Citations

Mayo Clinic

Clear

399 citation(s) found for "Yu, Yi‐Hao".

Characteristics of rehabilitation protocols following operative treatment of terrible triad elbow injuries and the influence of early motion: A systematic review and meta-analysis
Larwa, Joseph , Buchanan, Timothy R. , Janke, Rachel L. , Burns, Madison Q. , Wright, Logan , Hao, Kévin A. , Cueto, Robert J. , Hones, Keegan M. , Aibinder, William R. , Wright, Thomas W. , Schoch, Bradley S , King, Joseph J , Hao, Kevin A , Aibinder, William R , Hones, Keegan M , Wright, Logan, Schoch, Bradley S. , King, Joseph J.

Shoulder & Elbow | August 6, 2024 | Volume: 17 | Issue: 6 | Pages: 831-843

10.1177/17585732241269807 | PMID 39552691 Get It

Background As no consensus exists on the optimal postoperative rehabilitation protocol in terrible triad injuries, we sought to characterize the reported protocols and relate them to postoperative range of motion (ROM) measures and Mayo Elbow Performance Score (MEPS). Methods A systematic review was performed by searching PubMed/MEDLINE, Embase, Web of Science, and Cochrane databases to identify articles on the operative treatment of terrible triad injuries reporting postoperative rehabilitation protocols were included. Included studies were descriptively summarized. Methodologic quality was assessed using the Methodological Index for Non-randomized Studies criteria. Meta-analysis compared postoperative ROM measures and the MEPS between patients initiating passive ROM exercises at ≤7 days vs. >7 days. Results Our review included 36 articles with 1123 elbows (66% male, mean age: 43 years, follow-up: 27 months). Of the studies reporting physical therapy protocols, it was most commonly initiated at 7 days postoperatively (6/36, 17%), passive ROM exercises at 7 days (3/25, 12%), and active ROM at 21 days (4/26, 15%). On meta-analysis, early passive ROM initiation was not associated with improved elbow ROM or MEPS. Discussion While rehabilitation protocols commonly advised passive ROM at one week post-operatively, meta-analysis did not support functional benefits of early passive ROM. Study design Systematic Review; Level of evidence, 4.
Establishing Consensus for Mohs Micrographic Surgical Techniques in the Treatment of Melanoma in Situ for Future Clinical Trials: A Modified Delphi Study
Curtis, K., Fakult, Nathan J., Strunck, Jennifer L. , Aasi, Sumaira Z. , Ahn, Christine , Alam, Murad, Bar, Anna, Behshad, Ramona, Bichakjian, Christopher K. , Bolotin, Diana, Boone, Susan L., Brewer, Jerry D., Carr, David R. , Castillo, Jason R., Christensen, Sean R. , Clark, Melanie A., Collins, Lindsey K., Demer, Addison M. , Eisen, Daniel B. , Feng, Hao , Firoz, Bahar, Grekin, Roy C. , Hirshburg, Jason M., Holmes, Todd, Huang, Conway C. , Jennings, Thomas , Konda, Sailesh , Leitenberger, Justin J. , Lewin, Jesse M., Ng, Elise, Orengo, Ida, Samie, Faramarz H. , Saylor, Drew K. , Soleymani, Teo, Tate, Jesalyn A. , Vidal, Nahid Y. , Vij, Alok , Wysong, Ashley , Xu, Yaohui G. , Carroll, Bryan T. , Curtis, Kristen K., Bordeaux, Jeremy S. , Carr, David R., Carucci, John A. , Jiang, Shang I. Brian , Maher, Ian A. , Sharon, Victoria R. , Swetter, Susan M. , Beek, Marta J. Van , Yu, Wesley Y.

Journal of the National Comprehensive Cancer Network | July 30, 2024 | Volume: 22 | Issue: 8 | Pages: No page available

10.6004/jnccn.2024.7036 | PMID 39079545 Get It

Background: Mohs micrographic surgery (MMS) is a promising treatment modality for melanoma in situ (MIS). However, variations in surgical technique limit the generalizability of existing data and may impede future study of MMS in clinical trials. Methods: A modified Delphi method was selected to establish consensus on optimal MMS techniques for treating MIS in future clinical trials. The Delphi method was selected due to the limited current data, the wide range of techniques used in the field, and the intention to establish a standardized technique for future clinical trials. A literature review and interviews with experienced MMS surgeons were performed to identify dimensions of the MMS technique for MIS that (1) likely impacted costs or outcomes of the procedure, and (2) showed significant variability between surgeons. A total of 8 dimensions of technical variation were selected. The Delphi process consisted of 2 rounds of voting and commentary, during which 44 expert Mohs surgeons across the United States rated their agreement with specific recommendations using a Likert scale. Results: Five of eight recommendations achieved consensus in Round 1. All 3 of the remaining recommendations achieved consensus in Round 2. Techniques achieving consensus in Round 1 included the use of a starting peripheral margin of ≤5 mm, application of immunohistochemistry, frozen tissue processing, and resecting to the depth of subcutaneous fat. Consensus on the use of Wood’s lamp, dermatoscope, and negative tissue controls was established in Round 2. Conclusions: This study generated 8 consensus recommendations intended to offer guidance for Mohs surgeons treating MIS. The adoption of these recommendations will promote standardization to facilitate comparisons of aggregate data in multicenter clinical trials.
AAPM Task Group Report 299: Quality control in multi‐energy computed tomography
Leng, Shuai, Boedeker, Kirsten , Burk, Laurel M., Dang, Hao , Li, Baojun , Madhav, Priti, Miller, Jessica R. , Nute, J, Giraldo, Juan Carlos Ramírez, Ruchala, Kenneth J., Tao, Shengzhen , Varchena, Vladimir, Vedantham, Srinivasan , Zeng, Rongping , Layman, Rick R. , Leng, Shuai , Duan, Xinhui , Jacobsen, Megan C. , Li, Ke , Little, Kevin J. , Ruchala, Ken, Zhang, Da

Medical Physics | July 29, 2024 | Volume: 51 | Issue: 10 | Pages: 7012-7037

10.1002/mp.17322 | PMID 39072826 Get It

AbstractMulti‐energy computed tomography (MECT) offers the opportunity for advanced visualization, detection, and quantification of select elements (e.g., iodine) or materials (e.g., fat) beyond the capability of standard single‐energy computed tomography (CT). However, the use of MECT requires careful consideration as substantially different hardware and software approaches have been used by manufacturers, including different sets of user‐selected or hidden parameters that affect the performance and radiation dose of MECT. Another important consideration when designing MECT protocols is appreciation of the specific tasks being performed; for instance, differentiating between two different materials or quantifying a specific element. For a given task, it is imperative to consider both the radiation dose and task‐specific image quality requirements. Development of a quality control (QC) program is essential to ensure the accuracy and reproducibility of these MECT applications. Although standard QC procedures have been well established for conventional single‐energy CT, the substantial differences between single‐energy CT and MECT in terms of system implementations, imaging protocols, and clinical tasks warrant QC tests specific to MECT. This task group was therefore charged with developing a systematic QC program designed to meet the needs of MECT applications. In this report, we review the various MECT approaches that are commercially available, including information about hardware implementation, MECT image types, image reconstruction, and postprocessing techniques that are unique to MECT. We address the requirements for MECT phantoms, review representative commercial MECT phantoms, and offer guidance regarding homemade MECT phantoms. We discuss the development of MECT protocols, which must be designed carefully with proper consideration of MECT technology, imaging task, and radiation dose. We then outline specific recommended QC tests in terms of general image quality, radiation dose, differentiation and quantification tasks, and diagnostic and therapeutic applications.
Follicular helper- and peripheral helper-like T cells drive autoimmune disease in human immune system mice
Vecchione, Andrea, Danzl, Nichole , Li, Hao Wei , Nauman, Grace , Madley, Rachel, Winchester, Robert , Ruiz, Amanda , Ding, Xiaolan, Sykes, Megan , Khosravi-Maharlooei, Mohsen , Waffarn, Elizabeth , Fousteri, Georgia

No container title available | July 29, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.7554/elife.99389.1 Get It

Abstract Human immune system (HIS) mice constructed in various ways are widely used for investigations of human immune responses to pathogens, transplants and immunotherapies. In HIS mice that generate T cells de novo from hematopoietic progenitors, T cell-dependent multisystem autoimmune disease occurs, most rapidly when the human T cells develop in the native NOD.Cg- Prkdcscid Il2rgtm1Wjl (NSG) mouse thymus, where negative selection is abnormal. Disease develops very late when human T cells develop in human fetal thymus grafts, where robust negative selection is observed. We demonstrate here that PD-1+CD4+ peripheral (Tph) helper-like and follicular (Tfh) helper-like T cells developing in HIS mice can induce autoimmune disease. Tfh-like cells were more prominent in HIS mice with a mouse thymus, in which the highest levels of IgG were detected in plasma, compared to those with a human thymus. While circulating IgG and IgM antibodies were autoreactive to multiple mouse antigens, in vivo depletion of B cells and antibodies did not delay the development of autoimmune disease. Conversely, adoptive transfer of enriched Tfh- or Tph-like cells induced disease and autoimmunity-associated B cell phenotypes in recipient mice containing autologous human APCs without T cells. T cells from mice with a human thymus expanded and induced disease more rapidly than those originating in a murine thymus, implicating HLA-restricted T cell-APC interactions in this process. Since Tfh, Tph, autoantibodies and LIP have all been implicated in various forms of human autoimmune disease, the observations here provide a platform for the further dissection of human autoimmune disease mechanisms and therapies.
Follicular helper- and peripheral helper-like T cells drive autoimmune disease in human immune system mice
Khosravi-Maharlooei, Mohsen , Vecchione, Andrea, Danzl, Nichole , Li, Hao Wei , Nauman, Grace , Madley, Rachel, Winchester, Robert , Ruiz, Amanda , Ding, Xiaolan, Sykes, Megan , Winchester, Robert , Ruiz, Amanda , Ding, Xiaolan , Sykes, Megan , Khosravi-Maharlooei, Mohsen , Waffarn, Elizabeth , Fousteri, Georgia

eLife | July 29, 2024 | Volume: 13 | Issue: No issue available | Pages: No page available

10.7554/elife.99389 | PMID 40293219 Get It

Human immune system (HIS) mice constructed in various ways are widely used for investigations of human immune responses to pathogens, transplants, and immunotherapies. In HIS mice that generate T cells de novo from hematopoietic progenitors, T cell-dependent multisystem autoimmune disease occurs, most rapidly when the human T cells develop in the native NOD.Cg- Prkdc scid Il2rg tm1Wjl (NSG) mouse thymus, where negative selection is abnormal. Disease develops very late when human T cells develop in human fetal thymus grafts, where robust negative selection is observed. We demonstrate here that PD-1 + CD4 + peripheral (Tph) helper-like and follicular (Tfh) helper-like T cells developing in HIS mice can induce autoimmune disease. Tfh-like cells were more prominent in HIS mice with a mouse thymus, in which the highest levels of IgG were detected in plasma, compared to those with a human thymus. While circulating IgG and IgM antibodies were autoreactive to multiple mouse antigens, in vivo depletion of B cells and antibodies did not delay the development of autoimmune disease. Conversely, adoptive transfer of enriched Tfh- or Tph-like cells induced disease and autoimmunity-associated B cell phenotypes in recipient mice containing autologous human APCs without T cells. Tfh/Tph cells from mice with a human thymus expanded and induced disease more rapidly than those originating in a murine thymus, implicating HLA-restricted T cell-APC interactions in this process. Since Tfh, Tph, autoantibodies, and lymphopenia-induced proliferation (LIP) have all been implicated in various forms of human autoimmune disease, the observations here provide a platform for the further dissection of human autoimmune disease mechanisms and therapies.
Defining the tipping point for revision reverse shoulder arthroplasty
Buchanan, Timothy R. , Hao, Kévin A. , Cueto, Robert J. , O’Keefe, Daniel S. , Hones, Keegan M. , Krisanda, Emily, Wright, Jonathan O. , Wright, Thomas W. , Struk, Aimee M., S O'Keefe, Daniel , Wright, Jonathan O , Schoch, Bradley S , King, Joseph J , Hao, Kevin A , Hones, Keegan M , Bindi, Victoria E. , Farmer, Kevin W. , Schoch, Bradley S. , King, Joseph J.

Shoulder & Elbow | July 23, 2024 | Volume: 17 | Issue: 4 | Pages: 439-449

10.1177/17585732241263753 | PMID 39552664 Get It

Background This study sought to characterize the tipping point values (the functional scores that patients deem dysfunctional enough to warrant surgery) for patients undergoing first revision reverse total shoulder arthroplasty (rTSA). Methods This study was a retrospective review of a prospectively collected single-institution database of patients undergoing first revision rTSA between August 2015 and December 2019. Tipping point evaluation utilized preoperative scores including the American Shoulder and Elbow Surgeons (ASES), raw and normalized Constant, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), and University of California-Los Angeles (UCLA) scores, and active range of motion including abduction, forward elevation (FE), external rotation (ER), and internal rotation score (IR) prior to elective revision rTSA. Results We included 125 revision rTSAs. Tipping points were 37.6 ASES score, 30.5 raw Constant score, 35.5 normalized Constant score, 68.1 SPADI, 3.7 SST, 13.2 UCLA score, 64° abduction, 69° FE, 23° ER, and 3.1 IR. Higher SST was found for older patients and patients with a lower body mass index. Lower abduction and FE tipping points were reported in patients undergoing revision rTSA for rotator cuff failure, unexplained pain, and implant wear. Discussion These tipping points can help surgeons counsel patients regarding when to undergo revision rTSA. Level of evidence Level III; retrospective cohort study; treatment study.
Baduanjin for ischemic heart failure with mildly reduced/preserved ejection fraction (BEAR Trial): A randomized controlled trial
Li, Jingen , Yu, Meili, Wang, Yanhui , Li, Siming , Li, Siwei , Feng, Xue , Li, R.K. , Chen, Keji , Xu, Hao , Li, Jingen , Li, Ruijie

Journal of Evidence-Based Medicine | July 6, 2024 | Volume: 17 | Issue: 3 | Pages: 526-534

10.1111/jebm.12631 | PMID 38970325 Get It

AbstractAimWhile Baduanjin, a traditional Chinese mind‐body exercise, has shown potential health benefits, its efficacy in improving outcomes for heart failure patients with mildly reduced or preserved ejection fraction (HFmrEF/HFpEF) has not been well documented. We aimed to investigate the adjunctive impact of Baduanjin on exercise capacity and quality of life for HFmrEF/HFpEF.MethodsPatients with HFmrEF/HFpEF were enrolled in this multicenter randomized clinical trial. All participants were randomized to conventional cardiac rehabilitation with or without an additional 12‐week Baduanjin exercise. The primary endpoint was the distance covered in a 6‐min walk test (6MWD), while key secondary outcomes included quality of life measured by the Minnesota Living with Heart Failure Questionnaire (MLHFQ) and cardiopulmonary function including anaerobic threshold (VO2 AT).ResultsA total of 120 patients were enrolled, and 109 completed all session and tests. The mean age of the 120 patients was 60.5 years (SD, 9.21 years), and 23 (19.2%) were women. The Baduanjin group exhibited a 6.14% improvement in 6MWD compared to a 1.32% improvement in the control group (median improvement, 25.0 vs. 5.0 m; p < 0.001) at 12th week. The VO2 AT increased by 25.87% in the Baduanjin group versus 3.94% in the control group (p < 0.001). Quality of life also significantly improved in the Baduanjin group as indicated by MLHFQ score changes (–16.8% vs. –3.99%; p < 0.001).ConclusionsAdding Baduanjin to exercise‐based cardiac rehabilitation for patients with ischemic HFmrEF or HFpEF are generally safe and could provide significant improvements in exercise capacity and quality of life.
Acquisition Efficiency and Technical Repeatability of Dual‐Frequency 3D Vector MR Elastography of the Liver
Qiu, Caixin , Glaser, Kevin J. , Owusu, Nana , Li, Jiahui , Yin, Meng , Wu, Hao , Qiu, Caixin , Yin, Meng , Li, Jiahui , Wu, Hao , Venkatesh, Sudhakar K. , Manduca, Armando , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | June 27, 2024 | Volume: 61 | Issue: 3 | Pages: 1416-1425

10.1002/jmri.29493 | PMID 38935749 Get It

BackgroundMR elastography (MRE) at 60 Hz is widely used for staging liver fibrosis. MRE with lower frequencies may provide inflammation biomarkers.PurposeTo establish a practical simultaneous dual‐frequency liver MRE protocol at both 30 Hz and 60 Hz during a single examination and validate the occurrence of second harmonic waves at 30 Hz.Study TypeRetrospective.SubjectsOne hundred six patients (48 females, age: 50.0 ± 13.4 years) were divided as follows: Cohort One (15 patients with chronic liver disease [CLD] and 25 healthy volunteers) with simultaneous dual‐frequency MRE. Cohort Two (66 patients with CLD) with second harmonic MRE.Field Strength/Sequence3‐T, single‐ or dual‐frequency MRE at 30 Hz and 60 Hz.AssessmentLiver stiffness (LS) in both cohorts was evaluated with manually placed volumetric ROIs by two independent analyzers. Image quality was assessed by three independent readers on a 4‐point scale (0–3: none/failed, fair, moderate, excellent) based on the depth of wave propagation with 1/3 incremental penetration. The success rate was derived from the percentage of nonzero quality scores.Statistical TestsMeasurement agreement, bias, and repeatability of LS were assessed using intraclass correlation coefficients (ICCs), Bland–Altman plots, and repeatability coefficient (RC). Mann–Whitney U tests were used to evaluate the differences in image quality between different methods. A P‐value <0.05 was considered statistically significant.ResultsSuccess rate was 97.5% in Cohort One and 91% success rate for the second harmonic MRE in Cohort Two. The second harmonic and conventional MRE showed excellent agreement in LS (all ICCs >0.90). The quality scores for the second harmonic wave images were lower than those from the conventional MRE (Z = −4.523).Data ConclusionCompared with conventional and second harmonic methods, simultaneous dual‐frequency had better image quality, high success rate and the advantage of intrinsic co‐registration, while the second harmonic method can be an alternative if custom waveform is not available.Evidence Level3Technical EfficacyStage 1
Challenging the Concept of Statistical Fragility: Is There Any Value Added?
Hao, Kévin A. , Schoch, Bradley S , Hao, Kevin A , Vasilopoulos, Terrie , Wright, Jonathan O. , Schoch, Bradley S.

Journal of Bone and Joint Surgery | June 20, 2024 | Volume: 106 | Issue: 22 | Pages: 2172-2174

10.2106/jbjs.24.00368 | PMID 38900863 Get It

Abstract: Today, well-designed randomized clinical trials (RCTs) are considered the pinnacle of clinical research, and they inform many practices in orthopaedics. When designing these studies, researchers conduct a power analysis, which allows researchers to strike a balance between (1) enrolling enough patients to detect a clinically important treatment effect (i.e., researchers can be confident that the effect is unlikely due to chance) and (2) cost, time, and risk to patients, which come with enrolling an excessive number of patients. Because researchers will have a desire to conduct resource-efficient RCTs and protect patients from harm, many studies report a p value that is close to the threshold for significance. The concept of the fragility index (FI) was introduced as a simple way to interpret RCT findings, but it does not account for RCT design. The adoption of the FI conflicts with researchers’ goals of designing efficient RCTs that conserve resources and limit ineffective or harmful treatments to patients. The use of the FI may reflect many clinicians’ lack of familiarity with interpreting p values beyond “significant” or “nonsignificant.” Instead of inventing new metrics to convey the same information provided by the p value, greater emphasis should be placed on educating clinicians on how to interpret p values and, more broadly, statistics, when reading scientific studies.
In‐hospital outcomes among amyloidosis patients with atrial fibrillation: A propensity score‐matched analysis
Yeo, Yong Hao , San, Boon‐Jian, Ang, Qi‐Xuan, Tan, Jian Liang , Tan, Min Choon , Yeo, Yong Hao

Journal of Arrhythmia | June 18, 2024 | Volume: 40 | Issue: 4 | Pages: 1001-1004

10.1002/joa3.13100 | PMID 39139881 Get It

AbstractBackgroundThe impact of atrial fibrillation (AF) among patients with amyloidosis on in‐hospital outcomes is not well‐established. We aimed to examine in‐hospital outcomes among patients admitted with a primary diagnosis of AF with and without amyloidosis.Methods and ResultsWe queried the Nationwide Readmissions Database to compare the in‐hospital outcomes among AF patients with and without amyloidosis. Our study demonstrated that in‐hospital all‐cause mortality, adverse events, and 30‐day readmission were comparable between the two groups.ConclusionsPatients with AF and concurrent amyloidosis did not have worse in‐hospital outcomes than those with AF alone.