AbstractBackgroundCerebral Microbleeds (CMBs) are tracked in anti‐amyloid drug safety monitoring. T2*GRE or SWI MRI images are visually assessed for the presence of CMBs. Automated methods tuned for sensitivity often have unacceptably high false positive rates requiring extensive human cleanup.MethodAssume contemporaneous T2*GRE and T1‐weighted images. CMB detection (Figures 1,2) has three steps: 1) Segmentation outputs from the T1‐weighted image are resampled into the T2*GRE image voxel raster; 2) Normalized cross‐correlation of the T2*GRE with a CMB template identifies “candidate CMBs”; 3) a neural network using voxel patches centered on each candidate CMB rejects false positives. Patches presented to the network are 4D and include five contrasts drawn from the T2*GRE, correlation, T1‐weighted, WM probability and CSF probability images. The simple network architecture consists of convolutional blocks followed by dense blocks. The system is trained using images from ADNI, ARIC, MCSA, and the Mayo Clinic ADRC that have been previously visually graded for CMBs (Table in Figure 3). Importantly, we include participants with and without CMBs in our data reflecting the fact that the majority of people (even the elderly) have no CMBs. Data is split 70:10:20 by subject for training, validation, and testing. Various network configurations were evaluated.ResultHigh candidate detection sensitivity can be achieved at the expense of presenting hundreds to thousands of false positive candidates per input image to the rejection network. Our best performing network configuration to date has AUC 0.982 (95% bootstrap CI 0.971 to 0.990 based on the 10% validation subset). Choosing an operating point with 95% sensitivity in the validation set and admits, on average, 0.6 false positive CMB candidates per input T2*GRE image. Sensitivity is hindered by a small number of obvious errors in the ground truth visual assessment. Validation loss tracks training loss with no indication of over‐fitting. Example patches are shown in Figure 4.ConclusionExcessive false positive detection requires significant human correction and effort, preventing automated CMB detection from being widely adopted. We have an automated detection system that is sensitive (95%) and provides excellent false positive rejection (<1 false positive CMB/input image) reducing needed human effort.
Harmonizing machine learning imaging biomarkers – CDESH and the case for harmonization in both MR image and low‐dimensional (scalar) output space
AbstractBackgroundIn 2018 we presented the Computational DESH (CDESH) metric (DOI:10.1016/j.nicl.2018.11.015), a machine learning measure of abnormal CSF space patterns commonly observed on MRI in Disproportionately Enlarged Subarachnoid‐space Hydrocephalus (DESH‐type) NPH. We have shown that CDESH positive individuals often have discordant CSF and PET amyloid measures (DOI:10.1016/j.jalz.2019.06.4921). Positive CDESH scores are predictive of cognitive decline (DOI:10.1016/j.neuroimage.2021.117899, DOI: 10.1212/WNL.0000000000008616). The score is calculated from regional CSF volumes in a sulcal atlas and within the ventricles using a support vector machine (SVM). The Mayo Clinic Study of Aging (MCSA) changed scanner platforms (GE to Siemens) and T1‐weighted image resolution (1.2mm x 1.05mm x 1.05mm to 0.8mm isotropic) in 2017. We refer to these as “isotropic” or “anisotropic” scans. Our objective was to assess the dependence of a machine learning method (specifically CDESH) to image input variation and, if necessary, determine what needed corrections.MethodAll data considered is from the MCSA or Mayo Clinic ADRC. The SVM was trained on anisotropic images with laboriously labelled ground truth. We resampled the isotropic data from a crossover study (N=112, typically scanned same‐day with both platforms/resolutions) to match the anisotropic resolution. Two approaches to correction were evaluated (Figure 1). In Figure 2 we compare of the score with and without correction cross‐sectionally in 998 MCSA participants. In Figure 3 we present longitudinal series from 23 participants with multiple scans using the isotropic resolution protocol and at least one prior anisotropic image.ResultsComparisons of data from the crossover study are presented in Figure 1. Matching voxel resolution to the data used to train the SVM is critical and a subsequent mild linear score adjustment may be warranted. Cross‐sectional comparisons (Figure 2) confirm improvement matching voxel resolution with a possible mild linear score adjustment. After matching voxel resolution CDESH score trajectories (Figure 3) are markedly more stable across this scanner/protocol change.ConclusionThe SVM‐based CDESH score is sensitive to voxel resolution. Corrections are needed in image processing and possibly in the scalar output score to achieve stability across protocol and scanner changes. The resulting correction supports coherent long timeseries data and longitudinal extension of previous work.
Genetic contribution to grey matter network disruptions and Alzheimer disease cerebrospinal fluid markers
AbstractBackgroundGrey matter covariance networks become disrupted early in Alzheimer’s disease (AD), when amyloid starts aggregating, and before the onset of irreversible atrophy. However, the precise relationship of grey matter network breakdown and the AD pathophysiological process remains unclear. Here, we studied to what extent shared familial (genes and family environment) or environmental factors unique to a twin contribute to these relationships in a sample of older monozygotic twins with intact cognition.MethodFrom the EMIF‐AD PreclinAD study we included monozygotic twins who had at least an MRI scan (n=197) and CSF available (n=124). We assessed the upper limit of genetic contribution to grey matter network measures (size, degree, connectivity density, clustering, path length, small‐world measures) with within‐twin pair correlations. Associations between CSF AD markers (Aβ42/40, t‐tau, p‐tau) and other markers related to AD pathophysiology (neurogranin, Aβ38, Aβ40, BACE1) with grey matter network disruptions were assessed with linear mixed models. Twin analyses (cross‐twin cross‐trait, twin difference analyses) were used to assess the contribution of shared familial and/or unique environmental factors to these associations.ResultTwenty individuals (16%) had abnormal CSF Aβ42/40 levels. Grey matter network measures were highly correlated within twin pairs (r=0.54‐0.97; all p<0.001, Fig.1), suggesting a moderate to strong genetic background. Across the whole sample, more abnormal Aβ42/40 ratios were moderately related to lower connectivity density (β±SE = 0.176±0.09, p=0.055, Fig.2). The strongest associations with grey matter network measures were observed for t‐tau and p‐tau levels (range β=‐0.344‐0.182), followed by Aβ production markers (Aβ38, Aβ40, BACE1) (range β=‐0.202‐0.165). We observed no relationships between neurogranin and grey matter network measures. Cross‐twin cross‐trait analyses showed that levels for t‐tau, p‐tau and Aβ38 in one twin were associated with grey matter network measures in their co‐twin (r=‐0.27 to ‐0.21; p range=0.02 to 0.07, Fig.3). Within‐pair differences in BACE1 were related to within‐pair differences in normalized path length values (r=0.35; p=0.01; Fig.4).ConclusionOur results suggest a shared familial background for the relationship of grey matter network disruptions and AD‐related processes as measured in CSF. In addition, unique environmental factors influencing BACE1 may also affect grey matter network disruptions.
Choice of Inversion Time for Arterial Spin Labeling MRI in the U.S. POINTER Lifestyle Intervention Trial
AbstractBackgroundThe U.S. Study to Protect Brain Health Through Lifestyle Intervention to Reduce Risk (U.S. POINTER) is a 2‐year randomized controlled trial to evaluate the effect of lifestyle interventions in older adults (60‐79 years). The POINTER Imaging ancillary study is collecting Arterial Spin Labeling (ASL) MRI data to map cerebral blood flow (CBF) and evaluate the effect of interventions in the perfusion imaging biomarker. The optimization of timing parameters is essential for robust and efficient acquisition of ASL MRI.MethodA subset (n=83; F/M=51/32; age=69.0±5.5) of POINTER Imaging participants at two imaging sites underwent two ASL MRI scans during the same baseline session. Two 3D Pulsed ASL were obtained with TI1 of 790ms and TI2 values of 2000ms or 2750ms, which provide the delay times (between labeling and imaging) of 1210ms or 1960ms. ASL images were quantified into a physiological unit of CBF, ml/100g/min, using a single compartment kinetic model. CBF maps from two scans were normalized into a standard space and a voxel‐wise paired t‐test was performed after site variations were harmonized and covariates (age and sex) were adjusted. The age and sex effects in the difference of CBF values between two scans were also examined using linear regression. To control false positives, clusters smaller than 41ml were removed based on a simulation with α=0.05.ResultThe CBF values in ASL MRI rely on the timing of image acquisition: only a fraction of label bolus arrives in the tissue with a short delay while images suffer from low signal due to the magnetization decay with a long delay. Figure 1 shows the regions that require a long delay time (red) or a short delay (blue). The difference in CBF is proportional to arterial transit time (ATT) and the analysis shows females have shorter ATT mainly in the peri‐Sylvian region (Figure 2). No cluster survived correction in the analysis of the aging effect.ConclusionThe acquisition of two CBF maps not only offers optimization of acquisition timing but provides an additional perfusion parameter, arterial transit time, which may be a potential biomarker of cerebrovascular pathophysiology.
Latent space projection of brain FDG‐PET creates a powerful classifier for neurodegenerative diseases
AbstractBackgroundFluorodeoxyglucose positron emission tomography (FDG‐PET) is an established modality for differential diagnosis of dementia. Deriving phenotypic signatures from FDG‐PET via machine learning is challenging due to the high dimensional nature of brain images relative to the generally small number of labeled examples available for training, the class imbalance among those labels, and the cooccurrence of multiple pathologies. In this study, we developed a multi‐class, multi‐label framework to address these challenges.MethodA database of clinically acquired PET/CT images from 3,000 unique patients was used to develop a latent space model using matrix decomposition. This model was then applied to images from a separate cohort of Mayo Clinic Alzheimer’s Disease Research Center participants (n=1,745) labeled as cognitively unimpaired (CU) (n=1,436) or with the following potentially co‐occurring phenotypes: Alzheimer’s disease (AD) (n=165), Lewy body dementia (DLB) (n=92), behavioral variant frontotemporal dementia (bvFTD) (n=43), semantic (svPPA) (n=10) and logopenic (lvPPA) (n=13) variant PPA, and posterior cortical atrophy (PCA) (n=17). A k‐nearest neighbors classifier that is robust to these imbalanced and overlapping labels was then trained on these examples. The resulting classifier was evaluated by area under receiver‐operator characteristic curve (ROC‐AUC) via leave one out cross validation, using clinical diagnosis as the gold standard.ResultROC curves and AUC scores for each phenotype are illustrated in Fig. 1a. Because the classifier is based on a k‐nearest neighbors connectivity matrix, it has a convenient graphical representation, where images are nodes and edges are drawn between an image and its set of nearest neighbors in latent space. A self‐organizing force directed graph constructed in this way is illustrated in Fig 1b, highlighting the strong separation of CU and degenerative images, as well as the segregation of each phenotype within the neurodegenerative region of the graph.ConclusionIn this study, we developed a machine learning framework for classification of neurodegenerative disease based on k‐nearest neighbor analysis in a low dimensional latent space projection of FDG‐PET images. By leveraging low‐dimensional representations and k‐nearest neighbors analysis, this framework is robust in multi‐class, multi‐label tasks with strong class imbalance and provides a highly interpretable graphical representation.
A standardized protocol for detection of Amyloid Related Imaging Abnormality (ARIA) on 3T Philips Magnetic Resonance Imaging (MRI)
AbstractBackgroundARIA is a common side effect of aducanumab, the first anti‐amyloid pharmacotherapy approved by the US Food and Drug Administration (FDA) to treat Alzheimer’s disease. Regular MRI is required by FDA to detect and monitor different forms of ARIA during initiation of therapy. MRI protocols must be a) high resolution to detect abnormalities with high sensitivity, b) fast to accommodate workflow and ensure patient compliance and c) standardized to maximize data acquisition consistency across sites. Based on a vendor agnostic protocol recommendation by Benzinger et al (CTAD 2021), we propose specific parameters for 3T Philips systems, for an accelerated and enhanced protocol.MethodThe protocol was developed on a 3T Philips Elition X scanner, using 32‐channel head coil, and included 3D T1, 3D FLAIR, 2D DWI, 2D T2* and multi echo 3D Susceptibility Weighted Imaging (SWI) sequences.ResultAcquisition voxel resolution of 3D T1, 3D FLAIR, T2* and DWI matches current recommendations. 3D SWI resolution is 0.7x0.7x2mm. Compressed‐SENSE (C‐SENSE) acceleration is applied on 3D T1, 3D FLAIR, T2* and 3D SWI. SENSE is applied on DWI (Figure 1). Total acquisition time including the additional 3D SWI scan is 11 minutes, 6 minutes faster than the original recommendation. Qualitative assessment of images showed high signal‐to‐noise and contrast‐to‐noise. Images were free of acceleration related artifacts. Automated slice prescription localizer ensures better reproducibility for longitudinal assessment.ConclusionImaging protocol standardization is necessary to ensure consistent accuracy for diagnosing ARIA. Broad recommendations leave room for variability, therefore specific parameters are needed to achieve cross‐platform standardization. Our protocol is applicable for 3T Philips systems with compressed‐SENSE capability and 32‐channel head coil. The recommended C‐SENSE values maintain image quality with shorter exam time. This is more comfortable for patients and easier to fit into the workflow. The higher sensitivity of SWI can improve thresholds for therapy monitoring and provide additional quantitative measurements.
Regional white matter hyperintensities in posterior cortical atrophy and logopenic progressive aphasia
AbstractBackgroundWhite matter hyperintensities (WMH) are markers of cerebral small vessel disease and have been associated with higher risk of typical amnestic Alzheimer’s disease (AD), however, little is known about the role of WMHs in atypical variants of AD. This study aimed to determine the frequency and distribution of WMH in two atypical variants of AD: logopenic progressive aphasia (LPA) and posterior cortical atrophy (PCA), and determine whether WMH are associated with demographic and clinical outcomes in these cohorts.MethodSeventy‐five LPA and 39 PCA patients were recruited by the Neurodegenerative Research Group and underwent two‐ dimensional fluid‐attenuated inversion recovery (FLAIR) MRI and Pittsburgh Compound B (PiB) PET. All patients were PiB‐positive. All FLAIR images were segmented using an in‐house software, then were manually edited by a trained imaging analyst. WMH volume was scaled by total intracranial volume to correct for differences in head size. Adjusted WMH burdens were compared between LPA and PCA, and associations were assessed between WMH burden and age, global PiB standard uptake value ratios (SUVRs), and clinical metrics, including tests of general cognitive impairment, executive function, naming, repetition, visuospatial and visuoperceptual function, and parkinsonism. Associations between WMHs and clinical scores were adjusted for age and brain volume to correct for atrophy.ResultTotal WMH burden was similar in PCA and LPA, however, regional differences were identified with PCA having greater subcortical WMH burden in right occipital, parietal, and temporal lobes compared to LPA, and LPA having greater WMH burden in left deep grey and white matter and greater subcortical burden in left parietal lobe compared to PCA. Total WMH burden was greater with older age in both groups but was not related to global PiB SUVR either globally or locally. Greater total WMH was associated with visuoperceptual performance in both cohorts after correcting for atrophy. When assessed regionally, visuoperceptual performance was associated with right subcortical occipital WMH across the cohort.ConclusionRegional distribution of WMHs differ across clinical variants of atypical AD and WMHs may impact clinical outcomes, although further work is needed to determine whether they reflect cerebrovascular disease or regionally specific neurodegenerative changes.
Which NODDI implementation is nicest for diffusion MRI?
AbstractBackgroundNeurite Orientation Dispersion and Density Imaging (NODDI) is becoming increasingly common as multiband acceleration becomes available for clinical scanning, but fitting the model can be extremely slow. Since the release of the original MATLAB implementation in 2012, three alternatives have become popular: Accelerated Microstructure Imaging via Convex Optimization (AMICO), the Microstructure Diffusion Toolbox (MDT), and the CUDA Diffusion Modelling Toolbox (cuDIMOT). They accelerate fitting through reformulation and/or using GPUs, but the implementation differences raise the question of which approach is best. To our knowledge all previous comparisons lacked knowledge of the true values and used the original implementation as the nominally correct one, with in vivo data. We remedy that using simulations with known NODDI values, in addition to in vivo scans.MethodWe created a software phantom with Neurite Density Index (NDI) values linearly increasing from 0.1 to 1.0 in x, Orientation Dispersion (ODI) from 0 to 1 in y, and Isotropic water Volume Fraction (ISOVF) from 0 to 0.9 in z. We simulated five scans using the ADNI3 advanced diffusion MRI protocol. The phantom had 20 voxels in each direction, and the fiber bundle principal direction randomly varied between the simulations. The simulations were fit by the original, AMICO, MDT, and cuDIMOT implementations, and root mean square errors were calculated as shown in Table 1. A discrepancy measure was also calculated using the brain voxels of three in vivo human scans acquired using the same protocol on a Siemens Prisma, substituting the original implementation’s values for the truth since the latter is unknown for in vivo scans.ResultcuDIMOT had the least error (for ODI < 0.8) and was fastest. The original implementation was a close second in accuracy but much slower. cuDIMOT’s ODI underestimation can be corrected with a transfer function in the noise‐free case, but that approach fails with actual scans.ConclusionThe original or cuDIMOT implementations should be used, with cuDIMOT the favorite when at least one CUDA‐capable GPU is available and the number of scans are large. Correcting cuDIMOT’s ODI underestimation using a different initialization or form of Dawson’s integral should be investigated.
Comparison of amyloid accumulation between Down syndrome and autosomal‐dominant Alzheimer disease
AbstractBackgroundGiven the triplication of chromosome 21 and the location of the amyloid precursor protein gene on chromosome 21, almost all adults with Down syndrome (DS) develop Alzheimer disease (AD)‐like pathology and dementia during their lifetime. Comparing amyloid accumulation in DS to autosomal dominant AD (ADAD), another genetic form of AD, may improve our understanding of early AD pathology development.MethodWe assessed amyloid positron emission tomography (PET) imaging in 192 participants with DS and 33 sibling controls from the Alzheimer’s Biomarker Consortium‐Down Syndrome (ABC‐DS) and 265 mutation‐carriers (MC) and 169 familial controls from the Dominantly Inherited Alzheimer Network (DIAN) (Table 1). We calculated regional standard uptake value ratios (SUVR) using a cerebellar cortex reference region and converted global amyloid burden SUVR to centiloids. We compared amyloid PET by cognitive status and estimated‐years‐to‐symptom‐onset (EYO). EYO was calculated for DIAN participants by subtracting their age from parental age of symptom onset and for ABC‐DS participants by subtracting their age from 50.2 years, a published average age of symptom onset in a large sample of individuals with DS (Fortea et al., 2020). In a subset of participants, we assessed the relationship between amyloid PET and CSF Aβ42/40.ResultThe relationship between CSF Aβ42/40 and amyloid PET was similar in DS and MC participants (Figure 1). We did not observe significant differences between MC and DS grouped by cognitive status (Figure 2). However, when assessed over EYO, global amyloid burden was significantly elevated in MC at EYO ≥ ‐23 but was not elevated in DS until EYO ≥ ‐15 (Figure 3). We observed early cortical and subcortical amyloid PET increases in both groups, but we also measured some regional differences in amyloid PET changes between MC and DS, specifically in the medial occipital region (Figure 4 and 5).ConclusionThese results demonstrate similarities in the relationship between amyloid biomarkers and the levels of amyloid accumulation in ADAD and DS. However, we also observed a 5‐10 year delay and some regional differences in amyloid accumulation in DS. This is important for future clinical trials to consider when recruiting participants and determining treatment efficacy.
Potential for Re‐Identifying Brain PET Research Participants using Face Recognition
AbstractBackgroundStudies of aging and dementia often acquire brain MRI and PET images, then de‐identify and share these widely with other researchers. It is known that research participants can potentially be re‐identified from brain MRI and CT using face recognition, but this has not been tested with PET imaging.MethodWe generated face reconstruction images of 182 volunteers using their existing amyloid (PiB), tau (FTP), and FDG PET scans from clinical GE PET/CT scanners, and we measured how often commercial automatic face recognition (Microsoft Azure) correctly matched these reconstructions with photographs of their faces. We additionally compared these match rates with face reconstructions from CT (from PET/CT) and MRI. When testing face recognition from PET scans, CT was used only during PET reconstruction, not for face recognition. We also validated our updated mri_reface software, originally developed to de‐identify (“de‐face”) faces in MRI, with new support for PET images. We measured face recognition rates before and after applying mri_reface to PET, CT, and MRI. In addition, we measured effects of de‐facing on biomarker measurements (global and regional SUVR) using 244 ADNI Florbetapir (FBP) amyloid PET scans with two automated pipelines: FreeSurfer 6.0 (PETSurfer) and an in‐house SPM12‐based pipeline.ResultRates of successful face recognition with PET ranged from 32‐41% (Table 1) across tracers. These were lower than MRI (98%) and CT (78%) but still concerning for participant privacy. Using mri_reface reduced face recognition to 0‐3.5% for PET, 5% for CT, and 8% for MRI. mri_reface had little effect on global amyloid SUVR measurements from ADNI PET images (Figure 1). ICC values between original and de‐faced images were 1.00 with biases and median absolute differences < 0.5%, across both pipelines. Effects on individual regions all had ICC values > 0.98 with biases and median absolute differences < 2%.ConclusionFace reconstructions from PET images have sufficient quality for potential re‐identification using publicly available face recognition technology. Research studies should consider using face de‐identification (de‐facing) software on PET images in addition to CT and structural MRI. Our free, automatic mri_reface software greatly reduced the potential for face recognition without substantially affecting SUVR measurements.