Objectives: Music intervention has been shown to reduce anxiety and sedative exposure among mechanically ventilated patients. Whether music intervention reduces ICU costs is not known. The aim of this study was to examine ICU costs for patients receiving a patient-directed music intervention compared with patients who received usual ICU care. Design: A cost-effectiveness analysis from the hospital perspective was conducted to determine if patient-directed music intervention was cost-effective in improving patient-reported anxiety. Cost savings were also evaluated. One-way and probabilistic sensitivity analyses determined the influence of input variation on the cost-effectiveness. Setting: Midwestern ICUs. Patients: Adult ICU patients from a parent clinical trial receiving mechanical ventilatory support. Interventions: Patients receiving the experimental patient-directed music intervention received a MP3 player, noise-canceling headphones, and music tailored to individual preferences by a music therapist. Measurements and Main Results: The base case cost-effectiveness analysis estimated patient-directed music intervention reduced anxiety by 19 points on the Visual Analogue Scale-Anxiety with a reduction in cost of $2,322/patient compared with usual ICU care, resulting in patient-directed music dominance. The probabilistic cost-effectiveness analysis found that average patient-directed music intervention costs were $2,155 less than usual ICU care and projected that cost saving is achieved in 70% of 1,000 iterations. Based on break-even analyses, cost saving is achieved if the per-patient cost of patient-directed music intervention remains below $2,651, a value eight times the base case of $329. Conclusions: Patient-directed music intervention is cost-effective for reducing anxiety in mechanically ventilated ICU patients.
Textured Breast Implants: A Closer Look at the Surface Debris Under the Microscope
Background: Texturing of breast implants is done to decrease the risk of associated complications. Each manufacturer utilizes unique and at times proprietary techniques to texture the surface of their implants. Little is known about the integrity of this surface structure texturing or the propensity for the surfaces to shed particulate matter. This study aimed to determine the extent of surface particulate shedding from 3 textured implants approved by the US Food and Drug Administration (FDA), which are manufactured by Allergan, Mentor, and Sientra. Methods: Control images of each of the 3 textured breast implants were obtained with scanning electron microscopy (SEM). A liquid adhesive, ethylene vinyl acetate (EVA) copolymer was then applied to the external shell of the implants, allowed to cool, and peeled from the surface. Images of the EVA copolymer were taken with SEM to qualitatively analyze displacement of surface particulate debris. Scanning electron microscopy imaging of the implants was repeated for qualitative comparisons with the control images. Results: The peeled copolymer of the 3 implants exhibited surface shedding. Comparison of the 3 breast implants showed the shedding to be greatest for the Allergan implant. Conclusions: This study highlights the dynamic surface material properties of the 3 FDA-approved breast implants. Shedding of particulate matter from the implant surfaces can be precipitated by moderate adhesion. Our qualitative examination of SEM findings showed more debris shed from the Allergan breast implants than from the Mentor or Sientra implants.
Impact of a Shared Decision Making Intervention on Health Care Utilization: A Secondary Analysis of the Chest Pain Choice Multicenter Randomized Trial
AbstractBackgroundPatients at low risk for acute coronary syndrome are frequently admitted for observation and cardiac testing, resulting in substantial burden and cost to the patient and the health care system.ObjectivesThe purpose of this investigation was to measure the effect of the Chest Pain Choice (CPC) decision aid on overall health care utilization as well as utilization of specific services both during the index emergency department (ED) visit and in the subsequent 45 days.MethodsThis was a planned secondary analysis of data from a pragmatic multicenter randomized trial of shared decision making in adults presenting to the ED with chest pain who were being considered for observation unit admission for cardiac stress testing or coronary computed tomography angiography. The trial compared an intervention group engaged in shared decision making facilitated by the CPC decision aid to a control group receiving usual care. Hospital‐level billing data were used to measure utilization for the index ED visit and during the following 45 days. Patients in both groups also were asked to keep a diary recording health care utilization over the same 45‐day period. Outcomes assessed included length of time in the ED and observation, ED visits, office visits, hospitalizations, testing, imaging, and procedures.ResultsOf the 898 patients included in the original trial, we were able to contact 834 (92.9%) patients for 45‐day health care diary review. There was no difference in patient‐reported health care utilization between the study arms. Hospital‐level billing data were obtained for all 898 (100%) patients. During the initial ED visit the length of stay (LOS) was similar, and there was no difference in the frequency of observation unit admission between study arms. However, the mean observation unit LOS was 95 minutes (95% confidence interval [CI] = 40.8–149.8) shorter in the CPC arm and the mean number of tests was lower in the CPC arm (decrease in 19.4 imaging studies per 100 patients, 95% CI = 15.5–23.3). When evaluating the entire encounter and follow‐up period, the intervention arm underwent fewer tests (decrease in 125.6 tests per 100 patients, 95% CI = 29.3–221.6). More specifically, there were fewer advanced cardiac imaging tests completed (25.8 fewer per 100 patients, 95% CI = 3.74–47.9) in the intervention arm.ConclusionsShared decision making in low‐risk chest pain can lead to decreased diagnostic testing without worsening outcomes measured over 45 days.
Craniosynostosis Surgery and the Impact of Tranexamic Acid Dosing
Abstract Consensus does not exist regarding the best dosage regimen for using tranexamic acid (TXA) for patients undergoing open calvarial vault remodeling in craniosynostosis surgery. The purpose of this study was to evaluate 2 dosing protocols, as well as the cost of using TXA. Previously, the institutional protocol was to give patients undergoing open calvarial vault remodeling a loading infusion of TXA (10 mg/kg) at the start of their procedure, after which intravenous TXA (5 mg/kg/h) was given throughout surgery and for 24 hours postoperatively. In July 2015, the protocol changed to a reduced postoperative infusion time of 4 hours. A retrospective review was conducted of records of 30 patients who had surgery before the protocol change (24-hour group) and 23 patients whose surgery occurred after the protocol change (4-hour group). The following data were collected: blood volume transfused, hemoglobin levels, estimated blood loss, and intensive care days; and costs of TXA and blood transfusion. Results showed a 4-hour infusion was as effective as a 24-hour infusion for reducing blood loss in patients undergoing craniosynostosis. Transfusion requirements, hemoglobin and hematocrit levels, and estimated blood loss were not significantly different for the groups. The cost of TXA and transfusion in the 4-hour group was significantly less (P < 0.001) than in the 24-hour group. No significant difference in cost existed for patients who received blood transfusion alone versus patients who received the 4-hour TXA infusion.
Optimizing Emergency Department Workflow Using Radio Frequency Identification Device (RFID) Data Analytics
Emergency Department (ED) is a complex care delivery environment in a hospital that provides time sensitive urgent and lifesaving care [1]. Emergency medicine is an unscheduled practice and therefore providers experience extreme fluctuations in their workload. ED crowding is a major concern that affects the efficacy of the ED workflow, which often is challenged by long wait times, overuse of observation units, patients either leaving without being seen by a provider and non-availability of inpatient beds to accommodate patients after diagnosis [2]. Evaluating ED workflow is a challenging task due to its chaotic nature, with some success using time-motion studies and novel capacity management tools are nowadays becoming common in ED to address workflow related issues [3]. Several studies reveal that Electronic Medical Record (EMR) adoption has not resulted in significant ED workflow improvements nor reduced the cost of ED operations. Since raw EMR data does not offer operational and clinical decision making insights, advanced EMR data analytics are often sought to derive actionable intelligence from EMR data that can provide insights to improve ED workflow. Improving ED workflow has been an important topic of research because of its great potential to optimize the urgent care needed for the patients and at the same time save time and cost. Radio Frequency Identification Device (RFID) is a wireless automatic identification and data capture technology device that has the potential for improving safety, preventing errors, saving costs, and increasing security and therefore improving overall organizational performance. RFID technology use in healthcare has opened a new space in healthcare informatics research that provides novel data to identify workflow process pitfalls and provide new directions [4]. The potential advantages of RFID adoption in healthcare and especially in ED has been well recognized to save costs and improve care delivery [5]. However, the large upfront infrastructure costs, need for an integrated health information technology (HIT), advanced analytical tools for big data analysis emerging from RFID and skilled data scientists to tackle the data to derive actionable intelligence discourage many hospitals from adoption RFID technology despite its potential advantages. Our recent pilot study on the RFID data analytics demonstrated the feasibility of quantifying and analyzing two novel variables such as ‘patient alone’ time defined as the total time a patient spends alone without interaction with a health care staff in the ED and ‘provider time’ defined as the total time a patient spends interacting with any health care staff [6]. The study motivated a more comprehensive big data analytics of RFID data which can provide better insights into optimizing ED workflow which can improve the quality of care in the ED and also reduce cost. In this work, the authors attempt to describe the RFID adoption in the ED at the Saint Mary’s Hospital at Mayo Clinic, in Rochester, MN, a level one trauma center both for children and adults as a step towards optimizing ED workflow.
Overall survival in patients with glioblastoma before and after bevacizumab approval
PEComas represent a family of uncommon mesenchymal tumors composed of “perivascular epithelioid cells” with a distinct immunophenotype that typically shows both myogenic and melanocytic differentiation. The PEComa family includes angiomyolipoma (AML), clear cell “sugar” tumor of the lung and extra pulmonary sites, lymphangioleiomyomatosis and clear cell myomelanocytic tumor of the falciform ligament/ligamentum teres. Very rarely, PEComas may arise in the skin. Primary cutaneous PEComas typically display a dermal proliferation of epithelioid cells with pale, clear, or granular pink cytoplasm arranged in nests and trabecula with an intervening arborizing network of delicate capillaries. Primary cutaneous PEComas have a lower frequency of myogenic marker expression than their deep soft tissue and visceral counterparts. They also often express strong diffuse CD10, leading to potential confusion with metastatic renal cell carcinoma. Most cases behave indolently. We report 5 additional cases of this rare entity. All showed classic histologic features and expression of either HMB‐45 and/or Melan‐A/MART‐1. Four cases were tested for myogenic markers (2 were positive & 2 were negative). Three cases were tested for CD10 (all 3 were positive). All of our cases with clinical follow‐up behaved indolently. Table 1 provides a summary of findings for all 5 cases in our series.