Citations

Institution: Mayo Clinic Clear

Showing 10 of 108171 citations.

Characterization of colorectal cancer in patients with primary sclerosing cholangitis & inflammatory bowel disease
Manrique, Gamarra, Coelho–Prabhu, Nayantara

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S98-S99

10.1055/s-0044-1782902 Get It

Human-Computer Interaction: Impact of Artificial Intelligence on the diagnostic confidence of endoscopists assessing videos of Barrett’s esophagus
Röser, D, Meinikheim, M. , Mendel, Robert , Scheppach, Markus W. , Nagl, Sandra , Schnoy, Elisabeth , Schulz, Dominik , Schlottmann, J., Prinz, F., Rauber, David , Rückert, Tobias, Parsa, Nour, Messmann, H, Ebigbo, Alanna , Roser, David , Palm, Christoph , Probst, Andreas , Muzalyova, Anna , Römmele, Christoph , Matsumura, Tomoaki , Fernández‐Esparrach, Glòria , Byrne, Michael F.

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S79-S79

10.1055/s-0044-1782859 Get It

Rate of undetected dysplasia at colectomy in patients with IBD – What are we missing at colonoscopy?
Centorrino, E, Ferrari, Davide , Larson, David W. , Coelho–Prabhu, Nayantara

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S77-S77

10.1055/s-0044-1782855 Get It

Benefits and harms of optical diagnosis by artificial intelligence in colonoscopy: a multicentre cohort study
Halvorsen, Natalie , Kudo, S., Barua, Ishita , Misawa, Masashi , Gulati, Shraddha , Olabintan, Olaolu , Nilsen, J. A., Frigstad, Svein Oskar , Rastogi, A. , Holme, Øyvind , Yuichi, M., Mori, Kensaku , Hayee, Bu , East, James E. , Hassan, Cesare , Kalager, Mette , Løberg, Magnus , Haji, Amyn , Bretthauer, Michael , Yuichi, M.

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S55-S56

10.1055/s-0044-1782806 Get It

International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Romańczyk, Monika , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, P. , Iyer, Prasad G. , Srinivasan, Sachin , Grover, Samir C , Kaminski, Michal Filip , Bisschops, Raf , Bugdol, Marcin Dominik , Gyawali, P., Inoue, H., Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Hassan, Cesare , Sharma, Prateek

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S27-S28

10.1055/s-0044-1782743 Get It

Outpatient COVID-19 convalescent plasma recipient antibody thresholds correlated to reduced hospitalizations within a randomized trial
Park, Han-Sol , Yin, Anna , Barranta, Caelan, Caputo, Christopher , Sachithanandham, Jaiprasath , Li, Maggie , Yoon, Steve, Sitaras, Ioannis , Jedlicka, Anne , Eby, Yolanda , Ram, Malathi , Fernández, Reinaldo E. , Baker, Owen R. , Fukuta, Yuriko , Patel, Bela , Heath, Sonya L. , Spivak, Emily S , Huamán, Moisés A. , Blair, Janis E. , Gerber, Jonathan M. , Petrini, Joann, Broderick, Patrick , Rausch, William, Cordisco, Marie Elena , Hammel, Jean, Greenblatt, Benjamin, Cluzet, Valerie , Cruser, Daniel, Oei, Kevin , Abinante, Matthew, Hammitt, Laura L. , Forthal, Donald N. , Cachay, Edward R. , Marshall, Christi E., Lane, Karen , McBee, Nichol , Gawad, Amy L., Karlen, Nicky, Singh, Atika, Jabs, Douglas A. , Shade, David , Lau, Bryan , Ehrhardt, Stephan , Baksh, Sheriza , Ou, Jiangda , Na, Yu Bin , Knoll, Maria Deloria , Ornelas-Gatdula, Elysse, Gniadek, Thomas J. , Wu, Jinke, Ndahiro, Nelson , Betenbaugh, Michael J. , Ziman, Alyssa , Bloch, Evan M. , Laeyendecker, Oliver , Ziman, Alyssa , Huaman, Moises A , Laeyendecker, Oliver , Lee, John S. , Shenoy, Aarthi , Mosnaim, Giselle S , Levine, Adam C , Meisenberg, Barry R. , Anjan, Shweta , Currier, Judith S. , Paxton, James H , Sutcliffe, Catherine G , Zand, Martin S. , Raval, Jay S. , Kassaye, Seble , Yarava, Anusha , Ford, Daniel E , Appel, Lawrence J. , Shapiro, Janna R. , Arroyo‐Currás, Netzahualcóyotl , Caturegli, Patrizio , Hanley, Daniel F. , Casadevall, Arturo , Shoham, Shmuel , Gebo, Kelly A , Tobian, Aaron A.R. , Pekosz, Andrew , Klein, Sabra L , Sullivan, David

JCI Insight | April 23, 2024 | Volume: 9 | Issue: 8 | Pages: No page available

10.1172/jci.insight.178460 | PMID 38483534 Get It

BACKGROUND COVID-19 convalescent plasma (CCP) virus-specific antibody levels that translate into recipient posttransfusion antibody levels sufficient to prevent disease progression are not defined. METHODS This secondary analysis correlated donor and recipient antibody levels to hospitalization risk among unvaccinated, seronegative CCP recipients within the outpatient, double-blind, randomized clinical trial that compared CCP to control plasma. The majority of COVID-19 CCP arm hospitalizations (15/17, 88%) occurred in this unvaccinated, seronegative subgroup. A functional cutoff to delineate recipient high versus low posttransfusion antibody levels was established by 2 methods: (i) analyzing virus neutralization–equivalent anti–Spike receptor-binding domain immunoglobulin G (anti-S-RBD IgG) responses in donors or (ii) receiver operating characteristic (ROC) curve analysis. RESULTS SARS-CoV-2 anti–S-RBD IgG antibody was volume diluted 21.3-fold into posttransfusion seronegative recipients from matched donor units. Virus-specific antibody delivered was approximately 1.2 mg. The high-antibody recipients transfused early (symptom onset within 5 days) had no hospitalizations. A CCP-recipient analysis for antibody thresholds correlated to reduced hospitalizations found a statistical significant association between early transfusion and high antibodies versus all other CCP recipients (or control plasma), with antibody cutoffs established by both methods-donor-based virus neutralization cutoffs in posttransfusion recipients (0/85 [0%] versus 15/276 [5.6%]; P = 0.03) or ROC-based cutoff (0/94 [0%] versus 15/267 [5.4%]; P = 0.01). CONCLUSION In unvaccinated, seronegative CCP recipients, early transfusion of plasma units in the upper 30% of study donors’ antibody levels reduced outpatient hospitalizations. High antibody level plasma units, given early, should be reserved for therapeutic use. TRIAL REGISTRATION ClinicalTrials.gov NCT04373460. FUNDING Department of Defense (W911QY2090012); Defense Health Agency; Bloomberg Philanthropies; the State of Maryland; NIH (3R01AI152078-01S1, U24TR001609-S3, 1K23HL151826NIH); the Mental Wellness Foundation; the Moriah Fund; Octapharma; the Healthnetwork Foundation; the Shear Family Foundation; the NorthShore Research Institute; and the Rice Foundation.
Abstract 9891: Usefulness of Transthoracic Echocardiography with Strain Analysis in Initial Assessment of Acute Chest Pain in Emergency Department
Lee, Mirae , Sohn, G. Fischer, Choi, Jin‐Oh , Lee, Sang‐Cheol , Oh, Jae K. , Park, Seung Woo , Chang, Sung‐A , Sohn, Gwan-Hyeop, Park, Sung‐Ji

Circulation | April 23, 2024 | Volume: 126 | Issue: suppl_21 | Pages: No page available

10.1161/circ.126.suppl_21.a9891 Get It

Background: Conventional transthoracic echocardiography (TTE) is currently not recommended as an initial test to diagnose coronary artery disease (CAD) due to its insensitivity. Left ventricular (LV) strain was reported to be more sensitive than regional wall motion abnormality (RWMA). The aim of this study was to evaluate the usefulness of TTE including LV strain analysis in initial assessment of acute chest pain in emergency department (ED). Methods: Patients visiting ED with acute chest pain were included. Patients with ST elevation myocardial infarct (MI), hemodynamic instability, known CAD or cardiomyopathy, high probability of non-cardiac chest pain, and poor echocardiographic window were excluded. All the patients were initially assessed by an ED physician for pretest probability of CAD. TTE was performed including LV strain image and global and regional LV longitudinal stain (S GL and S RL ) was analyzed online. S RL abnormality was defined as decreased S RL in at least 2 adjacent segments. Diagnosis of CAD (based on coronary angiography or CT angiography) and cardiac events (cardiac death, revascularization, MI, or recurrent ED visit due to chest pain) were reviewed at 1 month after ED visit. Results: Overall 104 patients were analyzed. CAD was diagnosed in 24% (n=25) and cardiac event was detected in 25% (n=26) of patients.Diagnostic accuracy for CAD was higher when using S RL with cut-off value of -13% (sensitivity of 89%, specificity of 77%, NPV = 92%, PPV = 70%) than when using RWMA (sensitivity of 62%, specificity of 88%, NPV = 80%, PPV = 76%). S RL showed better diagnostic performance for CAD than S GL , and pretest probability (Figure). Predictive value of S RL for cardiac events was also highest in those of S GL , RWMA, and pretest probability (Figure). Conclusion: LV strain echocardiography can diagnose the CAD and predict future events with high accuracy. TTE including strain analysis can be used as an initial diagnostic tool in evaluation of acute chest pain in ED.
Abstract 9501: Gender Differences in Mortality Associated with Implantable Cardioverter-Defibrillator Infections
Braid‐Forbes, Mary Jo, Lerner, Daniel J., Sohail, M. Rizwan , Henrikson, Charles A. , Forbes, Kevin F.

Circulation | April 23, 2024 | Volume: 126 | Issue: suppl_21 | Pages: No page available

10.1161/circ.126.suppl_21.a9501 Get It

Introduction: Implantable cardioverter-defibrillators (ICDs) reduce morbidity and mortality in appropriately selected patients, but device-related infections are associated with significant mortality that can mitigate this benefit. Women are at higher risk for adverse events during ICD procedure admissions, but there are limited data on the mortality associated ICD infection in women. Objective: To compare the clinical characteristics and mortality rate of men and women who have an infection associated with ICD procedure. Methods: Retrospective cohort study of 64,903 Medicare fee-for-service patients admitted for ICD generator implantation, replacement, or revision from January 1, 2007 to December 31, 2007. Primary outcome measures were unadjusted and risk-adjusted longer-term mortality associated with ICD infection. Results: There were a total of 1,855 (2.89%) admissions with an ICD infection. Longer-term mortality (death during admission quarter and subsequent 4 quarters) was significantly higher with ICD infection than without (28.4% vs. 16.7%, P<0.001). While longer-term mortality without ICD infection was significantly lower for women (hazard ratio=0.89 [95%CI 0.85-0.93]), longer-term mortality with ICD infection was significantly higher for women, compared to men (hazard ratio=1.20 [95%CI 1.03-1.41]. Multivariate regression analysis adjusting for age, gender, race/ethnicity and 28 comorbidities demonstrated a significant interaction between gender and ICD infection associated short and, and longer-term mortality. The risk-adjusted longer-term mortality with ICD infection was significantly higher for women compared to men (hazard ratio = 1.25 [95% CI 1.02-1.53]). Conclusions: Women have significantly higher rate of death, compared to men, following infection associated with ICD procedures. Further studies to determine the underlying causes of this disparity are warranted.
Abstract 9355: Mitral Valve Disease in Marfan Syndrome Patients Undergoing Aortic Root Replacement
Kunkala, Meghana R., Zhou, Li , Volguina, Irina V., Coselli, Joseph S. , Connolly, Heidi M. , Schaff, Hartzell V. , LeMaire, Scott A.

Circulation | April 23, 2024 | Volume: 126 | Issue: suppl_21 | Pages: No page available

10.1161/circ.126.suppl_21.a9355 Get It

Background: The primary cardiac manifestations of the Marfan syndrome (MFS) include aortic root dilation and mitral valve prolapse (MVP). There are only scant data describing MV disease in MFS patients who undergo aortic root replacement. Methods: We retrospectively studied 239 patients (90 female; mean age 34 y) with MFS enrolled in a prospective multicenter registry. All patients were referred for repair of aortic root aneurysms with either composite graft aortic valve replacement (AVR, n=59) or an aortic valve-sparing procedure (AVS, n=180). MVP and mitral regurgitation (MR) severity was evaluated by echocardiography preoperatively and during follow-up (postoperatively, 6 months, and 1, 2, and 3 years after surgery). The severity of MR was graded as none, trivial (0), mild (1), moderate (2), moderate to severe (3), or severe (4). Preoperative echocardiography identified MVP in 166 (69%) patients without previous MV intervention. Results: Forty-one (25%) of 166 patients with MVP received AVR, and 125 (75%) received AVS, with similar proportions of patients with preoperative MR grade >2 in the two groups ( p =0.7). Thirty-three patients (20%) underwent concomitant MV intervention: 29 repairs and 4 replacements (15 patients (45%) had MR >2, 11 (33%) had MR=2, and 7 had MR ≤1). All patients with MR >2 underwent a MV procedure. One patient following MV repair required MV replacement on postoperative day 16 after developing grade 4 MR. No other patient required MV reintervention during follow-up (mean clinical follow-up, 30±9 months). Echocardiography performed 21±13 (±1 SD) months postoperatively revealed MR >2 in only 1 of 158 patients. There were 1 early death (bleeding) and 2 late deaths (multi-organ failure and unknown cause); all deaths occurred in patients with concomitant MV surgery. Conclusions: MVP is present in 69% of patients with MFS undergoing aortic root replacement; 20% of patients with MVP underwent a concomitant MV procedure. Short-term results suggest that a simultaneous MV procedure in patients with MR >2 is reasonable because operative risk was not increased and subsequent MV procedures were rare. More follow-up is needed to learn if prophylactic MV intervention at the time of aortic surgery might benefit patients with MR ≤2.