AbstractBackgroundReduced striatal uptake on ioflupane SPECT is considered an indicative biomarker for Dementia with Lewy Bodies (DLB), and has been proposed as an indicative biomarker for Mild Cognitive Impairment with Lewy Bodies (MCI‐LB). Little data exists on the profile of uptake on key striatal regions of interest (ROIs) in DLB or MCI‐LB.MethodParticipants with DLB or MCI‐LB at baseline based on the presence of ≥2 core clinical DLB features, and ≥2 ioflupane SPECT scans performed approximately annually, were identified from the Mayo ADRC database. Minimum brain laterality z‐score values for the putamen (whole, anterior and posterior), caudate and striatum were determined using DaTQUANT 2 software. Baseline clinical and scan data was used for all analyses, and the annualized minimum putamen z‐change was determined on serial scans. The scan was considered abnormal if the minimum putamen z‐score was <‐0.98 based on clinicopathologic data.Result27 participants were included (21 DLB and 6 MCI‐LB, 96% male). Compared to MCI‐LB, DLB had a lower mean MoCA score and a trend toward a higher UPDRS score compared to MCI‐LB; there were no statistically significant differences in age, sex, onset age or duration of cognitive decline, or presence of other core DLB features. The majority (89%) had an abnormal scan at baseline. All ROI z‐scores showed the expected general trend of DLB<MCI‐LB, and the annualized z‐change was more negative in DLB, but none of the findings reached statistical significance.ConclusionThese findings suggest in MCI‐LB and DLB that 1) an abnormal ioflupane SPECT scan is frequently present at diagnosis, 2) z‐scores become more negative over time, and 3) the annualized z‐change is similar. Similar findings in larger cohorts would support the use of ioflupane SPECT as a biomarker in both MCI‐LB and DLB clinical trials.
Latent space projection of brain FDG‐PET creates a powerful classifier for neurodegenerative diseases
AbstractBackgroundFluorodeoxyglucose positron emission tomography (FDG‐PET) is an established modality for differential diagnosis of dementia. Deriving phenotypic signatures from FDG‐PET via machine learning is challenging due to the high dimensional nature of brain images relative to the generally small number of labeled examples available for training, the class imbalance among those labels, and the cooccurrence of multiple pathologies. In this study, we developed a multi‐class, multi‐label framework to address these challenges.MethodA database of clinically acquired PET/CT images from 3,000 unique patients was used to develop a latent space model using matrix decomposition. This model was then applied to images from a separate cohort of Mayo Clinic Alzheimer’s Disease Research Center participants (n=1,745) labeled as cognitively unimpaired (CU) (n=1,436) or with the following potentially co‐occurring phenotypes: Alzheimer’s disease (AD) (n=165), Lewy body dementia (DLB) (n=92), behavioral variant frontotemporal dementia (bvFTD) (n=43), semantic (svPPA) (n=10) and logopenic (lvPPA) (n=13) variant PPA, and posterior cortical atrophy (PCA) (n=17). A k‐nearest neighbors classifier that is robust to these imbalanced and overlapping labels was then trained on these examples. The resulting classifier was evaluated by area under receiver‐operator characteristic curve (ROC‐AUC) via leave one out cross validation, using clinical diagnosis as the gold standard.ResultROC curves and AUC scores for each phenotype are illustrated in Fig. 1a. Because the classifier is based on a k‐nearest neighbors connectivity matrix, it has a convenient graphical representation, where images are nodes and edges are drawn between an image and its set of nearest neighbors in latent space. A self‐organizing force directed graph constructed in this way is illustrated in Fig 1b, highlighting the strong separation of CU and degenerative images, as well as the segregation of each phenotype within the neurodegenerative region of the graph.ConclusionIn this study, we developed a machine learning framework for classification of neurodegenerative disease based on k‐nearest neighbor analysis in a low dimensional latent space projection of FDG‐PET images. By leveraging low‐dimensional representations and k‐nearest neighbors analysis, this framework is robust in multi‐class, multi‐label tasks with strong class imbalance and provides a highly interpretable graphical representation.
Which NODDI implementation is nicest for diffusion MRI?
AbstractBackgroundNeurite Orientation Dispersion and Density Imaging (NODDI) is becoming increasingly common as multiband acceleration becomes available for clinical scanning, but fitting the model can be extremely slow. Since the release of the original MATLAB implementation in 2012, three alternatives have become popular: Accelerated Microstructure Imaging via Convex Optimization (AMICO), the Microstructure Diffusion Toolbox (MDT), and the CUDA Diffusion Modelling Toolbox (cuDIMOT). They accelerate fitting through reformulation and/or using GPUs, but the implementation differences raise the question of which approach is best. To our knowledge all previous comparisons lacked knowledge of the true values and used the original implementation as the nominally correct one, with in vivo data. We remedy that using simulations with known NODDI values, in addition to in vivo scans.MethodWe created a software phantom with Neurite Density Index (NDI) values linearly increasing from 0.1 to 1.0 in x, Orientation Dispersion (ODI) from 0 to 1 in y, and Isotropic water Volume Fraction (ISOVF) from 0 to 0.9 in z. We simulated five scans using the ADNI3 advanced diffusion MRI protocol. The phantom had 20 voxels in each direction, and the fiber bundle principal direction randomly varied between the simulations. The simulations were fit by the original, AMICO, MDT, and cuDIMOT implementations, and root mean square errors were calculated as shown in Table 1. A discrepancy measure was also calculated using the brain voxels of three in vivo human scans acquired using the same protocol on a Siemens Prisma, substituting the original implementation’s values for the truth since the latter is unknown for in vivo scans.ResultcuDIMOT had the least error (for ODI < 0.8) and was fastest. The original implementation was a close second in accuracy but much slower. cuDIMOT’s ODI underestimation can be corrected with a transfer function in the noise‐free case, but that approach fails with actual scans.ConclusionThe original or cuDIMOT implementations should be used, with cuDIMOT the favorite when at least one CUDA‐capable GPU is available and the number of scans are large. Correcting cuDIMOT’s ODI underestimation using a different initialization or form of Dawson’s integral should be investigated.
A standardized protocol for detection of Amyloid Related Imaging Abnormality (ARIA) on 3T Philips Magnetic Resonance Imaging (MRI)
AbstractBackgroundARIA is a common side effect of aducanumab, the first anti‐amyloid pharmacotherapy approved by the US Food and Drug Administration (FDA) to treat Alzheimer’s disease. Regular MRI is required by FDA to detect and monitor different forms of ARIA during initiation of therapy. MRI protocols must be a) high resolution to detect abnormalities with high sensitivity, b) fast to accommodate workflow and ensure patient compliance and c) standardized to maximize data acquisition consistency across sites. Based on a vendor agnostic protocol recommendation by Benzinger et al (CTAD 2021), we propose specific parameters for 3T Philips systems, for an accelerated and enhanced protocol.MethodThe protocol was developed on a 3T Philips Elition X scanner, using 32‐channel head coil, and included 3D T1, 3D FLAIR, 2D DWI, 2D T2* and multi echo 3D Susceptibility Weighted Imaging (SWI) sequences.ResultAcquisition voxel resolution of 3D T1, 3D FLAIR, T2* and DWI matches current recommendations. 3D SWI resolution is 0.7x0.7x2mm. Compressed‐SENSE (C‐SENSE) acceleration is applied on 3D T1, 3D FLAIR, T2* and 3D SWI. SENSE is applied on DWI (Figure 1). Total acquisition time including the additional 3D SWI scan is 11 minutes, 6 minutes faster than the original recommendation. Qualitative assessment of images showed high signal‐to‐noise and contrast‐to‐noise. Images were free of acceleration related artifacts. Automated slice prescription localizer ensures better reproducibility for longitudinal assessment.ConclusionImaging protocol standardization is necessary to ensure consistent accuracy for diagnosing ARIA. Broad recommendations leave room for variability, therefore specific parameters are needed to achieve cross‐platform standardization. Our protocol is applicable for 3T Philips systems with compressed‐SENSE capability and 32‐channel head coil. The recommended C‐SENSE values maintain image quality with shorter exam time. This is more comfortable for patients and easier to fit into the workflow. The higher sensitivity of SWI can improve thresholds for therapy monitoring and provide additional quantitative measurements.
The Neurofilament Surveillance Project (NSP): A biomarker study to sample blood quarterly in familial frontotemporal lobar degeneration
AbstractBackgroundIn familial frontotemporal lobar degeneration (f‐FTLD), plasma levels of neurofilament light (NfL) are elevated at least two years prior to symptom onset and predict future clinical status. The Neurofilament Surveillance Project (NSP), an actively recruiting observational study, seeks to obtain higher resolution data of temporal changes in plasma NfL to better understand its clinical utility in f‐FTLD interventional trials. The NSP is a pre‐competitive collaboration sponsored by the Bluefield Project to Cure FTD and funded by biotechnology and pharmaceutical companies and nonprofit organizations.MethodParticipants must be members of families with disease‐causing mutations in C9orf72, MAPT or GRN and enrolled in the ALLFTD natural history study. Up to 335 participants, with roughly equal representation across mutation type, provide plasma quarterly for 3 years (4355 samples total) to enable the observation of peripheral NfL levels longitudinally during disease onset and progression. Plasma is collected by certified mobile research nurses during remote visits, and NfL is measured in batch at least every 6 months. NfL measurements from one plasma aliquot per draw will be correlated with annual assessments obtained in the ALLFTD study, including measures of disease severity (CDRÒ+NACC‐FTLD, CGI, etc.), cognitive function from the UDS Neuropsychology Battery, and volumetric MRI data. Additional plasma aliquots are reserved for future analyses of other biomarkers during the course of the study; another subset of aliquots is reserved to share with interested investigators after the study ends.ResultAs of 1/19/22, the NSP had enrolled 161 participants, including 62 from C9orf72 kindreds, 60 from MAPT kindreds, and 28 from GRN kindreds. One‐hundred forty‐five participants had completed their initial visit, and 109 had completed more than 3, and up to 5, quarterly blood draws. Enrollment and study visits are ongoing despite COVID‐related limitations.ConclusionThe quarterly blood sampling from this study, combined with annual comprehensive clinical assessments through the ALLFTD natural history study, will enable a more detailed understanding of when and how NfL levels change during phenoconversion and/or disease progression in f‐FTLD mutation carriers. These data will be especially informative in the context of the targeted investigational therapeutics for f‐FTLD now entering clinical trials.
Event‐related‐potentials are sensitive and reliable EEG biomarkers for mild cognitive impairment: A longitudinal study
AbstractBackgroundEvent‐related‐potentials (ERPs) during cognitive tasks are sensitive measures of cognitive decline [1]‐[2] and could quantitatively measure the trajectory of disease progression or response to clinical interventions. In this longitudinal study, we aimed to compare ERPs between individuals with mild cognitive impairment (MCI) and controls, and to demonstrate the test‐retest reliability of ERP measures to assess their potential utility for future observational studies and treatment trials.MethodsParticipants included individuals with mild cognitive impairment (MCI, n=31) and healthy controls stratified by age: HC2 (n=46, 40‐60 yrs.), HC3 (n=56, 60‐90 yrs.). ERPs during attention, image recognition, and verbal memory tasks were recorded using a wireless EEG to determine amplitudes and latencies of the P200 and late positive potential (LPP) ERP components in response to target (memorized) and non‐target (novel) stimuli. Differences between MCI and HC3 groups were characterized at the initial visit, and longitudinal changes in ERP components were determined at 1‐year follow‐up for both groups. Reliability of ERP measures was demonstrated by computing intraclass correlation coefficient (ICC) measures of test‐retest variability in all healthy controls (HC2 and HC3) from initial visit to 1‐year follow‐up.ResultsAt the initial visit, the MCI group demonstrated reduced LPP amplitude (Hedges‐g=0.8, p=10‐3) and delayed P200‐latency (Hedges‐g=0.89, p=10‐4) when compared to HC3. Reliability in healthy controls was high for LPP (0.85 and 0.75 for target and non‐target stimuli, respectively) and moderate for P200‐latency (0.67 and 0.53 for target and non‐target stimuli, respectively), without longitudinal changes after 1‐year follow‐up. Individuals with MCI demonstrated increased P200‐latency (Hedges‐g= 1.05, p=0.02, df=8).ConclusionsIndividuals with MCI demonstrated quantifiable memory ERP deficits at baseline with detectable change in the P200 component at 1‐year follow‐up, demonstrating that ERPs are sensitive measures for quantifying mild cognitive impairment. Test‐retest reliability of these measures was good or moderate after 1‐year, supporting their feasibility for longitudinal monitoring of patients during disease progression or quantifying the cognitive impact of potential interventions.
Harmonizing machine learning imaging biomarkers – CDESH and the case for harmonization in both MR image and low‐dimensional (scalar) output space
AbstractBackgroundIn 2018 we presented the Computational DESH (CDESH) metric (DOI:10.1016/j.nicl.2018.11.015), a machine learning measure of abnormal CSF space patterns commonly observed on MRI in Disproportionately Enlarged Subarachnoid‐space Hydrocephalus (DESH‐type) NPH. We have shown that CDESH positive individuals often have discordant CSF and PET amyloid measures (DOI:10.1016/j.jalz.2019.06.4921). Positive CDESH scores are predictive of cognitive decline (DOI:10.1016/j.neuroimage.2021.117899, DOI: 10.1212/WNL.0000000000008616). The score is calculated from regional CSF volumes in a sulcal atlas and within the ventricles using a support vector machine (SVM). The Mayo Clinic Study of Aging (MCSA) changed scanner platforms (GE to Siemens) and T1‐weighted image resolution (1.2mm x 1.05mm x 1.05mm to 0.8mm isotropic) in 2017. We refer to these as “isotropic” or “anisotropic” scans. Our objective was to assess the dependence of a machine learning method (specifically CDESH) to image input variation and, if necessary, determine what needed corrections.MethodAll data considered is from the MCSA or Mayo Clinic ADRC. The SVM was trained on anisotropic images with laboriously labelled ground truth. We resampled the isotropic data from a crossover study (N=112, typically scanned same‐day with both platforms/resolutions) to match the anisotropic resolution. Two approaches to correction were evaluated (Figure 1). In Figure 2 we compare of the score with and without correction cross‐sectionally in 998 MCSA participants. In Figure 3 we present longitudinal series from 23 participants with multiple scans using the isotropic resolution protocol and at least one prior anisotropic image.ResultsComparisons of data from the crossover study are presented in Figure 1. Matching voxel resolution to the data used to train the SVM is critical and a subsequent mild linear score adjustment may be warranted. Cross‐sectional comparisons (Figure 2) confirm improvement matching voxel resolution with a possible mild linear score adjustment. After matching voxel resolution CDESH score trajectories (Figure 3) are markedly more stable across this scanner/protocol change.ConclusionThe SVM‐based CDESH score is sensitive to voxel resolution. Corrections are needed in image processing and possibly in the scalar output score to achieve stability across protocol and scanner changes. The resulting correction supports coherent long timeseries data and longitudinal extension of previous work.
Analytical Validation of the Quanterix Neurofilament Light Chain (NfL) Advantage Assay in Plasma
AbstractBackgroundNeurofilament light chain (NfL) is an emerging blood‐based biomarker useful for assessing neuro‐axonal injury in several neurological conditions. Plasma NfL concentrations reflect the extent of axonal damage, making it a general marker of neurodegenerative disease progression. This study evaluates the analytical performance characteristics of the Quanterix NfL Advantage method in EDTA‐plasma.MethodThe assay was performed per manufacturer’s instructions on the Quanterix Simoa HD‐X Analyzer. Analytical validation included analyte stability, imprecision, lower limit of quantification (LLOQ), analytical measurement range (AMR), accuracy, and interferences. One‐sided reference intervals were established using quantile regression methods among 1100 cognitive normal individuals, age 20 to 95 years without known chronic kidney disease, stroke, or myocardial infarction.ResultNfL was stable in plasma three days ambient, seven days refrigerate, 90 days frozen (‐20C), and over 3 freeze/thaw cycles. Intra and inter‐assay imprecision, expressed as % coefficient of variation (%CV), ranged from 3.4 – 6.0% and 5.9 – 11.6% respectively. The LLOQ was evaluated using patient plasma pools at concentrations of 1.7 and 3.6 pg/mL. %CVs were 16.8% and 9.7% respectively, and the LLOQ was set at 3.0 pg/mL. Accuracy was assessed by spiking 5 plasma samples with NfL calibratoran 87% average recovery (range 81‐94%) was observed. The AMR of 3.0 – 1500 pg/mL was verified with a regression slope of 0.93 and r2 > 0.99. Additionally, plasma admixtures covering the AMR showed acceptable linear response (slope of 1.02 and r² >0.99). The assay was not affected by icterus to 100 mg/dL, lipemia to 1000 mg/dL, hemolysis to 1000 mg/dL at NfL concentrations >30 pg/mL or to 200 mg/dL at NfL concentrations ≤30 pg/mL. NfL increased with age but did not differ by sex. The data supported age‐based reference intervals broken down into 10‐year intervals. The 97.5th percentile limits were: 20s: ≤8.4 pg/mL, 30s: ≤11.4 pg/mL, 40s: ≤15.4 pg/mL, 50s: ≤20.8 pg/mL, 60s: ≤28.0 pg/mL, 70s: ≤37.9 pg/mL, 80+: ≤51.2 pg/mL.ConclusionThe analytical performance characteristics of the plasma Quanterix NfL advantage assay were deemed acceptable for clinical laboratory implementation. The establishment of NfL reference intervals will aid in the clinical interpretation of patient plasma NfL concentrations.
Comparing cerebrovascular disease diffusion MRI markers using post‐mortem and longitudinal imaging data
AbstractBackgroundDiffusion MRI (dMRI) based quantification of microstructural changes in white matter (WM) are increasingly proposed to measure cerebrovascular disease (CVD) related changes. Our objective was to compare the proposed dMRI markers using postmortem neuropathologic CVD data and then evaluate the predictors of longitudinal dMRI markers using serial scans.MethodWe identified n=51 participants (mean age: 83.8 years, 63% males) with ante‐mortem dMRI and postmortem CVD evaluation and n=718 participants (mean age: 71.1 years, 56% males) with at least two dMRI scans from the population‐based sample of Mayo Clinic Study of Aging. We computed dMRI measures proposed for measuring CVD: Free Water (FW), Fractional Anisotropy (FA) adjusted for FW (FAadj), Peak width Skeletonized Mean Diffusivity (PSMD), and FA of the genu of corpus callosum (Genu‐FA). We used the FW and PSMD (PSMD release 1.8.1) kits from the MarkVCID consortium.Using weighted linear regression models with adjustments for MRI scan time to death, we evaluated associations between the baseline dMRI and two pathology CVD scores: Strozyk (represents the presence and number of macroscopic lesions) and Kalaria (represents the summary score of vessel wall modifications) scales. We ran linear mixed effect models with all available serial dMRI measures as outcomes and vascular risk (measured by the number of cardiovascular and metabolic conditions‐CMC), baseline imaging measures (amyloid and white matter hyperintensities (WMH)) and their interaction with time as key predictors.ResultMost dMRI markers were predictors of postmortem CVD pathology (Table 1). In longitudinal dMRI models, terms associated with amyloid explained little variability in dMRI (<1%) (Table 2). WMH was a significant predictor of baseline and decline in dMRI measures with WMH explaining a considerable percentage of variability in FW (34%) and PSMD (28%). Vascular risk measures were significant predictors of three out of the four dMRI measures.ConclusionThe diffusion measures proposed as surrogate markers of CVD map reasonably well to CVD pathological scales and do not change substantially as a function of baseline amyloidosis. Our findings shed light on variability in the proposed diffusion markers using postmortem data and longitudinal imaging data. Further work is needed to evaluate their clinical utility.
AbstractBackgroundCerebral Microbleeds (CMBs) are tracked in anti‐amyloid drug safety monitoring. T2*GRE or SWI MRI images are visually assessed for the presence of CMBs. Automated methods tuned for sensitivity often have unacceptably high false positive rates requiring extensive human cleanup.MethodAssume contemporaneous T2*GRE and T1‐weighted images. CMB detection (Figures 1,2) has three steps: 1) Segmentation outputs from the T1‐weighted image are resampled into the T2*GRE image voxel raster; 2) Normalized cross‐correlation of the T2*GRE with a CMB template identifies “candidate CMBs”; 3) a neural network using voxel patches centered on each candidate CMB rejects false positives. Patches presented to the network are 4D and include five contrasts drawn from the T2*GRE, correlation, T1‐weighted, WM probability and CSF probability images. The simple network architecture consists of convolutional blocks followed by dense blocks. The system is trained using images from ADNI, ARIC, MCSA, and the Mayo Clinic ADRC that have been previously visually graded for CMBs (Table in Figure 3). Importantly, we include participants with and without CMBs in our data reflecting the fact that the majority of people (even the elderly) have no CMBs. Data is split 70:10:20 by subject for training, validation, and testing. Various network configurations were evaluated.ResultHigh candidate detection sensitivity can be achieved at the expense of presenting hundreds to thousands of false positive candidates per input image to the rejection network. Our best performing network configuration to date has AUC 0.982 (95% bootstrap CI 0.971 to 0.990 based on the 10% validation subset). Choosing an operating point with 95% sensitivity in the validation set and admits, on average, 0.6 false positive CMB candidates per input T2*GRE image. Sensitivity is hindered by a small number of obvious errors in the ground truth visual assessment. Validation loss tracks training loss with no indication of over‐fitting. Example patches are shown in Figure 4.ConclusionExcessive false positive detection requires significant human correction and effort, preventing automated CMB detection from being widely adopted. We have an automated detection system that is sensitive (95%) and provides excellent false positive rejection (<1 false positive CMB/input image) reducing needed human effort.