Citations

Mayo Clinic

Showing 10 of 108602 citations.

Effect of acute renal decapsulation on pressure natriuresis in SHR and WKY rats
Khraibi, Ali A. , Knox, Franklyn G.

American Journal of Physiology-Renal Physiology | December 22, 2017 | Volume: 257 | Issue: 5 | Pages: F785-F789

10.1152/ajprenal.1989.257.5.f785 | PMID 2589482 Get It

The objective of these experiments was to study pressure natriuresis in the Wistar-Kyoto (WKY) and the spontaneously hypertensive rat (SHR) during acute bilateral renal decapsulation, a maneuver that partially blocks the increase in renal interstitial hydrostatic pressure (RIHP). In control WKY rats (n = 7), at renal perfusion pressure (RPP) of 105 +/- 0.7 and 125 +/- 1.1 mmHg, RIHP increased from 4.4 +/- 0.4 to 7.2 +/- 0.7 mmHg (P less than 0.05) and fractional excretion of sodium (FENa) increased from 0.23 +/- 0.05 to 1.32 +/- 0.14% (P less than 0.05). Acute bilateral renal decapsulation (n = 6) blunted the increase in RIHP observed when RPP was increased in control WKY rats and abolished the pressure natriuretic and diuretic response. When RPP was allowed to increase from 106 +/- 0.8 to 130 +/- 2.2 mmHg in the WKY rats with decapsulated kidneys, RIHP increased from 3.8 +/- 0.5 to 4.3 +/- 0.4 mmHg but FENa did not significantly change (0.31 +/- 0.12 to 0.43 +/- 0.13%). In control SHRs (n = 7), at RPPs of 135 +/- 0.8 and 163 +/- 3.0 mmHg, RIHP was 4.4 +/- 0.4 and 5.0 +/- 0.6 mmHg (NS) and FENa was 0.41 +/- 0.10 and 0.82 +/- 0.17% (P less than 0.05). Renal decapsulation in the SHR did not affect the blunted relationships between RPP, RIHP, and FENa; at RPPs of 135 +/- 0.3 and 162 +/- 2.9 mmHg (n = 7), RIHP was 4.4 +/- 0.6 and 4.7 +/- 0.5 mmHg (NS) and FENa was 0.43 +/- 0.10 and 0.95 +/- 0.22% (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
Validation of a new live cell strain system: characterization of plasma membrane stress failure
Stroetz, Randolph W., Vlahakis, Nicholas E., Walters, Bruce J., Hubmayr, Rolf D., Schroeder, Mark A.

Journal of Applied Physiology | December 22, 2017 | Volume: 90 | Issue: 6 | Pages: 2361-2370

10.1152/jappl.2001.90.6.2361 | PMID 11356803 Get It

Motivated by our interest in lung deformation injury, we report on the validation of a new live cell strain system. We showed that the system maintains a cell culture environment equivalent to that provided by conventional incubators and that its strain ouput was uniform and reproducible. With this system, we defined cell deformation dose (i.e., membrane strain amplitude)-cell injury response relationships in alveolar epithelial cultures and studied the effects of temperature on them. Deformation injury occurred in the form of reversible, nonlethal plasma membrane stress failure events and was quantified as the fraction of cells with uptake and retention of fluorescein-labeled dextran (FITC-Dx). The undeformed control population showed virtually no FITC-Dx uptake at any temperature, which was also true for cells strained by 3%. However, when the membrane strain was increased to 18%, ∼5% of cells experienced deformation injury at a temperature of 37°C. Moreover, at that strain, a reduction in temperature to 4°C resulted in a threefold increase in the number of cells with plasma membrane breaks (from 4.8 to 15.9%; P < 0.05). Cooling of cells to 4°C also lowered the strain threshold at which deformation injury was first seen. That is, at a 9% substratum strain, cooling to 4°C resulted in a 10-fold increase in the number of cells with FITC-Dx staining (0.7 vs. 7.5%, P < 0.05). At that temperature, A549 cells offered a 50% higher resistance to shape change (magnetic twisting cytometry measurements) than at 37°C. We conclude that the strain-injury threshold of A549 cells is reduced at low temperatures, and we consider temperature effects on plasma-membrane fluidity, cytoskeletal stiffness, and lipid trafficking as responsible mechanisms.
Reduced submaximal leg blood flow after high-intensity aerobic training
Dietz, Niki M., Minson, Christopher T. , Proctor, David N. , Miller, Jordan D. , Joyner, Michael J.

Journal of Applied Physiology | December 22, 2017 | Volume: 91 | Issue: 6 | Pages: 2619-2627

10.1152/jappl.2001.91.6.2619 | PMID 11717227 Get It

This study evaluated the hypothesis that active muscle blood flow is lower during exercise at a given submaximal power output after aerobic conditioning as a result of unchanged cardiac output and blunted splanchnic vasoconstriction. Eight untrained subjects (4 men, 4 women, 23–31 yr) performed high-intensity aerobic training for 9–12 wk. Leg blood flow (femoral vein thermodilution), splanchnic blood flow (indocyanine green clearance), cardiac output (acetylene rebreathing), whole body O2 uptake (V˙o 2), and arterial-venous blood gases were measured before and after training at identical submaximal power outputs (70 and 140 W; upright 2-leg cycling). Training increased ( P < 0.05) peak V˙o 2(12–36%) but did not significantly change submaximalV˙o 2 or cardiac output. Leg blood flow during both submaximal power outputs averaged 18% lower after training ( P = 0.001; n = 7), but these reductions were not correlated with changes in splanchnic vasoconstriction. Submaximal leg V˙o 2 was also lower after training. These findings support the hypothesis that aerobic training reduces active muscle blood flow at a given submaximal power output. However, changes in leg and splanchnic blood flow resulting from high-intensity training may not be causally linked.
Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry
Levine, James A. , Abboud, Lana, Barry, Mitchel, Reed, Judd E., Sheedy, Patrick F. , Jensen, Michael D.

Journal of Applied Physiology | December 22, 2017 | Volume: 88 | Issue: 2 | Pages: 452-456

10.1152/jappl.2000.88.2.452 | PMID 10658010 Get It

Dual-energy X-ray absorptiometry (DEXA) is reported to be inferior to computed tomography (CT) to measure changes in appendicular soft tissue composition. We compared CT- and DEXA-measured thigh muscle and fat mass to evaluate the random and systematic discrepancies between these two methods. Thigh skeletal muscle area (single-slice CT) was suboptimally ( r2= 0.74, P < 0.0001) related to DEXA-measured thigh fat-free mass (FFM). In contrast, thigh muscle and adipose tissue volumes (multislice CT) were highly related to DEXA-measured thigh FFM and fat (both r2= 0.96, P < 0.0001). DEXA-measured leg fat was significantly less than multislice-CT-measured leg adipose tissue volume, whereas multislice-CT-measured leg muscle mass was less ( P < 0.0001) than DEXA-measured leg FFM. The systematic discrepancies between the two approaches were consistent with the 10–15% nonfat components of adipose tissue. In conclusion, CT and DEXA measures of appendicular soft tissue are highly related. Systematic differences between DEXA and CT likely relate to the underlying principles of the techniques.
Commentary
Sieck, Gary C.

Journal of Applied Physiology | December 22, 2017 | Volume: 88 | Issue: 1 | Pages: 344-345

10.1152/jappl.2000.88.1.344 Get It

Leg mass and lower body negative pressure tolerance in men and women
Lawler, Lori A., Halliwill, John R. , Summer, Jolene M., Joyner, Michael J. , Mulvagh, Sharon L.

Journal of Applied Physiology | December 22, 2017 | Volume: 85 | Issue: 4 | Pages: 1471-1475

10.1152/jappl.1998.85.4.1471 | PMID 9760343 Get It

To explore the hypothesis that lower body muscle mass correlates with orthostatic tolerance, 18 healthy volunteers (age 18–48 yr; 10 men, 8 women) underwent a graded lower body negative pressure (LBNP) protocol consisting of six, 5-min stages of suction up to 60 mmHg in 10-mmHg increments. Forearm blood flow, heart rate, and blood pressure were measured, and forearm vascular resistance was calculated. Leg muscle mass was assessed by dual-energy X-ray absorptiometry. All subjects received standard intravenous hydration for at least 8 h before the study. Six men and four women completed all stages of LBNP. Four men and four women developed presyncopal symptoms, including marked bradycardia and/or hypotension, at LBNP levels of 30 mmHg ( n = 2; 1 man, 1 woman), 40 mmHg ( n = 2; 1 man, 1 woman), and 50 mmHg ( n = 4; 2 men, 2 women). The presyncopal subjects had leg muscle masses ranging from 19.5 to 25.2 kg in men and from 11.7 to 16.6 kg in women. In subjects who completed all stages of LBNP, leg muscle mass ranged from 17.5 to 24.1 kg in men and from 10.4 to 18.0 kg in women. Leg muscle mass did not differ between presyncopal subjects and those who completed the protocol. Furthermore, there were no differences in the hemodynamic responses to LBNP between subjects with low vs. high leg mass. These data suggest that leg muscle mass is not a critical determinant of LBNP tolerance in otherwise healthy men and women.
Supplements to Help Prevent Neuropathy During Chemotherapy? A Cautionary Tale
Giridhar, Karthik V. , Viscuse, Paul V. , Loprinzi, Charles L. , Ruddy, Kathryn J. , Giridhar, Karthik V

JNCI: Journal of the National Cancer Institute | December 22, 2017 | Volume: 110 | Issue: 6 | Pages: 551-552

10.1093/jnci/djx294 | PMID 29361012 Get It

Measurement of limb venous compliance in humans: technical considerations and physiological findings
Halliwill, John R. , Minson, Christopher T. , Joyner, Michael J.

Journal of Applied Physiology | December 22, 2017 | Volume: 87 | Issue: 4 | Pages: 1555-1563

10.1152/jappl.1999.87.4.1555 | PMID 10517791 Get It

We conducted a series of studies to develop and test a rapid, noninvasive method to measure limb venous compliance in humans. First, we measured forearm volume (mercury-in-Silastic strain gauges) and antecubital intravenous pressure during inflation of a venous collecting cuff around the upper arm. Intravenous pressure fit the regression line, −0.3 ± 0.7 + 0.95 ± 0.02 ⋅ cuff pressure ( r = 0.99 ± 0.00), indicating cuff pressure is a good index of intravenous pressure. In subsequent studies, we measured forearm and calf venous compliance by inflating the venous collecting cuff to 60 mmHg for 4 min, then decreasing cuff pressure at 1 mmHg/s (over 1 min) to 0 mmHg, using cuff pressure as an estimate of venous pressure. This method produced pressure-volume curves fitting the quadratic regression (Δlimb volume) = β0 + β1 ⋅ (cuff pressure) + β2 ⋅ (cuff pressure)2, where Δ is change. Curves generated with this method were reproducible from day to day (coefficient of variation: 4.9%). In 11 subjects we measured venous compliance via this method under two conditions: with and without (in random order) superimposed sympathetic activation (ischemic handgrip exercise to fatigue followed by postexercise ischemia). Calf and forearm compliance did not differ between control and sympathetic activation ( P > 0.05); however, the data suggest that unstressed volume was reduced by the maneuver. These studies demonstrate that venous pressure-volume curves can be generated both rapidly and noninvasively with this technique. Furthermore, the results suggest that although whole-limb venous compliance is under negligible sympathetic control in humans, unstressed volume can be affected by the sympathetic nervous system.
Measurement of the components of nonexercise activity thermogenesis
Levine, James A. , Westerterp, Klaas R. , Melanson, Edward L. , Hill, James O.

American Journal of Physiology-Endocrinology and Metabolism | December 22, 2017 | Volume: 281 | Issue: 4 | Pages: E670-E675

10.1152/ajpendo.2001.281.4.e670 | PMID 11551842 Get It

Nonexercise activity thermogenesis (NEAT) accounts for the vast majority of nonresting metabolic rate and changes in NEAT-predicted susceptibility to fat gain with overfeeding. Measuring physical activity and its components in free-living humans has been a long-standing challenge. In this study, we combine information about lightweight sensors that capture data on body position and motion with laboratory measures of energy expenditure to calculate nonfidgeting NEAT. This measurement of nonfidgeting NEAT was compared with total NEAT measured in a room calorimeter in 11 healthy subjects. The measurement of nonfidgeting NEAT accounted for 85 ± 9% of total NEAT measured in the room calorimeter. The intraclass correlation coefficient for the two methods was 0.86 (95% confidence interval 0.56, 0.96; P < 0.05). This suggests that 86% of the variance is attributable to between-subject variance and 14% to between-method disagreement. These instruments are applicable to free-living subjects; they are stand-alone, are lightweight, and allow normal daily activities. This novel technology has potential application for not only assessing NEAT but also tracking physical activity in free-living humans.