Citations

Mayo Clinic

Clear

7 citation(s) found for "Swartchick, Chelsea B".

New Insights into Unexpected Enzymatic Creatinine Assay Interference: A Case of Acetaminophen Toxicity
Swartchick, Chelsea B. , Rosemark, Christopher L., Block, Darci R , Baumann, N, Katzman, Brooke M. , Baumann, Nikola A

The Journal of Applied Laboratory Medicine | June 30, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag111 | PMID 42519892 Get It

Feasibility of Capillary Self-Collected Blood Specimens for Routine Outpatient Laboratory Testing
Swartchick, Chelsea B. , Gurudu, Rachana, Lexvold, Nathanael S, Lasho, Michael A., Baumann, N, Block, Darci R , Katzman, Brooke M. , Meeusen, Jeffrey W. , Baumann, Nikola A

The Journal of Applied Laboratory Medicine | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag075 | PMID 42206470 Get It

Abstract Background Capillary self-collection (CSC) devices allow patients to collect blood samples at home, potentially reducing outpatient phlebotomy visits. This study aimed to (a) assess the patient experience with multiple commercially available CSC devices; (b) determine which laboratory tests are commonly ordered together, which could reduce the need for appointments; and (c) evaluate the analytical performance of these tests using CSC samples. Methods User experience for 3 CSC devices was evaluated. Clinical feasibility was determined by comparing test results in paired sera collected by venipuncture (VP) and CSC devices. VP samples were centrifuged within 2 h and tested immediately. CSC sera were centrifuged and tested both immediately and after delayed processing to simulate shipping temperature extremes (−20°C or 40°C). Basic metabolic panel, lipid panel, thyroid function cascade, and prostate-specific antigen were evaluated. Differences between VP and CSC collections were characterized according to their statistical and clinical differences. Results Patients reported CSC devices were easy to use and painless. Clinically significant differences between VP and CSC sera processed immediately were limited to potassium and bicarbonate. Following delayed processing of CSC serum samples (48 h at room temperature), clinically significant differences in potassium, bicarbonate, and glucose were observed. Frozen samples could not be analyzed. A 48 h delay at 40°C caused clinically significant differences in all analytes except creatinine, lipid panel, prostate-specific antigen, and the thyroid cascade. Conclusion Potassium, bicarbonate, and glucose were not stable at room temperature in CSC sera. CSC serum specimens may be a viable option but require analyte-specific evaluation and consideration of transportation conditions.
A New IgG-λ Band during Therapy in Light-Chain Myeloma
Swartchick, Chelsea B, Larkin, James M, Kohlhagen, Mindy , Murray, David , Willrich, Maria Alice V. , Kohlhagen, Mindy C, Murray, David L , Willrich, Maria A , Swartchick, Chelsea B.

The Journal of Applied Laboratory Medicine | January 9, 2026 | Volume: 11 | Issue: 4 | Pages: 961-967

10.1093/jalm/jfag004 | PMID 41808379 Get It

Comparison of the Effect of Chronic Kidney Disease on Plasma p ‐tau217 Determinations versus %p‐tau217 and the p ‐tau217/Aβ42 Ratio in an Amyloid Negative Cohort
Swartchick, Chelsea, Vemuri, Prashanthi, Graff‐Radford, Jonathan, Knopman, D S, Weigand, Stephen D. , Griswold, Michael E., Cogswell, Petrice M, Jack, Clifford R., Petersen, Ronald, Bornhorst, Joshua , Swartchick, Chelsea B. , Vemuri, Prashanthi , Graff‐Radford, Jonathan , Knopman, David S. , Cogswell, Petrice M. , Jack, Clifford R. , Petersen, Ronald, Algeciras‐Schimnich, Alicia

Alzheimer's & Dementia | December 25, 2025 | Volume: 21 | Issue: S2 | Pages: No page available

10.1002/alz70856_101203 Get It

Abstract Background Chronic kidney disease (CKD) is associated with increased blood‐based biomarker concentrations, potentially confounding their utility in Alzheimer's disease (AD) evaluation. While plasma phosphorylated tau217 ( p ‐tau217) is elevated in the presence of amyloid related pathology, amyloid beta 1‐42 (Aβ42) is decreased. We investigated the association of plasma p ‐tau217, non‐phosphorylated tau217 (np‐tau217), Aβ42, Aβ40, as well as the Aβ42/Aβ40 and p ‐tau217/Aβ42 ratios, versus decreased estimated glomerular filtration rate (eGFR in mL/min/1.73 m 2 ) in individuals without amyloid pathology. Method This study included participants with CKD stages 1‐2 (eGFR 60‐98, n = 50), and stages 3‐4 (eGFR 25‐59, n = 33), who were Pittsburgh 11 C‐Compound B amyloid‐PET negative (Centiloid of < 25). Plasma p ‐tau217, np‐tau217, Aβ42, and Aβ40 were measured by immunoprecipitation mass spectrometry (C 2 N Diagnostics). %p‐tau217 [( p ‐tau217/np‐tau217) x100], Aβ42/Aβ40 ratio, and p ‐tau217/Aβ42 ratio were calculated. Log‐Log (power function) best‐fit regression analysis was used to quantitatively predict effects of changes in eGFR (2021 CKD‐EPI equation) versus each single analyte or ratio (Figure 1). Result Selected best‐fit analyte equations versus eGFR are shown in Table 1. The predicted percent increase of p ‐tau217 as eGFR decreases from 60 to 45 was 52% (95% CI: 30–78%). Significantly smaller increases of 16% were predicted for Aβ42 (95% CI: 12–21%), and 19% for Aβ40 (95% CI: 16–23%) over the same eGFR range. The best‐fit predicted increase for the p ‐tau217/Aβ42 ratio and %p‐tau217 as eGFR decreases from 60 to 45 was 31% (95% CI: 12–53%), and 19% (95% CI: 2–38%), respectively. While not recommended for assessment of amyloid pathology, the Aβ42/Aβ40 ratio did not exhibit a predicted increase (‐2.3% decrease, 95% CI: ‐5.2–0.6%) versus decreasing eGFR from 60 to 45. Conclusion The use of either %p‐tau217 or the p ‐tau217/Aβ42 ratio (to a lesser degree) reduced the confounding effects of decreasing eGFR as compared to p ‐tau217 alone. Aβ42 and Aβ40 exhibited similar reduced predicted increases versus decreasing eGFR as compared to p ‐tau217. Relative to the predicted effects of decreasing eGFR on p ‐tau217 measurements, the p ‐tau217/Aβ42 ratio relative increase was reduced by 40%, while the relative increase was reduced by 63% for %p‐tau217 measurements.
B-183 Teclistamab: a bispecific monoclonal IgG lambda therapeutic is observable on serum immunofixation and mass-fix
Larkin, James , Swartchick, Chelsea, Kohlhagen, Mindy , Murray, David , Willrich, Maria Alice V.

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.576 Get It

Abstract Background Monoclonal antibody therapies (t-mabs) are known to interfere in serum immunofixation, as they show up as a discrete band. Until recently, most of the t-mabs were IgG kappa monoclonal immunoglobulins, and laboratories were familiar with the clue of a cathodal migrating IgG kappa in a patient sample, suggesting this could be daratumumab or another t-mab in the report. However, with the advent of novel antibody-based medications, identification via traditional laboratory methods has grown more complex. Teclistamab-cqyv is an IgG4 lambda T-cell engager bispecific antibody targeting B-cell maturation antigen (BCMA) and CD3 on T cells, used in relapsed and refractory multiple myeloma. The goal of this study was to determine if teclistamab could be detected on serum immunofixation and mass-fix. Methods Residual waste serum samples with no monoclonal protein via mass-fix (a MALDI-TOF based assay used in place of serum immunofixation) and variable polyclonal background were used to spike teclistamab (n=3). Briefly, one sample had total IgG &lt; 500 mg/dL measured by nephelometry on a Siemens BNII (431 mg/dL, hypo gamma), a second sample had IgG within reference intervals (779 mg/dL, normal gamma) and the third sample had IgG &gt; 1600 mg/dL (1950 mg/dL, polyclonal hypergamma). Each sample was divided into 3 aliquots and spiked with teclistamab (Tecvayli, Johnson &Johnson) obtained from the pharmacy, at final concentrations of 10, 20, and 40 mg/dL in the serum samples. The nine artificial samples were subjected to immunofixation electrophoresis (Sebia) and a new monoclonal protein study using mass-fix, a laboratory developed test. Results In the serum immunofixation experiments, a single discrete IgG lambda band was visible in the hypogamma and normal gamma samples (Table 1) when teclistamab was present at 20 mg/dL or 40 mg/dL. No bands were observed for the 10 mg/dL spike in hypos or normals. No teclistamab was detected at any concentration in the hypergamma sample. When mass-fix was performed, monoclonal protein spikes consistent with the expected mass of the two unique lambda light chains associated with teclistamab (22624Da and 22636Da) were identified in the hypo and normal gamma samples at the 3 concentrations tested: 10, 20, and 40 mg/dL. No mass-fix spikes were seen above the polyclonal spectra in the hypergamma samples. Conclusion The polyclonal background of immunoglobulins in a serum specimen plays a significant role in the identification of any monoclonal protein. Teclistamab is a new IgG lambda t-mab with potential to show up as an interference in both immunofixation and mass-fix, depending on the amount of polyclonal IgG present. Without positive identification, teclistamab presence could complicate interpretation of a patient’s response to treatment. This proof-of-concept study shows that mass-fix can detect smaller concentrations of teclistamab than immunofixation, therefore would be more prone to identifying this t-mab than labs employing the gel-based immunofixation method.
A-207 Investigating an Increase in Specimen Recollection Rates Due to Hemolysis After a Testing Location Change: The Impact of Specimen Type and Patient Population
Mohamed, Sulieman, Kelley, Brandon, Wockenfus, Amy M., McGinn, Alec, Lexvold, Nathaniel, Swartchick, Chelsea B. , Katzman, Brooke M.

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.201 Get It

Abstract Background The Oncology Department at our institution requested faster turn-around times (TAT) for chemistry testing. Prior to their request, serum separator tubes (SST) were collected and tested in our core laboratory. To accommodate the request, we added plasma total bilirubin and aspartate aminotransferase (AST) to our stat laboratory test menu with collection in plasma separator tubes (PST). Upon implementation of this testing change, we observed an increase in specimen recollection rates due to hemolysis. We systematically evaluated laboratory testing variables that could have contributed to the increase: pneumatic tube transport path, differences in hemolysis measurements between chemistry analyzer models, and specimen types. Previous studies have demonstrated that lithium heparin plasma specimens are more susceptible to hemolysis than serum. Likewise, patients undergoing chemotherapy or radiation therapy may have fragile red blood cell (RBC) membranes, further complicating the issue. Our study*s objective was to assess the impact of changing from SST to PST collections. We conducted a 3-month pilot study to determine if we could reduce our recollection rates by collecting/testing Rapid Serum Tube (RST), while maintaining plasma TAT. Methods We compared recollection rates for specimens collected from the oncology patients and tested in our core laboratory (SST, May-June 2021), stat laboratory (PST, September-November 2022), pilot period in stat lab (RST, January-March 2023), and post-pilot period in stat lab (PST, May-July 2023). Data were extracted from our laboratory information system and recollection rates were calculated using Tableau (Salesforce, Inc, San Francisco, CA). Analysis was performed in Excel (Microsoft, Redmond, WA) using Student’s t-test, with p &lt; 0.05 defined as statistically significant. Results SST specimens collected from oncology patients and tested in the core lab (May-June 2021) resulted in a recollection rate of 0.17% (4/2341). PST specimens sent to the stat lab (Sept-Nov 2022) had an increased recollection rate of 0.90% (55/6129, p-value &lt; 0.001). During the pilot period when RST tubes were used (Jan-Mar 2023), our recollection rate decreased to 0.19% (11/5801, p-value 0.014). After the pilot period ended and PST tubes were again utilized for testing (May-July 2023), the recollection rate again increased to 0.34% (22/6500, p-value 0.019). Conclusion Rapid TAT of laboratory results within specialized-care settings, such as a cancer treatment clinic, is necessary to provide patients with the most effective and personalized treatment regimens. Hemolysis presents a challenge as it generates an analytical issue with the release of contents from RBCs that may spuriously affect the concentration of the analyte being measured, delaying result reporting due to the need for specimen recollection. The data from our study highlight the utility of rapid serum tubes. Not only did they achieve stat TAT that was observed with the use of PST, but they also decreased specimen recollection rates that mirror the low rates observed with the use of SST. Thus, this technology may be an excellent replacement for standard SST when specimen integrity is critical to rapidly reporting accurate test results.
A-112 Differential effects of chronic kidney disease on circulating concentrations of phosphorylated tau and beta amyloid Alzheimer’s Disease blood biomarkers
Swartchick, Chelsea, Bornhorst, Joshua A. , Algeciras-Schimnich, Alicia, Bornhorst, Joshua , Algeciras‐Schimnich, Alicia

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvaf086.110 Get It

Abstract Aims Blood biomarkers (BBMs) are promising minimally invasive tools for the evaluation of Alzheimer’s disease (AD). However, recent studies have demonstrated that comorbidities, such as severe chronic kidney disease (CKD), may elevate circulating concentrations of various BBMs including amyloid-ß (Aß) and phosphorylated tau proteins (p-tau). Previous work has found that the effects of CKD on BBM plasma concentrations could be partially mitigated through use of biomarker ratios (e.g., the proportion of p-tau217 to non-phosphorylated tau217 (np-tau217)). In this work, we quantitatively evaluate how different combinations of BBM ratios and single biomarkers are affected in the context of decreased kidney function. Methods Participants (n=83, &gt;57 years of age) with CKD stages 1-2 (eGFR 60-98, n = 50), and stages 3-4 (eGFR 25-59, n = 33) and without amyloid pathology (A-) were included. eGFR (mL/min/1.73 m2) was calculated using the 2021 CKD-EPI equation based on serum-paired creatinine measurements. Plasma p-tau217, np-tau217, p-tau181, np-tau181, Aß42, and Aß40 were measured by mass spectrometry (MS) (C2N Diagnostics). %p-tau217 [(p-tau217/np-tau217) x 100], %p-tau181 [(p-tau181/np-tau181) x 100], Aß42/Aß40 ratio, and p-tau217/Aß42 ratio were calculated. Log-Log (power function) best-fit regression analysis was used to quantitatively predict the relationship of BBM changes as a function of eGFR. Results Median concentrations of p-tau217, np-tau217, p-tau181, np-tau181, Aß42, and Aß40 were all significantly elevated in individuals with eGFR &lt;60 mL/min/1.73 m2 compared to those with eGFR &gt; or =60 (all p &lt; 0.05). There were no differences in the %p-tau217 and Aß42/Aß40 median values between these two groups (eGFR &lt;60 versus &gt; or =60) (p &gt; 0.05); whereas the proportions %p-tau181 and p-tau217/Aß42 median values were higher in the eGFR &gt; or =60 group versus the &lt;60 subset. Observed best-fit analyte regression equations of eGFR versus BBM concentrations predict that an eGFR decrease from 60 to 45 results in p-tau217 and p-tau181 increases of 52% (95% confidence interval (CI): 30–78%) and 40% (95% CI: 29–53%), respectively. A 16% (95% CI: 12–21%), and a 19% (95% CI: 16–23%) increase was predicted in response to the same eGFR decline for Aß42 and Aß40. Furthermore, increases of 19% (95% CI: 2–38%) for %p-tau217, 6% (95% CI: -0.02–13%) for %p-tau181 and 31% (95% CI: 12–53%) for p-tau217/Aß42 were predicted as eGFR declined from 60 to 45, while a minor decrease of 2.3% (95% CI: -5.2–0.6%) was predicted for Aß42/Aß40. Conclusions: Reduction in eGFR is associated with significant elevations in plasma concentrations of p-tau217, p-tau181, Aß42, and Aß40, which may affect the interpretations of these biomarkers. However, the use of %p-tau217, %p-tau181, or p-tau217/Aß42 could partially attenuate this effect. Although the Aß42/Aß40 ratio is not considered an effective diagnostic BBM for AD, this ratio was relatively unaffected by CKD. For example, in comparison to p-tau217 alone, using %p-tau217 or p-tau217/Aß42, the relative increase in analyte values associated with decreased eGFR was reduced by 63% and 40%, respectively. These findings provide a better understanding of the effect of reduced eGFR on AD BBM interpretation in the presence of CKD.