ABSTRACT Background Hospital at home (HaH) provides hospital‐level care at home as a substitute for brick‐and‐mortar hospital care. Multiple HaH studies demonstrate HaH provides safe, high‐quality, cost‐effective care. However, practices have varied approaches to delivering care and no HaH‐specific national standards exist. We aimed to develop national practice standards for HaH and assess practice performance against the standards. Methods The HaH Users Group (HaHUG), the national convener of HaH practices, assembled the Practice Standards Council in 2019 to develop evidence‐based standards for HaH. We reviewed existing international standards and the requirements of the Centers for Medicare and Medicaid Services Acute Hospital Care at Home Waiver. We engaged in multiple iterative rounds to develop domains and standards within each domain and then held an open comment period. We distributed an online survey for all HaHUG practices to self‐assess whether they did not meet (score, −1), met (score, 0), or exceeded (score, +1) each standard. The American Hospital Association's Annual Survey was used to describe practices that did and did not complete the practice standards survey. Results Final practice standards included 31 standards in 7 domains: leadership; education and training; human resources management; quality and quality improvement; safe practice and environment; and clinical standards and protocols. The majority of HaH practices self‐rated that they met or exceeded standards: scores ranged from −5 to 31; mean score of 9.75 (SD, 12.60). Forty‐nine of 213 eligible HaH practices completed the survey (response rate, 23.0%). Most hospitals were large (65% > 299 beds), nonprofit (85%), teaching (90%) centers that cared for a large proportion of patients with Medicaid. Conclusion We present the first national practice standards for HaH. The vast majority of HaH practices met or exceeded these standards by their own assessment. There was a range of performance across standards, demonstrating strengths and opportunities for ongoing development and quality improvement.
Smartphone Sensor Data May Enhance Real-World Depression Screening in Post-Stroke/TIA Patients (P1-13.008)
Artificial Intelligence–Based Classification of Renal Oncocytic Neoplasms: Advancing From a 2-Class Model of Renal Oncocytoma and Low-Grade Oncocytic Tumor to a 3-Class Model Including Chromophobe Renal Cell Carcinoma
Context.— Distinguishing between renal oncocytic tumors, such as renal oncocytoma (RO), and a subset of tumors with overlapping characteristics, including the recently identified low-grade oncocytic tumor (LOT), can present a diagnostic challenge for pathologists owing to shared histopathologic features. Objective.— To develop an automatic computational classifier for stratifying whole slide images of biopsy and resection specimens into 2 distinct groups: RO and LOT. Design.— A total of 269 whole slide images from 125 cases across 6 institutions were collected. A weakly supervised attention-based multiple-instance–learning deep learning (DL) model was trained and initially evaluated through 5-fold cross validation with case-level stratification, followed by validation using an independent holdout data set. Quantitative performance evaluation was based on accuracy and the area under the receiver operating characteristic curve (AUC). Results.— The developed model data set yielded generalizable performance, with a 5-fold average testing accuracy of 84% (AUC = 0.78), and a closely aligning accuracy of 83% (AUC = 0.92) on the independent holdout data set. Conclusions.— The proposed artificial intelligence approach contributes toward a comprehensive solution for addressing commonly encountered renal oncocytic neoplasms, encompassing well-established entities like RO along with the challenging “gray zone” LOT, thereby proving applicable in clinical practice.
A Report of Two Uncommon Cases of Mycobacterium chelonae with Localized and Disseminated Skin and Soft Tissue Infection
Background: Mycobacterium chelonae is a ubiquitous, rapidly growing, nontuberculous mycobacteria that primarily affects immunocompromised patients. The most common presentation is an atypical, chronic skin and soft tissue infection. Due to its high resistance rate, early diagnosis based on clinical suspicion, risk factor assessment, and exposure history is crucial for initiating appropriate multi-drug treatment. Methods: We report two cases of M. chelonae skin and soft tissue infections, one presenting with localized disease and the other with disseminated involvement. One case had a specific exposure to fish-related activities, a risk factor more commonly associated with Mycobacterium marinum infections rather than M. chelonae. Results: One of the cases involved osteomyelitis and tenosynovitis which are rare presentations of M. chelonae infection. While the limbs are the most commonly affected sites in disseminated M. chelonae infections, involvement of the lower extremities, as seen in one of our cases, is rarely reported. Treatment posed challenges due to antibiotic resistance and patient tolerance. However, in both cases where follow up was possible, prolonged multi-drug therapy led to complete resolution of the lesions. Conclusions: These cases highlight the importance of considering M. chelonae in chronic skin and soft tissue infections, especially in patient with relevant exposures or immunosupression. Uncommon presentations require a high index of suspicion. Given the challenges of treatment resistance and patient tolerance, prolonged multi-drug therapy remains essential for successful outcomes.
A comparison of carbon ions versus protons for integrated mode ion imaging
Abstract Background Incorporating image guidance into ion beam therapy is critical for minimizing beam range uncertainties and realizing the modality's potential. One promising avenue for image guidance is to capture transmission ion radiographs (iRads) before and/or during treatment. iRad image quality is typically maximized using a single‐event imaging system, which involves tracking individual ions, albeit the approach is generally not suited to clinical beam settings. An alternative faster and clinically compatible method is integrated mode imaging, where individual pencil beam data is acquired, rather than single ion data. To evaluate the usefulness of transmission ion imaging for image guidance, it is crucial to evaluate the image quality of integrated mode iRad systems. Purpose We report extensive image quality metrics of integrated mode carbon ion radiographs (cRads) and compare them with proton radiographs (pRads). Methods iRads were obtained at the Marburg Ion Beam Therapy Center using a plastic volumetric scintillator equipped with CCD cameras. The detector captures orthogonal views of the 3D energy deposition in the scintillator from individual pencil beams. Four phantoms were scanned using a field of view and a beam spacing of 1 mm. First, 9 tissue‐substitute inserts were used to evaluate water equivalent thickness (WET) accuracy. Radiographs of those inserts were reconstructed for beam spacings ranging from 1 to 7 mm to evaluate the impact of spacing on quantitative accuracy. For spatial resolution, custom 3D printed line pair (lp) modules ranging from 0.5 to 10 lp/cm were scanned. To evaluate low contrast detectability, a custom 3D printed low contrast module consisting of 20 holes with depths ranging from 1 to 8 mm and diameters from 1 to 10 mm was scanned. iRads of an anthropomorphic head phantom were also obtained. Results Spatial resolution and low contrast detection are systematically improved for cRads compared to pRads. Image resolution was 3.7 lp/cm for cRads and 1.7 lp/cm for pRads in the center of the field of view. Spatial resolution was found to vary with the object's location in the field of view. While pRads could mostly resolve low contrast holes of 10 mm in diameter, cRads could resolve holes of up in 4 mm diameter. WET accuracy is similar for both ion species, with a root mean squared error of approximately 1 mm. WET accuracy was stable (maximum of 0.1 mm increase) across beam spacings, although important under‐sampling artifacts were observed for iRads reconstructed using large beam spacings, especially for cRads. iRads of the anthropomorphic head phantom showed improved apparent contrast using cRads, especially to identify bony structures. Conclusions This work is the first investigation of image quality metrics such as spatial resolution and low contrast detectability for integrated mode cRads, with a full comparison with pRads. Enhanced image quality is obtained with cRads compared to pRads, although pRads still maintain high WET accuracy and deliver image quality within acceptable bounds.
Photon Counting Detector CTA for Prostate Artery Embolization Pre-Procedure Planning and Intra-Procedural Guidance: A Case Series
Abstract Background: Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance for embolization. Photon counting detector (PCD) CT is a novel technology enabling ultra-high spatial resolution (UHR) whole-body imaging, with reconstructed slices as thin as 200 um. For PAE, we obtain a single UHR PCD CT acquisition, which provides both detailed pre-procedure pelvic arterial anatomy information and a registration reference for intra-procedural embolization guidance. Case Presentation: In five patients who underwent technically successful PAE via a left transradial approach, the pre-procedure diagnostic UHR PCD prostate CTA delineated bilateral prostatic artery origins and course in all cases, as confirmed with conventional angiograms. Further, registration of the UHR PCD CT for embolization guidance was successful in all cases, augmenting vessel selection. No complication occurred. Conclusion: UHR PCD CT is a novel acquisition option that is well suited to PAE due to its ability to delineate small vessels. Further, our experience has shown that a single pre-procedure scan can also be utilized for intra-procedural embolization guidance, obviating the need for a traditional cone beam CT angiogram. Further research is needed to assess reductions in radiation dose, contrast use, and intra-procedural time with these techniques.
1376: POCUS UTILIZATION BY ADVANCED PRACTICE PROVIDERS COMPARED TO INTENSIVISTS: (CUSP) SURVEY DATA
Abstract Background We previously identified circulating and MRI biomarkers associated with the surgical management of Crohn’s disease (CD). Here we tested associations between these biomarkers and ileal resection inflammation and collagen content. Methods Fifty CD patients undergoing ileal resection were prospectively enrolled at 4 centers. Circulating CD64, extracellular matrix protein 1 (ECM1), GM-CSF autoantibodies (GM-CSF Ab), and fecal calprotectin were measured by ELISA. Ileal 3-dimensional magnetization transfer ratio (3D MTR), modified Look-Locker inversion recovery (MOLLI) T1 relaxation, diffusion-weighted intravoxel incoherent motion (IVIM), and the simplified magnetic resonance index of activity (sMaRIA) were measured by MRI. Ileal resection specimen acute inflammation was graded, and collagen content was measured quantitatively using second harmonic imaging microscopy. Associations between biomarkers and ileal collagen content were tested. Results Median (interquartile range [IQR]) age was 19.5 (16-33) years. We observed an inverse relationship between ileal acute inflammation and collagen content (r = −0.39 [95% confidence interval {CI}: −0.61, −0.10], P = .008). Most patients (33 [66%]) received biologics, with no variation in collagen content with treatment exposures. In the univariate analysis, CD64, GM-CSF Ab, fecal calprotectin, and sMaRIA were positively associated with acute inflammation and negatively associated with collagen content (P < .1). The multivariable model for ileal collagen content (R2 = 0.31 [95% CI: 0.11, 0.52]) included log CD64 (β = −.27; P = .19), log ECM1 (β = .47; P = .06), log GM-CSF Ab (β = −.15; P = .01), IVIM f (β = .29, P = .10), and IVIM D* (β = 1.69, P = .13). Conclusions Clinically available and exploratory circulating and MRI biomarkers are associated with the degree of inflammation versus fibrosis in CD ileal resections. With further validation, these biomarkers may be used to guide medical and surgical decision-making for refractory CD.
Antifouling Immunomodulatory Copolymer Architectures That Inhibit the Fibrosis of Implants
Abstract Immune reactions to medical implants often lead to encapsulation by fibrotic tissue and impaired device function. This process is thought to initiate by protein adsorption, which enables immune cells to attach and mount an inflammatory response. Previously, several antifibrotic materials have been either designed to reduce protein adsorption or discovered via high‐throughput screens (HTS) to favorably regulate inflammation. The present work introduces antifouling immunomodulatory (AIM) copolymer coatings, which combine both strategies to effectively enhance implant protection. AIM copolymers synergistically integrate zwitterionic moieties to resist protein fouling, HTS‐derived antifibrotics for immunomodulation, and silane monomers for grafting to diverse substrates including elastomers, ceramics, and metals. Interestingly, simply combining these monomers into conventional random or block copolymer architectures yielded no significant advantage over homopolymers. By contrast, an unusual polymer chain architecture — a zwitterionic block flanked by a mixed zwitterionic immunomodulatory segment — showed superior fibrosis resistance in both peritoneal and subcutaneous sites over one month in immunocompetent mice. This architecture also improved the performance of two different HTS‐derived antifibrotic monomers, suggesting that tailoring AIM architectures may broadly complement immunomodulatory chemistries and provide a versatile approach to improving implant longevity.