OBJECTIVE Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications. RESULTS A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A 1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist’s armamentarium, especially with regard to its off-label use.
Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results
Background Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. Objective To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. Methods PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. Results A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study’s primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). Conclusions Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. Trial registration NCT02186561 .
Aneurysms with persistent patency after treatment with the Pipeline Embolization Device
The Pipeline Embolization Device (PED) was approved for the treatment of intracranial aneurysms from the petrous to the superior hypophyseal segment of the internal carotid artery. However, since its approval, its use for treatment of intracranial aneurysms in other locations and non-sidewall aneurysms has grown tremendously. The authors report on a cohort of 15 patients with 16 cerebral aneurysms that incorporated an end vessel with no significant distal collaterals, which were treated with the PED. The cohort includes 7 posterior communicating artery aneurysms, 5 ophthalmic artery aneurysms, 1 superior cerebellar artery aneurysm, 1 anterior inferior cerebellar artery aneurysm, and 2 middle cerebral artery aneurysms. None of the aneurysms achieved significant occlusion at the last follow-up evaluation (mean 24 months). Based on these observations, the authors do not recommend the use of flow diverters for the treatment of this subset of cerebral aneurysms.