Citations

Mayo Clinic

Showing 10 of 108551 citations.

Faculty Opinions recommendation of Three-dimensional Technology Facilitates Surgical Performance of Novice Laparoscopy Surgeons: A Quantitative Assessment on a Porcine Kidney Model.
Humphreys, Mitchell R.

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | April 11, 2016 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.726275526.793516592 Get It

Faculty Opinions recommendation of An experimental study about haptic feedback in robotic surgery: may visual feedback substitute tactile feedback?
Humphreys, Mitchell R.

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | April 11, 2016 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.725932882.793516591 Get It

Impact of Simple Ovarian Cysts on the Interpretation of Endometrial Thickness in Women with Postmenopausal Bleeding
Famuyide, Abimbola O. , Makdisi, Peter B., El‐Nashar, Sherif A. , Breitkopf, Daniel M. , Hopkins, Matthew R. , Laughlin-Tommaso, Shannon K., Shazly, Sherif A M, El-Nashar, Sherif A, Shazly, Sherif A.

Journal of Women's Health | April 11, 2016 | Volume: 25 | Issue: 9 | Pages: 889-896

10.1089/jwh.2015.5644 | PMID 27064534 Get It

Rapid in vivo measurement of β-amyloid reveals biphasic clearance kinetics in an Alzheimer’s mouse model
Yuede, Carla M. , Restivo, Jessica L., Davis, Todd A. , Hettinger, Jane C., Wallace, Clare E. , Young, Katherine L., Hayne, Margaret, Bu, Guojun , Li, Chen-Zhong, Cirrito, John R. , Lee, Hyo Jin , Bu, Guojun

Journal of Experimental Medicine | April 11, 2016 | Volume: 213 | Issue: 5 | Pages: 677-685

10.1084/jem.20151428 | PMID 27069115 Get It

Findings from genetic, animal model, and human studies support the observation that accumulation of the β-amyloid (Aβ) peptide in the brain plays a central role in the pathogenic cascade of Alzheimer’s disease (AD). Human studies suggest that one key factor leading to accumulation is a defect in brain Aβ clearance. We have developed a novel microimmunoelectrode (MIE) to study the kinetics of Aβ clearance using an electrochemical approach. This is the first study using MIEs in vivo to measure rapid changes in Aβ levels in the brains of living mice. Extracellular, interstitial fluid (ISF) Aβ levels were measured in the hippocampus of APP/PS1 mice. Baseline levels of Aβ40 in the ISF are relatively stable and begin to decline within minutes of blocking Aβ production with a γ-secretase inhibitor. Pretreatment with a P-glycoprotein inhibitor, which blocks blood–brain barrier transport of Aβ, resulted in significant prolongation of Aβ40 half-life, but only in the latter phase of Aβ clearance from the ISF.
Percutaneous Cryoablation of Extraabdominal Desmoid Tumors: A 10-Year Experience
Schmitz, John J. , Schmit, Grant D. , Atwell, Thomas D. , Callstrom, Matthew R. , Weisbrod, Adam J. , Kurup, Anil N, Kurup, A. Nicholas , Morris, Jonathan M.

American Journal of Roentgenology | April 11, 2016 | Volume: 207 | Issue: 1 | Pages: 190-195

10.2214/ajr.15.14391 | PMID 27064168 Get It

Langerhan's Cell Sarcoma: Two Case Reports
Kaleem, Tasneem , Schild, Michael H. , Jha, Asit, Cortese, Cherise , Attia, Steven , Miller, Robert C. , Kaleem, Tasneem A, Miller, Daniel , Miller, Daniel

Rare Tumors | April 11, 2016 | Volume: 8 | Issue: 1 | Pages: 17-19

10.4081/rt.2016.6140 | PMID 27134713 Get It

Langerhan's cell sarcoma (LCS) is a rare neoplasm with a poor prognosis. To our knowledge, only sixty-six cases have been published. We discuss two patients who presented very differently with LCS, as well as a recently published review of all sixty-six cases. Our first case had a complicated history of metastatic, high-grade myxofibrosarcomas and presented with a single skin lesion of LCS which was treated with resection to a positive margin and adjuvant radiotherapy. The LCS recurred locoregionally and was again resected. The patient is alive two years after initial diagnosis. The second case presented with bone marrow and splenic involvement, leukocytosis, and thrombocytopenia. This patient had an excellent response to etoposide, prednisone, oncovorin, cyclophosphamide, and adriamycin, with normalization of the complete blood count, negative bone marrow biopsy at follow up, and splenectomy without viable neoplasm. This patient is alive without signs of disease at 16 months after initial diagnosis.
Poststernotomy Osteomyelitis Presenting with Severe Sepsis and Rhabdomyolysis
Tan, Eugene M. , Lyle, Melissa , Temesgen, Zelalem , Cawcutt, Kelly , Tan, E M

Case Reports in Medicine | April 10, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-3

10.1155/2016/4507012 | PMID 27143974 Get It

A 39-year-old male, who recently underwent a composite valve graft of the aortic root and ascending aorta for bicuspid aortic valve and aortic root aneurysm, was hospitalized for severe sepsis, rhabdomyolysis (creatine kinase 29000 U/L), and severe liver dysfunction (AST > 7000 U/L, ALT 4228 U/L, and INR > 10). Cardiac magnetic resonance imaging (MRI) findings were consistent with sternal osteomyelitis with a 1.5 cm abscess at the inferior sternotomy margin, which was contiguous with pericardial thickening. Aspiration and culture of this abscess did not yield any organisms, so he was treated with vancomycin and cefepime empirically for 4 weeks. Because this patient was improving clinically on antibiotics and did not show external signs of wound infection, there was no compelling indication for sternectomy. This patient’s unusual presentation with osteomyelitis and rhabdomyolysis has never been reported and is crucial for clinicians to recognize in order to prevent delays in diagnosis.
Vascular specialist response to Medicare Evidence Development Coverage Advisory Committee (MEDCAC) panel on peripheral artery disease of the lower extremities
Shishehbor, Mehdi H. , Bartholomew, John R. , Beckman, Joshua A. , Froehlich, James B. , Lookstein, R. , Roberts, Anne C. , Misra, Sanjay , Aronow, Herbert D. , Misra, Sanjay, Rosenfield, Kenneth , Jaff, Michael R. , Misra, Sanjay , Beckman, Joshua A

Vascular Medicine | April 10, 2016 | Volume: 21 | Issue: 3 | Pages: 281-286

10.1177/1358863x16636955 | PMID 27063017 Get It

Vascular specialist response to medicare evidence development coverage advisory committee (MEDCAC) panel on peripheral artery disease of the lower extremities
Shishehbor, Mehdi H. , Bartholomew, John R. , Beckman, Joshua A. , Froehlich, James B. , Lookstein, R. , Roberts, Anne C. , Misra, Sanjay , Aronow, Herbert D. , Misra, Sanjay, Rosenfield, Kenneth , Jaff, Michael R. , Misra, Sanjay , Beckman, Joshua A

Catheterization and Cardiovascular Interventions | April 10, 2016 | Volume: 87 | Issue: 7 | Pages: 1181-1186

10.1002/ccd.26512 | PMID 27062192 Get It

Determinants and clinical impact of pressure drift in manoscan anorectal high resolution manometry system
Parthasarathy, Gopanandan , McMaster, Jordan, Feuerhak, Kelly, Zinsmeister, A. R., Bharucha, Adil E.

Neurogastroenterology & Motility | April 10, 2016 | Volume: 28 | Issue: 9 | Pages: 1433-1437

10.1111/nmo.12830 | PMID 27061208 Get It

AbstractBackgroundPressure drift (PD), resulting from differences between room and body temperature, reduces the accuracy of pressure measurements with the Manoscan high resolution manometry (HRM) system. Our aims were to assess PD during anorectal HRM.MethodsDefined as the residual pressure measured immediately after the catheter was removed, PD was calculated for each sensor and averaged across all 12 sensors in 454 anorectal consecutive studies recorded with 3 HRM catheters. The relationship between PD and study duration, number of prior uses of a catheter, and peak and average pressure exposure during a study were evaluated. The correction of PD with a software algorithm (thermal compensation) was evaluated in 76 studies where the most distal sensor was outside the body.Key ResultsThe PD varied among sensors and across catheters. The average PD (7.3 ± 0.2 mmHg) was significantly greater for newer catheters, during longer studies, or when sensors were exposed to higher pressures. Together, these factors explained 81% of the variance in overall PD. After thermal compensation, the uncorrected median PD for the most distal sensor was 2.5–5 mmHg over the study duration. Correcting this changed the interpretation (e.g., as abnormal instead of normal) of at least 1 anorectal parameter in eight of 76 studies.Conclusions & InferencesDuring anorectal HRM, PD declines with catheter use and is greater for newer catheters, when sensors are exposed to higher pressures, and for studies of longer duration. While PD is partially corrected with thermal compensation algorithms, the impact on interpretation is modest.