Citations

Mayo Clinic

Clear

12 citation(s) found for "Providencia, Rui".

Quality indicators for the care and outcomes of adults with atrial fibrillation
Arbelo, Elena , (Chair), Drossart, Inga , Dwight, Jeremy, Hills, Mellanie True , Hindricks, Gerhard , Lane, Deirdre A. , Lau, Dennis H. , Lettino, Maddalena , Lobban, Trudie , Pak, Hui‐Nam , Potpara, Tatjana , Sáenz, Luis Carlos , Gelder, Isabelle C. Van , Varosy, Paul D. , Gale, Chris P , Dagres, Nikolaos , (Co-chair), Reviewers, coordinator), (review, Defaye, Pascal , Lenarczyk, Radosław , Providência, Rui , Palmero, María José Guerra , Takahashi, Yoshihide , Sarkozy, Andrea , Glotzer, Taya V. , Kusumoto, Fred M, Dagres, Nikolaos , Providencia, Rui , Arbelo, Elena , Lane, Deirdre A , (Chair), Aktaa, Suleman , Bollmann, Andreas , d'Avila, Andre , Kusumoto, Fred , Lip, Gregory Y H , (Co-chair), Reviewers, Bovéda, Serge , coordinator), (review, Deneke, Thomas , Conte, Giulio , Pisani, Cristiano , Nava, Santiago , Oliveira, Mário

EP Europace | August 31, 2020 | Volume: 23 | Issue: 4 | Pages: 494-495

10.1093/europace/euaa253 | PMID 32860039 Get It

Abstract Aims To develop quality indicators (QIs) that may be used to evaluate the quality of care and outcomes for adults with atrial fibrillation (AF). Methods and results We followed the ESC methodology for QI development. This methodology involved (i) the identification of the domains of AF care for the diagnosis and management of AF (by a group of experts including members of the ESC Clinical Practice Guidelines Task Force for AF); (ii) the construction of candidate QIs (including a systematic review of the literature); and (iii) the selection of the final set of QIs (using a modified Delphi method). Six domains of care for the diagnosis and management of AF were identified: (i) Patient assessment (baseline and follow-up), (ii) Anticoagulation therapy, (iii) Rate control strategy, (iv) Rhythm control strategy, (v) Risk factor management, and (vi) Outcomes measures, including patient-reported outcome measures (PROMs). In total, 17 main and 17 secondary QIs, which covered all six domains of care for the diagnosis and management of AF, were selected. The outcome domain included measures on the consequences and treatment of AF, as well as PROMs. Conclusion This document defines six domains of AF care (patient assessment, anticoagulation, rate control, rhythm control, risk factor management, and outcomes), and provides 17 main and 17 secondary QIs for the diagnosis and management of AF. It is anticipated that implementation of these QIs will improve the quality of AF care.
Time trends in sudden cardiac death risk in heart failure patients with cardiac resynchronization therapy: a systematic review
Barra, Sérgio , Providência, Rui , Narayanan, Kumar , Boveda, Serge , Duehmke, Rudolf , Garcia, Rodrigue , Leyva, Francisco , Roger, Véronique L. , Jouven, Xavier , Agarwal, Sharad , Levy, Wayne C. , Marijon, Éloi , Providencia, Rui , Garcia, Rodrigue , Boveda, Serge

European Heart Journal | October 25, 2019 | Volume: 41 | Issue: 21 | Pages: 1976-1986

10.1093/eurheartj/ehz773 | PMID 31750896 Get It

Abstract Aims While data from randomized trials suggest a declining incidence of sudden cardiac death (SCD) among heart failure patients, the extent to which such a trend is present among patients with cardiac resynchronization therapy (CRT) has not been evaluated. We therefore assessed changes in SCD incidence, and associated factors, in CRT recipients over the last 20 years. Methods and results Literature search from inception to 30 April 2018 for observational and randomized studies involving CRT patients, with or without defibrillator, providing specific cause-of-death data. Sudden cardiac death was the primary endpoint. For each study, rate of SCD per 1000 patient-years of follow-up was calculated. Trend line graphs were subsequently constructed to assess change in SCD rates over time, which were further analysed by device type, patient characteristics, and medical therapy. Fifty-three studies, comprising 22 351 patients with 60 879 patient-years of follow-up and a total of 585 SCD, were included. There was a gradual decrease in SCD rates since the early 2000s in both randomized and observational studies, with rates falling more than four-fold. The rate of decline in SCD was steeper than that of all-cause mortality, and accordingly, the proportion of deaths which were due to SCD declined over the years. The magnitude of absolute decline in SCD was more prominent among CRT-pacemaker (CRT-P) patients compared to those receiving CRT-defibrillator (CRT-D), with the difference in SCD rates between CRT-P and CRT-D decreasing considerably over time. There was a progressive increase in age, use of beta-blockers, and left ventricular ejection fraction, and conversely, a decrease in QRS duration and antiarrhythmic drug use. Conclusion Sudden cardiac death rates have progressively declined in the CRT heart failure population over time, with the difference between CRT-D vs. CRT-P recipients narrowing considerably.