Citations

Mayo Clinic

Clear

560 citation(s) found for "Yu, Mei".

Response letter‐to‐the editor entitled “Transvenous lead extraction, only once or repeatable?”
Cha, Yong‐Mei , Birgersdotter‐Green, Ulrika

Pacing and Clinical Electrophysiology | December 5, 2018 | Volume: 42 | Issue: 2 | Pages: 297-297

10.1111/pace.13561 | PMID 30516285 Get It

A Trans-Atlantic Perspective on Stagnation in Clinical Translation of Antimicrobial Strategies for the Control of Biomaterial-Implant-Associated Infection
Busscher, Henk J. , Mei, Henny C. van der , Fagette, Paul, Zimmerli, Werner, Schmidmaier, Gerhard , Raschke, Michael J. , Gehrke, Thorsten , Bayston, Roger , Winterton, Lynn, Darouiche, Rabih O., Grainger, David W. , Alt, Volker , Moriarty, T Fintan , Parvizi, Javad , Gehrke, Thorsten A. , Baddour, Larry M.

ACS Biomaterials Science & Engineering | December 2, 2018 | Volume: 5 | Issue: 2 | Pages: 402-406

10.1021/acsbiomaterials.8b01071 | PMID 30775431 Get It

Super-response to cardiac resynchronization therapy reduces appropriate implantable cardioverter-defibrillator therapy: comment—Authors’ reply
Killu, Ammar M. , Cha, Yong‐Mei

EP Europace | November 2, 2018 | Volume: 21 | Issue: 1 | Pages: 179-179

10.1093/europace/euy244 | PMID 30428067 Get It

Diagnostic and therapeutic value of implantable loop recorder: A tertiary care center experience
Padmanabhan, Deepak , Kancharla, Krishna , El‐Harasis, Majd , Isath, Ameesh , Makkar, Nayani , Noseworthy, Peter A. , Friedman, Paul A. , Cha, Yong‐Mei , El-Harasis, Majd A, Kapa, Suraj , Noseworthy, Peter A , Kapa, Suraj

Pacing and Clinical Electrophysiology | October 25, 2018 | Volume: 42 | Issue: 1 | Pages: 38-45

10.1111/pace.13533 | PMID 30357866 Get It

AbstractBackgroundImplantable loop recorders (ILRs) are effective in achieving symptom‐rhythm correlation. However, diagnostic yield in routine clinical practice is not well established.MethodsPatients undergoing ILR implantation between April 2010 and May 2015 were included. All devices were enrolled in remote monitoring with automatic arrhythmia detection and P sense algorithms switched “ON.” Symptom‐rhythm correlation was assessed and changes in management were recorded.ResultsA total of 312 patients (57% male, age 53 ± 22 years; median CHADS2VaSc score = 1) were included in this study. ILRs were implanted for evaluation of syncope in 206 (66.0%), presyncope in 23 (7.4%), unexplained palpitations in 51 (16.3%), and cryptogenic stroke in 27 (8.7%) patients. ILR monitoring yielded a diagnosis that changed management strategy in 146 (46.8%) patients over a median of 12 (1‐42) months. Out of 163 (52.2%) patients with symptoms during the monitoring period, 100 (61.3%) had an arrhythmia. ILR was useful in ruling out an arrhythmic cause for symptoms in 63 (38.7%) patients. ILR results led to pacemaker implantation in 23 patients (7.4% overall and 11.2% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, 11 of whom were initiated on oral anticoagulants. ILR results led to pacemaker implantation in 31 patients (9.9% overall and 19.0% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, nine of whom were initiated on oral anticoagulants. Overall, ILR led to a change in management in 47% patients with a number needed to implant of 2.1 to change management.ConclusionILR monitoring is effective in achieving symptom‐rhythm correlation and results in changes in management in nearly half of implanted patients. Additional studies are needed to evaluate cost efficacy of ILR and the optimal monitoring duration.
Clinical Features Associated with Survival Outcome in African-American Patients with Hepatocellular Carcinoma
Estevez, Jacqueline, Yang, Ju Dong , Leong, Jennifer , Nguyen, Pauline, Giama, Nasra H., Zhang, Ning , Ali, Hamdi A. , Cheung, Ramsey , Roberts, Lewis R. , Schwartz, Myron , Nguyen, Mindie H. , Roberts, Lewis, Roberts, Lewis R , Yang, Ju Dong , Lee, Mei–Hsuan

American Journal of Gastroenterology | October 17, 2018 | Volume: 114 | Issue: 1 | Pages: 80-88

10.1038/s41395-018-0261-y | PMID 30333542 Get It

BACKGROUND: African-Americans (AA) have a higher incidence of hepatocellular carcinoma (HCC) and lower survival. We characterized survival rates and clinical features associated with survival in AA vs. Caucasians with HCC over the past two decades. METHODS: HCC patients from three US medical centers were matched by year of diagnosis (1991–2016): AA ( n = 578)/Caucasian ( n = 578) and placed in one of two groups—HCC diagnosed prior to 2010 or 2010 and after. Data were obtained from chart review and the National Death Index. Multivariate and survival analysis controlling for key predictors were conducted. RESULTS: Prior to 2010, there was no difference in survival between Caucasians and AA ( p = 0.61). After 2010, AA patients had poorer survival compared to Caucasians (35% vs. 44%, respectively, p = 0.044). Over time, survival improved for Caucasians (32% before 2010 vs. 44% after 2010, p = 0.003), but not AA (36% vs. 35%, p = 0.50). AA on presentation (in the after 2010 cohort) were more likely to have BCLC (Barcelona Clinic Liver Cancer) stage C (24% vs. 15%, p = 0.010) and less likely to receive treatment (85% vs. 93%, p = 0.002) compared to matched Caucasians. BCLC beyond stage A (aHR: 1.75, 95% CI: 1.26–2.43, p = 0.001) and child’s class C (aHR 2.05, 95% CI: 1.23–3.41, p = 0.006) were the strongest predictors of mortality, while race was not. CONCLUSIONS: African-Americans presented with more advanced HCC and had poorer survival compared to Caucasians after 2010. Tumor stage was an independent predictor of mortality, but ethnicity was not. Further efforts are needed to improve early HCC diagnosis for AA.
HCN1mutation spectrum: from neonatal epileptic encephalopathy to benign generalized epilepsy and beyond
Marini, Carla , Porro, Alessandro , Rastetter, Agnès, Dalle, Carine, Rivolta, Ilaria , Bauer, Daniel , Oegema, Renske , Nava, Caroline , Parrini, Elena , Mei, Davide , Mercer, Catherine , Dhamija, Radhika , Chambers, Chelsea , Coubes, Christine, Kuentz, Paul , Julia, Sophie , Pasquier, Laurent , Dubourg, Christèle , Carré, Wilfrid , Melani, Federico , Giardino, Maria , Innes, A. Micheil , Alembik, Yves, Scheidecker, Sophie , Figueiroa, Sónia, Garrido, Cristina , Fusco, Carlo , Spagnoli, Carlotta , Binda, Anna , Granata, Tiziana , Ragona, Francesca , Freri, Elena , Franceschetti, Silvana , Canafoglia, Laura , Castellotti, Barbara , Gellera, Cinzia , Milanesi, Raffaella , Mancardi, Maria Margherita , Clark, Damien R, Helbig, Katherine L. , Ichikawa, Shoji , Sadler, Laurie S. , Neupauerová, Jana, Laššuthová, Petra , Štěrbová, Katalin , Laridon, Annick, Brilstra, Eva H. , Koeleman, Bobby P.C. , Striano, Pasquale, Soblet, Julie , Deconinck, Nicolas , Leguern, Éric , Guerrini, Renzo , Santoro, Bina , Hamacher, Kay , Moroni, Anna , DiFrancesco, Jacopo C. , Depienne, Christel , Guerrini, Renzo , Mei, Davide , Pasquier, Laurent , Thévenon, Julien , Rosati, Anna Maria , Pisano, Tiziana , Santos, Manuela M. , Frattini, Daniele , Clark, Damien R., Kok, Fernando , Lemke, Johannes R. , Zara, Federico , Smits, Guillaume , Barbuti, Andrea , DiFrancesco, Dario , Thiel, Gerhard , Depienne, Christel , Dhamija, Radhika

Brain | September 26, 2018 | Volume: 141 | Issue: 11 | Pages: 3160-3178

10.1093/brain/awy263 | PMID 30351409 Get It

Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
Madhavan, Malini , Waks, Jonathan W. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mehta, Ramila A. , Hodge, David O. , Higgins, Angela , Webster, Tracy L., Witt, Chance M. , Cha, Yong‐Mei , Higgins, Angela Y. , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 17, 2018 | Volume: 9 | Issue: 3 | Pages: No page available

10.1161/circep.115.003283 | PMID 26921377 Get It

Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Lushinsky, Emilie C., Mulholland, Megan B., Cha, Yong‐Mei , Madhavan, Malini , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 14, 2018 | Volume: 11 | Issue: 8 | Pages: No page available

10.1161/circep.117.006155 | PMID 30354311 Get It

Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
Burden of cytopenias among myelofibrosis patients.
Feliciano, Joseph, Yang, Yoojung, Lü, Mei , Hooper, Ellen , Mesa, Ruben A.

Journal of Clinical Oncology | September 6, 2018 | Volume: 34 | Issue: 15_suppl | Pages: e18260-e18260

10.1200/jco.2016.34.15_suppl.e18260 Get It