Citations

Mayo Clinic

Clear

367 citation(s) found for "Xu, Site".

Erratum to: Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
He, Lidong, Barnidge, David R. , Murray, David , Hendrickson, Christopher L. , Marshall, Alan G. , Murray, David L., Anderson, Lissa C.

Journal of the American Society for Mass Spectrometry | March 23, 2017 | Volume: 28 | Issue: 5 | Pages: 839-839

10.1007/s13361-017-1652-9 | PMID 28337658 Get It

Assessment of renal response with urinary exosomes in patients with AL amyloidosis: A proof of concept
Ramı́rez-Alvarado, Marina , Barnidge, David R. , Murray, David , Marin‐Argany, Marta , Dick, Christopher J., Cooper, Shawna A. , Nasr, Samih H. , Ward, Christopher J. , Dasari, Surendra , Jiménez‐Zepeda, Víctor H. , Murray, David L., Marin-Argany, Marta, Leung, Nelson , Dispenzieri, Angela , Leung, Nelson , Ramirez-Alvarado, Marina , Cooper, Shawna A

American Journal of Hematology | March 10, 2017 | Volume: 92 | Issue: 6 | Pages: 536-541

10.1002/ajh.24717 | PMID 28295502 Get It

AbstractImmunoglobulin light chain (AL) amyloidosis is a fatal complication of B‐cell proliferation secondary to deposition of amyloid fibrils in various organs. Urinary exosomes (UEX) are the smallest of the microvesicles excreted in the urine. Previously, we found UEX of patients with AL amyloidosis contained immunoglobulin light chain (LC) oligomers that patients with multiple myeloma did not have. To further explore the role of the LC oligomers, UEX was isolated from an AL amyloidosis patient with progressive renal disease despite achieving a complete response. LC oligomers were identified. Mass spectrometry (MS) of the UEX and serum identified two monoclonal lambda LCs. Proteomics of the trypsin digested amyloid fragments in the kidney by laser microdissection and MS analysis identified a λ6 LC. The cDNA from plasma cell clone was from the IGLV‐ 6‐57 family and it matched the amino acid sequences of the amyloid peptides. The predicted mass of the peptide product of the cDNA matched the mass of one of the two LCs identified in the UEX and serum. UEX combined with MS were able to identify 2 monoclonal lambda LCs that current clinical methods could not. It also identified the amyloidogenic LC which holds potential for response assessment in the future.
Mass Spectrometry Approaches for Identification and Quantitation of Therapeutic Monoclonal Antibodies in the Clinical Laboratory
Ladwig, Paula M. , Barnidge, David R. , Willrich, Maria A V, Willrich, Maria Alice V.

Clinical and Vaccine Immunology | March 9, 2017 | Volume: 24 | Issue: 5 | Pages: No page available

10.1128/cvi.00545-16 | PMID 28274937 Get It

ABSTRACTTherapeutic monoclonal antibodies (MAbs) are an important class of drugs used to treat diseases ranging from autoimmune disorders to B cell lymphomas to other rare conditions thought to be untreatable in the past. Many advances have been made in the characterization of immunoglobulins as a result of pharmaceutical companies investing in technologies that allow them to better understand MAbs during the development phase. Mass spectrometry is one of the new advancements utilized extensively by pharma to analyze MAbs and is now beginning to be applied in the clinical laboratory setting. The rise in the use of therapeutic MAbs has opened up new challenges for the development of assays for monitoring this class of drugs. MAbs are larger and more complex than typical small-molecule therapeutic drugs routinely analyzed by mass spectrometry. In addition, they must be quantified in samples that contain endogenous immunoglobulins with nearly identical structures. In contrast to an enzyme-linked immunosorbent assay (ELISA) for quantifying MAbs, mass spectrometry-based assays do not rely on MAb-specific reagents such as recombinant antigens and/or anti-idiotypic antibodies, and time for development is usually shorter. Furthermore, using molecular mass as a measurement tool provides increased specificity since it is a first-order principle unique to each MAb. This enables rapid quantification of MAbs and multiplexing. This review describes how mass spectrometry can become an important tool for clinical chemists and especially immunologists, who are starting to develop assays for MAbs in the clinical laboratory and are considering mass spectrometry as a versatile platform for the task.
Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
He, Lidong, Barnidge, David R. , Murray, David , Hendrickson, Christopher L. , Marshall, Alan G. , Murray, David L., Anderson, Lissa C.

Journal of the American Society for Mass Spectrometry | February 28, 2017 | Volume: 28 | Issue: 5 | Pages: 827-838

10.1007/s13361-017-1602-6 | PMID 28247297 Get It

Effect of metastatic site biopsy on circulating tumor cell (CTC) count in castrate resistant prostate cancer (CRPC) stage.
Eiken, Patrick W. , McMenomy, Brendan P., Atwell, Thomas D. , Tan, Winston , Qin, Rui , Carlson, Rachel E. , Campion, Michael B., Wang, Liewei , Costello, Brian A. , Pitot, Henry C., Scheel, Elizabeth A, Paz‐Fumagalli, Ricardo , Moynihan, Timothy J. , Dronca, Roxana , Liu, Minetta C. , Kohli, Manish , Quevedo, Fernando , Ho, Thai H. , Bryce, Alan H.

Journal of Clinical Oncology | February 24, 2017 | Volume: 33 | Issue: 7_suppl | Pages: 190-190

10.1200/jco.2015.33.7_suppl.190 Get It

190 Background: It is not known if biopsy of CRPC stage metastases alters CTC results. We evaluated pre & post biopsy CTC counts in a prospective cohort undergoing pre-chemotherapy abiraterone acetate/prednisone (AA/P). Methods: CTC enumeration was performed on 7.5mL blood using the FDA cleared immunomagnetic/immunofluorescence assay (CellSearch). Time of blood draw for CTC counts pre/post biopsy was recorded for each biopsy. Biopsies were performed using 11/13 gauge core biopsy device for bone lesions and 18 gauge core needle biopsy device for soft tissue/nodal metastases. All patients (pts) underwent two serial biopsies 3 months apart. Change in CTC counts pre/post biopsy for visits 1 and 2 were evaluated using Wilcoxon signed rank test (significance at p<0.05). Differences in CTC count change (visit1) pre/post biopsy based on metastatic site (skeletal vs. non-skeletal) was compared using Wilcoxon rank-sum test. Results: Median age of the cohort was 74 years (IQR: 68-78); median PSA at V1 was 16.4 ng/ml (IQR: 6.4-87.6); at V2 was 11.5 ng/ml (IQR: 1.8-23.7). Of 59 pts undergoing biopsies 42 were in bone and 17 in nodal/soft tissue masses. At V1, pre/post biopsy CTC counts were measured on 50 and 49 pts, respectively; at V2, pre/post CTC counts were measured on 43 and 36 pts. High volume metastatic disease at V1 was observed in 67.8 % of all pts. Table lists CTC counts and time of collection pre/post biopsy for both visits. Mean change in pre/post biopsy CTC counts for skeletal sites was 0.7 (range: -12 to 64) compared to 12.1 (range: -21 to 13) for non-skeletal sites (p=0.23). Conclusions: An increase in mean CTC counts after biopsy of CRPC metastases was observed. No significant differences in change of CTC counts based on site biopsied (skeletal versus non-skeletal) was noted. Correlation with clinical outcomes is on-going. Clinical trial information: NCT# 01953640. [Table: see text]
Association Between Smoking Status, Preoperative Exhaled Carbon Monoxide Levels, and Postoperative Surgical Site Infection in Patients Undergoing Elective Surgery
Nolan, Margaret , Martin, David P. , Thompson, Rodney L., Schroeder, Darrell R. , Hanson, Andrew C. , Nolan, Margaret B, Thompson, Rodney, Warner, David O. , Nolan, Margaret B , Schroeder, Darrell

JAMA Surgery | February 15, 2017 | Volume: 152 | Issue: 5 | Pages: 476

10.1001/jamasurg.2016.5704 | PMID 28199450 Get It

Quantification of the IgG2/4 kappa Monoclonal Therapeutic Eculizumab from Serum Using Isotype Specific Affinity Purification and Microflow LC-ESI-Q-TOF Mass Spectrometry
Ladwig, Paula M. , Barnidge, David R. , Willrich, Maria A V, Willrich, Maria Alice V.

Journal of the American Society for Mass Spectrometry | December 21, 2016 | Volume: 28 | Issue: 5 | Pages: 811-817

10.1007/s13361-016-1566-y | PMID 28004336 Get It

Outcomes and Temporal Trends of Inpatient Percutaneous Coronary Intervention at Centers With and Without On-site Cardiac Surgery in the United States
Khera, Sahil , Bhatt, Deepak L. , Rihal, Charanjit S. , Goel, Kashish , Gupta, Tanush , Kolte, Dhaval , Fonarow, Gregg C. , Singh, Mandeep , Rihal, Charanjit S. , Bhatt, Deepak L

JAMA Cardiology | November 28, 2016 | Volume: 2 | Issue: 1 | Pages: 25

10.1001/jamacardio.2016.4188 | PMID 27893054 Get It

Site-specific proteolysis of mini-F plasmid replication protein RepE destroys initiator function and generates an incompatibility substance
Kline, B C, Sandhu, Gurpreet S. , Eckloff, Bruce W., Aleff, Ross A.

Journal of Bacteriology | November 7, 2016 | Volume: 174 | Issue: 9 | Pages: 3004-3010

10.1128/jb.174.9.3004-3010.1992 | PMID 1569028 Get It

Plasmid F replication is controlled by a plasmid-specified Rep protein with both autorepressor and initiator functions. The mechanism by which these two functions of a Rep protein are balanced to achieve stable replication is unknown; however, we speculated in prior work that Rep protein modification could be involved. We report here that naturally proteolyzed F RepE protein has been detected and characterized. The processed molecule lost the first 17 N-terminal aminoacyl residues and initiator function but acquired increased specific DNA-binding affinity in the presence of Escherichia coli chromosomal DNA. When supplied in trans, the altered protein acts as an incompatibility substance and eliminates maintenance of F'lac. These findings indicate that protein processing has the potential to contribute to the overall control of DNA replication.