Background: Despite advances in surgical techniques and perioperative care, pancreatic resections such as pancreaticoduodenectomy (PD) and distal pancreatectomy (DP) remain high-risk procedures. Postoperative complications significantly impact morbidity, mortality, and patient quality of life. Methods: This narrative review summarizes recent literature on major complications following pancreatic surgery, including postoperative pancreatic fistula (POPF), delayed gastric emptying (DGE), and post-pancreatectomy hemorrhage (PPH), with an emphasis on incidence, risk factors, outcomes, and current preventive strategies. Results: POPF is a leading complication, occurring in 5–22% of cases and often linked with sepsis and hemorrhage. Key risk factors include high BMI, soft pancreatic texture, and small duct size. Preventive measures like Pasireotide, modified anastomosis techniques, and neoadjuvant therapy show variable success. DGE affects up to 57% of PD patients and is associated with prolonged recovery; antecolic reconstruction and erythromycin may reduce incidence. PPH, though less frequent (3–13%), can be life-threatening, particularly when secondary to POPF. Endovascular approaches are now favored for late arterial bleeding. Other complications include wound infections, abscesses, bile leaks, and pulmonary issues, all contributing to extended hospital stays and diminished quality of life. Conclusions: Pancreatic surgery continues to carry significant risks, with POPF, DGE, and PPH being the most impactful complications. While multiple interventions have shown promise, standardized protocols and predictive tools are still needed. Surgery should be performed in high-volume centers with experienced multidisciplinary teams to optimize outcomes.
B-265 Significance of CSF Aß42/40 and p-Tau181/Aß42 Ratio Discrepancy in the Diagnosis of Alzheimer’s Disease
Abstract Background Alzheimer’s disease (AD) cerebrospinal fluid (CSF) biomarkers, including the Aß42/40 and p-tau181/Aß42 ratios, are used in clinical practice to detect the presence of amyloid pathology for the diagnosis of AD. However, in some instances, discrepancies between Aß42/40 and p-tau181/Aß42 are observed. Such discrepancies may introduce uncertainties in the clinical management of patients presenting with cognitive decline. Identifying the underlying causes of these discrepancies and determining which biomarker abnormalities better predict disease progression is crucial to enhancing confidence in the use of these CSF biomarkers for the diagnosis of AD. This study aims to investigate the discordance between the Aß42/40 and p-tau181/Aß42 ratios, evaluate the frequency of these discrepancies, and identify potential causes. Methods Data from 958 individuals who had both CSF Aß42/40 and p-tau181/Aß42 tested at Mayo Clinic Laboratories between 2022 and 2024 and where the tests were ordered in CSF collected during the same lumbar puncture procedure were included. Cases with an inadequate sample collection, which could cause a false decrease in Aß42 concentrations, were excluded from the analysis. Aß42/40 was measured using the Fujirebio LUMIPULSE assays and reported as negative, likely positive, or positive. For this analysis, likely positive and positive results were combined and considered as positive (<0.072). P-tau181/Aß42 was measured using the Roche Elecsys assays and above 0.028 was considered positive. Statistical analyses were conducted using R Studio. Results Aß42/40 was positive in 69.1% of cases (n=661), while p-tau181/Aß42 was positive in 62.1% (n=594). There were 8.0% discordant cases (n=77). Most frequently, the discordant cases had an abnormal Aß42/40 with a normal p-tau181/Aß42 (Aß42/40+/p-tau181/Aß42-; n=72, 94%). Compared to the concordant Aß42/40+/p-tau181/Aß42+ group, the discordant Aß42/40+/p-tau181/Aß42- group showed significantly higher Aß42 concentrations (p <0.001, median [pg/mL]: 878.5 vs 587.0, respectively); whereas p-tau181 concentrations were significantly lower (p <0.001, median [pg/mL]: 19.3 vs 32.1, respectively). Among the Aß42/40+/p-tau181/Aß42- group, 30 cases exhibited abnormally low Aß42 and normal p-tau181, possibly reflecting early-stage AD. There were 41 cases with a normal Aß42 concentration despite an abnormal Aß42/40, possibly reflecting an overall higher production of Aß peptides resulting in an increased Aß40 peptide (median [pg/mL]: 12627 compared to 9487 in the low Aß42 and normal p-tau181 cases (n=30); p <0.001). Of these 41, 19 showed normal Aß42 but elevated p-tau181 concentrations where the use of Aß42/40 compensated for the overall higher production of Aß peptides, resulting in an abnormal ratio. In contrast, the p-tau181/Aß42 ratio was not able to normalize for these differences, leading to a normal ratio. Conclusion While overall concordance was 92.0%, our findings suggest that discrepancies between CSF Aß42/40 and p-Tau181/Aß42 are more often due to the presence of an abnormal Aß42/40 and a normal p-Tau181/Aß42. Two potential explanations for these discrepancies are early-stage AD or higher production of Aß peptides in some individuals. In the latter, differences in amyloid production would be normalized by ratios of the same biomarker (i.e. Aß42/40) but not by ratios of different biomarkers (i.e. p-Tau181/Aß42).
B-223 DMD Duplications Identified by Carrier Screening Should NOT Automatically Be Classified as [Likely] Pathogenic: Data from Long-Read Sequencing of 15 Cases
Abstract Background Pathogenic variants in the DMD gene are associated with Duchenne and Becker muscular dystrophy (DMD/BMD). Professional medical societies currently recommend DMD carrier screening for all patients who are pregnant or considering pregnancy. Such testing may identify intragenic duplications of DMD (i.e., involving one or more exons but fully contained with the gene) in patients without a personal or family history of DMD/BMD. These incidentally detected DMD intragenic duplications, however, pose significant challenges for variant interpretation. Pathogenicity of an intragenic duplication depends on its structural configuration. Tandem duplications may cause reading frame disruption and gene loss-of-function; conversely, non-tandem duplications may not disrupt gene function. Current carrier screening assays cannot determine the structural configuration of an intragenic duplication. The current guidelines (e.g., the ClinGen PVS1 decision tree) presume intragenic duplications are in tandem unless proven otherwise. If this presumption of tandem configuration is inaccurate, it may lead to overestimation of variant pathogenicity, potentially resulting in unnecessary invasive procedures (e.g., amniocentesis for prenatal diagnosis) and/or having other negative impacts with regards to prenatal decision-making. This study aims to evaluate the validity of this presumption for incidentally detected DMD intragenic duplications. Methods We performed high-coverage whole-genome long-read sequencing on the PromethION instrument (Oxford Nanopore Technologies) for 15 cases with previously identified DMD intragenic duplications. Among these cases, four had personal or family history of DMD/BMD, while 11 had no known history (i.e., incidentally detected). The structural configurations of the duplications were determined by an in-house bioinformatics tool and manual inspection of the alignment files. Results In all 4 cases with a known personal or family history of DMD/BMD, the DMD intragenic duplications were confirmed to be in tandem, aligning with expectations of their pathogenicity. Interestingly, among the 11 cases with incidentally detected DMD intragenic duplications, seven (64%) were found to involve interspersed duplications. In five of these seven interspersed duplication cases, the involved DMD exons were co-duplicated with distinct segments of the Xp arm located 0.5–30 Mb away, forming complex structural variants. In another case, the duplicated DMD exons have inserted into the Xq arm, about 90 Mb downstream of DMD. The final case involved the duplicated DMD exons inserted into a repetitive region most consistent with 9q12 (i.e., the 9qh region). Conclusions Our study reveals that while DMD intragenic duplications in patients with a personal or family history of DMD/BMD were consistently in tandem, a substantial 64% of incidentally detected DMD intragenic duplications were not in tandem. These findings have important implications for both clinicians and laboratorians. They challenge the presumption of tandem configuration for DMD intragenic duplications in individuals where the variants were identified incidentally, e.g., through carrier screening in those without a family history of DMD/BMD. In these cases, we recommend classifying the DMD intragenic duplications as variants of uncertain significance (VUS), unless there is evidence of tandem configuration.
B-183 Teclistamab: a bispecific monoclonal IgG lambda therapeutic is observable on serum immunofixation and mass-fix
Abstract Background Monoclonal antibody therapies (t-mabs) are known to interfere in serum immunofixation, as they show up as a discrete band. Until recently, most of the t-mabs were IgG kappa monoclonal immunoglobulins, and laboratories were familiar with the clue of a cathodal migrating IgG kappa in a patient sample, suggesting this could be daratumumab or another t-mab in the report. However, with the advent of novel antibody-based medications, identification via traditional laboratory methods has grown more complex. Teclistamab-cqyv is an IgG4 lambda T-cell engager bispecific antibody targeting B-cell maturation antigen (BCMA) and CD3 on T cells, used in relapsed and refractory multiple myeloma. The goal of this study was to determine if teclistamab could be detected on serum immunofixation and mass-fix. Methods Residual waste serum samples with no monoclonal protein via mass-fix (a MALDI-TOF based assay used in place of serum immunofixation) and variable polyclonal background were used to spike teclistamab (n=3). Briefly, one sample had total IgG < 500 mg/dL measured by nephelometry on a Siemens BNII (431 mg/dL, hypo gamma), a second sample had IgG within reference intervals (779 mg/dL, normal gamma) and the third sample had IgG > 1600 mg/dL (1950 mg/dL, polyclonal hypergamma). Each sample was divided into 3 aliquots and spiked with teclistamab (Tecvayli, Johnson &Johnson) obtained from the pharmacy, at final concentrations of 10, 20, and 40 mg/dL in the serum samples. The nine artificial samples were subjected to immunofixation electrophoresis (Sebia) and a new monoclonal protein study using mass-fix, a laboratory developed test. Results In the serum immunofixation experiments, a single discrete IgG lambda band was visible in the hypogamma and normal gamma samples (Table 1) when teclistamab was present at 20 mg/dL or 40 mg/dL. No bands were observed for the 10 mg/dL spike in hypos or normals. No teclistamab was detected at any concentration in the hypergamma sample. When mass-fix was performed, monoclonal protein spikes consistent with the expected mass of the two unique lambda light chains associated with teclistamab (22624Da and 22636Da) were identified in the hypo and normal gamma samples at the 3 concentrations tested: 10, 20, and 40 mg/dL. No mass-fix spikes were seen above the polyclonal spectra in the hypergamma samples. Conclusion The polyclonal background of immunoglobulins in a serum specimen plays a significant role in the identification of any monoclonal protein. Teclistamab is a new IgG lambda t-mab with potential to show up as an interference in both immunofixation and mass-fix, depending on the amount of polyclonal IgG present. Without positive identification, teclistamab presence could complicate interpretation of a patient’s response to treatment. This proof-of-concept study shows that mass-fix can detect smaller concentrations of teclistamab than immunofixation, therefore would be more prone to identifying this t-mab than labs employing the gel-based immunofixation method.
B-162 Optimizing Thyroid Function Testing: Reducing Unnecessary Orders and Enhancing Patient Care Through Evidence-Based Cascade Algorithms
Abstract Background Thyroid function testing is a common laboratory service that can be optimized by implementing evidence-based algorithms. The thyroid function cascade testing approach at Mayo Clinic Labs is utilized to effectively evaluate and monitor functional thyroid status. The cascade begins with thyroid-stimulating hormone (TSH) as a screening marker. When TSH levels are normal, no additional testing is necessary. When the TSH result is abnormal, appropriate follow-up free T4, total T3, and/or TPO testing will automatically be performed. Providers at our institution can order thyroid function testing with this cascade testing approach or as standalone individual orderable tests. Initial data analysis showed patterns of TSH ordered concurrently with free T4, total T3, and/or anti-TPO. Further analysis revealed that a high number of concurrently ordered tests would not have been necessary had the algorithmic approach been followed. This opportunity for improvement led to the thyroid function testing initiative to direct providers to order the cascade test rather than individual thyroid tests, thereby reducing concurrent and unnecessary testing to improve patient care. Methods The initiative involved creating a new Epic order panel directing providers to order the cascade rather than the individual orderable tests. This intervention is a soft stop that allows providers to proceed by ordering individual tests if desired. We evaluated the impact of the initiative on test utilization, cost savings, and quality indicators using pre- and post-intervention data from all Mayo Clinic sites over a 9-month period. We compared the monthly volumes of concurrent and unnecessary orders of Free T4, Total T3, and TPO before and after the intervention. Concurrent orders were defined as tests collected from the same patient on the same date and time as TSH tests. Unnecessary orders were defined as tests that were outside the reflex range according to the thyroid function ordering algorithm. Cost savings were calculated based on the 2024 CMS reimbursement rates for the associated test CPT® codes. We also monitored and addressed feedback and requests from providers and laboratory staff throughout the initiative. Results The intervention resulted in a 20% average monthly reduction in concurrent orders and an 18% average monthly reduction in unnecessary orders of free T4, total T3, and anti-TPO tests. Estimated savings based on 2024 CMS reimbursement rates are $5,000 monthly and nearly $60,000 annually. Thyroid testing quality was also improved by aligning with clinical guidelines, reducing over-testing, and minimizing the risk of misdiagnosis. Conclusion The thyroid function testing initiative was a successful laboratory stewardship project that reduced redundant testing, improved patient care, and reduced costs. The initiative demonstrated the feasibility and effectiveness of using evidence-based reflex algorithms to optimize laboratory testing. The lessons learned include assessing all tests related to the disease condition to mitigate potential unintended increases in test usage and accounting for patient groups that are not covered by the intended algorithm*s target population. Future directions include expanding the cascade approach to other areas of laboratory medicine, evaluating the long-term outcomes of the initiative, and engaging with providers to ensure the adoption of the initiative.
B-123 Clinical Implication of Light Chain Fragmentation in Patients with Monoclonal Gammopathies
Abstract Background The diagnosis of monoclonal gammopathies relies on the detection of monoclonal immunoglobulins (M-proteins) in serum or urine. Mass-Fix utilizes matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) to detect and quantify M-proteins. This method employs immunoaffinity enrichment using antibodies against heavy chains (HC) and light chains (LC), followed by MS analysis to determine M-protein isotypes. Mass-Fix has also revealed novel M-protein characteristics, including LC glycosylation and fragmentation, facilitated by measuring the mass of LC. LC glycosylation is as an independent risk factor for disease progression of monoclonal gammopathy of undetermined significance (MGUS), while light chain fragments have been postulated as the origin of amyloid light chain (AL) plaques. Since Mass-Fix enriches intact immunoglobulins before dissociating LCs, it potentially enhances fragment detection. However, the precise nature and clinical significance of these fragments remain to be fully elucidated. Methods Mass-Fix serum results from Mayo Clinic patients tested from September 10, 2018, to October 1, 2024, were reviewed for the presence of M-protein and LC fragments. The frequency and the isotype of fragment LC fragments was determined in the M-protein positive cohort (n=15410). Patients diagnosed with either MGUS (n=6996), AL amyloidosis (n=315), or both (n=32) who had positive M-protein results on Mass-Fix, either prior to or within one month after the diagnosis, were included for a retrospective clinical association study of LC fragments and disease. To validate that these fragments were not artifacts of MS analysis, PAGE gel analysis and Western blots were performed using clinical residual serum from 9 patients: 2 IgG/kappa and 3 IgG/lambda patients with detectable LC fragments and 2 IgG/kappa and 2 IgG/lambda patients without fragments. Samples were purified using antibodies against gamma heavy chains and reduced with TCEP prior to gel electrophoresis and Western blot. Results Of the 15410 patients with monoclonal proteins detected by Mass-Fix, 2896 (18.7%) had detectable LC fragments; kappa fragments in 1533 and lambda fragments in 1363. Most often, the fragments were observed in pairs, with combined molecular weight typically equaled that of the full-length monoclonal LC present in the same sample. LC fragments were observed more frequently among patients diagnosed with AL amyloidosis (118/347=34%) compared to those without the diagnosis (685/6996=10%), with an odds ratio of 4.75 (95% CI, 3.75-6.01). PAGE with Coomassie blue staining revealed bands with sizes representing LC fragments in the five M-protein samples with detectable LC fragments on Mass-Fix, while no such bands observed in those without LC fragments. Western blot using anti-kappa or anti-lambda antibodies confirmed the identity of the bands with higher molecular weight as a fragment of LC in each of the IgG/kappa and IgG/lambda samples. Conclusion Mass-Fix is able to discriminate LC fragments from intact LC based on their sizes. The detection of LC fragments with Western blot without ionization suggests a biological origin rather than analytical artifacts from MS. The clinical association study suggests that LC fragments may have utility in increasing the suspicion of AL amyloidosis in M-protein positive patients with LC fragments, potentially facilitating earlier intervention and improving patient outcomes.
B-124 Evaluation of Anti-Citrullinated Peptide Antibody (ACPA) Result Normalization as Defined in the 2010 Rheumatoid Arthritis Classification Criteria Recommended by American College of Rheumatology/Alliance of Associations for Rheumatology (ACR/EULAR)
Abstract Background Anti-citrullinated peptide antibodies (ACPA) (tested as anti-cyclic citrullinated peptide [CCP] antibodies) are frequently ordered in the evaluation of patients with suspected rheumatoid arthritis (RA) and considered to be specific biomarkers for RA. The 2010 American College of Rheumatology/European Alliance of Associations for Rheumatology (ACR/EULAR) classification criteria for RA include both ACPA and rheumatoid factor in their scoring system, despite limited standardization of commercially available anti-CCP antibody tests. In an attempt to overcome this limitation, the classification criteria recommends using multiples of the assay-specific upper limit of normal (ULN) to normalize results and standardize classification. This study evaluates the correlation between normalized results from different assays and the concordance in result classification according to the ACR/EULAR criteria. Methods A total of 265 samples with ACPA ordered as part of routine clinical care were tested on four commercial anti-CCP antibody assays, including QUANTA Lite CCP3 IgG ELISA (Werfen) (Negative: <20 Units), QUANTA Flash CCP3 chemiluminescence immunoassay (Werfen) (Negative: <20 Chemiluminescent Units), EUROIMMUN Anti-CCP ELISA (IgG) (EUROIMMUN) (Negative: <=5 Relative Units/mL), and Elecsys anti-CCP electrochemiluminescence immunoassay (Roche) (Negative: <17.0 Units/mL). The QUANTA Lite and EUROIMMUN ELISA were performed on the Agility platform (Dynex), QUANTA Flash was performed on BioFlash platform (Werfen), and Elecsys anti-CCP was performed on Cobas e601 platform (Roche). All testing was performed according to manufacturer’s instructions. Results from each assay were converted to the multiples of assay-specific ULN as the normalized results. Regression analysis was performed, and the coefficient of determination (R²) was calculated to assess the correlation between paired assays. The concordance in result classification across assays was also investigated using both assay specific cut-offs and the ACR/EULAR criteria-defined cut-offs: Negative (<=1xULN), Low positive (>1xULN and <3xULN), High positive (>=3xULN). Results Using assay-specific cut-offs, 63 samples were negative on all assays. 202 samples were positive on at least one assay, of which 79 (39%) were positive across all assays. The overall concordance of qualitative result was 54% ([63+79]/265). After result normalization using multiples of assay-specific ULNs, the highest correlation was observed between the EUROIMMUN ELISA and Elecsys anti-CCP (R²=0.83), despite differences in methodology and manufacturer. The lowest correlation was observed between QUANTA Lite and QUANTA Flash (R²=0.49), even though both are from the same manufacturer although methodologies differ. When applying the criteria-defined cut-offs, 64 samples were negative on all assays. 130 samples were classified as low positive on at least one assay; however, only 3 (2%) samples were classified as low positive across all assays. 103 samples were classified as high positive on at least one assay, of which 54 (52%) were classified as high positive across all assays. With result normalization, the overall concordance in result classification across all assays using the criteria-defined cut-offs were 46% ([64+3+54]/265). Conclusion Despite normalization using multiplies of assay-specific ULN values, the inter-assay correlation remains suboptimal, and the concordance in result classification is limited. These findings suggest that the anti-CCP antibody results from different assays may not be interchangeable even after normalization as recommended by current criteria, potentially impacting disease classification.
B-112 HLA-DQ Genotypes as Predictors of Serological Positivity for Celiac Disease in Pediatric Patients
Abstract Background Celiac disease (CeD) is a chronic autoimmune disorder that can affect people of any age. Both ingestion of gluten and the presence of human leukocyte antigens (HLA)-DQ2 or DQ8 are required for disease development. In adults, correlation between HLA-DQ2/DQ8 allele combinations and tissue transglutaminase (tTG) antibody positivity has been well described. In comparison, this association in pediatric patients is less defined. In this study, we evaluated the roles of HLA-DQ2 and HLA-DQ8 as predictors of tTG-IgA positivity in a pediatric cohort, aiming to enhance understanding of CeD risk assessment in this diagnostic group. Methods Retrospective data were collected from individuals who underwent CeD diagnostic testing at Mayo Clinic Laboratories between 2011 and 2024; all patients were tested for total IgA, HLA-DQ typing, and tTG-IgA. Total IgA was measured using quantitative nephelometry on the BN™ II System (Siemens); HLA-DQ typing was performed using reverse sequence-specific oligonucleotide (SSO) DNA typing (LABType SSO kits, One Lambda, Thermo). tTG-IgA was tested using an enzyme-linked immunosorbent assay (QUANTA Lite® h-tTG IgA, Werfen Diagnostics). Those with total IgA below the age-specific reference interval were excluded from this analysis. Logistic regression was used to evaluate the association between HLA-DQ haplotypes and tTG-IgA positivity to assess the risk gradient across different HLA-DQ genotypes in children. Results The cohort identified in this study consisted of 115,499 individuals for whom total IgA, HLA-DQ typing and tTG-IgA testing was performed. Within this cohort, 20,676 (17.9%) were pediatric patients (age<=18 at the time of testing). Pediatric patients tested for CeD exhibited a slightly higher prevalence of at least one copy of HLA-DQ2 or DQ8 compared to adults (57.6% vs 55.4%, p<0.001). Additionally, these patients showed significantly higher rates of tTG-IgA positive across all genotypes, particularly those carrying HLA-DQ2.5 or DQ8, with positivity rates 1.2 to 2.3 times higher than in adults (p<=0.01). However, in non-permissive genotypes, the positivity rates were 0.3% (p=0.95), for both populations, indicating comparable specificity. Individuals with homozygous HLA-DQ2.5/DQ2.5 and HLA-DQ2.5/DQ2.2 showed the highest risks for tTG-IgA positivity with ORs of 85.7 (95% CI: 55.1-137.7) and 78.5 (95% CI: 51.3-124.3), respectively. Moderate risk was observed for HLA-DQ2.5/DQ8 with an OR of 49.0 (95% CI: 32.1-77.3), followed by single copy HLA-DQ2.5 (OR=35.0, 95% CI: 24.0-53.4) and homozygous HLA-DQ8/DQ8 (OR=21.7, 95% CI: 11.7-39.4). Although single copies of HLA-DQ2.2 and HLA-DQ8 showed lower risks with ORs of 5.4 and 8.9 (95% CI: 3.2-9.2 and 5.7–13.9), their combination increased the OR to 22.6 (95% CI: 13.0-39.2), similar to homozygous HLA-DQ8. Conclusion This large cohort study demonstrates the predictive value of HLA-DQ genotypes for pediatric CeD seropositivity. Notably, pediatric patients showed slightly higher prevalence and positivity rates compared to adults, particularly among those with homozygous HLA-DQ2.5/DQ2.5 and HLA-DQ2.5/DQ2.2 genotypes, which exhibited the highest risks for tTG-IgA positivity. The findings confirm that HLA-DQ2.5 is the main driver of serology positivity and suggest that HLA-DQ8 also influences serological positivity in pediatric patients, which can enhance targeted screening and potentially inform decisions regarding the necessity of duodenal biopsy.
B-094 Evaluating the Impact of Stabilized Calibrator on Free Light Chains Reference Intervals
Abstract Background The Freelite serum free light chain (FLC) assay has been widely used for detecting and monitoring monoclonal gammopathies. Reference intervals (RIs) established by Katzmann et al. in 2002 have served as the standard values for interpreting kappa/lambda FLC ratios. However, multiple reports suggested an assay drift and clinical laboratories started to move towards locally established RIs given the challenge in verifying original RIs. The assay drift over time increased kappa concentration measurements and was attributed to an interaction between the kappa FLC calibrator and serum proteins, including alpha-1-antitrypsin. A stabilized calibrator was developed to improve consistency of results with original RI. The objective of this study was to assess whether the new updated kappa calibrator would warrant a RI update. Methods Healthy adult donors’ serum samples were selected from the institution quality unit. Exclusion criteria included autoimmune diseases, cancers and renal disease. FLC measurements were obtained on the Optilite by turbidimetry using routine reagents for kappa (old lot); the new lot of reformulated kappa calibrator, and a single measurement for lambda FLC. FLC ratios were calculated with the old lot and new lot. All samples were tested by MASS-FIX to confirm absence of a monoclonal protein. Bootstrap resampling (10,000 replicates) estimated standard errors, with statistical significance defined as p < 0.05. Clinical significance was assessed per CLSI EP28-A3 guidelines. A RI was considered for partitioning by sex if the mean difference between males and females exceeded 25% of the RI width or if >4% of either sex had values beyond RI limits. Similar tests were applied to age groups (<60 and =60 years). Results 465 donors (48.2% male, 51.8% female) aged 30-89 years were used. Sixteen donors with incidental monoclonal proteins identified by MASS-FIX were excluded, for a final n=449. No clinically significant relationships of results were found with sex or age. The updated kappa calibrator resulted in a measurable shift down in FLC values with the new lot of reagents. The kappa FLC concentration and corresponding FLC ratio decreased by a median -12.1%, see table 1 for absolute values When reviewing Optilite results of the new lot, 98/449 samples were outside the kappa concentration original RI (21%). Lambda concentration RI was shifted up on Optilite when compared to original RI but passes verification (1.6% of samples, acceptance criteria < or =10%). 19 samples (4.2%) were outside the original RI for the FLC ratio of 0.26 to 1.65 (all >1.65), which was originally established as a 100% diagnostic range. The calibrator reformulation, while decreasing test results by >10%, was not sufficient to verify the original RI for kappa and still left a few cases outside the original diagnostic range for the FLC ratio. Conclusion This study assessed the impact of the stabilized calibrator on RIs for the Optilite Freelite assay. These findings suggest revisiting existing RIs to ensure continued accuracy in clinical interpretation and should be further evaluated with additional lots of reagents for robustness.
Abstract Background To develop and validate a sensitive live cell-binding assay using flow cytometry to detect a3ß4-ganglionic nicotinic acetylcholine receptor (gnAChR) antibodies for diagnosis of autoimmune autonomic ganglionopathy (AAG, a subset of autoimmune autonomic neuropathies). The current radioimmunoprecipitation assay (RIPA) method has high false positive rate and utilizes radioactivity. Methods HEK293 cells were transiently transfected to express human a3ß4-gnAChR subunits, along with NACHO and RIC3 chaperons, and GFP for detection. Transfected cells were treated with 1mM nicotine liquid for 18-22 hours prior to lifting cells for flow cytometry. The IBI (IgG Binding Index) was then calculated as the median fluorescence intensity (MFI) of AF647 of the a3ß4-gnAChR subunits expressing cells divided by the MFI of the AF647 HEK293 expressing cells. Humanized AChR-specific monoclonal antibody (mAb03) was used as a single-point calibrator. The cut-off index (COI) ratio is calculated by dividing the IBI obtained from a sample by the established IBI cut-off value of the mAB03 calibrator set by the assay. A ratio >1 indicates a positive result, while a ratio below 1 is negative. The study tested sera from 83 Mayo Clinic patients suspected of having autoimmune autonomic ganglionopathy (AAG), with a total of 100 samples collected over several years (40 from patients with clinically confirmed AAG, and 60 from patients without AAG), all previously positive for a3-gnAChR antibodies by RIPA. Additionally, 130 control samples were included: 90 from healthy individuals, 22 with hypergammaglobulinemia, and 18 with systemic lupus erythematosus. Results Median RIPA a3ß4-gnAChR value among 40 AAG patient samples was 2.58 nmol/L (range, 0.06-29.1 nmol/L) and among 60 non-AAG patients was 0.14 nmol/L (range, 0.01-4.43 nmol/L). The mAB03 calibrator median IBI value across assays was 2.1 (range, 1.6-2.7). The COI ratio was calculated using the calibrated IBI values. Thirty-eight of 40 AAG patient samples were considered positive, resulting in median IBI of 3.10 (range, 1.29-6.71); sensitivity 95%. None of non-AAG patients and controls were considered positive; median IBI of 0.38 (range, 0.14-0.51); specificity 100%. The two negative AAG patient samples (IBI, 0.43 and 0.43) were from patients in remission (treated with immune suppressants), and had RIPA titers of 0.06 nmol/L and 0.74 nmol/L. Conclusion The a3ß4-gnAChR-IgG flow cytometry assay has high sensitivity and specificity for AAG-related a3-AChR antibodies. It was able to distinguish AAG patients from non-AAG patients and controls effectively. The flow cytometry assay’s cut-off index ratio effectively identifies AAG patients while remaining negative for non-AAG and control samples.