this modality. However, the induction of AF occurs with higher frequency. The actual mechanism as to why this occurs requires further systematic study.
Abstract 20364: Successful Ablation of Ventricular Fibrillation in Malignant Bileaflet Mitral Valve Prolapse Syndrome
Syed, Faisal F. , Mulpuru, Siva K. , Sriram, Chenni S. , Cannon, Bryan C. , Ackerman, Michael J. , Noseworthy, Peter A. , McLeod, Christopher J. , Kapa, Suraj , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.20364 Get It

Introduction: Although the vast majority of mitral valve prolapse (MVP) is benign, women with bileaflet MVP (biMVP), complex ventricular ectopy (VE), and abnormal T waves may comprise the recently described malignant biMVP syndrome. The mechanism of ventricular arrhythmia is unknown. To further characterize the arrhythmic substrate, we reviewed our center’s ablation experience in 6 biMVP patients with prior cardiac arrest and recurrent ICD shocks for drug refractory ventricular fibrillation (VF). Methods and Results: Six women with biMVP (median age 31.5 [range 24.2 - 58.7] years, EF 65 [45 - 67]%, all ≤moderate mitral regurgitation) experienced 6 (3 - 25) appropriate ICD shocks over 4.8 (2.8 - 10.7) years and underwent index ablation between 2/2007 - 10/2013. All had multiple VE morphologies (median 7 [3 - 24]) with variable coupling intervals but with a predominant VE trigger for the VF. A median 2 (1 - 4) VE foci were ablated. Sites of successful ablation of VF-triggering and other dominant VE were left ventricular papillary muscles [PM] (1 anterior, 1 posterior, 1 both), fascicles (1 anterior, 1 posterior), or both (1 both PM and posterior fascicle). Outflow tract VE was also present and targeted (1 left, 1 right)i. Two underwent repeat ablation (288 and 312 days) for recurrent complex VE without shocks, with different foci to the index ablation (1 posterior fascicle, 1 both fascicles). The VF-triggering VE in all patients was confirmed as originating from within the left fascicular system, which in 3/6 was at a papillary muscle. Acute procedural success was seen in all with no complications to date. A VF storm occurred within 24 hours of ablation in a single patient. At follow-up of a mean 662 (47 - 2099) days, 1 patient received a single shock (p=0.03 vs. preablation). Symptomatic VE was reduced in all; while 3/6 continue Class 1c antiarrhythmics and 5/6 have beta blockade. Conclusion: Malignant biMVP syndrome is characterized by fascicular and papillary muscle PVCs that trigger ventricular fibrillation, yet in all patients, the VE is multifocal. Ablation of at least one focus appears to improve symptoms and reduce shocks.
Abstract 18318: Percutaneous Epicardial Access for Mapping and Ablation is Feasible in Patients With Prior Cardiac Surgery, Including Coronary Bypass Surgery
Killu, Ammar M. , Ebrille, Elisa , Munger, Thomas M. , Packer, Douglas L. , Friedman, Paul A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.18318 Get It

Introduction: Prior cardiac surgery, especially the presence of coronary bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, due to limited catheter maneuverability, mapping and ablation. The objective of our study was to evaluate the feasibility and safety of EpiAcc in patients with prior cardiac surgery. Methods: We retrospectively analyzed all patients who underwent EpiAcc as part of an ablation procedure between 01/01/2004-06/30/2013 at Mayo Clinic, Rochester, MN. All had documented VT or recurring, symptomatic PVCs. Baseline clinical characteristics and procedural characteristics were collected. Results: Of 162 patients that underwent EpiAcc, 18 had prior cardiac surgery (mean age 61 years, all male). This included 10 CABG, 2 epicardial ICD placement, 5 valve surgery (3 aortic valve, 2 mitral valve), 2 septal myectomy, 1 aortic arch replacement, 1 myocardial bridge unroofing and 1 myocardial perforation repair (3 patients had multiple procedures). Access was successful in 12 patients (66.7%); the inferior approach was utilized in 78%. Of patients with prior CABG, successful access was attained in 6 (60%). The average procedural time was 441.6 ± 141.3 minutes. Adhesiolysis was required in 10 patients with the sheath, access wire, pigtail catheter or ablation catheter. Intra-procedural coronary angiography was performed in 8 patients. There were a total of 45 VTs/PVCs ablated in 18 patients (average 2.5 ± 1.7), mean cycle length 463.6 ± 95.9ms. Ultimately, 12 patients (66.7%) underwent endocardial only ablation, 1 (5.5%) had epicardial only ablation while 5 (27.8%) had endocardial/epicardial ablation. The procedure was deemed successful in 13 patients (72.2%). Four patients had bleeding complications (pericardial effusion, pericardial hematoma, hemoperitoneum and pericardial tamponade [the latter required repair of the RV wall]). In patients with coronary grafts, there was no evidence of acute graft disruption. Conclusions: Percutaneous epicardial access is feasible in patients with previous cardiac surgery, including CABG. However, adhesiolysis is frequently required. Although the risk of coronary graft injury is low, life-threatening complications may occur.
Abstract 15331: Ventricular Conduction and Repolarization Prolongation Noted During Right Ventricular Pacing as Predictors of Ventricular Arrhythmias and Cardiac Mortality in Subjects With Cardiomyopathy
Carpio, Freddy Del, Gharacholou, S. Michael , Scott, Christopher S, Nkomo, Vuyisille T., Nkomo, Vuyisile T. , López-Jiménez, Francisco , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.15331 Get It

Introduction: Clinical predictive value of transient prolonged ventricular conduction and repolarization during right ventricular (RV) pacing have not been studied. Hypothesis: Ventricular conduction and repolarization prolongation during RV pacing predict risk of arrhythmic and mortality events. Methods: Electrophysiology studies in 501 patients with cardiomyopathy (CM) were reviewed. Duration changes of QRS and QT interval during pacing from the RV apex were measured. Subjects were followed up for a mean of 3.2 years for arrhythmic events and total mortality. Results: Participants had a mean age 65 yrs, 80% male, 74% funcional class II or III, and a mean EF of 33.1%. A paced QRS duration > 190 ms was associated with more severe CM and in multi-variable analysis it was associated with a 3.5 times higher risk of ventricular arrhythmias or appropriate defibrillator therapy (HR 3.5, 95% CI 2.3-5.4, p<0.01) and 2.6 times higher risk of total mortality or arrhythmic events (HR 2.6, 95% CI 2.3-3.4, p<0.01) compared to a paced QRS duration <190 ms, independent of baseline EF or baseline QRS duration, and after adjustment for electrophysiology study results, baseline functional class, type of cardiomyopathy and other relevant clinical factors. Similarly a QTc interval during RV pacing > 620 ms was associated with a 2.7 times higher risk of arrhythmic events compared to a QTc interval during RV pacing < 620 ms. Conclusions: Prolongation of ventricular conduction (QRS > 190 ms) and repolarization (QTc > 620 ms) observed during RV pacing in subjects with CM are associated with higher risk of arrhythmic events, defibrillator therapies and all-cause mortality.
Abstract 14833: National Trends in Complications and 30-day Re-hospitalization After Lead Removal/extraction: Analysis From a Cohort Of 42,878 Patients
Mulpuru, Siva K. , Sangaralingham, Lindsey R. , Mawangi, Raphael, Deshmukh, Abhishek , Shah, Nilay D. , Killu, Ammar M. , Cha, Yong‐Mei , Friedman, Paul A. , Noseworthy, Peter A. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14833 Get It

Introduction: As the US population ages and indications for cardiac device implantation expand, there is a concomitant increase in patients undergoing lead removal/extraction (LR/E).. We sought to examine trends in outcomes and complications associated with LR/E. Methods: We conducted a retrospective analysis using data from a large U.S. commercial insurance database (privately insured and Medicare Advantage patients) identifying all patients undergoing LR/E between 2004 and 2013 with at least one year continuous medical plan enrollment prior to LR/E (to identify baseline comorbidities). Using ICD9 codes and CPT codes, major complications (hemorrhage requiring transfusion, vascular injury, pericardial complications, respiratory complications, cerebrovascular complications, and requirement for cardiac surgery) associated with LR/E and 30-day readmission rates were evaluated. Results: Among 42,878 patients who underwent LR/E (median age of 62 ( 54, 72) years, 70% male); approximately 1 in 40 experienced a major adverse event (2.4%) during the study period. Respiratory complications were the most common complication and 311 patients required cardiac surgery. 30-day readmission occurred in 11.1% of the total population. The most common reasons for readmission were heart failure exacerbation (18.7%) and device related complications (13.2%). Conclusion: The observed complication rates after LE/R in clinical practice are similar to those seen in recent clinical trials and have been relatively stable over the past 10 years.
Abstract 12776: Long Term Mortality With Right Ventricular Apical Versus Septal Pacing
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Aung, Htin , Zyl, Martin van , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Aung, Htin, Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12776 Get It

Introduction: Right ventricular apical (RVA) pacing appears to have detrimental effects on cardiac function and long term outcomes. Right ventricular non-apical (RVNA) pacing, especially in the septal position, has been postulated as an alternative that may lead to less morbidity and mortality. Prior studies have shown conflicting results and been limited by small numbers and short follow-up. We aimed to determine if right ventricular septal lead position was associated with a reduction in long-term mortality compared to RVA lead position. Methods: Patients who underwent dual-chamber pacemaker implantation from 2004 through 2013 were evaluated for right ventricular lead position based on chest radiographs. Lead positions were divided in to apical or non-apical. Non-apical lead positions were subdivided to isolate a septal lead position group. Mortality was compared between these groups. Results: During the study period, 3456 patients underwent dual-chamber pacemaker placement and had images appropriate for lead position evaluation. The group was 53.5% male with a mean age of 74 ± 13 years. RVNA lead position was found in 976 (28.2%) patients, including 243 (7.0%) with a septal position. There was no significant difference in age or prior heart failure diagnosis between groups. Kaplan-Meier survival analysis did not reveal a significant difference in mortality between patients with RVA versus RVNA lead position during 5 year follow-up (p = 0.82). However, septal lead position was associated with a significantly lower mortality compared with RVA position (p = 0.03) (figure). Conclusions: Right ventricular septal lead position is associated with a lower long-term mortality than RVA lead position. This has substantial implications regarding the preferred site for ventricular pacing lead placement.
Abstract 12443: In-Beam PET Verification of Catheter-free Arrhythmia Ablation by Scanned Carbon-12 Ion Beam Irradiation
Fiedler, F. , Helmbrecht, S. , Constantinescu, A., Lugenbiel, Patrick , Prall, Matthias, Kaderka, Robert, Takami, Mitsuru , Eichhorn, Anna, Thomas, Dierk , Katus, Hugo A. , Johnson, Susan B., Parker, Kay, Asirvatham, Samuel, Packer, Douglas L. , Lehmann, H. Immo , Graeff, Christian , Prall, M. W., Richter, Daniel , Parker, Kay, Debus, Jürgen , Bert, Christoph , Durante, Marco

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12443 Get It

Introduction: Highly precise irradiation using carbon-12 (12C) ions is a new means for catheter-free ablation. Besides energy deposition leading to the dose distribution, nuclear interactions lead to by-product β+-activity that can be measured using positron-emission-tomography (PET). Hypothesis: In-beam PET scanning during focused myocardial irradiation using 12C can adequately depict 12C dose deposition. Methods: Pigs were irradiated with 25, 40, and 55 Gy for AV node (AVN), LA-PV junction, and local LV freewall ablations. PET measurement was performed by means of a double head camera system installed at irradiation site. Coincidences were captured in end-expiration during beam extraction pauses of the accelerator. Results: Evaluation of PET images was qualitatively performed using the coronal plane of the activity distribution superimposed on the contrast-CT in the center of the target contour. Strong β+-activities were measured in AVN and LV ablations. In AVN ablations, activity was localized to the target location, without target activity spreading to the level of the aortic root or coronary sinus (Figure A). Local LV irradiations revealed strong activity in the target location, slightly extending into left lung and chest wall (Figure B). In 55 Gy animals, the cardiac entry channel showed increased activity, decreasing in 40 Gy and more so in 25 Gy animals. Conclusion: This is the first study applying in-beam PET to track 12C dose-deposition into the target location for catheter-free ablation in intact animals. Correlation of β+-activity to electrophysiological outcome, lesion induction, and potential side-effects may be critically important in dosing therapy and predicting outcomes.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation
Killu, Ammar M. , Sugrue, Alan , Hodge, David O. , Munger, Thomas M. , Mulpuru, Siva K. , Packer, Douglas L. , Friedman, Paul A. , Al‐Hijji, Mohammed , McLeod, Christopher J. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112 Get It

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.
Abstract 2750: Multi-detector Computed Tomography Is An Accurate Screening Imaging Modality For Detection Of Thrombus In Patients Undergoing Catheter Ablation Of Atrial Fibrillation
Martinez, Matthew W. , Kirsch, Jacobo , Williamson, Eric E. , Cha, Yong‐Mei , Friedman, Paul A. , Ommen, Steve R. , Callahan, Mark J., Syed, Imran S., Feng, DaLi, Beinborn, Douglas S., Packer, Douglas L. , Brady, Peter A. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_610-b Get It

Introduction Multi-detector computed tomography (MDCT) is commonly used to identify pulmonary vein and left atrial anatomy prior to catheter ablation for atrial fibrillation (CAAF). Additionally, transesophageal echocardiography (TEE) is utilized to exclude left atrial/left atrial appendage thrombus (ICT). Whether MDCT alone can be used to exclude thrombus obviating the need for TEE is unknown. Methods All Pts referred for CAAF at Mayo Clinic between March 2004 and October 2006 were included. Clinical data (including CHADS score), 64 slice MDCT (non-ECG gated), TEE and intra-cardiac echocardiograph (ICE) were all performed and recorded. Image data was reviewed independently and blinded. The left atrial appendage (LAA) was defined as fully opacified or underfilled. An underfilled LAA was further interrogated using a region of interest over the filling defect and mean attenuation in Hounsfield Units (HU) were recorded. Results In total 400 Pts (mean age 56 ± 10 yrs; 76% male; EF 56 ± 10 % ) were included. 362 had no ICT by TEE nor filling defect by MDCT. 38 patients had an underfilled LAA in whom ICT was confirmed by TEE in 7. Sensitivity and specificity of MDCT for ICT was 100% and 92% respectively with a NPV of 100%. In 19 Pts with underfilled LAA’s, a mean LAA emptying velocity was found to be significantly reduced at 26 cm/s (6 – 61 cm/s). Those with a thrombus had a mean attenuation value below 70 HU. CHADS2 score was higher (2.0 versus 1.0) in Pts with LAA filling defect versus those without LAA filling defect. All Pts with confirmed thrombus were taking Warfarin. ICT was not seen in any Pts aged <52 yrs with CHADS score ≤1. Conclusions Sensitivity and specificity of MDCT for detection of LAA thrombus is high. LAA filling defects on MDCT correlate with low emptying velocities by TEE and low attenuation value in HU. These data would suggest that in the absence of MDCT filling defect, no further imaging is required. TEE should be utilized prior to CAAF to investigate MDCT filling defects. Multidetector Computed Tomography for the Detection of LAA Thrombus