Background: Texturing of breast implants is done to decrease the risk of associated complications. Each manufacturer utilizes unique and at times proprietary techniques to texture the surface of their implants. Little is known about the integrity of this surface structure texturing or the propensity for the surfaces to shed particulate matter. This study aimed to determine the extent of surface particulate shedding from 3 textured implants approved by the US Food and Drug Administration (FDA), which are manufactured by Allergan, Mentor, and Sientra. Methods: Control images of each of the 3 textured breast implants were obtained with scanning electron microscopy (SEM). A liquid adhesive, ethylene vinyl acetate (EVA) copolymer was then applied to the external shell of the implants, allowed to cool, and peeled from the surface. Images of the EVA copolymer were taken with SEM to qualitatively analyze displacement of surface particulate debris. Scanning electron microscopy imaging of the implants was repeated for qualitative comparisons with the control images. Results: The peeled copolymer of the 3 implants exhibited surface shedding. Comparison of the 3 breast implants showed the shedding to be greatest for the Allergan implant. Conclusions: This study highlights the dynamic surface material properties of the 3 FDA-approved breast implants. Shedding of particulate matter from the implant surfaces can be precipitated by moderate adhesion. Our qualitative examination of SEM findings showed more debris shed from the Allergan breast implants than from the Mentor or Sientra implants.
Craniosynostosis Surgery and the Impact of Tranexamic Acid Dosing
Abstract Consensus does not exist regarding the best dosage regimen for using tranexamic acid (TXA) for patients undergoing open calvarial vault remodeling in craniosynostosis surgery. The purpose of this study was to evaluate 2 dosing protocols, as well as the cost of using TXA. Previously, the institutional protocol was to give patients undergoing open calvarial vault remodeling a loading infusion of TXA (10 mg/kg) at the start of their procedure, after which intravenous TXA (5 mg/kg/h) was given throughout surgery and for 24 hours postoperatively. In July 2015, the protocol changed to a reduced postoperative infusion time of 4 hours. A retrospective review was conducted of records of 30 patients who had surgery before the protocol change (24-hour group) and 23 patients whose surgery occurred after the protocol change (4-hour group). The following data were collected: blood volume transfused, hemoglobin levels, estimated blood loss, and intensive care days; and costs of TXA and blood transfusion. Results showed a 4-hour infusion was as effective as a 24-hour infusion for reducing blood loss in patients undergoing craniosynostosis. Transfusion requirements, hemoglobin and hematocrit levels, and estimated blood loss were not significantly different for the groups. The cost of TXA and transfusion in the 4-hour group was significantly less (P < 0.001) than in the 24-hour group. No significant difference in cost existed for patients who received blood transfusion alone versus patients who received the 4-hour TXA infusion.