Citations

Mayo Clinic

Clear

27 citation(s) found for "Luo, Zong Ping".

CHONDROCYTE RESPONSE TO TENSILE AND COMPRESSIVE CYCLIC LOADING MODALITIES
Kamineni, Srinath , Wani, Zubair , Luo, Zong-Ping , An, Kai‐Nan , Yoshida, Ruriko

Journal of Musculoskeletal Research | March 23, 2012 | Volume: 15 | Issue: 01 | Pages: 1250006

10.1142/s0218957712500066 Get It

There is very little data addressing cartilage response to tensile forces, and no literature attempts to correlate compressive with tensile modalities. Our hypothesis was that the cyclic compression and tension modulate chondrocyte matrix proteoglycan synthetic response differently. Porcine chondrocytes cultured to confluence on a flexible membrane were subjected to cyclic compression (Group A: 13 KPa at 1 Hz) or tension (Group C: 10% strain at 1 Hz) for 16 or 32 h; while controls not subjected to any force were kept (Group B). The chondrocytes were then stained with alcian blue and stained areas quantified with confocal microscopy and image processing software. Two-factor ANOVA with post-hoc tests (Scheffe and Bonferroni) statistical analysis were used. Proteoglycan staining covered 46% (range 28%–61%) and 39% (range 26%–49%) of the surface area following 32 and 16 h of compression respectively, 23% (range 15%–49%) for control, and 19% (range 10%–29%) and 16% (range 9%–25%) following 16 and 32 h tension respectively. Proteoglycan content following all compressions was significantly greater than with cyclic tension or control (p < 0.0001). Our data demonstrate that chondrocytes cultured in vitro respond to compression distinctly different from tension and that it is highly sensitive to mechanical loading, with rapid adaptation to its mechanical environment. These results imply that cartilage grown in culture, with the intention of transplantation, may structurally benefit from an environment of cyclic loading at higher frequencies.
Ankle Stability in Simulated Lateral Ankle Ligament Injuries
Fujii, Tadashi , Kitaoka, Harold B. , Watanabe, Kota , Luo, Zong-Ping , An, Kai‐Nan

Foot & Ankle International | June 18, 2010 | Volume: 31 | Issue: 6 | Pages: 531-537

10.3113/fai.2010.0531 | PMID 20557820 Get It

Background: We performed a laboratory-based study of the ankle-hindfoot complex in normal cadaveric ankles with simulated lateral ankle ligament injuries, utilizing an ankle stability testing device. The ankle stability testing device distinguished between intact, injury to anterior talofibular ligament (ATFL) and combined injury to ATFL and calcaneofibular ligament (CFL). Materials and Methods: Ankles were tested in an ankle stability testing device, with a specified inversion torque applied through the range of sagittal plane motion, then internal rotation torque applied through the entire range of sagittal plane motion. Three-dimensional motion of the calcaneus and talus in relation to the tibia were determined with a magnetic tracking system. The specimens were tested in the intact condition, then after sectioning the ATFL, then the CFL. Results: Upon sectioning the ATFL, there was a significant increase in the internal rotation motion at the tibiotalar joint. Subsequent sectioning of the CFL did not significantly increase ankle-hindfoot internal rotation, but it did significantly increase the motion in inversion testing. This increase occurred primarily at the tibiotalar level. Conclusion: The isolated ATFL injury was clearly distinguished from the intact condition by increased talar-tibial internal rotation, but not inversion. The more severe combined ATFL/CFL injury was distinguished from the ATFL injury condition with inversion torque. Clinical Relevance: Inversion torque may disclose combined ATFL/CFL injury, and internal rotation torque may be the key to distinguish isolated ATFL and combined ATFL/CFL injuries.
Importance of Soft Tissue Integrity on Biomechanical Studies of the Patella After TKA
Luo, Zong-Ping , Hsu, Horng-Chaung, Rand, J.A. , An, Kai‐Nan

Journal of Biomechanical Engineering | February 21, 2008 | Volume: 118 | Issue: 1 | Pages: 130-132

10.1115/1.2795938 | PMID 8833084 Get It

This study evaluated the effects of soft tissue integrity on patellar tracking and patellofemoral joint force after total knee arthroplasty. The results indicate that partial dissection of the soft tissue integrity in the in vitro biomechanical studies of the patellofemoral joint can alter patellar tracking and joint force significantly, leading to improper conclusions.
Three-Dimensional Analysis of Normal Ankle and Foot Mobility
Kitaoka, Harold B. , Luo, Zong Ping, An, Kai‐Nan , Luo, Zong Ping

The American Journal of Sports Medicine | June 21, 2007 | Volume: 25 | Issue: 2 | Pages: 238-242

10.1177/036354659702500218 | PMID 9079181 Get It

We defined foot and ankle motion with respect to the neutral position. Thirteen normal fresh-frozen speci mens of the human foot were used. The foot was placed in the extreme positions of pronation, supina tion, dorsiflexion, and plantar flexion, and positions of multiple bones were monitored simultaneously with a magnetic tracking device to determine rotation of the talocrural, subtalar, metatarsal-navicular, and talo navicular joints under the various conditions. In prona tion, the most rotation occurred at the metatarsal-na vicular level, followed by the navicular-talar, talar-tibial, and calcaneal-talar levels. In supination, most rotation occurred at the navicular-talar level, followed by the calcaneal-talar, talar-tibial, and metatarsal-navicular levels. In dorsiflexion, most rotation occurred at the talar-tibial level, followed by the navicular-talar, calca neal-talar, and metatarsal-navicular levels. In plantar flexion, most rotation occurred at the talar-tibial level, but there was considerable motion at the navicular- talar, metatarsal-navicular, and calcaneal-talar levels. Understanding the specific joint motions that occur with various positions of the foot and ankle is important because measurements of joint mobility may assist in establishing diagnoses, monitoring clinical conditions, determining indications for operative treatment, as sessing results of treatment, and following the progress of rehabilitation.
IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAIT
Kim, Kyu-Jung, Kitaoka, Harold B. , Luo, Zong‐Ping , Ozeki, Satoru , Berglund, Lawrence J., An, Kai‐Nan, Kaufman, Kenton R.

Journal of Musculoskeletal Research | April 22, 2003 | Volume: 05 | Issue: 02 | Pages: 113-121

10.1142/s0218957701000490 Get It

The purpose of this study is to develop an electromechanical system for dynamic simulation of the stance phase of a human gait using cadaveric foot specimens. The system can be used for quantification of foot and ankle pathomechanics and design of foot and ankle reconstructive surgeries. Servo-pneumatic systems were used for application of the tibial weight loading and muscle loadings. A four-bar mechanism was constructed to provide the progressive motion of a tibia during the simulation while the external loadings were simultaneously applied. Muscle loadings were estimated based on the physiological cross-sectional area and normal electromyography (EMG) data with the assumption of the linear EMG–force relationship. Ad hoc tuning of the unknown muscle gains was conducted until a reasonable match with the normal vertical ground reaction force profile, center of pressure advancement, and characteristic foot motion events (heel strike, foot flat, heel rise and toe-off) could be made. Three cadaver feet and an artificial foot were tested with five repeated trials. The simulator reproduced the stance phase of a human gait in the sagittal plane with reasonable accuracy and consistency without compromising either kinematics or kinetics of the foot and ankle complex.
Determination of the Compressive Material Properties of the Supraspinatus Tendon
Zobitz, Mark E., Luo, Zong‐Ping , An, Kai‐Nan

Journal of Biomechanical Engineering | July 27, 2002 | Volume: 123 | Issue: 1 | Pages: 47-51

10.1115/1.1339816 | PMID 11277301 Get It

A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1g (SD: 0.9g). Therefore, the compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.
An optical spin micromotor
Luo, Zong-Ping , Sun, Yu-Long, An, Kai‐Nan

Applied Physics Letters | July 26, 2002 | Volume: 76 | Issue: 13 | Pages: 1779-1781

10.1063/1.126165 Get It

An optical spin micromotor operated by optical tweezers, described in the present study, converts radiant energy directly to mechanical energy. This conversion is of great practical and fundamental interest. The optical spin micromotor consists of a two-bead linkage. The large bead (2.0 μm in diameter) is trapped by the optical tweezers and rotates around the laser beam axis. The small bead (0.94 μm in diameter) is partially coated with gold/palladium for generating the spin torque through the change of momentum from gradient radiation pressure of the same laser applied on the coated small bead. With a laser power of 29 mW at the sample plane, the spin speed averaged 158.8±155.5 rpm (mean±standard deviation) and the torque was estimated as 101.9±99.8 pN nm. This optical spin micromotor will be useful in (1) providing a fundamental step toward developing optical-operated mechanical devices, (2) twisting macromolecules, and (3) generating vortex and shear force in medium at nanoscale.