AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.
Editorial for “Short‐Term Repeatability of In Vivo Cardiac Intravoxel Incoherent Motion (IVIM) Tensor Imaging in Healthy Human Volunteers”
AbstractIntroductionThe right ventricle (RV) strain measured by speckle tracking (RVS) is an echocardiographic parameter used to assess RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular plane systolic excursion (TAPSE) and Doppler tissue imaging‐derived peak systolic velocity (Sʹ) in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI).MethodsWe enrolled consecutive patients who underwent cardiac MRI between Jan 2012 and Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, Sʹ, and FAC% were tested for accuracy to identify impaired RV EF (EF < 45% & <30%) using receiver operator curves.ResultsThe study cohort included 500 patients with mean age 55 years ± 18 and peak tricuspid regurgitation velocity 2.7 ± 1.4 m/s. The area under ROC for RVS was 0.69 (95% CI 0.63–0.75) and 0.78 (95% CI 0.70–0.88) to predict RVEF < 45% & RVEF < 30%, respectively. The RV FAC% had second highest accuracy of predicting RVEF among all the TTE parameters tested in study.ConclusionRight ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.
A Unique Compensatory Mechanism for Total Pulmonary Vein Occlusion Post Atrial Fibrillation Catheter Ablation Visualized by Multimodality Imaging
Pulmonary vein (PV) stenosis is a rare and serious complication of radiofrequency catheter ablation (RFCA) for atrial fibrillation. However, it can be asymptomatic or mildly symptomatic depending on the severity of the stenosis and the development of compensatory mechanisms. This study provides a detailed description and visualization of a unique type of venous collaterals that bypass the PV stenosis and drain directly in the left atrium alleviating PV stenosis sequelae. This study reports a case of a 61-year-old male who presented with mild dyspnea and fatigue 3 years post atrial fibrillation RFCA. After a thorough evaluation of the case, a redo-ablation was planned. As a part of the preablation workup, a transesophageal echocardiography (TEE), a ventilation-perfusion (V/Q) scan of the lungs, and a chest computed tomography angiogram (CTA) were performed. The TEE revealed total obstruction of the left superior PV, with no color Doppler flow detected. It also showed evidence of multiple collateral flows at the os of the left superior PV. The V/Q scan showed a large perfusion defect involving the entire left upper lobe consistent with a compromised left upper PV flow. The CTA with 3D volume rendering revealed the total occlusion of the left superior PV at its ostium. Moreover, the scan confirmed the pulmonary venous drainage via small collateral channels that was suggested by the TEE.
Multimodality Imaging Demonstrating an Apical Variant Hypertrophic Cardiomyopathy in an Uncommon Pentad
A 79-year-old man was admitted for a transcatheter aortic valve replacement due to severe aortic stenosis. A preoperative chest computed tomography with angiography revealed an apical variant hypertrophic cardiomyopathy with a prominent apical pouch. In addition, there was near-complete obliteration of the left ventricle in the mid to apical aspect during systole suggesting a midventricular gradient. Postoperative transthoracic echocardiography confirmed the apical variant hypertrophic cardiomyopathy with an apical aneurysm and a gradient with a peak velocity of 2 m/s, and mid-cavitary gradient with a peak velocity of 3 m/s. It also revealed a fusiform aneurysmal dilatation of the ascending aorta.