Citations

Mayo Clinic

Clear

37 citation(s) found for "Lundy, J K".

A Retrospective Estimate of Ear Disease Detection Using the “Red Flags” in a Clinical Sample
Klyn, Niall A. M. , Alfakir, Razan , Nielsen, Donald W., Carlson, Deborah , Lundy, Larry, Dhar, Sumitrajit , Zapala, David A., Kleindienst Robler, Samantha, Alfakir, Razan , Robler, Samantha Kleindienst , Griffith, James William

Ear & Hearing | March 2, 2018 | Volume: 39 | Issue: 5 | Pages: 1035-1038

10.1097/aud.0000000000000561 | PMID 29498954 Get It

Objectives: The purpose of this study was to evaluate the specificity and sensitivity of two red flag protocols in detecting ear diseases associated with changes in hearing. Design: The presence of red-flag symptoms was determined in a chart review of 307 adult patients from the Mayo Clinic Florida Departments of Otorhinolaryngology and Audiology. Participants formed a convenience sample recruited for a separate study. Neurotologist diagnosis was the criterion for comparisons. Results: Of the 251 patient files retained for analysis, 191 had one or more targeted diseases and 60 had age- or noise-related hearing loss. Food and Drug Administration red flags sensitivity was 91% (confidence interval [CI], 86 to 95%) and specificity was 72% (CI, 59 to 83%). American Academy of Otolaryngology-Head and Neck Surgery red flags sensitivity was 98% (CI, 95 to 99%) and specificity was 20% (CI, 11 to 32%). Conclusions: Stakeholders must determine which diseases are meaningful contraindications for hearing aid use and whether these red-flag protocols have acceptable levels of sensitivity and specificity. As direct-to-consumer models of hearing devices increase, a disease detection method that does not require provider intercession would be useful.
Development and Initial Validation of a Consumer Questionnaire to Predict the Presence of Ear Disease
Kleindienst, Samantha J., Zapala, David A., Nielsen, Donald W., Rishiq, Dania , Lundy, Larry, Dhar, Sumitrajit , Griffith, James William

JAMA Otolaryngology–Head & Neck Surgery | August 3, 2017 | Volume: 143 | Issue: 10 | Pages: 983

10.1001/jamaoto.2017.1175 | PMID 28772310 Get It

Choice of Anesthetic Methods for Urologic Operations in Various Age Groups
Lundy, John S.

Journal of Urology | June 30, 2017 | Volume: 67 | Issue: 5 | Pages: 745-749

10.1016/s0022-5347(17)68414-3 | PMID 14939391 Get It

Regional Anesthesia for Operations in the Urinary Bladder
Lundy, John S.

Journal of Urology | June 29, 2017 | Volume: 17 | Issue: 6 | Pages: 525-556

10.1016/s0022-5347(17)73374-5 Get It

Identifying and Prioritizing Diseases Important for Detection in Adult Hearing Health Care
Kleindienst, Samantha J., Dhar, Sumitrajit , Nielsen, Donald W., Lundy, Larry, Driscoll, Colin L. W., Neff, Brian, Beatty, Charles W., Barrs, David M., Zapala, David A., Lundy, Larry B, Beatty, Charles, Barrs, David, Griffith, James William , Neff, Brian A.

American Journal of Audiology | September 27, 2016 | Volume: 25 | Issue: 3 | Pages: 224-231

10.1044/2016_aja-15-0079 | PMID 27679840 Get It

Purpose The purpose of this research note is to identify and prioritize diseases important for detection in adult hearing health care delivery systems. Method Through literature review and expert consultation, the authors identified 195 diseases likely to occur in adults complaining of hearing loss. Five neurotologists rated the importance of disease on 3 dimensions related to the necessity of detection prior to adult hearing aid fitting. Results Ratings of adverse health consequences, diagnostic difficulty, and presence of nonotologic symptoms associated with these diseases resulted in the identification of 104 diseases potentially important for detection prior to adult hearing aid fitting. Conclusions Current and evolving health care delivery systems, including direct-to-consumer sales, involve inconsistent means of disease detection vigilance prior to device fitting. The first steps in determining the safety of these different delivery methods are to identify and prioritize which diseases present the greatest risk for poor health outcomes and, thus, should be detected in hearing health care delivery systems. Here the authors have developed a novel multidimensional rating system to rank disease importance. The rankings can be used to evaluate the effectiveness of alternative detection methods and to inform public health policy. The authors are currently using this information to validate a consumer questionnaire designed to accurately identify when pre- fitting medical evaluations should be required for hearing aid patients.
Novel radiology method for investigating middle ear myoclonus
Siegel, Jason , Lundy, Larry, Dove, Conrad, Mansour, Philip, Wszołek, Zbigniew K.

Clinical Anatomy | April 18, 2016 | Volume: 29 | Issue: 6 | Pages: 811-812

10.1002/ca.22728 | PMID 27087543 Get It

The Effect of Repetition Rate on Air-Conducted Ocular Vestibular Evoked Myogenic Potentials (oVEMPs)
Bogle, Jamie M. , Zapala, David A., Burkhardt, Brittany, Walker, Kurt, Lundy, Larry, Shelfer, Janet, Pratt, Terri L., Garry, Millicent, Walker, David

American Journal of Audiology | May 21, 2015 | Volume: 24 | Issue: 3 | Pages: 411-418

10.1044/2015_aja-15-0011 | PMID 25997090 Get It

Purpose Ocular vestibular evoked myogenic potentials (oVEMPs) are used to describe utricular/superior vestibular nerve function; however, optimal recording parameters have not been fully established. This study investigated the effect of repetition rate on air-conducted oVEMPs. Method Ten healthy adults were evaluated using 500-Hz tone bursts (4-ms duration, Blackman gating, 122 dB pSPL). Four repetition rates were used (1.6, 4.8, 8.3, and 26.6 Hz) and resulting oVEMP response presence, amplitude, amplitude asymmetry, and n1/p1 latency were assessed. Results Response presence was significantly reduced for 26.6 Hz using monaural stimulation and for 8.3 Hz and 26.6 Hz for binaural stimulation. For monaural stimulation using 1.6, 4.8, and 8.3 Hz, no significant differences were noted for amplitude or latency. Responses obtained using binaural stimulation demonstrated a significant effect of rate on amplitude, with 8.3 Hz producing significantly reduced amplitude. Binaural amplitudes were significantly larger than monaural contralateral responses but with reduced response presence. No significant differences were noted for latency or amplitude asymmetry. Conclusion Using repetition rates of approximately 5 Hz or less may produce more consistent oVEMP response presence with minimal effects on amplitude for monaural or binaural recordings.
The Significance of Pulmonary Artery Size in Pulmonary Hypertension
Whitlock, Joseph P., Lundy, Taylor , Carabenciov, Ivan D. , Lee, Augustine S. , Ussavarungsi, Kamonpun , Burger, Charles D.

Diseases | August 4, 2014 | Volume: 2 | Issue: 3 | Pages: 243-259

10.3390/diseases2030243 Get It

Pulmonary hypertension (PH) has been found to have significant morbidity and mortality. The treatment of PH has advanced considerably with increasingly more effective and safer options. With an increasing effort to diagnose patients early, non-invasive techniques are often used to screen those patients likely to have PH. Computerized tomography (CT) chest scans are increasingly utilized in the evaluation of patients with exertional dyspnea, including those with suspected PH. The main role of the CT scan is to evaluate for any associated underlying diseases. There have been attempts to address the utility of CT to predict the presence of PH. This article reviews previously published investigations to summarize the relationship between pulmonary artery dimensions and PH to determine both the strength of the correlation and its discriminatory ability for use in clinical practice.
An Evaluation of Replacement Fluids in Laboratory Animals following Control Hemorrhage
Morrison, AD, Lundy, John S., Essex, Hiram E.

Circulation | June 11, 2012 | Volume: 5 | Issue: 2 | Pages: 208-214

10.1161/01.cir.5.2.208 | PMID 14896465 Get It

Solutions of Dextran Ph, Plasmoid, Periston and isotonic saline were compared with serum albumin and whole blood to determine the efficacy of the former as blood substitutes. Rats, guinea pigs and dogs were used as experimental animals. Dextran Ph, Plasmoid and Periston were found to be less satisfactory than whole blood, since 50 to 80 per cent of the rats and guinea pigs survived following their use compared with 100 per cent survival when whole blood was given. There was, however, 100 per cent mortality of the animals when a blood substitute was not given.
CURARE AND CURARE LIKE COMPOUNDS: A REVIEW
ROBBINS, BENJAMIN H. , Lundy, John S.

Anesthesiology | November 27, 2008 | Volume: 8 | Issue: 4 | Pages: 348-358

10.1097/00000542-194707000-00002 | PMID 20255055 Get It