Citations

Mayo Clinic

Showing 10 of 108629 citations.

Biomarkers for Early Detection of Acute Kidney Injury
Rizvi, Mahrukh, Rizvi, Mahrukh S, Kashani, Kianoush

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 3 | Pages: 386-399

10.1373/jalm.2017.023325 | PMID 33636842 Get It

AbstractBackgroundAcute kidney injury (AKI) is common in hospitalized patients and is associated with increased morbidity, mortality, and cost. Currently, AKI is diagnosed after symptoms manifest; available diagnostic tests (e.g., serum creatinine, urine microscopy, urine output) have limited ability to identify subclinical AKI. Because of the lack of treatment strategies, AKI typically is managed with supportive measures. However, strategies exist that may prevent renal insults in critically ill patients; therefore, early recognition of AKI is crucial for minimizing damage propagation.ContentExperimental and clinical studies have identified biomarkers that may facilitate earlier recognition of AKI or even identify patients at risk of AKI. Such biomarkers might aid in earlier implementation of preventive strategies to slow disease progression and potentially improve outcomes. This review describes some of the most promising novel biomarkers of AKI, including neutrophil gelatinase-associated lipocalin (NGAL), kidney injury molecule 1 (KIM-1), interleukin 18 (lL-18), liver-type fatty-acid-binding protein (L-FABP), insulin-like-growth-factor-binding protein 7 (IGFBP7), and tissue inhibitor of metalloproteinase 2 (TIMP-2).SummaryWe discuss biomarker test characteristics, their strengths and weaknesses, and future directions of their clinical implementation.
Therapeutic Monoclonal Antibodies in the Clinical Laboratory
Willrich, Maria Alice V. , Willrich, Maria Alice Vieira

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 3 | Pages: 454-457

10.1373/jalm.2016.022160 | PMID 33636855 Get It

Transforming Laboratory Utilization Review into Laboratory Stewardship: Guidelines by the PLUGS National Committee for Laboratory Stewardship
Dickerson, Jane A. , Fletcher, Andrew H, Procop, Gary W. , Keren, David F. , Singh, Ila , García, Joaquín J. , Carpenter, Robert B., Miles, Joe, Jackson, Brian R. , Astion, Michael L.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 2 | Pages: 259-268

10.1373/jalm.2017.023606 | PMID 32630981 Get It

Abstract Appropriate utilization of clinical laboratory services is important for patient care and requires institutional stewardship. Clinical laboratory stewardship programs are dedicated to improving the ordering, retrieval, and interpretation of appropriate laboratory tests. In addition, these programs focus on developing, maintaining, and improving systems to provide proper financial coverage for medically necessary testing. Overall, clinical laboratory stewardship programs help clinicians improve the quality of patient care while reducing costs to patients, hospitals, and health systems. This document, which was created by a new multiinstitutional committee interested in promoting and formalizing laboratory stewardship, summarizes core elements of successful hospital-based clinical laboratory stewardship programs. The core elements will also be helpful for independent commercial clinical laboratories.
Cyanide-Nitroprusside Colorimetric Assay: A Rapid Colorimetric Screen for Urinary Cystine
Brady, Clayton , Giesen, Callen D., Voskoboev, Nikolay, Chirackal, Robin S., Gavrilov, Dimitar K. , Flanagan, Ryan M, Brady, Clayton T , Lieske, John C.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 1 | Pages: 55-64

10.1373/jalm.2016.022582 | PMID 33636959 Get It

Abstract Background Cystinuria is an autosomal recessive disorder resulting in poor proximal tubule reabsorption of cystine in the nephron, increasing the risk of cystine stone formation. A fast, inexpensive assay to screen for urinary cystine is needed because cystine stones are difficult to noninvasively differentiate from more common calcium-containing ones. Tandem mass spectrometry (MS/MS) is sensitive and specific but is labor-intensive and costly. Alternatively, a colorimetric assay is fast and cost-effective; however, creatinine interference is an issue. Methods A published cyanide-nitroprusside colorimetric assay was modified for a high-throughput microplate format. Creatinine interference was reduced using 0.1 mol/L PBS and a standard reaction time of 60 s and was further corrected using a formula derived from the slope of multiple creatinine standard curves. Results The limit of blank was determined to be 2.6 mg/L, the limit of detection 11.9 mg/L, and the limit of quantitation 15.3 mg/L. The analytic measurement range was established as 15.3–100 mg/L cystine. Intraassay and interassay CV was calculated to be 9.6% and 8.0%, respectively, for a high-level cystine concentration (83.6 mg/L). Low-level cystine (36.4 mg/L) intraassay and interassay CV was determined to be 18.1% and 17.6%, respectively. Passing–Bablok regression analysis of colorimetric vs LC-MS/MS results revealed a slope of 1.10 and y intercept of −7.14 mg/L, with an overall bias of 2% by Bland–Altman plot analysis. Conclusions We analytically validated a rapid colorimetric assay suitable to quantify urinary cystine. The effect of thiol drugs on this assay remains to be determined.
FDA-Cleared versus Laboratory-Developed Tests: Why Start from Scratch When Kits Are Available?
Snozek, Christine L.H.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 1 | Pages: 130-131

10.1373/jalm.2016.021832 | PMID 33636963 Get It

Standardization of Minimal Residual Disease Testing in Multiple Myeloma
Baughn, Linda B. , Linden, Michael A.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 1 | Pages: 118-122

10.1373/jalm.2016.020883 | PMID 33636956 Get It

Antinuclear Antibody Screening: A Delicate Balance for Clinical Laboratories
Cotten, Steven W. , Snyder, Melissa R.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 6 | Pages: 609-612

10.1373/jalm.2017.023374 | PMID 33379812 Get It

Laboratory Utilization and Analytical Validation of Fecal Electrolyte Tests
Parakh, Rugvedita , Greene, Dina N. , Block, Darci R , Ranjitkar, Pratistha , Greene, Dina , Mathias, Patrick C

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 6 | Pages: 668-677

10.1373/jalm.2016.022590 | PMID 33379818 Get It

Abstract Background Chronic diarrhea can be categorized as fatty, watery, or inflammatory. Watery diarrhea is further divided into secretory or osmotic types and can be differentiated by measuring fecal electrolytes and osmotic gap. However, with widespread use of endoscopy, it is unclear if these measurements are being used clinically. Furthermore, because stool is not a validated specimen type for Food and Drug Administration–approved electrolyte assays, utilization is a practical concern for laboratories before analytical validation. Here, we determined the clinical utility and validated the performance characteristics of stool electrolytes on the Beckman Coulter AU680. Methods Historical results and literature review were used to determine the clinically relevant ranges for stool electrolytes (Na+, Cl−, K+, phosphate, and Mg2+). Additionally, medical chart review was performed (n = 44 patients) on results to evaluate their clinical utility in chronic diarrhea work-up. Linearity, precision, and stability studies were performed on the AU680. Accuracy was evaluated by comparing results to the Roche Cobas 6000 c501. Results For all cases, stool electrolytes and osmotic gap proved valuable in chronic diarrhea work-up. The imprecision of the assays ranged from 0% to 5.9%. All assays were found to be linear within the instrument's analytical measurement range with appropriate slopes and intercepts. The bias between the AU680 and the Roche c501 ranged from −0.48 to 2.39 (mmol/L or mg/dL). Na+, Cl−, and K+ were stable refrigerated for 5 days and up to 1 freeze-thaw cycle. Phosphate and Mg2+ were stable refrigerated for 48 h, but unstable to freeze-thaw cycles. Conclusions Stool osmotic gap is valuable for evaluating chronic diarrhea and can be calculated using electrolyte concentrations measured on the AU680.
Working With Your Practice to Ensure Appropriate Point-of-Care Usage
Karon, Brad S. , Donato, Leslie J.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 5 | Pages: 603-604

10.1373/jalm.2016.021774 | PMID 33379804 Get It

Spotlight on Laboratory Medicine: A Call for Reflections
Meeusen, Jeffrey W.

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 4 | Pages: 462-463

10.1373/jalm.2016.022087 | PMID 33636813 Get It