Citations

Mayo Clinic

Clear

35 citation(s) found for "Osmonov, D".

(236) Multicenter Evaluation on the Use of Down-Sized Cylinders in Penile Prosthesis Surgery
Chawareb, E Abou, Lee, J, Campos, L, Hammad, M Moukhtar, Miller, J, Azad, B, Swerdloff, D, Osmonov, D, Sadeghi-Nejad, H, Burnett, A, Pearce, I, Lentz, A, Modgil, V, Warner, J N, Ziegelmann, M, Jr., A Suarez-Sarmiento, Perito, P, Simhan, J, Gross, M, Yafi, F A, Barham, D, Hammad, Muhammed , Azad, Babak Kazemzadeh , Swerdloff, Daniel , Sadeghi‐Nejad, Hossein , Burnett, Arthur L. “Bud” , Pearce, Ian , Lentz, A, Modgil, Vaibhav , Ziegelmann, Matthew , Suarez‐Sarmiento, Alfredo, Perito, P, Simhan, Jay , Barham, David W.

The Journal of Sexual Medicine | June 4, 2026 | Volume: 23 | Issue: Supplement_4 | Pages: No page available

10.1093/jsxmed/qdag118.217 Get It

Abstract Introduction Down-sized inflatable penile prosthesis (IPP) cylinders are used in challenging penile fibrosis scenarios, such as after priapism or prior implant infection. Their role in primary penile prosthesis surgery, however, is not well studied. Objective This study aims to identify factors associated with the use of down-sized cylinders in men undergoing primary IPP placement. Methods We conducted a multicenter, retrospective study on men undergoing primary IPP surgery, categorizing them into a down-sized cylinder group (AMS 700 CXR and Coloplast NB) and a standard cylinder group (AMS 700 CX, AMS 700 LGX, and Coloplast Titan). We collected demographic, intraoperative, and postoperative variables and performed a multivariable analysis. Results 4,389 men were included in the study with a mean age of 62.3±10.3 years. Overall, 1,485 (34%) men had diabetes, and 2,131 (49%) had hypertension. Down-sized cylinders were placed in 406 men (174 CXRs, 232 NBs), while standard cylinders were placed in 3,983. Multivariable analysis indicated that down-sized cylinders were more commonly used in men with diabetes (OR 2.6 [1.9, 3.7], p<0.001) and less frequently in men with hypertension (OR 0.5 [0.4, 0.7], p<0.001). A history of priapism did not significantly impact the use of down-sized cylinders (p≥0.152). Sequential dilation was performed more often with the use of down-sized cylinders (OR 4.0 [2.8, 5.7], p<0.001). Down-sized cylinders were associated with an increased rate of non-infectious complications (OR 1.9 [1.3, 2.9], p<0.001), however, there was no significant association with implant infection (OR 2.1 [0.9, 4.6], p=0.07). Non-infectious complications occurred in 44 (25%) men with down-sized cylinders. In the down-sized group, hematomas occurred in 10 (2.5%) men and wound-related complications occurred in 7 (1.7%) men (Table 1). Cylinder-related complications occurred in 7 (1.7%) men with down-sized cylinders. Device-related malfunctions were seen in 8 (2%) men. Conclusions This study demonstrates that down-sized cylinders are more frequently used in men with diabetes and surgeons should be prepared to place down-sized cylinders in these men. Prosthetic urologists are also more likely to use down-sized cylinders in men requiring sequential dilation likely due to fibrosis or more challenging dilations. Down-sized cylinders are associated with a low overall complication rate. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Intuitive Surgical, Fidelis, Urofill, Boston Scientific, Coloplast, Cynosure, Antares Pharma, Clarus Pharmaceuticals, Acerus Pharma; Endo Pharma.
(389) Multicenter Evaluation on the Use of Down-Sized Cylinders Penile Prosthesis: When to Go Narrow?
Lee, J, Swerdloff, Daniel , Sadeghi‐Nejad, Hossein , Pearce, Ian , Lentz, A, Gross, Kelli, Hotaling, James M. , Sempels, Maxime, Park, S Hun, Renterghem, Katrien Van, Hatzichristodoulou, G, Levy, Jason A. , Andrianne, Robert, Hsieh, Tung‐Chin , Modgil, Vaibhav , Jones, Adam , Warner, J, Ziegelmann, M., Suarez-Sarmiento, A, Perito, P, Simhan, Jay , Gross, M, Yafi, Faysal A. , Barham, David , Lee, J, Chawareb, Elia Abou , Hammad, M, Miller, Jake A. , Azad, Babak Kazemzadeh , Osmonov, D, Burnett, Arthur L. “Bud” , Lentz, A, Hatzichristodoulou, Georgios , Levy, J, Jones, James M. , Suarez‐Sarmiento, Alfredo, Gross, Martin

The Journal of Sexual Medicine | December 9, 2025 | Volume: 22 | Issue: Supplement_4 | Pages: No page available

10.1093/jsxmed/qdaf320.383 Get It

Abstract Introduction Down-sized inflatable penile prosthesis (IPP) cylinders are useful in cases with substantial penile fibrosis such as history of priapism or prior infection. Although down-sized IPP cylinders have a clear role in fibrotic corpora, their role in primary implant cases is unclear. Objective To identify factors associated with the use of down-sized cylinders in men undergoing primary IPP placement. Methods We conducted a retrospective analysis of 4,389 patients undergoing primary IPP placement from our multicenter database. Patients were categorized by down-sized (AMS 700 CXR, Coloplast NB) vs. standard sized cylinders (AMS 700 CX, AMS 700 LGX, Coloplast Titan). We collected demographic, intraoperative, and postoperative data. A multivariable analysis was performed to identify factors associated with use of down-sized cylinders Results A total of 4,389 men undergoing primary inflatable penile prosthesis (IPP) placement were included in the study, with a mean age of 62.3 ± 10.3 years. Among them, 1,485 (34%) had diabetes and 2,131 (49%) had hypertension. A total of 406 down-sized cylinders and 3,983 standard cylinders were implanted. Non-infectious complications occurred more frequently with the use of down-sized cylinders (odds ratio [OR] = 2.0, p < 0.001). Specifically, non-infectious complications were reported in 44 out of 185 men (23.8%) with down-sized cylinders, compared to 192 out of 2,727 men (10.9%) with standard cylinders. Cylinder complications constituted 13.9% and 13.0% of the non-infectious complications in the down-sized and standard cylinder groups, respectively. Conclusions The rate of cylinder-related complications were similar between the down-sized cylinder and standard cylinder groups. Urologists should be prepared to place down-sized cylinders during IPP placement in diabetic men and in men requiring serial dilation due to fibrosis. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Intuitive Surgical, Fidelis, Urofill, Boston Scientific, Coloplast, Cynosure, Antares Pharma, Clarus Pharmaceuticals, Acerus Pharma; Endo Pharma.
(010) UNVEILING THE IMPACT OF BODY MASS INDEX ON OVERALL OUTCOMES OF INFLATABLE PENILE PROSTHESIS PLACEMENT: INSIGHTS FROM AN INTERNATIONAL, MULTI-CENTER INVESTIGATION
Hammad, MAM, Gross, MS, Andrianne, Robert, Burnett, AL, Gross, Kelli, Hatzichristodoulou, G, Lentz, A, Modgil, Vaibhav , Perito, P, Hotaling, JM, Park, SH, Pearce, Ian , Sadeghi‐Nejad, Hossein , Sempels, Maxime, Suarez-Sarmiento, A, Renterghem, Katrien Van, Warner, J, Ziegelmann, Matthew , Hsieh, TC, Karthikeyan, Hridhay, Simhan, Jay , Yafi, FA, collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW, Hammad, Muhammed , Miller, Jake A. , Chawareb, Elia Abou , Amini, Erfan , Hatzichristodoulou, Georgios , Lentz, A, Osmonov, D, Suarez‐Sarmiento, Alfredo, Azad, Babak Kazemzadeh , Jenkins, Lawrence C. , Jones, James M. , collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW

The Journal of Sexual Medicine | October 25, 2025 | Volume: 21 | Issue: Supplement_6 | Pages: No page available

10.1093/jsxmed/qdae161.010 Get It

Abstract Introduction Obesity, defined as an elevated Body Mass Index (BMI) >30, is a prevalent public health concern with far-reaching implications for various medical procedures and outcomes. In the context of inflatable penile prosthesis placement (IPP), where patient well-being and surgical success are of paramount importance, the impact of obesity on postoperative and intraoperative complications warrants thorough investigation. Objective Our study aimed to investigate the impact of BMI on both postoperative and intraoperative complications in an international, multi-institutional cohort of patients who underwent IPP placement. Methods We performed a retrospective chart review of 4398 cases. These cases were divided into two distinct groups based on BMI: less than 30 (n = 2260) and greater than or equal to 30 (n = 2138). The study assessed various surgical factors as well as complications, including overall complications, corporal scarring, incontinence, intraoperative complications, proximal perforation, distal perforation, proximal crossover, distal crossover, and urethral injury. Results Our analysis revealed that there were no statistically significant differences in intraoperative or postoperative complications between the two BMI categories. Notably, proximal corporal measurement was significantly higher for >30 BMI group (9.55 +/−2.18) compared to <30 BMI group (9.14 +/−2.19), (p = < 0.001). The incidence rates for overall complications (30.2% vs. 28.7%; p = 0.164), corporal scarring (18.2% vs. 16.7%; p = 0.36), incontinence (3.53% vs. 3.13%; p = 0.076), intraoperative complications (1.94% vs. 1.68%; p = 0.253), and specific complications all exhibited no significant differences. Similarly, post-operative complications, including both non- infectious (6.99% vs. 6.22%; p = 0.215) and infectious (2.61% vs. 1.87%; p = 0.165) complications, did not significantly vary between BMI categories. Conclusions Our findings indicate that BMI does not exert a statistically significant influence on postoperative and intraoperative complications in the context of high-volume prosthetic urology. In the absence of any other differences between patients of differing BMIs, surgeons may need to be mindful of pump tubing length concerns in obese patients. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Coloplast, Clarus Therapeutics, Antares Pharma, Acerus.
Vacuum erectile devices for erectile dysfunction: recommendations from the 5th international consultation on sexual medicine
Wang, Run , Ralph, David , Hatzichristodoulou, Georgios , Osmonov, Daniar , Parker, Justin , Park, Sung Hun , Moncada, Ignacio , Munarriz, Ricardo , Köhler, Tobias , Martins, Francisco E. , Bettocchi, Carlo

Sexual Medicine Reviews | February 17, 2025 | Volume: 13 | Issue: 2 | Pages: 172-183

10.1093/sxmrev/qeaf002 | PMID 39957431 Get It

Abstract Introduction Vacuum erectile device (VED) is 1 of the main approved therapies for erectile dysfunction (ED). The introduction of phosphodiesterase type 5 inhibitor (PDE5i) for ED significantly changed the roles of VED in contemporary sexual medicine. Objective To provide updated clinical evidence to inform health care providers on best practices with VED. Methods A consensus panel was held with leading sexual medicine experts during the 5th International Consultation on Sexual Medicine (ICSM). Relevant peer-reviewed literature was reviewed with focus on research from the last 10 years, but not limited to the last 10 years. The expert panel generated consensus statements based on the quality of evidence and criteria of Grading of Recommendations Assessment, Development and Evaluation. Results As a primary or combination therapy for ED, VED has been shown to be successful in all populations studied, including difficult to treat cohorts, such as diabetes mellitus, spinal cord injury, and post-radical prostatectomy (RP), but long-term attrition rates are high. Available evidence has shown that VED can preserve or restore penile size for patients after RP, after incision and grafting surgery for Peyronie’s disease, before and after penile prosthesis, and after other post pelvic surgeries. However, it has not demonstrated a more rapid recovery of spontaneous erectile function after RP. VED does not increase penile length for subjective short penis. Studies with female specific VED for female sexual dysfunction are very limited. Conclusions Since the prior 4th ICSM, more evidence is available to support the new roles of VED in contemporary sexual medicine. Research into the penile pathophysiologic changes with VED therapy and clinical outcomes for various conditions are ongoing. We encourage sexual medicine clinicians to follow the 5th ICSM recommendations, but providers should also use their own judgement and adopt shared decision making with their patients/partners when considering VED for a specific disorder.
Penile prosthesis for erectile dysfunction: recommendations from the 5th International Consultation on Sexual Medicine
Köhler, Tobias S. , Munarriz, Ricardo , Parker, Justin , Hatzichristodoulou, Georgios , Moncada, Ignacio , Park, Sung Hun, Ralph, David , Wang, Run , Bettocchi, Carlo , Martins, Francisco E. , Osmonov, Daniar

Sexual Medicine Reviews | January 30, 2025 | Volume: 13 | Issue: 2 | Pages: 144-171

10.1093/sxmrev/qeaf001 | PMID 40072010 Get It

Abstract Introduction Penile prosthesis (PP) is one of the main approved therapies for erectile dysfunction (ED). Greater than 50 years of clinical use has led to considerable innovation in PP surgery and patient care. Objectives To summarize the current literature and provide updated clinical evidence to inform healthcare providers on best practices with PP. Methods A consensus panel was held with leading sexual medicine experts during the 5th International Consultation on Sexual Medicine (ICSM). Relevant peer-reviewed literature was reviewed with focus on research from but not limited to the last 10 years. The quality of each individual study was judged with Oxford levels of evidence (LOE) criteria, but overall LOE were not used as systematic review was not performed. The expert panel generated consensus statements based on the quality of evidence and criteria of GRADE (Grading of Recommendations Assessment, Development and Evaluation). Results PP provides excellent outcomes for the treatment of ED. The panel developed 35 recommendations building upon previous recommendations. Nine recommendations (4, 5, 11,13,17, 25, 26, 31, and 32) are retained without change from 2015. Twelve recommendations (1, 2, 3, 7, 9,14,16,19,21, 28, 33, and 34) change syntax to make statements more active or change details. Fourteen recommendations (6, 8, 10, 12, 15, 18, 20, 22, 23, 24, 27, 29, 30, and 35) are novel in this update. Conclusion Since the 4th ICSM, new evidence has emerged to guide PP use in modern sexual medicine. While multi-institutional studies are needed to improve outcomes, key challenges remain: reducing infections, enhancing devices, and improving awareness and accessibility. We recommend following 5th ICSM guidelines while emphasizing the importance of clinical judgment and shared decision-making for optimal PP outcomes.
(230) EXPLORING HOW BMI SHAPES THE SUCCESS OF INFLATABLE PENILE PROSTHESIS SURGERY: MULTI-CENTER STUDY INSIGHTS
Hammad, Muhammed , Gross, MS, Andrianne, Robert, Burnett, AL, Gross, Kelli, Hatzichristodoulou, G, Lentz, A, Modgil, Vaibhav , Perito, P, Hotaling, JM, Park, SH, Pearce, Ian , Sadeghi‐Nejad, Hossein , Sempels, Maxime, Suarez-Sarmiento, A, Renterghem, Katrien Van, Warner, J, Ziegelmann, Matthew , Hsieh, TC, Karthikeyan, Hridhay, Simhan, J, Yafi, FA, collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW, Hammad, Muhammed A M , Miller, John D. , Chawareb, Elia Abou , Amini, Erfan , Hatzichristodoulou, Georgios , Osmonov, D, Perito, P, Suarez‐Sarmiento, Alfredo, Azad, Babak Kazemzadeh , Jenkins, Lawrence C. , Jones, James M. , Simhan, Jay , collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW

The Journal of Sexual Medicine | December 11, 2024 | Volume: 21 | Issue: Supplement_7 | Pages: No page available

10.1093/jsxmed/qdae167.224 Get It

Abstract Introduction Obesity, defined as an elevated Body Mass Index (BMI) >30, is a prevalent public health concern with far-reaching implications for various medical procedures and outcomes. In the context of inflatable penile prosthesis placement (IPP), where patient well-being and surgical success are of paramount importance, the impact of obesity on postoperative and intraoperative complications warrants thorough investigation. Objective We aimed to investigate the impact of BMI on both postoperative and intraoperative complications in an international, multi-institutional cohort of patients who underwent IPP placement. Methods We performed a retrospective chart review of 4,398 cases. These cases were divided into two distinct groups based on BMI: less than 30 (n = 2,260) and greater than or equal to 30 (n = 2,138). The study assessed various surgical factors as well as complications, including overall complications, corporal scarring, incontinence, intraoperative complications, proximal perforation, distal perforation, proximal crossover, distal crossover, and urethral injury. Results Our analysis revealed that there were no statistically significant differences in intraoperative or postoperative complications between the two BMI categories. Notably, proximal corporal measurement was significantly higher for >30 BMI group with 1858 (86.9%) compared to 1919 (84.9%) for <30 BMI group, (p = < 0.001). The incidence rates for overall complications (30.2% vs. 28.7%; p = 0.164), corporal scarring (18.2% vs. 16.7%; p = 0.36), incontinence (3.53% vs. 3.13%; p = 0.076), intraoperative complications (1.94% vs. 1.68%; p = 0.253), and specific complications all exhibited no significant differences. Similarly, post-operative complications, including both non-infectious (6.99% vs. 6.22%; p = 0.215) and infectious (2.61% vs. 1.87%; p = 0.165) complications, did not significantly vary between BMI categories. Conclusions Our findings indicate that BMI does not exert a statistically significant influence on postoperative and intraoperative complications in the context of high-volume prosthetic urology. In the absence of any other differences between patients of differing BMIs, the IPP industry may need to consider device specific alterations with pump tubing length in obese patients. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Coloplast, Clarus Therapeutics, Antares Pharma, Acerus.