Citations

Clear

114 citation(s) found for "Jabbour, Pascal".

O-065 Multicenter investigation into presentation, management and outcome of infectious intracranial aneurysms
Saad, Hassan , Newman, Sarah, Grossberg, Jonathan A , Cawley, C. Michael , Fox, C, Perez-Vaga, C, Burkhardt, Jan‐Karl , Salem, Mohamed M , Jabbour, Pascal , Starke, R, Lu, Victor M. , Levitt, M, Spiotta, Alejandro M , Alawieh, Ali , Dimisko, Laurie , Zohdy, Youssef M. , Pradilla, Gustavo , Jabbour, Pascal , Naamani, Kareem El , Schmidt, Richard F. , Gooch, Michael Reid , Abdelsalam, Ahmed , Levitt, M, Hertzberg, Vicki , Barrow, Daniel L. , Howard, Brian M

Mayo Clinic

SNIS 20th annual meeting oral abstracts | July 30, 2023 | Volume: No volume available | Issue: No issue available | Pages: A51.1-A51

10.1136/jnis-2023-snis.65 Get It

Aspiration Versus Stent‐Retriever as First‐Line Endovascular Therapy Technique for Primary Medium and Distal Intracranial Occlusions: A Propensity‐Score Matched Multicenter Analysis
Shaikh, Hamza , Khalife, Jane , Oak, Solomon , Abdalkader, Mohamad , Kass‐Hout, Tareq , Morsi, Rami Z. , Heit, Jeremy J. , Regenhardt, Robert W. , Diestro, Jose Danilo Bengzon , Ghozy, Sherief , Amllay, Abdelaziz , Dusart, Anne , Bellante, Flavio, Puri, Ajit S , Dyzmann, Christian , Kan, Peter , Berge, Jérôme , Barreau, Xavier , Nedelcu, Simona , Henninger, Nils , Marotta, Thomas R. , Stapleton, Christopher J. , Rabinov, James D. , Dofuku, Shogo , Capirossi, Carolina , Tjoumakaris, Stavropoula , Jabbour, Pascal , Khandelwal, Priyank , Biswas, Arundhati , Clarençon, Frédéric , Elhorany, Mahmoud , Premat, Kévin , Valente, Iacopo , Filipe, João Pedro , Varela, Ricardo , Quintero‐Consuegra, Miguel , Gonzalez, Nestor R. , Möhlenbruch, Markus , Costalat, Vincent , Chervak, Lina , Aziz, Yasmin , Bullrich, María Bres , Liebeskind, David S. , Alexandre, Andrea , Tancredi, Illario , Faizy, Tobias D. , Patel, Aman B. , Lubicz, Boris , Guenego, Adrien , Dmytriw, Adam A , Liebeskind, David S. , Heit, Jeremy J , Ghozy, Sherief , Diestro, Jose Danilo B , Gonzalez, Nestor R , Aziz, Yasmin , Regenhardt, Robert W , Henninger, Nils , Alexandre, Andrea M , Morsi, Rami Z , Varela, Ricardo , Siegler, James E. , Zhang, Linda , Klein, Piers , Nguyen, Thanh N. , Cancelliere, Nicole M , Sweid, Ahmad , Naamani, Kareem El , Meyer, Lukas , Forestier, Géraud , Rouchaud, Aymeric , Saleme, Suzana , Mounayer, Charbel , Fiehler, Jens , Kühn, Anna Luisa , Colasurdo, Marco , Marnat, Gaultier , Sibon, Igor , Das, Alvin S. , Ota, Takahiro , Yeo, Leonard Ll , Tan, Benjamin Yong‐Qiang , Martinez-Gutierrez, Juan Carlos , Salazar‐Marioni, Sergio , Sheth, Sunil A , Renieri, Leonardo , Mowla, Ashkan , Jabbour, Pascal , Khandelwal, Priyank , Pedicelli, Alessandro , Jesser, Jessica , Schiphorst, Adrien ter , Yedavalli, Vivek , Harker, Pablo , Sposato, Luciano A. , Gory, Benjamin , Hecker, Constantin , Killer-Oberpfalzer, Monika , Griessenauer, Christoph J. , Thomas, Ajith J , Hsieh, Cheng‐Yang , Radu, Răzvan Alexandru , Fahed, Robert , Weyland, Charlotte S. , Mendes Pereira, Vitor , Dmytriw, Adam A.

Mayo Clinic

Stroke: Vascular and Interventional Neurology | July 6, 2023 | Volume: 3 | Issue: 6 | Pages: No page available

10.1161/svin.123.000931 | PMID 41585056 Get It

Background For acute proximal intracranial artery occlusions, contact aspiration may be more effective than stent‐retriever for first‐line reperfusion therapy. Due to the lack of data regarding medium vessel occlusion thrombectomy, we evaluated outcomes according to first‐line technique in a large, multicenter registry. Methods Imaging, procedural, and clinical outcomes of patients with acute proximal medium vessel occlusions (M2, A1, or P1) or distal medium vessel occlusions (M3, A2, P2, or further) treated at 37 sites in 10 countries were analyzed according to first‐line endovascular technique (stent‐retriever versus aspiration). Multivariable logistic regression and propensity‐score matching were used to estimate the odds of the primary outcome, expanded Thrombolysis in Cerebral Infarction score of 2b–3 (“successful recanalization”), as well as secondary outcomes (first‐pass effect, expanded Thrombolysis in Cerebral Infarction 2c‐3, intracerebral hemorrhage, and 90‐day modified Rankin scale, 90‐day mortality) between treatment groups. Results Of the 440 included patients (44.5% stent‐retriever versus 55.5% aspiration), those treated with stent‐retriever had lower baseline Alberta Stroke Program Early Computed Tomography Scale scores (median 8 versus 9; P <0.01), higher National Institutes of Health Stroke Scale scores (median 13 versus 11; P =0.02), and nonsignificantly fewer medium‐distal occlusions (M3, A2, P2, or other: 17.4% versus 23.8%; P =0.10). Use of a stent‐retriever was associated with 15% lower odds of successful recanalization (odds ratio [OR], 0.85; [95% CI 0.74–0.98]; P =0.02), but this was not significant after multivariable adjustment in the total cohort (adjusted OR, 0.88; [95% CI 0.72–1.09]; P =0.24), or in the propensity‐score matched cohort (n=105 in each group) (adjusted OR, 0.94; [95% CI 0.75–1.18]; P =0.60). There was no significant association between technique and secondary outcomes in the propensity‐score matched adjusted models. Conclusion In this large, diverse, multinational medium vessel occlusion cohort, we found no significant difference in imaging or clinical outcomes with aspiration versus stent‐retriever thrombectomy.
Abstract Number ‐ 7: Final Angiographic, Clinical and Thrombus Composition Results of 1000 Patients in the EXCELLENT Registry
Zaidat, Osama O. , Hacke, Werner, Brinjikji, Waleed , Doyle, Karen, Inoa, Violiza , Humphries, William, Woodward, Keith, Bozorgchami, Hormozd, Boor, Stephan , Cohen, José E. , Taqi, Muhammad , Budzik, Ronald F. , Hussain, Shazam, Estrade, Laurent , Puri, Ajit S , Brekenfeld, Caspar , Nogueira, Raul G. , Andersson, Tommy , Yoo, Albert J. , Hanel, Ricardó A. , Jovin, Tudor G. , Fiehler, Jens , De Meyer, Simon F , Liebeskind, David S. , Haussen, Diogo C , Jabbour, Pascal , François, Olivier , Levy, Elad I. , Dashti, Shervin R , Schirmer, Clemens M. , Leacy, Reade De , Chitale, Rohan V , Siddiqui, Adnan H.

Mayo Clinic

Stroke: Vascular and Interventional Neurology | April 25, 2023 | Volume: 3 | Issue: S1 | Pages: No page available

10.1161/svin.03.suppl_1.007 Get It

Introduction EXCELLENT (NCT03685578; Cerenovus) is a large, prospective, international, real‐world registry of endovascular clot removal in acute ischemic stroke (AIS) with EmboTrap as the first line mechanical thrombectomy (MT) device, which included collection and analysis of the retrieved thrombus material. Methods Between September 2018 and March 2021, 1000 “all‐comer” patients were enrolled at 34 global sites (27 US, 5 EU, 1 UK, 1 Israel) and treated according to standard of care at each center (with Embrotrap as first line). The study employed blind endpoint evaluation, including a core imaging lab and an independent 90‐day mRS assessment. Retrieved clot was collected per each MT maneuver from 538 subjects across 26 sites and clot analysis was performed by independent central labs blinded to clinical data. Results mITT population included 998 subjects. Mean age was 69.9±14.18 years (range 18–102), 51.8% (517/998) subjects were female and 9.9% (97/997) had a pre‐stroke mRS 3–5. Baseline NIHSS was 15.6±6.87 (range 0–36); 10.1% (82/815) subjects had a large core (ASPECTS 0–5); 5.8% (57/990) had posterior stroke; 56.3% (523/929) underwent MT ≤ 6hrs of onset and 38.1% (380/998) received IV‐tPA prior to MT. First pass eTICI 2c‐3 was achieved in 38.3% (377/984) and final 2b‐3 in 94.5 % (930/984; median number of passes = 1) of subjects. 90‐day mRS≤2 or ≤pre‐stroke was 46.9% (429/915) and 90‐day all‐cause mortality was 19.0% (175/921). The univariate analysis of clot components showed high red blood cell and low platelet content were significant predictors of good mRS outcome (p < 0.001 and 0.009) and negative predictors of 90‐day mortality (p < 0.001 and 0.017, respectively). Conclusions This large multi‐center, all‐comer cohort reflects the population undergoing thrombectomy today in a real world‐setting. Final angiographic, clinical and thrombus composition results, along with multivariate analysis of predictors of clinical outcomes, will be presented at the time of the conference.
Abstract 28: First Pass Outcomes And Associated Clot Characteristics: Secondary Analysis Of The Excellent Registry
Zaidat, Osama O. , Hacke, Werner, Jovin, Tudor G. , Brinjikji, Waleed , Doyle, Karen, Inoa, Violiza , Humphries, William, Woodward, Keith, Bozorgchami, Hormozd, Boor, Stephan , Cohen, José E. , Taqi, Muhammad , Budzik, Ronald F. , Hussain, M. Shazam , Estrade, Laurent , Puri, Ajit S , Brekenfeld, Caspar , Jovin, Tudor G , Andersson, Tommy , Nogueira, Raul G. , Yoo, Albert J. , Hanel, Ricardó A. , Fiehler, Jens , De Meyer, Simon F , Liebeskind, David S. , Haussen, Diogo C , Jabbour, Pascal , François, Olivier , Levy, Elad I. , Dashti, Shervin R , Schirmer, Clemens M. , Leacy, Reade De , Chitale, Rohan V , Siddiqui, Adnan H.

Mayo Clinic

Stroke | February 2, 2023 | Volume: 54 | Issue: Suppl_1 | Pages: No page available

10.1161/str.54.suppl_1.28 Get It

Introduction: EXCELLENT (NCT03685578) is a global prospective, multicenter, real-world registry of mechanical thrombectomy for stroke with the EmboTrap device as first line treatment which includes clot collection and analysis. Aim of the study: To report the rates of clinical outcomes and clot characteristics associated with first pass reperfusion in EXCELLENT. Methods: Per pass angiographic outcomes assessed by an independent core lab were available in 984 subjects Analysis of clot from 538 cases was performed by independent central labs blinded to clinical data. 90-day mRS assessment was blinded to subject data. Results: First pass reperfusion of mTICI 2b-3 (63.2%) and 2c-3 (38.3%) was significantly predictive of mRS 0-2 or ≤pre-stroke (p=0.011 and p=0.016) but not all-cause mortality at 90 days (p=0.080 and p=0.123, respectively). Further, mTICI 2c-3 in one pass was associated with a higher rate of mRS 0-2 or ≤pre-stroke vs. mTICI 2c-3 reperfusion in >1 pass, (55.5% and 45.1%, respectively, p=0.013) and a rate of all-cause mortality at 90 days of 14.6% vs. 19.8% (p=0.097). Full patient characteristics and clinical outcomes are shown in Table 1. Notable clot composition findings included: RBC (%, mean±SD): mTICI 2c-3, 1 pass 47.69±22.25, mTICI 2c-3, >1 pass 43.86±19.05, (p=0.088); fibrin: mTICI 2c-3, 1 pass 23.20±13.80, mTICI 2c-3 >1 pass 25.40 ± 13.52 (p=0.131); von Willebrand factor (VWF): mTICI2c-3, 1 pass 16.09±14.62, mTICI 2c-3, >1 pass 19.42±17.15 (p=0.038). Conclusions: First pass reperfusion in the EXCELLENT registry was associated with better clinical outcomes at 90 days. Clots retrieved with first pass reperfusion had higher RBC and lower fibrin and VWF content compared to those who achieved reperfusion at greater than one pass.
Intrasaccular flow disruption for ruptured aneurysms: an international multicenter study
Diestro, Jose Danilo Bengzon , Dibas, Mahmoud , Adeeb, Nimer , Regenhardt, Robert W. , Vranic, Justin E. , Guenego, Adrien , Lay, Sovann V. , Balushi, Ali Al , Shotar, Eimad , Premat, Kévin , Möhlenbruch, Markus , Foreman, Paul M. , Vachhani, Jay A. , Župančić, Vedran , Hafeez, Muhammad Ubaid , Rai, Hamid, Tutino, Vincent M. , Mirshani, Shervin, Ghozy, Sherief , Alotaibi, Naif M. , Rabinov, James D. , Ren, Yifan , Goren, Oded , Piano, Mariangela , Michelozzi, Caterina , Elens, Stéphanie , Starke, Robert M. , Nguyên, Anh , Jones, Jesse , Psychogios, Marios, Spears, Julian , Bullrich, María Bres , Mayich, Michael , Salem, Mohamed M. , Burkhardt, Jan‐Karl , Jankowitz, Brian T. , Ulfert, Christian , Lubicz, Boris , Puri, Ajit S , Pero, Guglielmo , Asadi, Hamed , Siddiqui, Adnan H. , Ducruet, Andrew F. , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Stapleton, Christopher J. , Knopman, Jared , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Aziz‐Sultan, Mohammad Ali , Patel, Aman B. , Dmytriw, Adam A. , Shotar, Eimad , Saliou, Guillaume , Lylyk, Ivan , Vachhani, Jay A , Rai, Hamid , Tutino, Vincent M , Harker, Pablo , Ren, Yifan , Schirmer, Clemens M , Michelozzi, Caterina , Elens, Stephanie , Hassan, Ameer E , Nguyen, Anh , Jones, Jesse , Parra-Fariñas, Carmen , Salem, Mohamed M , Domingo, Ricardo A , Tawk, Rabih, Pero, Guglielmo , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Cuellar-Saenz, Hugo H , Dmytriw, Adam A , Siddiqui, Adnan H , Dibas, Mahmoud , Ghozy, Sherief , Diestro, Jose Danilo B , Regenhardt, Robert W , Hafeez, Muhammad U , Ulfert, Christian , Lay, Sovann V , Burkhardt, Jan‐Karl , Renieri, Leonardo , Naamani, Kareem El , Saliou, Guillaume , Lylyk, Iván , Rutledge, Caleb , Harker, Pablo , Schirmer, Clemens M. , Kühn, Anna Luisa , Hassan, Ameer E , Salehani, Arsalaan , Psychogios, Marios‐Nikos , Domingo, Ricardo A. , Huynh, Thien , Tawk, Rabih G. , Panni, Pietro , Griessenauer, Christoph J. , Du, Rose , Jabbour, Pascal , Limbucci, Nicola , Cuellar, Hugo , Cognard, Christophe

Mayo Clinic

Journal of NeuroInterventional Surgery | July 22, 2022 | Volume: 15 | Issue: 9 | Pages: 844-850

10.1136/jnis-2022-019153 | PMID 35868856 Get It

Background The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. Methods Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. Results The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. Conclusion There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.
Abstract W MP34: Safety and Efficacy of Hydrosoft Coils in the Treatment of the Aneurysm Neck: Preliminary Results From the GEL THE NEC Registry
Brinjikji, Waleed , Connelly, Beth B, Tubman, D, Jensen, Mary E. , Chaudry, I, Kallmes, David F. , Hoh, Brian L. , Kelly, Michael , Jabbour, Pascal , Hui, Ferdinand

Mayo Clinic

Stroke | March 20, 2022 | Volume: 45 | Issue: suppl_1 | Pages: No page available

10.1161/str.45.suppl_1.wmp34 Get It

Background and Purpose: The HydroSoft coil was developed to be placed along the aneurysm neck to enhance intracranial aneurysm healing. In order to better understand the safety and efficacy of Hydrosoft coils in treating the aneurysm neck, the GEL THE NEC multicenter registry was developed. We report immediate angiographic and clinical results of this prospective registry. Methods: The GEL THE NEC study was undertaken at 30 centers in 5 countries. Patients aged 21-90 years with a ruptured or unruptured aneurysm 3-15 mm in size were eligible for enrollment. For each patient the following data were obtained: demographics and comorbidities, aneurysm geometry, use of adjunctive devices, immediate angiographic outcomes, and early (<30 days) adverse events. Postoperative anatomic results were graded by on-site neuroradiologists using the Modified Raymond Scale (Raymond 1=complete obliteration of aneurysm including the neck, Raymond 2=contrast filling the neck of the aneurysm without opacification of the aneurysm sac, Raymond 3=contrast filling the sac of the aneurysm). Predictors of good angiographic outcome were studied using chi-squared and t-tests. Results: A total of 571 patients with 571 aneurysms have been treated thus far in the study (196 ruptured, 375 unruptured). HydroSoft coils were successfully deployed in 549 (96.3%) of these patients. Adjunctive devices were used in 307 cases (53.8%) (212 balloon assistance, 89 stent). Aneurysmal occlusion rates were the following: 261 patients (47.3%) exhibited Raymond 1 occlusion, 257 patients (47.0%) had Raymond 2, and 29 patients (5.3%) had Raymond 3. Early post-operative stroke occurred in 10 patients (1.8%). Aneurysm perforation occurred in 11 patients (1.9%). Coil prolapse/migration occurred in 8 patients (1.4%). Early post-operative death occurred in 3 patients, all of whom presented with SAH (0.5%). Small aneurysm neck size was a significant predictor of good angiographic outcome (P=0.0003). Conclusions: Endovascular treatment of intracranial aneurysms with HydroSoft coils resulted in high rates of satisfactory occlusion (94.3%) and low rates of major clinical complications. Aneurysm neck size was a significant predictor of angiographic outcomes.
Letter: An International Investigation Into the COVID-19 Pandemic and Workforce Depletion in Highly Specialized Neurointerventional Units – Insights From Stroke Thrombectomy and Aneurysm Registry and Endovascular Neurosurgery Research Group
Alawieh, Ali , Kasab, Sami Al , Almallouhi, Eyad , Levitt, Michael R. , Jabbour, Pascal , Sweid, Ahmad , Starke, Robert M. , Wolfe, Stacey Q , Fragata, Isabel , Maier, Ilko , Matouk, Charles, Howard, Brian M. , Grossberg, Jonathan A , Cawley, M. F., Kan, Peter , Hafeez, Muhammad Ubaid , Singer, Justin, Crowley, R. Webster , Joshi, Krishna C. , Brinjikji, Waleed , Ogilvy, Christopher S. , Gomez‐Paz, Santiago , Veznedaroglu, Erol, Binning, Mandy J., Soomro, Jazba , Williamson, Richard , Chalhoub, Reda , Crosa, Roberto , Webb, Sharon, Psychogios, Marios, Ducruet, Andrew F. , Albuquerque, Felipe C. , Turner, Raymond, Casagrande, Walter, Leacy, Reade De , Fessler, Richard D., Osanai, Toshiya , Chowdhry, Shakeel , Schirmer, Clemens M. , Ringer, Andrew J. , Spiotta, Alejandro M , collaborators, STAR and ENRG, Savastano, Luis E., Gomez-Paz, Santiago , Crosa, Roberto , Levitt, Michael R , De Leacy, Reade , Schirmer, Clemens M , Almallouhi, Eyad , Hafeez, Muhammad U , Wolfe, Stacey Quintero , Fragata, Isabel , Howard, Brian M , Alawieh, Ali M , Ogilvy, Christopher S , Jabbour, Pascal , Saini, Vasu A , Fargen, Kyle M , Arthur, Adam Stephen , Goyal, Nitin , Cawley, Michael, Savastano, Luis , Levy, Elad I. , Waqas, Muhammad, Mokin, Maxim , Mascitelli, Justin R , Yoo, Albert J. , Grande, Andrew Walker , Psychogios, Marios‐Nikos , Majmundar, Neil J. , Al‐Mufti, Fawaz , Mocco, J , Park, Minhee , collaborators, STAR and ENRG

Mayo Clinic

Neurosurgery | August 24, 2020 | Volume: 87 | Issue: 6 | Pages: E697-E699

10.1093/neuros/nyaa415 | PMID 32893855 Get It

Ophthalmic artery catheterization for retinoblastoma treatment: does reflux affect tumor response?
Hammoud, Batoul , Weinberg, Joshua , Texakalidis, Pavlos , Xu, Vivian , Shivashankar, Kavya , Baldassari, Michael P. , Das, Somnath , Tjoumakaris, Stavropoula , Lezama, David A, Lim, Li‐Anne , Naamani, Kareem El , Ancona‐Lezama, David , Weinberg, Joshua H , Texakalidis, Pavlos , Jabbour, Pascal , ElNaamani, Kareem , Sweid, Ahmad , Shields, Carol L. , Dalvin, Lauren A. , Jabbour, Pascal

Mayo Clinic

Journal of NeuroInterventional Surgery | April 10, 2020 | Volume: 12 | Issue: 9 | Pages: 915-920

10.1136/neurintsurg-2019-015597 | PMID 32277036 Get It

Background Intra-arterial chemotherapy (IAC) for retinoblastoma (Rb) has been established as a primary treatment for the disease. To determine whether the presence of reflux into the ICA is associated with tumor response or with any other adverse events in pediatric retinoblastoma patients. Methods A retrospective chart review was performed for patients diagnosed with Rb and managed with ophthalmic artery catheterization (OAC). Results The total study cohort included 205 Rb tumors of 205 eyes in 194 consecutive patients who underwent 624 successful intra-arterial chemotherapy infusions using OAC. Of the 205 eyes, 65 eyes (32.7%) underwent 157 OAC procedures constituted group A (no reflux), 64 eyes (31.2%) underwent 236 OAC procedures constituted group B (variable pattern), and 74 eyes (36.1%) underwent 231 OAC procedures constituted group C (reflux). There was no significant difference in baseline characteristics between the three cohorts. Also, there was no significant difference in tumor characteristics between the three groups, except for genetic status. There was no significant difference between the three groups in terms of tumor response at completion of the treatment regimen. Complete tumor response was achieved at 70.2% in Group A, at 83.3% in Group B, and at 78.5% in group C (P=0.39). Similarly, eye enucleation occurred at 38.5% in group A, 31.8% in group B, and 31.5% in group C. None of the patients in both groups had any neurological adverse events or new onset of seizures. Conclusions The presence of reflux, which may complicate the procedure and prolong it, was not associated with poor outcomes in our analysis.