Citations

Mayo Clinic

Clear

3026 citation(s) found for "Ha, Kevin".

Improved Visualization of Middle Ear Prostheses using Photon-Counting Detector CT: A Cadaver Study
Sadeghian, Maryam, Benson, John C. , Lane, John I. , Treb, Kevin , Khandalavala, Karl R. , Babajanian, Eric E. , Bruesewitz, Michael R. , Swicklik, Joseph R., Ou, Fang‐Shu , McCollough, Cynthia H, Carlson, Matthew L, Leng, Shuai, Ou, Fang-Shu , Sadeghian, Maryam , Farnsworth, Paul J. , McCollough, Cynthia H. , Carlson, Matthew L. , Leng, Shuai

Radiology Advances | September 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/radadv/umag041 Get It

Abstract Background Evaluation of middle ear prostheses requires high-resolution imaging to assess position and structural integrity. Purpose To assess the diagnostic performance of photon-counting-detector (PCD)-CT for middle ear prosthesis imaging in cadaveric specimens. Materials and Methods Nine different middle ear prostheses were implanted in five fresh-frozen whole-head specimens, both in correct anatomic position and displaced to mimic malposition. Specimens were scanned on PCD-CT (NAEOTOM Alpha, Siemens) and energy-integrating-detector (EID)-CT (SOMATOM Force, Siemens), reconstructed at 0.2mm and 0.4mm, respectively. Eighteen cases (9 prostheses, 2 positions) per scanner were evaluated by two neuroradiologists (36 readings), blinded to scanner and position, who scored prosthesis position, reader confidence, and overall image quality. Agreement with the reference standard and between readers was compared. Results PCD-CT showed higher diagnostic confidence compared with EID-CT, while accuracy and inter-reader agreement did not demonstrate significant differences between scanners. Correct readings, PCD-CT versus EID-CT: lateral contact, 31/36 (86.1%; 95% CI: 58.3%-94.4%) vs. 29/36 (80.6%; 55.6%-91.7%), p = 0.500; medial contact, 30/36 (83.3%; 55.6%-94.4%) vs. 26/36 (72.2%; 50.0%-83.3%), p = 0.250. PCD-CT identified all cases of complete contact loss (score 3), while EID-CT missed one reading per contact. Inter-reader agreement may be higher with PCD-CT vs EID-CT (lateral: κw: 0.804 [0.578-0.941] vs. 0.571 [0.302-0.778], p = 0.250; medial: 0.684 [0.191-0.934] vs. 0.481 [0.024-0.835], p = 0.250). Reader confidence was significantly higher with PCD-CT; mean paired differences for Readers 1 and 2 were 9.4 (1.8-17.1; Holm-adjusted p = 0.019) and 23.1 points (13.4-32.7; p < 0.001) for lateral contact, and 16.4 (10.0-22.8; p < 0.001) and 17.8 points (6.8-28.8; p = 0.007) for medial contact. Readers preferred PCD-CT image quality in 16/18 (88.9%; 65.3%-98.6%) and 17/18 cases (94.4%; 72.7%-99.9%), respectively. Conclusion PCD-CT was associated with significantly higher reader confidence and preferred image quality, without significant differences in diagnostic accuracy or inter-reader agreement. These findings suggest PCD-CT is a promising modality for postoperative middle ear evaluations that warrants further investigations.
Supporting frontline staff in frontotemporal degeneration research
Dodge, Shana , Carter, D., Kamel, Dahlia, Lunde, Angela, Hlava, Quinn, Nelson, Kevin, Lunde, Angela , Nelson, Kevin M., Dacks, Penny A.

Frontiers in Neurology | September 11, 2026 | Volume: 17 | Issue: No issue available | Pages: No page available

10.3389/fneur.2026.1906002 | PMID 42798361 Get It

Introduction Clinical Research Coordinators (CRCs) serve as the frontline staff for research participants in studies on frontotemporal degeneration (FTD), directly influencing participant experience. The training adequacy, job satisfaction, and retention of FTD CRCs have not been systematically examined. Methods The Association for Frontotemporal Degeneration (AFTD) administered an anonymous cross-sectional online survey to CRCs affiliated with research networks across the USA and Canada. Results Thirty-seven CRCs responded. Most had more than 3 years of experience, yet 62% reported encountering situations for which they felt inadequately prepared. Information on genetics, symptom management, and brain donation were identified as critical training gaps. Retention was linked to competitive pay and clear career advancement opportunities. Discussion The findings highlight a critical need for formalized, disease-specific onboarding and emotional support systems tailored to CRCs that engage with FTD patients and families. AFTD is developing a modular training curriculum to standardize CRC competency.
Model-based motion simulation framework for deep learning-assisted motion correction in dynamic wrist CT
Zhao, Kristin D. , Treb, Kevin , Gu, Chunming , Davis, Aeden K , Huang, Shengbing, Treb, Kevin , Trentadue, Taylor P , Sadeghian, Maryam , Baffour, Francis , Trentadue, Taylor P , Leng, Shuai , Gong, Hao , Gu, Chunming , Thoreson, Andrew R. , Lachman, Nirusha , Baffour, Francis, Trentadue, Taylor P. , Kakar, Sanjeev , McCollough, Cynthia H, Leng, Shuai , Gong, Hao

Physics in Medicine & Biology | September 11, 2026 | Volume: 71 | Issue: 18 | Pages: 185014

10.1088/1361-6560/aea684 | PMID 42727609 Get It

Abstract Objective. Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted ( α = 0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference ( p > 0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55 ± 0.12–0.75 ± 0.04 and SSIM from 0.87 ± 0.08–0.95 ± 0.03 at bone regions (each p < 0.01). In experimental cadaveric scans, LIRS improved from 0.05 ± 0.01–0.31 ± 0.17 in marker regions and from 0.58 ± 0.19–0.77 ± 0.14 in bone regions (each p < 0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement.
Beyond transfusions: bleeding-related outcomes after repeat TURP
Liu, Eric, Lange, Dirk , Bhojani, Naeem, Wymer, Kevin, Forbes, Connor M. , Derigs, Marcus , Bhojani, Naeem , Forbes, Connor M.

No container title available | September 10, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-10532565/v1 Get It

Abstract Purpose We compared perioperative morbidity after repeat transurethral resection (re-TURP) versus primary TURP, focusing on transfusion and broader bleeding-related complications relevant to counseling and risk stratification. Methods We analyzed the American College of Surgeons National Surgical Quality Improvement Program (2013–2023) to identify men undergoing primary TURP (Current Procedural Terminology [CPT] 52601) or re-TURP (CPT 52630). The primary outcome was 30-day red blood cell transfusion. Secondary outcomes included a prespecified postoperative hematuria endpoint based on ICD-10 codes. Multivariable logistic regression evaluated associations with bleeding endpoints and downstream complications. Results Among 83,539 TURP procedures, 76,983 (92.2%) were primary and 6,556 (7.8%) were repeat. Re-TURP patients were older, had higher ASA class, and more often underwent urgent surgery. Transfusion occurred in 1.9% after re-TURP versus 1.5% after primary TURP; hematuria-coded events occurred in 3.5% versus 1.3%, respectively. After adjustment, re-TURP was associated with postoperative hematuria (adjusted odds ratio [aOR] 2.42, 95% CI 2.03–2.88) but not with transfusion (aOR 1.09, 95% CI 0.87–1.36). Older age, urgent/emergent status, bleeding disorder, and lower hematocrit predicted both bleeding endpoints. Re-TURP was associated with slightly lower odds of readmission (aOR 0.87; 95% CI 0.76–0.99) and was not associated with return to the operating room. Transfusion strongly predicted return to the operating room (aOR 7.21) and readmission (aOR 2.05), whereas hematuria predicted return to the operating room only (aOR 1.50). Conclusions Compared with primary TURP, re-TURP was associated with more hematuria-coded events but not higher adjusted transfusion risk, suggesting a relative shift toward lower-severity bleeding morbidity.
Five-year survival and complications of more than 300 articulating high-dose antibiotic spacers in two-stage revision total hip arthroplasties for infection
Weintraub, Matthew T. , Midthun, William R., Pagnano, Mark W., Taunton, Michael J. , Sierra, Rafael J. , Mabry, Tad M. , Perry, Kevin I. , Abdel, Matthew P. , Abdel, Matthew P , Sierra, Rafael J , Taunton, Michael J , Pagnano, Mark W. , Berry, Daniel J.

The Bone & Joint Journal | September 1, 2026 | Volume: 108-B | Issue: 9 | Pages: 1104-1112

10.1302/0301-620x.108b9.bjj-2026-0551.r1 | PMID 42674571 Get It

Aims Two-stage exchange arthroplasty with an antibiotic-eluting cement spacer remains the predominant strategy in the USA for managing chronic periprosthetic joint infection (PJI) following total hip arthroplasty (THA). The aim of this study was to evaluate a commercially available, partially intraoperatively fabricated articulating high-dose antibiotic cement spacer, focusing on survival, complications, and patient-reported outcomes. Methods A total of 298 patients (302 THAs) underwent two-stage exchange arthroplasty for PJI using a specific articulating antibiotic spacer between August 2005 and May 2022. Patients with a previous failed two-stage exchange were excluded, although 121 THAs (302, 40%) had undergone previous PJI-related procedures. The mean age of the patients was 65 years (SD 11), the mean BMI was 32 kg/m 2 (SD 7), and 116 (38%) were female. Most patients were classified as McPherson host B (158; 52%) and limb grade 2 (165; 55%), and 265 (88%) met the 2011 Musculoskeletal Infection Society criteria. The mean follow-up was six years (2 to 16). Results At five years after reimplantation, survival free of reinfection, aseptic rerevision, any rerevision, or any reoperation were 89% (95% CI 85.2 to 93.1), 93% (95% CI 89.3 to 96.1), 86% (95% CI 81.3 to 90.3), and 80% (95% CI 74.7 to 84.9), respectively. Dislocation accounted for most aseptic rerevisions (15/20). McPherson host C (HR 3.7 (95% CI 1.4 to 9.6); p = 0.007) and limb grade 3 (HR 3.3 (95% CI 1.0 to 11.1); p = 0.049) were significantly associated with an increased risk of reinfection. The mean Harris Hip Score at the latest follow-up was 76 (29 to 100). A total of 17 patients underwent revision or removal of a spacer for concerns about persistent infection and two for dislocation of the spacer. Eight patients underwent a non-rerevision reoperation during the spacer interval for wound drainage (n = 5), dislocation of the spacer (n = 2), and perispacer fracture (n = 1). A total of 26 spacer-related complications were treated nonoperatively (15 perispacer fractures, 11 dislocations). Dislocation of the spacer was strongly associated with dislocation after reimplantation (HR 6.2 (95% CI 2.3 to 16.9); p < 0.001). Conclusion This commercially available, partially intraoperatively fabricated articulating spacer showed excellent reinfection-free five-year survival (89%). Spacer-related fracture and dislocation each occurred in 5% of patients. Dislocation of the spacer significantly increased the risk of dislocation following reimplantation, supporting the use of higher-stability bearings in these high-risk patients. Cite this article: Bone Joint J 2026;108-B(9):1104–1112.
Prognostic Value of Artificial Intelligence ECG–Derived Diastolic Function in Surgical Aortic Valve Replacement
Sawma, Tedy , Schaff, Hartzell V. , Danesh, Sina , Arghami, Arman , Lee, Eunjung , Aslahishahri, Masoomeh, Stulak, John, Greason, Kevin L. , Dearani, Joseph A. , López-Jiménez, Francisco , Friedman, Paul A. , Oh, Jae K. , Dearani, Joseph A. , Greason, Kevin , Sabbah, Michael S. , Attia, Zachi I , Oh, Jae K. , Crestanello, Juan A , Lopez-Jimenez, Francisco , Arghami, Arman , Schaff, Hartzell , Stulak, John M., Pislaru, Sorin V. , Attia, Zachi I. , Crestanello, Juan A.

Journal of the American Heart Association | August 31, 2026 | Volume: 15 | Issue: 19 | Pages: No page available

10.1161/jaha.126.050492 | PMID 42669926 Get It

Background Diastolic dysfunction is common in patients with aortic stenosis and may influence outcomes following surgical aortic valve replacement. We aimed to examine the association of preoperative artificial intelligence (AI)‐generated diastolic function grades with early and late outcomes following aortic valve replacement and how postoperative progression influence prognosis. Methods We identified 5503 patients undergoing aortic valve replacement between 2000 and 2023. Diastolic function was assessed using a validated deep‐learning AI model applied to 12‐lead ECGs done preoperatively and on postoperative follow‐up. Diastolic grades were classified by AI into Grades 1 to 3. Longitudinal trend analyses and multivariable regression models were used to assess study end points. Results Among 5503 patients (mean age 72.4±10.8 years; 39% female), higher AI ECG diastolic grades were associated with greater comorbidity burden, including diabetes, renal disease, and heart failure. AI ECG diastolic Grade 3 was independently associated with higher in‐hospital mortality (odds ratio, 2.5; P =0.007) and other complications. At 5‐year follow‐up, patients with Grade 3 showed the least improvement in diastolic function by both ECG and echocardiography. Grades 2 and 3 diastolic function at baseline were independently associated with increased late mortality (hazard ratio, 1.3 and 2.45, respectively; both P <0.001). Additionally, lack of improvement in AI ECG diastolic grade by 1 year was also independently associated with late mortality. Conclusions AI ECG–derived diastolic function grades strongly correlates with early complications and long‐term mortality and diastolic progression after aortic valve replacement. AI ECG provides a powerful, noninvasive tool for risk stratification and longitudinal monitoring of patients with aortic stenosis.
Kidney-alone transplantation in prior SLK candidates: a national registry analysis
Harris, Kevin B., Smith, Byron, Pereyra, David, Benavides, Xiomara , Olson, Jody, Taner, Timucin, Simonetto, Douglas A., Cortez, Alexander R. , Riad, Samy M. , Moeckli, Beat , Olson, Jody C. , Taner, Timuçin , Heimbach, Julie K. , Simonetto, Douglas A. , Riad, Samy

Transplant International | August 27, 2026 | Volume: 39 | Issue: No issue available | Pages: No page available

10.3389/ti.2026.16834 | PMID 42723848 Get It

Outcomes of kidney-alone transplantation (KAT) in former simultaneous liver-kidney (SLK) transplant candidates after liver waitlist delisting are not well defined. Using Scientific Registry of Transplant Recipients (SRTR) data, we identified adult recipients who underwent KAT between 2005 and 2025 after prior SLK listing (RLD-KAT), which was matched 1:5 to primary KAT recipients without liver disease by age, transplant year, and diabetes status. Patient and graft survival were evaluated using the Kaplan-Meier method and multivariable Cox proportional hazards models. We identified 163 RLD-KAT recipients matched to 815 controls. Unadjusted Kaplan-Meier analyses demonstrated lower patient survival in RLD-KAT (p = 0.020), whereas death-censored and overall graft survival were similar (p &gt; 0.05). In multivariable models, death-censored graft survival (HR 0.89; 95% CI 0.51–1.53), overall graft survival (HR 1.00; 95% CI 0.73–1.36), and patient survival (HR 1.07; 95% CI 0.76–1.5) did not differ significantly. Six RLD-KAT recipients (3.7%) subsequently underwent liver transplantation. Kidney-alone transplantation in prior SLK candidates was associated with acceptable patient and graft outcomes and a low incidence of subsequent liver transplantation.
Initial Staging 18 F-FDG PET/CT for Coronary Artery Calcium Scoring to Assess Cardiovascular Risk in Women with Breast Cancer
Fleming, Matthew R. , Tayon, Kevin G., McPherson, Alyssa, Bianco, Sidney M., Lin, Grace , Norton, Nadine , Ray, Jordan , Lin, Grace , Norton, Nadine , Tayon, Kevin G. , Schneider, Artur , Parent, Ephraim E. , Sharma, Akarsh

No container title available | August 26, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.08.24.26361275 Get It

Abstract Background. Cardiovascular disease is a leading cause of death among women with breast cancer, and the 2026 ACC/AHA dyslipidemia guideline endorses coronary artery calcium (CAC) scoring to guide statin therapy before cardiotoxic treatment. Breast cancer patients routinely undergo staging 18 F-fluorodeoxyglucose PET/CT, whose low- dose CT visualizes the coronary arteries, thus enabling CAC quantification at no additional cost or radiation. Methods In this single-center retrospective study, consecutive women with newly diagnosed breast cancer undergoing staging 18 F-FDG PET/CT (2009–2021) had semi- automated Agatston CAC scoring performed on the low-dose CT and were stratified by CAC presence (CAC-P) versus absence (CAC-A). We assessed a composite of cardiac diagnostic testing (stress testing, coronary CT angiography, invasive angiography), clinical events, and reclassification of statin eligibility per ACC/AHA guideline thresholds in a prevention-eligible subgroup. Results Among 276 women (mean age 55.5 years; median follow-up 7.1 years), CAC was present in 68 (25%) but was clinically reported in only 5.4%. CAC-P was associated with more cardiac testing (34% vs 12%; age-adjusted hazard ratio 2.75, 95% CI 1.43–5.28) and, though underpowered, with more atherosclerotic events (7.4% vs 1.4%), but not with the all-cause composite. In the prevention-eligible subgroup (n=39), CAC scoring would have changed statin eligibility in 64%, initiating therapy in 62% of CAC-P women and supporting de-prescribing in 67% of CAC-A women. Conclusions CAC can be feasibly quantified from staging PET/CT in women with breast cancer and would frequently reclassify statin eligibility at no additional cost or radiation, yet is rarely reported.
T-cell immunosenescence limits CD19 CAR T-cell function in chronic lymphocytic leukemia
Noll, Julia Han , Dersh, Devin , Li, Jiang Yuan, Hemani, Humza , Lavorando, Maya, Bartoszek, Robert, Amses, Kevin R. , Jain, Ankita , Minehart, Janna , Shestov, Max A, Camerini, Elena , Loren, Alison W., Woyach, Jennifer A. , Goronzy, Jorg Josef, Kater, Arnon P. , Porter, David L., Bushman, Frederic D, Levine, Bruce L. , June, Carl H. , Long, Meixiao, Weng, Nan‐ping , Diorio, Caroline, Ramirez-Fernandez, Angel , Paruzzo, Luca , Camerini, Elena , Peters, Fleur S , Huang, Xiao , Woyach, Jennifer A , Kater, Arnon P , Ruella, Marco , Byrd, John C , Schuster, Stephen J , Siegel, Donald L , Levine, Bruce L , June, Carl H , Frey, Noelle V , Cohen, Adam D , Garfall, Alfred L , Long, Meixiao , Maus, Marcela V , Weng, Nan-Ping , Fraietta, Joseph A , Bartoszek, Robert L. , Ho, Matthew , Paruzzo, Luca , Shestov, Max, Loren, Alison W. , Goronzy, Jörg J. , Ruella, Marco , Byrd, John C. , Powell, Daniel J. , Gill, Saar , Porter, David L. , Schuster, Stephen J. , Bushman, Frederic D. , Frey, Noelle V. , Cohen, Adam D. , Garfall, Alfred L. , Diorio, Caroline J.

Blood Journal | August 24, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1182/blood.2025032274 | PMID 42636161 Get It

CD19-directed CAR T-cells (CTL019) can produce durable remissions in chronic lymphocytic leukemia (CLL), but therapeutic success depends on whether autologous T-cells expand, persist, and retain cytotoxic function after manufacturing. Failure of CLL T-cells is often attributed to exhaustion, although many dysfunctional CLL T-cells retain inflammatory cytokine production. We tested whether this paradox reflects immunosenescence, an aging-like program defined by costimulatory loss, DNA damage, inflammatory secretion, repertoire restriction, and proliferative arrest. In response-linked preinfusion CTL019 products, nonresponders and short partial responders had higher senescence and senescence-associated secretory phenotype (SASP) programs than the functional-responder group, comprising complete responders and partial responders with transformed disease. These programs were detectable before infusion and became more prominent during manufacture in susceptible products. They tracked with weak in vivo CAR T-cell expansion and were associated with inferior survival. Serum proteomics revealed a circulating, CLL-associated SASP-like inflammatory milieu in nonresponders. Flow cytometry and T-cell receptor (TCR) profiling showed that poor responders carried CD27⁻CD28⁻ and KLRG1⁺ CD8 T-cells at apheresis, lower product CD27, and reduced product TCR diversity. Research-manufactured CAR T-cells from treatment-naïve CLL samples displayed the same state, most prominently in CD4 CAR T-cells, with SA-β-gal, p16, p53, DNA damage, depletion of less-differentiated states, and senescence-enriched transcriptomes. Under repeated CD19 stimulation, CLL-derived products reached a proliferative ceiling, and p53-high products lost cytotoxic reserve. Ibrutinib improved proliferative fitness, attenuated senescence-associated features and SASP output in paired patient and direct-exposure assays, and enhanced CAR T-cell expansion in an ibrutinib-resistant CLL model. Together, these data identify immunosenescence as a measurable and functionally consequential barrier to CAR T-cell efficacy in CLL and a candidate for therapeutic modulation.
Editorial Commentary
Schultis, Kaitlyn, Koo, Kevin , Schultis, Kaitlyn E

Urology Practice | August 21, 2026 | Volume: 13 | Issue: 5 | Pages: 471-472

10.1097/upj.0000000000001028 | PMID 42627052 Get It