Citations

Mayo Clinic

Clear

1172 citation(s) found for "Ma, Cynthia".

P1‐325: Predicting Progression to Mild Cognitive Impairment in Cognitively Unimpaired Individuals Using Neuroimaging Biomarkers
Stonnington, Cynthia M. , Lee, Wendy , Bauer, Robert, Sharieff, Sameen, Chen, Yinghua , Caselli, Richard J. , Reiman, Eric M. , Locke, Dona E.C. , Chen, Kewei

Alzheimer's & Dementia | October 17, 2016 | Volume: 12 | Issue: 7S_Part_11 | Pages: No page available

10.1016/j.jalz.2016.06.1076 Get It

P1‐391: MRI Predictors of Cognitive Decline in CKD: The Brink Study
Murray, Anne M. , Davey, Cynthia , Tupper, David E., Amiot, Elizabeth, Zuk, Samantha M., Steinert, Kaely, Vemuri, Prashanthi , Lundt, Emily S. , Jack, Clifford R.

Alzheimer's & Dementia | October 17, 2016 | Volume: 12 | Issue: 7S_Part_12 | Pages: No page available

10.1016/j.jalz.2016.06.1143 Get It

P3‐285: Patch‐Based Sparse Coding and Multivariate Surface Morphometry for Predicting Amnestic Mild Cognitive Impairment and Alzheimer’S Disease in Cognitively Unimpaired Individuals
Zhang, Jie , Li, Qingyang , Bauer, Robert, Reiman, Eric M. , Caselli, Richard J. , Stonnington, Cynthia M. , Wang, Yalin , Shi, Jie , Chen, Kewei

Alzheimer's & Dementia | October 17, 2016 | Volume: 12 | Issue: 7S_Part_19 | Pages: No page available

10.1016/j.jalz.2016.06.1939 Get It

Oral Vancomycin Therapy in a Child with Primary Sclerosing Cholangitis and Severe Ulcerative Colitis
Buness, Cynthia W. , Lindor, Keith D. , Miloh, Tamir

Pediatric Gastroenterology, Hepatology & Nutrition | October 13, 2016 | Volume: 19 | Issue: 3 | Pages: 210

10.5223/pghn.2016.19.3.210 | PMID 27738604 Get It

Arterial wall perfusion measured with photon counting spectral x-ray CT
Jorgensen, Steven M., Korinek, Mark J., Vercnocke, Andrew J. , Anderson, Jill , Halaweish, Ahmed F., Ritman, Erik L., Anderson, Jill L, Korinek, Mark, Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | October 4, 2016 | Volume: 9967 | Issue: No issue available | Pages: 99670B

10.1117/12.2238817 | PMID 27807391 Get It

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector
Jorgensen, Steven M., Vercnocke, Andrew J. , Rundle, David S., Butler, Philip H. , Ritman, Erik L., McCollough, Cynthia H.

SPIE Proceedings | October 3, 2016 | Volume: 9969 | Issue: No issue available | Pages: 99690J

10.1117/12.2236501 | PMID 27795606 Get It

A resilience intervention involving mindfulness training for transplant patients and their caregivers
Stonnington, Cynthia M. , Darby, Betty, Santucci, Angela , Mulligan, Pamela C., Pathuis, Patricia, Cuc, Andrea , Hentz, Joseph G. , Zhang, Nan , Mulligan, David C. , Sood, Amit

Clinical Transplantation | September 12, 2016 | Volume: 30 | Issue: 11 | Pages: 1466-1472

10.1111/ctr.12841 | PMID 27618687 Get It

Abstract Solid organ and stem cell transplant patients and their caregivers report a substantial level of distress. Mindfulness‐based stress reduction has been shown to alleviate distress associated with transplant, but there is limited experience in this population with other mindfulness‐based interventions, or with combined transplant patient and caregiver interventions. We evaluated a novel, 6‐week mindfulness‐based resilience training ( MBRT ) class for transplant patients and their caregivers that incorporates mindfulness practice, yoga, and neuroscience of stress and resilience. Thirty‐one heart, liver, kidney/pancreas, and stem cell transplant patients and 18 caregivers at Mayo Clinic in Arizona participated. Measures of stress, resilience, depression, anxiety, health‐related quality of life, positive and negative affect, and sleep were completed at baseline, 6 weeks, and 3 months postintervention. At 6 weeks and 3 months, patients demonstrated significant ( P <.005) improvements from baseline in measures of perceived stress, depression, anxiety, and negative affect. Quality‐of‐life mental component ( P =.006) and positive affect ( P =.02) also improved at follow‐up. Most participants adhered to the program, were satisfied with class length and frequency, and reported improved well‐being as a result of the class. MBRT holds promise as an intervention to enhance resilience and manage stress for transplant patients and their caregivers.
Clinical Spectrum of Medium‐Sized Vessel Vasculitis
Alıbaz-Öner, Fatma , Crowson, Cynthia S. , Makol, Ashima , Ytterberg, Steven R. , Matteson, Eric L. , Warrington, Kenneth J. , Koster, Matthew J. , Salvarani, Carlo , Warrington, Kenneth J , Makol, Ashima

Arthritis Care & Research | August 26, 2016 | Volume: 69 | Issue: 6 | Pages: 884-891

10.1002/acr.23007 | PMID 27564269 Get It

ObjectivePolyarteritis nodosa (PAN) is a systemic necrotizing vasculitis of medium‐sized visceral vessels. However, cutaneous arteritis (CA) and gastrointestinal (GI) vasculitis are forms of single‐organ vasculitis having indistinguishable histopathologic findings from PAN. The aim of this study was to evaluate and compare the clinical characteristics, treatment, and outcomes of patients with systemic PAN, CA, and GI vasculitis.MethodsRetrospective cohorts were assembled, consisting of patients with PAN, CA, and GI vasculitis between 1980 and 2014. The demographics, clinical characteristics, treatment, and outcomes of patients were abstracted from medical records.ResultsWe included 48 patients with PAN, 41 patients with CA, and 19 patients with GI vasculitis. The disease of 1 patient evolved from CA to systemic PAN during the disease course. At diagnosis, 94% of patients with PAN, 93% of patients with CA, and 67% of patients with GI vasculitis were treated with glucocorticoids. Additional immunosuppressive agents were used in 67% of PAN, 37% of GI vasculitis, and 32% of CA cases. The 5‐year cumulative relapse rate was 45.2% in CA, and only 9.6% in PAN during a followup of approximately 6 years. No deaths were observed in the CA group. The survival rate at 10 years was 66% in the PAN group and 61% in the GI vasculitis group.ConclusionSystemic PAN, CA, and GI vasculitis take different clinical courses and therefore may be different diseases, rather than existing on a spectrum of the same disease. Progression of CA to systemic PAN is very rare. Relapse risk is low during followup in PAN. Patients with CA have a higher relapse rate than those with systemic PAN, possibly due to less use of immunosuppressive therapy in CA.
Association between Participation in an Intensive Longitudinal Assessment Program and Performance on a Cognitive Examination in the Maintenance of Certification in Anesthesiology Program®
Culley, Deborah J. , Lien, Cynthia A. , Harman, Ann E., Sun, Huaping , Sun, Huaping , Zhou, Yan , Warner, David O.

Anesthesiology | August 24, 2016 | Volume: 125 | Issue: 5 | Pages: 1046-1055

10.1097/aln.0000000000001301 | PMID 27560464 Get It

Abstract Background As part of the Maintenance of Certification in Anesthesiology Program® (MOCA®), the American Board of Anesthesiology (Raleigh, North Carolina) developed the MOCA Minute program, a web-based intensive longitudinal assessment involving weekly questions with immediate feedback and links to learning resources. This observational study tested the hypothesis that individuals who participate in the MOCA Minute program perform better on the MOCA Cognitive Examination (CE) compared with those who do not participate. Methods Two separate cohorts of individuals eligible for July 2014 and January 2015 CEs were invited to participate in this pilot. The CE scores for each cohort were compared between those who did and did not participate, controlling for the factors known to affect performance. For the first cohort, examination performances for topics covered and not covered by the MOCA Minute were analyzed separately. Results Six hundred sixteen diplomates in July 2014 and 684 diplomates in January 2015 took the CE for the first time. In multiple regression analysis, those actively participating scored 9.9 points (95% CI, 0.8 to 18.9) and 9.3 points (95% CI, 2.3 to 16.3) higher when compared with those not enrolled, respectively. Compared to the group that did not enroll in MOCA Minute, those who enrolled but did not actively participate demonstrated no improvement in scores. MOCA Minute participation was associated with improvement in both questions covering topics included the MOCA Minute and questions not covering these topics. Conclusions This analysis provides evidence that voluntary active participation in a program featuring frequent knowledge assessments accompanied by targeted learning resources is associated with improved performance on a high-stakes CE.
Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography
Yu, Zhicong , Li, Zhoubo , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 23, 2016 | Volume: 61 | Issue: 18 | Pages: 6707-6732

10.1088/0031-9155/61/18/6707 | PMID 27551878 Get It

Abstract Photon-counting computed tomography (PCCT) is an emerging imaging technique that enables multi-energy imaging with only a single scan acquisition. To enable multi-energy imaging, the detected photons corresponding to the full x-ray spectrum are divided into several subgroups of bin data that correspond to narrower energy windows. Consequently, noise in each energy bin increases compared to the full-spectrum data. This work proposes an iterative reconstruction algorithm for noise suppression in the narrower energy bins used in PCCT imaging. The algorithm is based on the framework of prior image constrained compressed sensing (PICCS) and is called spectral PICCS; it uses the full-spectrum image reconstructed using conventional filtered back-projection as the prior image. The spectral PICCS algorithm is implemented using a constrained optimization scheme with adaptive iterative step sizes such that only two tuning parameters are required in most cases. The algorithm was first evaluated using computer simulations, and then validated by both physical phantoms and in vivo swine studies using a research PCCT system. Results from both computer-simulation and experimental studies showed substantial image noise reduction in narrow energy bins (43–73%) without sacrificing CT number accuracy or spatial resolution.