Platelet calcium appears to be essential in platelet activation. Accordingly, Verapamil (a channel calcium blocker) was tested “in vivo” as a possible platelet inhibitor agent. Fifteen dogs underwent bilateral femoral artery grafting with one polytetrafluoroethylene (Gore-Tex) and one autologous vein graft. Peroperatively, five dogs were infused continuously with Verapamil (6 μgs/kg/min) and 9 dogs were left untreated and the arterial prostheses were surgically implanted. Using autologous Indium-111-labeled platelets injected 24 hours prior to surgery as a platelet marker, grafts were removed 1 hour following resumption of blood flow. Radioactivity per unit weight of Gore-Tex, vein and blood were determined with a gamma counter and the relative radioactivity with respect to the internal reference standard of blood is tabulated belowVerapamil-treated dogs showed a significant reduction in the “in vivo” platelet deposition on Gore-Tex and autologous venous grafts. Preliminary data indicates that “in vitro” platelet aggregation with soluble calf skin collagen (515 μg/ml) and ADP (2-100 μm) is not different between control and drug-treated dogs.Calcium channel blockers may be promising “in vivo” platelet inhibitor agents; in addition, they may provide further understanding of the different processes involved in “in vivo” and “in vitro” platelet activation.
Hemodynamic and Symptomatic Consequences of Ventricular Pacing*
NISHIMURA, R.A. et al.: Hemodynamic and symptomatic consequences of ventricular pacing. After implantation of a ventricular demand pacemaker (VVI), occasional patients continue to have dizziness, syncope, or near syncope (“pacemaker syndrome”). To identify patients in whom VVI pacing may have deleterious effects, we compared cuff blood pressure responses to VVI pacing with blood pressure responses to atrioventricsler sequential pacing (DVI) or sinus rhythm in 50 consecutive patients. Patients with intact ventriculoatrial conduction had a much greater decrease in systolic blood pressure with VVI pacing (24 ± 11 mm Hg) than those with ventriculoatrial dissociation (−4 ± 15 mm Hg) (P<0.005). Patients who were in heart failure had a lesser decrease in blood pressure with VVI pacing than did those without failure (P<0.05); 13 of the 14 heart failure patients lacked ventriculoatrial conduction. Ten patients had symptomatic dizziness after VVI pacing; the incidence of symptoms was higher in patients with ventriculoatrial conduction (9 of 23) than in those without ventriculoatrial conduction (1 of 27) (P<0.003). We conclude that the presence of intact ventriculoatrial conduction appears to be a crucial determinent of the hemodynamic response to VVI pacing, and its presence may identify patients who are at risk for “pacemaker syndrome.”
BACKGROUND To test the feasibility of percutaneous deployment of intracoronary polymeric stents, a prototype polyethylene terephthalate (PET) stent and a catheter-based delivery system were developed. METHODS AND RESULTS Polymeric stents were deployed in the coronary arteries of 11 Yucatan swine: six stents were placed in the left anterior descending coronary artery, four stents were placed in the circumflex artery, and one stent was placed in the right coronary artery. Stent deployment was achieved by withdrawal of an outer delivery sheath, thus allowing the PET stent to self-expand to a preformed configuration. Two animals died during surgery, one during stent placement and the other several hours after implantation due to intracoronary thrombus formation. Two animals were electively sacrificed within 24 hours of stent implant to examine the adequacy of stent deployment within the coronary vessel. The remaining seven animals survived until the termination of the study 4-6 weeks later. Light microscopic examination of the stented vessels showed an extensive neointimal proliferative response with vessel occlusion in all animals who survived initial stent placement. There were two distinct types of histological responses to the PET stent--a chronic foreign body inflammatory response around the stent tines and a neointimal proliferative response in the center of the occluded vessel lumen. The histological response seen in the central area of the vessel was morphologically similar to that seen in patients with restenosis after successful percutaneous transluminal coronary angioplasty, whereas the morphological response seen at the periphery of the stent tine was similar to that exhibited by a chronic foreign body reaction and was not typical of that seen in a restenosis lesion. A ventricular aneurysm also developed in the area of myocardium that was previously supplied by the occluded vessel. CONCLUSIONS This study demonstrates that percutaneous deployment of polymeric stents in the coronary arteries is technically feasible. The use of PET polymer was associated with an intense proliferative neointimal response that resulted in complete vessel occlusion. Histological examination of the stented segments of the vessel revealed no evidence that dissection of the vessel wall had occurred at the time of initial stent deployment. Although the PET polymer was of similar quality to that used in the manufacture of balloon angioplasty catheters, a toxic chemical or contaminant effect cannot be completely excluded as the stimulus to intimal proliferation. This finding may have relevance to the selection of materials for use as intravascular devices.