Citations

Mayo Clinic

Showing 10 of 108304 citations.

Comparison between Immunoturbidimetry, Size-Exclusion Chromatography, and LC-MS to Quantify Urinary Albumin
Shaikh, Aisha , Seegmiller, Jesse C. , Borland, Timothy M., Burns, Bradley E., Ladwig, Paula M. , Kumar, Rajiv , Larson, Timothy S., Singh, Ravinder J. , Lieske, John C. , Kumar, Rajiv

Clinical Chemistry | July 11, 2008 | Volume: 54 | Issue: 9 | Pages: 1504-1510

10.1373/clinchem.2008.107508 | PMID 18617580 Get It

Abstract Background: The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-exclusion HPLC. Methods: We obtained unused clinical urine samples from 150 patients who were stratified by degrees of albuminuria (<20 mg/L, 20–250 mg/L, >250 mg/L) as determined by the immunoturbidimetric assay used in our clinical laboratory (Roche Hitachi 912). Urine albumin was then remeasured via LC-MS and HPLC (Accumin™) assays. Results: The immunoturbidimetric assay, calibrated using manufacturer-supplied serum-derived calibrators (Diasorin), underestimated albumin compared with LC-MS. After calibration with purified HSA, this immunoturbidimetric assay correlated well with LC-MS. HPLC overestimated albumin compared with both LC-MS and immunoturbidimetry. The current LC-MS and HPLC assays both performed poorly at concentrations <20 mg/L. Conclusions: Efforts are needed to establish gold-standard traceable calibrators for clinical assays. LC-MS is a specific method to quantify albumin in native urine when concentrations exceed 20 mg/L, and therefore could be employed for standardization among assays.
Charged Modification of Hydrogel for Nerve Regeneration
Dadsetan, Mahrokh, Vallejo‐Giraldo, Catalina , Lu, Lichun , Windebank, Anthony J. , Yaszemski, Michael J. , Knight, Andrew Michael

Journal of Medical Devices | July 10, 2008 | Volume: 2 | Issue: 2 | Pages: No page available

10.1115/1.2934347 Get It

Natural and synthetic hydrogels have attracted much attention for nerve regeneration. Previous studies have shown that electrical charge has significant effect on stimulation of neurite outgrowth. In this work, incorporation of a positively charged monomer into the photocrosslinkable oligo(polyethylene glycol) fumarate (OPF) hydrogel has been investigated. We have evaluated the effect of localized positive charge on neurite outgrowth in culture with an objective that positively charged hydrogels ultimately can be used for stimulating in vivo nerve regeneration. The effect of charged modification has been also studied on mechanical properties and swelling ratio of these hydrogels. Our data indicated that with increasing charge density hydrogels swelling ratio increased in water, however it remained constant in PBS. We also demonstrated that compressive modulus and tensile strength of the hydrogels improved with incorporation of electrical charge into the hydrogels. Biodegradation of modified hydrogels was investigated in a series of biomimetic solutions. OPF hydrogels appeared to be more susceptible to oxidative degradation as opposed to the hydrolytic degradation in enzymes and acidic solution, and the degradation rate was correlated to the PEG molecular weight and charge density of the hydrogels. To investigate the effect of charge modification on nerve cell attachment and differentiation, dissociated dorsal root ganglion (DRG) cells were plated onto the modified and unmodified hydrogels surfaces. DRG cells attached and extended their neurites more readily on the surface of positively charged hydrogels as opposed to the unmodified hydrogels.
PMMA Implants Increase Femoral Strength
Dragomir‐Daescu, Dan , Bolander, Mark E., Bennet, Kevin E. , Bronk, James T., McEligot, Sean

Journal of Medical Devices | July 10, 2008 | Volume: 2 | Issue: 2 | Pages: No page available

10.1115/1.2934345 Get It

The number of osteoporotic hip fractures is projected to increase two to three fold in the next 30years. This will lead to increased mortality and nursing home placement with significant costs to our society. Although in clinical trials drug and hormone therapies have shown an important decrease in fracture risk there is a significant role of surgical implantation treatments to further reduce the risk in specific subpopulations. Strength testing was completed on four pairs of osteoporotic, two pairs of osteopenic, and two pairs of normal cadaver femurs. The fracturing was recorded with a video camera at 4000 frames per second. The specially designed test fixture was instrumented with three load cells to measure the femoral forces. Force and moment data were recorded simultaneously and correlated with the frames. The fracture force at the greater trochanter was used to characterize the strength of implanted∕nonimplanted osteoporotic femurs. All femurs began fracturing within about 60ms at a test speed of 100mm∕s. During the first 20ms, the relationship between force and displacement was nonlinear, but linear thereafter until the fracture occurs. The fracture events resolved completely within 10–20ms. The average strength increase of the implanted femurs was 79% compared to the nonimplanted controls. The simultaneous acquisition of fracture images and load data is a powerful tool to understand and characterize numerically the femoral fracture. This methodology allows the researcher to define the best metrics to compare competing reinforcement materials, implant designs and surgical procedures.
Custom TMJ Hemi-joint Fabrication Process
Kuhlmann, Joel, McEligot, Sean

Journal of Medical Devices | July 10, 2008 | Volume: 2 | Issue: 2 | Pages: No page available

10.1115/1.2932596 Get It

Temporomandibular joint disorder afflicts 10 million Americans, many of whom have osteoarthritis of the temporomandibular joint (TMJ). This condition can inflict severe pain and disrupt the lives of sufferers in many ways. Partial or total replacement of the temporomandibular joint is a last resort treatment option. Surgeons at Mayo Clinic believe a new hemijoint implant design coupled with unique surgical technique can improve joint kinematics and reduce pain. They are currently investigating a patent-pending implant design in a series of patient trials. The Division of Engineering at Mayo Clinic has developed a novel process for fabricating TMJ implants for this study. Computed Tomagraphy (CT) images of the surgical site are first converted into a 3D computer model of the mandibular fossa and condyle area. A fused deposition modeling process is used to create a plastic model of the anatomy, and the surgeons use that model to create a wax mold of the implant. The wax mold is laser scanned to create a 3D CAD model that can be machined with a standard four axis milling machine out of implant grade CoCrMo material. Because of the unique shape of the implant, the machining takes place in two phases, with the implant being refixtured between machining phases using a high strength industrial adhesive. Finally, the implant is polished, inspected, passivated and sterilized for surgery. This fabrication process has allowed Mayo Clinic surgeons to quickly and accurately test their unique implant design.
Integrating Physicians, Researchers and Engineers—60Years of Medical Device Innovation at Mayo Clinic
Horne, April E., Bennet, Kevin A., Buntrock, Nathan C., Halovsen, Thomas G., Wehde, Mark

Journal of Medical Devices | July 10, 2008 | Volume: 2 | Issue: 2 | Pages: No page available

10.1115/1.2924269 Get It

Medical innovation is often delayed by the difficulty in developing cooperation among practicing physicians, academics and medical device developers. In Rochester, Minnesota, the Mayo Clinic Division of Engineering has excelled at integrating these specialties, facilitating medical device innovation for the past 60years. In 1948, Mayo Clinic combined an instrument shop with an engineering design services team and created the Division of Engineering. This enabled a unique partnership between physicians, researchers, and product developers. Early innovations from this team include the Mayo heart-lung machine, cardiac monitoring, advances in aero-medicine, surgical stereotaxy, and early transfusion equipment. Today, the Mayo Division of Engineering consists of mechanical, chemical, electrical, biomedical, and software engineers, machinists, and a scientific glass-blower. The division works in close collaboration with project proponents (primarily physicians) within the clinical environment to analyze problems, propose designs, and deliver a clinical solution. From custom 3-D models for support pre-surgical planning to endoscopic heart valve repair devices, the team identifies opportunities and delivers systems that can be quickly translated into medical practice.
Nomenclature of Robotic Procedures in Urology
Castle, Erik P., Lee, David I. , Thomas, Raju , Ahlering, Thomas E.

Journal of Endourology | July 9, 2008 | Volume: 22 | Issue: 7 | Pages: 1467-1470

10.1089/end.2008.0197 | PMID 18613788 Get It

Impact of Obesity on Clinicopathologic Outcomes after Robot-Assisted Laparoscopic Prostatectomy
Boorjian, Stephen A. , Crispen, Paul L. , Carlson, Rachel E. , Rangel, Laureano J. , Karnes, R. Jeffrey , Frank, Igor, Gettman, Matthew T.

Journal of Endourology | July 9, 2008 | Volume: 22 | Issue: 7 | Pages: 1471-1476

10.1089/end.2008.0056 | PMID 18613784 Get It

Opioid-Induced Pain
Prommer, Eric

Journal of Clinical Oncology | July 9, 2008 | Volume: 26 | Issue: 20 | Pages: 3464-3465

10.1200/jco.2008.17.3633 | PMID 18612166 Get It

Estrogen Supplementation Selectively Enhances Hypothalamo-Pituitary Sensitivity to Ghrelin in Postmenopausal Women
Kok, Petra, Paulo, Remberto, Cosma, Mihaela, Mielke, Kristi L., Miles, John M., Bowers, Cyril Y., Veldhuis, Johannes D. , Miles, John M.

The Journal of Clinical Endocrinology & Metabolism | July 9, 2008 | Volume: 93 | Issue: 10 | Pages: 4020-4026

10.1210/jc.2008-0522 | PMID 18611978 Get It

Context: Sex-steroid hormones amplify pulsatile GH secretion by unknown mechanisms. Ghrelin is the most potent natural GH secretagogue discovered to date. A plausible unifying postulate is that estradiol (E2) enhances hypothalamo-pituitary sensitivity to ghrelin (a physiological effect). The hypothesis is relevant to understanding the basis of hyposomatotropism in aging and other relatively hypogonadal states. Objective: Our objective was to test the hypothesis that E2 supplementation potentiates ghrelin’s stimulation of pulsatile GH secretion. Setting: The study was conducted at an academic medical center. Subjects: Healthy postmenopausal women (n = 20) were included in the study. Interventions: Separate-day iv infusions of saline vs. five graded doses of ghrelin were performed in volunteers prospectively randomly assigned to receive (n = 8) or not receive (n = 12) transdermal E2 for 21 d were performed. Measures: GH secretion was estimated by deconvolution analysis and abdominal visceral fat mass determined by computerized axial tomography were calculated. Results: E2 supplementation augmented ghrelin’s stimulation of basal (nonpulsatile) GH secretion by 3.6-fold (P = 0.022), increased GH responses to low-dose ghrelin by 2.9-fold (P = 0.035), did not alter ghrelin efficacy, and elicited more regular patterns of acylated ghrelin concentrations during saline infusion (P = 0.033). Abdominal visceral fat negatively determined responses to ghrelin (R = −0.346; P < 0.005). Conclusions: Transdermal E2 supplementation potentiates GH secretion stimulated by physiological but not pharmacological concentrations of acylated ghrelin, and concomitantly regularizes patterns of bioactive ghrelin secretion in postmenopausal women. Accordingly, the estrogen milieu appears to control sensitivity of the hypothalamopituitary unit to acylated ghrelin.
Molecular basis for the thiol sensitivity of insulin-degrading enzyme
Neant-Fery, Marie, Garcia-Ordoñez, Rubén D., Logan, Todd P., Li, Lilin , Reinstatler, Lael , Leissring, Malcolm A. , Selkoe, Dennis J.

Proceedings of the National Academy of Sciences | July 9, 2008 | Volume: 105 | Issue: 28 | Pages: 9582-9587

10.1073/pnas.0801261105 | PMID 18621727 Get It

Insulin-degrading enzyme (IDE) is a ubiquitous zinc-metalloprotease that hydrolyzes several pathophysiologically relevant peptides, including insulin and the amyloid β-protein (Aβ). IDE is inhibited irreversibly by compounds that covalently modify cysteine residues, a mechanism that could be operative in the etiology of type 2 diabetes mellitus (DM2) or Alzheimer's disease (AD). However, despite prior investigation, the molecular basis underlying the sensitivity of IDE to thiol-alkylating agents has not been elucidated. To address this topic, we conducted a comprehensive mutational analysis of the 13 cysteine residues within IDE. Our analysis implicates C178, C812, and C819 as the principal residues conferring thiol sensitivity. The involvement of C812 and C819, residues quite distant from the catalytic zinc atom, provides functional evidence that the active site of IDE comprises two separate domains that are operational only in close apposition. Structural analysis and other evidence predict that alkylation of C812 and C819 disrupts substrate binding, whereas alkylation of C178 interferes with the apposition of active-site domains and subtly repositions zinc-binding residues. Unexpectedly, alkylation of C590 was found to activate hydrolysis of Aβ significantly, while having no effect on insulin, demonstrating that chemical modulation of IDE can be both bidirectional and highly substrate selective. Our findings resolve a long-standing riddle about the basic enzymology of IDE with important implications for the etiology of DM2 and AD. Moreover, this work uncovers key details about the mechanistic basis of the unusual substrate selectivity of IDE that may aid the development of pharmacological agents or IDE mutants with therapeutic value.