Back to Authors

Barham, D

Mayo Clinic

Brooke Army Medical Center

Citations 2

(236) Multicenter Evaluation on the Use of Down-Sized Cylinders in Penile Prosthesis Surgery
Chawareb, E Abou, Lee, J, Campos, L, Hammad, M Moukhtar, Miller, J, Azad, B, Swerdloff, D, Osmonov, D, Sadeghi-Nejad, H, Burnett, A, Pearce, I, Lentz, A, Modgil, V, Warner, J N, Ziegelmann, M, Jr., A Suarez-Sarmiento, Perito, P, Simhan, J, Gross, M, Yafi, F A, Barham, D, Hammad, Muhammed , Azad, Babak Kazemzadeh , Swerdloff, Daniel , Sadeghi‐Nejad, Hossein , Burnett, Arthur L. “Bud” , Pearce, Ian , Lentz, A, Modgil, Vaibhav , Ziegelmann, Matthew , Suarez‐Sarmiento, Alfredo, Perito, P, Simhan, Jay , Barham, David W.

The Journal of Sexual Medicine | June 4, 2026 | Volume: 23 | Issue: Supplement_4 | Pages: No page available

10.1093/jsxmed/qdag118.217 Get It

Abstract Introduction Down-sized inflatable penile prosthesis (IPP) cylinders are used in challenging penile fibrosis scenarios, such as after priapism or prior implant infection. Their role in primary penile prosthesis surgery, however, is not well studied. Objective This study aims to identify factors associated with the use of down-sized cylinders in men undergoing primary IPP placement. Methods We conducted a multicenter, retrospective study on men undergoing primary IPP surgery, categorizing them into a down-sized cylinder group (AMS 700 CXR and Coloplast NB) and a standard cylinder group (AMS 700 CX, AMS 700 LGX, and Coloplast Titan). We collected demographic, intraoperative, and postoperative variables and performed a multivariable analysis. Results 4,389 men were included in the study with a mean age of 62.3±10.3 years. Overall, 1,485 (34%) men had diabetes, and 2,131 (49%) had hypertension. Down-sized cylinders were placed in 406 men (174 CXRs, 232 NBs), while standard cylinders were placed in 3,983. Multivariable analysis indicated that down-sized cylinders were more commonly used in men with diabetes (OR 2.6 [1.9, 3.7], p<0.001) and less frequently in men with hypertension (OR 0.5 [0.4, 0.7], p<0.001). A history of priapism did not significantly impact the use of down-sized cylinders (p≥0.152). Sequential dilation was performed more often with the use of down-sized cylinders (OR 4.0 [2.8, 5.7], p<0.001). Down-sized cylinders were associated with an increased rate of non-infectious complications (OR 1.9 [1.3, 2.9], p<0.001), however, there was no significant association with implant infection (OR 2.1 [0.9, 4.6], p=0.07). Non-infectious complications occurred in 44 (25%) men with down-sized cylinders. In the down-sized group, hematomas occurred in 10 (2.5%) men and wound-related complications occurred in 7 (1.7%) men (Table 1). Cylinder-related complications occurred in 7 (1.7%) men with down-sized cylinders. Device-related malfunctions were seen in 8 (2%) men. Conclusions This study demonstrates that down-sized cylinders are more frequently used in men with diabetes and surgeons should be prepared to place down-sized cylinders in these men. Prosthetic urologists are also more likely to use down-sized cylinders in men requiring sequential dilation likely due to fibrosis or more challenging dilations. Down-sized cylinders are associated with a low overall complication rate. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Intuitive Surgical, Fidelis, Urofill, Boston Scientific, Coloplast, Cynosure, Antares Pharma, Clarus Pharmaceuticals, Acerus Pharma; Endo Pharma.
(148) Irrigation With 0.05% Chlorhexidine Gluconate Associated with Hydrophilic Inflatable Penile Prosthesis Infection: A Large Multi-Institutional Cohort Study
Ivan, S, Chawareb, E Abou, Eftekharzadeh, S, Hammad, M Moukhtar, Campos, L, Bajic, P, Barham, D, Bernie, H, Chung, P, Helo, S, Köhler, T, Lentz, A, Morey, A, Perito, P, Sadeghi-Nejad, H, Shridharani, A, Welliver, C, Yafi, F A, Gross, M, Simhan, J, Hammad, Muhammed , Bajic, P, Barham, David W. , Helo, S, Köhler, Tobias , Lentz, A, Morey, Allen F. , Perito, P, Sadeghi‐Nejad, Hossein , Shridharani, Anand, Welliver, Charles , Simhan, Jay

The Journal of Sexual Medicine | June 4, 2026 | Volume: 23 | Issue: Supplement_4 | Pages: No page available

10.1093/jsxmed/qdag118.132 Get It

Abstract Introduction 0.05% Chlorhexidine Gluconate (CHG) has gained popularity as an irrigant and dip for inflatable penile prosthesis (IPP) surgery. Prior in vitro data is conflicting on the impact of CHG use with hydrophilic coated devices. Objective We sought to identify possible associations between CHG use and hydrophilic IPP infection rate. Methods We conducted a retrospective cohort study of 2,933 patients undergoing IPP implantation across 14 referral centers. Data collection spanned from January 1, 2017 to March 1, 2024. Each surgeon contributed patients who underwent IPP implantation with CHG used as an irrigant and/or dip as well as an equal number of consecutive control patients without CHG use. The primary outcome was IPP explant for postoperative infection. Univariable analysis was used to compare patient demographics, and logistic regression analysis was performed to assess factors associated with infection. Results Hydrophilic devices were implanted in 2,150 patients. Median follow-up for non-CHG patients was 13 months (IQR 18) and four months (IQR 9) for CHG patients. The incidence of infection with intraoperative CHG use was significantly higher compared to those without CHG use (4.6%, 46/1,001 vs. 2.1%, 24/1,148, p<0.001). On multivariable logistic regression analysis, intraoperative CHG use was associated with infection (OR 2.07, 95% CI 1.24-3.47, p=0.01). Additional variables associated with infection included immunosuppression, prior IPP infection, prior priapism, and revision surgery (p<0.01, Table). On subgroup analyses, the increased infection risk of CHG was most clear when CHG was used as both irrigation and dip (OR 2.03, 95% CI 1.19-3.46, p=0.01) and when CHG was used during revision surgery (OR 3.36, 95% CI 1.15-9.82, p=0.03). Conclusions In a large multi-institutional cohort, intraoperative CHG use was associated with an elevated incidence of hydrophilic IPP infection. Providers may take these findings into consideration when performing IPP surgery with hydrophilic devices, especially during revision surgery. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Intuitive Surgical, Fidelis, Urofill, Boston Scientific, Coloplast, Cynosure, Antares Pharma, Clarus Pharmaceuticals, Acerus Pharma; Endo Pharma