Background: Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe. Methods: The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria. Results: Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50–70 minutes) of procedure time, 3.4 minutes (IQR 2.4–5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3–6) RF lesions. Αn escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8–15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5–14 months) of follow-up. Conclusion: Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation.
Time trends in sudden cardiac death risk in heart failure patients with cardiac resynchronization therapy: a systematic review
Abstract Aims While data from randomized trials suggest a declining incidence of sudden cardiac death (SCD) among heart failure patients, the extent to which such a trend is present among patients with cardiac resynchronization therapy (CRT) has not been evaluated. We therefore assessed changes in SCD incidence, and associated factors, in CRT recipients over the last 20 years. Methods and results Literature search from inception to 30 April 2018 for observational and randomized studies involving CRT patients, with or without defibrillator, providing specific cause-of-death data. Sudden cardiac death was the primary endpoint. For each study, rate of SCD per 1000 patient-years of follow-up was calculated. Trend line graphs were subsequently constructed to assess change in SCD rates over time, which were further analysed by device type, patient characteristics, and medical therapy. Fifty-three studies, comprising 22 351 patients with 60 879 patient-years of follow-up and a total of 585 SCD, were included. There was a gradual decrease in SCD rates since the early 2000s in both randomized and observational studies, with rates falling more than four-fold. The rate of decline in SCD was steeper than that of all-cause mortality, and accordingly, the proportion of deaths which were due to SCD declined over the years. The magnitude of absolute decline in SCD was more prominent among CRT-pacemaker (CRT-P) patients compared to those receiving CRT-defibrillator (CRT-D), with the difference in SCD rates between CRT-P and CRT-D decreasing considerably over time. There was a progressive increase in age, use of beta-blockers, and left ventricular ejection fraction, and conversely, a decrease in QRS duration and antiarrhythmic drug use. Conclusion Sudden cardiac death rates have progressively declined in the CRT heart failure population over time, with the difference between CRT-D vs. CRT-P recipients narrowing considerably.