Citations

Mayo Clinic

Clear

1140 citation(s) found for "Núñez, Jorge".

Simulation: An Effective Method of Teaching Cosmetic Botulinum Toxin Injection Technique
Mitkov, Mario , Thomas, Colleen S. , Cochuyt, Jordan J., Forte, Antonio J. , Mitkov, Mario V., Forte, Antonio Jorge , Perdikis, Galen

Aesthetic Surgery Journal | July 3, 2018 | Volume: 38 | Issue: 12 | Pages: NP207-NP212

10.1093/asj/sjy159 | PMID 29982282 Get It

History of the World Society for Pediatric and Congenital Heart Surgery: The First Decade
Tchervenkov, Christo I., Kurosawa, Hiromi, Mavroudis, Constantine , Jatene, Marcelo Biscegli , Al‐Halees, Zohair , Çïçek, Sertaç , Sandoval, Néstor , Backer, Carl L., Cervantes, Jorge , Edwin, Frank , Finucane, Kirsten , Iyer, Krishna, Kinsley, Robin H. , Kreutzer, Christián , Liu, Jinfen , Maruszewski, Bohdan , Sarris, George E. , Jonas, Richard A. , Çiçek, Sertaç M, Jacobs, Jeffrey P. , Stellin, Giovanni , Dearani, Joseph A. , Ebels, Tjark , Fragata, José , Kirklin, James K. , Louis, James D. St.

World Journal for Pediatric and Congenital Heart Surgery | June 26, 2018 | Volume: 9 | Issue: 4 | Pages: 392-406

10.1177/2150135118775962 | PMID 29945512 Get It

The World Society for Pediatric and Congenital Heart Surgery (WSPCHS) is the largest professional organization in the world dedicated to pediatric and congenital heart surgery. The purpose of this article is to document the first decade of the history of WSPCHS from its formation in 2006, to summarize the current status of WSPCHS, and to consider the future of WSPCHS. The WSPCHS was incorporated in Canada on April 7, 2011, with a head office in Montreal, Canada. The vision of the WSPCHS is that every child born anywhere in the world with a congenital heart defect should have access to appropriate medical and surgical care. The mission of the WSPCHS is to promote the highest quality comprehensive cardiac care to all patients with congenital heart disease, from the fetus to the adult, regardless of the patient’s economic means, with an emphasis on excellence in teaching, research, and community service.
Lower Extremity Limb Salvage with Cross Leg Pedicle Flap, Cross Leg Free Flap, and Cross Leg Vascular Cable Bridge Flap
Manrique, Oscar J. , Bishop, Sarah N. , Ciudad, Pedro , Adabi, Kian , Martinez‐Jorge, Jorys, Moran, Steven L. , Huang, Tony Chieh‐Ting , Vijayasekaran, Aparna , Huang, Tony, Huang, Tony C T , Chen, Shih‐Heng , Chen, Hung‐Chi

Journal of Reconstructive Microsurgery | May 16, 2018 | Volume: 34 | Issue: 07 | Pages: 522-529

10.1055/s-0038-1641712 | PMID 29768632 Get It

Background Lower extremity salvage following significant soft tissue loss can be complicated by lack of recipient vessel for free tissue transfer. We describe our experience in lower limb salvage for patients with no recipient vessels with the use of pedicle, free and cable bridge flaps. Methods A retrospective review from 1985 to 2017 of patients undergoing lower limb salvage using a contralateral pedicle cross leg (PCL) flaps, free cross leg (FCL) flaps, or free cable bridge (FCB) flaps was conducted. Demographics, etiology of the reconstruction, type of flap used, donor-site vessels, defect size, operating time, time of pedicle division, length of hospital stay, time to ambulation, and complications were analyzed. Results A total of 53 patients (48 males and 5 females) with an average age of 35 years (range, 29–38 years) were identified. The etiology for the reconstruction was trauma in 52 patients and oncological resection in 1 patient. There were 18 PCL, 25 FCL, and 10 FCB completed. The recipient vessels for all flaps were the posterior tibial artery and vein. The average operating room times for PCL, FCL, and FCB flaps were 4, 9, and 10 hours, respectively. The average length of hospital stay was 5 weeks and average time to ambulation was 4 weeks. The average follow-up time was 7.5 years (range, 3–12 years). Complications encountered were hematoma (six), prolonged pain (six), total flap loss (two), reoperation (five), and infection (four). Limb salvage rates were 96.2%. Conclusion When ipsilateral limb vessels are not available, and other reconstructive options have been exhausted, cross leg flaps can be a viable option for limb salvage in the setting of extensive defects.
Preoperative Analysis of Venous Anatomy Before Deep Inferior Epigastric Perforator Free-Flap Breast Reconstruction Using Ferumoxytol-enhanced Magnetic Resonance Angiography
Dortch, John D. , Forte, Antonio J. , Bolan, Candice W. , Kandel, Pujan , Bolan, Candice, Forte, Antonio Jorge , Perdikis, Galen

Annals of Plastic Surgery | May 15, 2018 | Volume: 90 | Issue: 4 | Pages: 343-348

10.1097/sap.0000000000001421 | PMID 29762436 Get It

Background Venous congestion after deep inferior epigastric artery perforator (DIEP) flap breast reconstruction is a complication that may be partially attributable to variations in venous abdominal wall anatomy. In previous work, we have shown that ferumoxytol may be used as a bloodpool contrast agent to perform high-resolution venous imaging. Our current aim was to use this technology to perform a detailed analysis of the venous anatomy among patients undergoing DIEP flap breast reconstruction. Methods All patients undergoing DIEP flap reconstruction with preoperative ferumoxytol-enhanced magnetic resonance angiography (FE-MRA) were retrospectively reviewed. A detailed anatomic analysis of each abdominal wall on FE-MRAwas performed before review of operative findings. Statistical analysis was used to determine venous characteristics associated with superficial inferior epigastric vein (SIEV) augmentation. Results From 2012 to 2016, 59 patients underwent preoperative FE-MRA. This resulted in imaging for 118 hemiabdomen and 99 flaps. Superficial-deep communication was identified in 117 of 118 hemiabdomen. Fifty (93%) of 59 patients had greater than 1-mm venous communication of the superficial system across midline. Reconstructed breasts were based on dominant medial row perforators in 82 (83%) of 99 flaps. The mean diameters of the SIEVand dominant venous perforator were 3.8 and 2.8mm, respectively. Anatomic characteristics associated with SIEVaugmentation included SIEVdiameter ( P = 0.01), dominant perforator diameter ( P = 0.04), and the ratio between these 2 variables ( P = 0.001). Conclusions Ferumoxytol-enhanced magnetic resonance angiography provides excellent imaging of the venous system. Anatomic characteristics such as the diameter of the SIEVand the diameter of the dominant perforator may be useful in determining which flaps require venous augmentation using the SIEV.
Abstract 77: Outcomes Analysis of Goldilocks Mastectomy and Breast Reconstruction: The Mayo Clinic Experience
Oliver, Jeremie D. , Chaudhry, Arif, Alsubaie, Saad, Martinez‐Jorge, Jorys, Oliver, Jeremie D

Plastic and Reconstructive Surgery - Global Open | May 5, 2018 | Volume: 6 | Issue: 4S | Pages: 61-62

10.1097/01.gox.0000533942.85741.66 Get It

Abstract 112: Systematic Review and Meta Analysis of Complications and Patient Reported Outcomes in Male to Female Vaginoplasty- Where We Are Today
Manrique, Oscar J. , Adabi, Kian , Martinez‐Jorge, Jorys, Ciudad, Pedro , Wang, Zhen , Kiranantawat, Kidakorn , Wang, Zhen

Plastic and Reconstructive Surgery - Global Open | May 5, 2018 | Volume: 6 | Issue: 4S | Pages: 88-88

10.1097/01.gox.0000533977.85699.45 Get It

The DOT1L inhibitor pinometostat reduces H3K79 methylation and has modest clinical activity in adult acute leukemia
Stein, Eytan M. , Garcia‐Manero, Guillermo , Rizzieri, David A. , Tibes, Raoul , Jongen-Lavrenic, Mojca, Altman, Jessica K. , Thomson, Blythe, Blakemore, Stephen J. , Daigle, Scott R., Waters, Nigel J. , Suttle, A. Benjamin, Clawson, Alicia, Pollock, Roy M. , Krivtsov, Andrei V. , Armstrong, Scott A. , DiMartino, Jorge, Hedrick, Eric, Löwenberg, Bob , Tallman, Martin S. , Löwenberg, Bob , Berdeja, Jesús G. , Savona, Michael R.

Blood | May 3, 2018 | Volume: 131 | Issue: 24 | Pages: 2661-2669

10.1182/blood-2017-12-818948 | PMID 29724899 Get It

Key Points Pinometostat demonstrates first evidence of DOT1L target inhibition and clinical responses in a subset of MLL-r advanced leukemia patients. The observed safety profile of pinometostat shows potential for exploration of combination therapies in leukemia.
Parametric phantom study of shear wave velocity image reconstruction
Racedo, Jorge , Urban, Matthew W.

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035899 Get It

Shear wave elastography is being increasingly used for multiple applications including investigation of diffuse disease in the liver or kidney and malignancies or neoplasms in the breast and thyroid. It is important to provide robust and accurate reconstructions of shear wave velocity (SWV) for imaging purposes to provide reliable data for diagnosis. One such approach was a two-dimensional method for estimating SWV (Song, et al., Ultrasound Med. Biol. 40, pp. 1343–1355, 2014). This method uses a weighted average using a large window and smaller patches to perform time-domain cross-correlations for the calculation of the SWV. We also implemented a spatial sigmoid weighting to combine reconstruction results from independent reconstructions after directional filtering. We used a Verasonics system equipped with a linear array transducer to conduct a parametric study in phantoms to investigate the effects of the window and patch on image reconstruction metrics. Measurements were made in homogeneous phantoms and in a phantom with cylindrical inclusions of different diameters. Larger windows and patches typically yielded low variability but did not always produce the highest contrast. This investigation is the basis for an adaptive method for reconstructing SWV in soft tissues and choosing optimal parameters for the SWV reconstruction.
Metabolic coupling of axons and glial cells
Benarroch, Eduardo E. , Correale, Jorge, Ysrraelit, María C, Correale, Jorge Daniel , Ysrraelit, María Célica

Neurology | April 16, 2018 | Volume: 90 | Issue: 16 | Pages: 737-744

10.1212/wnl.0000000000005339 | PMID 29661892 Get It