Abstract Extracellular vesicles (EV) are phospholipid‐encapsulated nanoparticles secreted by cells into their surrounding environment. EVs can transfer a variety of biomolecules that mediate intercellular communication and play a key role in physiological and pathological processes. Therefore, EVs are emerging as new biomarkers for diseases, therapeutic targets, and drug delivery vehicles. The isolation and detection of EVs requires time‐consuming and labor‐intensive processes, first to extract EVs from biological and physiological fluids and then to detect EV‐associated molecules with high sensitivity. The methodologies and instruments commonly used for EV analysis are not widely accessible outside of dedicated research laboratories, creating practical barriers for the study of EV‐associated molecules in biology research and clinical applications. To bridge this gap, we developed a proof‐of‐concept digital microfluidic device that can automatedly extract EVs from 20 µL of culture and human plasma samples within 25 min and detect EV‐bound proteins (e.g PD‐L1) on‐chip using an electrochemical sensor. This work serves as a framework for the development of streamlined EV analysis in both research and diagnostics.
Abstract A030: Rapid extraction and detection of extracellular vesicle-derived PD-L1 in a microfluidic platform
Abstract Background. Extracellular vesicles (EV) are emerging as new biomarkers for cancer diagnostics and therapeutic monitoring1. For example, in patients that receive PD1/PD-L1 immune checkpoint inhibitors (a key pillar of cancer immunotherapy), circulating EV-derived PD-L1 is gaining attention as a non-invasive biomarker for therapeutic efficacy. Standard methodologies to measure EV-derived PD-L1 requires ultracentrifugation to first separate EVs and then quantify those that express PD-L1 using nano flow cytometry. These are tedious processes that require trained technologists in centralized facilities, which is a key barrier to frequently monitoring EV-based biomarkers. Yet, frequent monitoring is crucial to quickly identify and stop an ineffective therapy while more fruitful options are still available. Method. To bridge the gap, we develop a proof-of-concept digital microfluidic (DMF) device that can separate EVs directly from biofluids and quantify PD-L1+ EVs automatedly. Briefly, DMF device supports automatedly droplet handling, including droplet transport, splitting and mixing, based on electrowetting principles2. Immunomagnetic beads were used to capture EVs from biofluids, and EVs were then detected by electrochemical sensors inserted into the device. These tips of the electrochemical sensors were modified with gold nanoparticle self-assembled layers to enhance target binding, and CD9 antibodies were immobilized on the tips to bind to EVs. We then used anti-PD-L1 as secondary antibodies for target detection. Differential Pulse Voltammetry (DPV)3 were performed to obtain the results. Results. We used the DMF device to extract 109- 1011 #/mL EVs secreted by a human breast cancer cell line (MDA-MB-231). Briefly, 10 mL of cell culture media was loaded into the DMF device, and the sample was mixed and incubated with a 10 mL droplet of immunomagnetic beads to capture EVs. After 5 min, EVs were eluted in 20 mL of elution buffer, and the beads were discarded. We estimated the number of EVs using Nanoparticle Tracking Analysis; the number of EVs extracted on-chip was comparable with those that were extracted using standard in-tube method. We also verified the purity of the EVs extracted on-chip using Western Blot. Our results showed that the electrochemical sensors can detect as low as 104 #/mL PD-L1+ EVs, with a linear range of 104 – 107 #/mL (R2=0.9701). The entire process can be completed within 1 hour. Conclusion. We integrated automated EV extraction and their surface marker detection in a single DMF device. Our next step is to extract and detect EV-based biomarkers from plasma samples. This platform holds promise for the regular monitoring of EV-based biomarkers that are indicators of therapeutic responses in patients that receive cancer immunotherapies. References1. F. Lucien, D. Gustafson, M. Lenassi et al, Journal of extracellular vesicles 12 (12), 12385 (2023). 2. Y. Zhang and Y. Liu, Sensors & Diagnostics (2022). 3. Y. Zhang, J. Liu, T.-W. Lo et al, Biosensors and Bioelectronics: X, 100490 (2024). Citation Format: Ting-Wen Lo, Yuqian Zhang, Jing Liu, Yohan Kim, Haidong Dong, Fabrice Lucien, Yuguang Liu. Rapid extraction and detection of extracellular vesicle-derived PD-L1 in a microfluidic platform [abstract]. In: Proceedings of the AACR Special Conference: Liquid Biopsy: From Discovery to Clinical Implementation; 2024 Nov 13-16; San Diego, CA. Philadelphia (PA): AACR; Clin Cancer Res 2024;30(21_Suppl):Abstract nr A030.
28 Toward an automated microfluidic platform for monitoring immune response to immunotherapy
Colorectal cancer (CRC) is a prevalent and potentially fatal disease categorized based on its high incidences and mortality rates, which raised the need for effective diagnostic strategies for the early detection and management of CRC. While there are several conventional cancer diagnostics available, they have certain limitations that hinder their effectiveness. Significant research efforts are currently being dedicated to elucidating novel methodologies that aim at comprehending the intricate molecular mechanism that underlies CRC. Recently, microfluidic diagnostics have emerged as a pivotal solution, offering non-invasive approaches to real-time monitoring of disease progression and treatment response. Microfluidic devices enable the integration of multiple sample preparation steps into a single platform, which speeds up processing and improves sensitivity. Such advancements in diagnostic technologies hold immense promise for revolutionizing the field of CRC diagnosis and enabling efficient detection and monitoring strategies. This article elucidates several of the latest developments in microfluidic technology for CRC diagnostics. In addition to the advancements in microfluidic technology for CRC diagnostics, the integration of artificial intelligence (AI) holds great promise for further enhancing diagnostic capabilities. Advancements in microfluidic systems and AI-driven approaches can revolutionize colorectal cancer diagnostics, offering accurate, efficient, and personalized strategies to improve patient outcomes and transform cancer management.
Advances in integrated digital microfluidic platforms for point-of-care diagnosis: a review
This work highlights recent advancements in the integration of analytical tools into DMF devices, and discusses the current challenges and potential solutions as well as future outlooks for an automated, integrative platform for POC applications.
A Digital Microfluidic Device Integrated with Electrochemical Impedance Spectroscopy for Cell-Based Immunoassay
The dynamic immune response to various diseases and therapies has been considered a promising indicator of disease status and therapeutic effectiveness. For instance, the human peripheral blood mononuclear cell (PBMC), as a major player in the immune system, is an important index to indicate a patient’s immune function. Therefore, establishing a simple yet sensitive tool that can frequently assess the immune system during the course of disease and treatment is of great importance. This study introduced an integrated system that includes an electrochemical impedance spectroscope (EIS)-based biosensor in a digital microfluidic (DMF) device, to quantify the PBMC abundance with minimally trained hands. Moreover, we exploited the unique droplet manipulation feature of the DMF platform and conducted a dynamic cell capture assay, which enhanced the detection signal by 2.4-fold. This integrated system was able to detect as few as 104 PBMCs per mL, presenting suitable sensitivity to quantify PBMCs. This integrated system is easy-to-operate and sensitive, and therefore holds great potential as a powerful tool to profile immune-mediated therapeutic responses in a timely manner, which can be further evolved as a point-of-care diagnostic device to conduct near-patient tests from blood samples.
Amplification of Femtograms of Bacterial DNA Within
3 h Using a Digital Microfluidics Platform for MinION Sequencing
Abstract Whole genome sequencing is emerging as a promising tool for the untargeted detection of a broad range of microbial species for diagnosis and analysis. However, it is logistically challenging to perform the multistep process from sample preparation to DNA amplification to sequencing and analysis within a short turnaround time. To address this challenge, we developed a digital microfluidic device for rapid whole genome amplification of low-abundance bacterial DNA and compared results with conventional in-tube DNA amplification. In this work, we chose Corynebacterium glutamicum DNA as a bacterial target for method development and optimization, as it is not a common contaminant. Sequencing was performed in a hand-held Oxford Nanopore Technologies MinION sequencer. Our results show that using an in-tube amplification approach, at least 1 pg starting DNA is needed to reach the amount required for successful sequencing within 2 h. While using a digital microfluidic device, it is possible to amplify as low as 10 fg of C. glutamicum DNA (equivalent to the amount of DNA within a single bacterial cell) within 2 h and to identify the target bacterium within 30 min of MinION sequencing100× lower than the detection limit of an in-tube amplification approach. We demonstrate the detection of C. glutamicum DNA in a mock community DNA sample and characterize the limit of bacterial detection in the presence of human cells. This approach can be used to identify microbes with minute amounts of genetic material in samples depleted of human cells within 3 h.
Whole genome amplification of single epithelial cells dissociated from snap-frozen tissue samples in microfluidic platform
Single cell sequencing is a technology capable of analyzing the genome of a single cell within a population. This technology is mostly integrated with microfluidics for precise cell manipulation and fluid handling. So far, most of the microfluidic-based single cell genomic studies have been focused on lab-cultured species or cell lines that are relatively easy to handle following standard microfluidic-based protocols without additional adjustments. The major challenges for performing single cell sequencing on clinical samples is the complex nature of the samples which requires additional sample processing steps to obtain intact single cells of interest without using amplification-inhibitive agents. Fluorescent-activated cell sorting is a common option to obtain single cells from clinical samples for single cell applications but requires >100 000 viable cells in suspension and the need for specialized laboratory and personnel. In this work, we present a protocol that can be used to obtain intact epithelial cells from snap-frozen postsurgical human endometrial tissues for single cell whole genome amplification. Our protocol includes sample thawing, cell dissociation, and labeling for genome amplification of targeted cells. Between 80% and 100% of single cell replicates lead to >25 ng of DNA after amplification with no measurable contamination, sufficient for downstream sequencing.
Heterogeneous Immunoassay Using Channels and Droplets in a Digital Microfluidic Platform
This work presents a heterogeneous immunoassay using the integrated functionalities of a channel and droplets in a digital microfluidic (DMF) platform. Droplet functionality in DMF allows for the programmable manipulation of discrete sample and reagent droplets in the range of nanoliters. Pressure-driven channels become advantageous over droplets when sample must be washed, as the supernatant can be thoroughly removed in a convenient and rapid manner while the sample is immobilized. Herein, we demonstrate a magnetic bead-based, enzyme-linked immunosorbent assay (ELISA) using ~60 nL of human interleukin-6 (IL-6) sample. The wash buffer was introduced in the form of a wall-less virtual electrowetting channel by a syringe pump at the flow rate of 10 μL/min with ~100% bead retention rate. Critical parameters such as sample wash flow rate and bead retention rate were optimized for reliable assay results. A colorimetric readout was analyzed in the International Commission on Illumination (CIE) color space without the need for costly equipment. The concepts presented in this work are potentially applicable in rapid neonatal disease screening using a finger prick blood sample in a DMF platform.
The Development of an Effective Bacterial Single-Cell Lysis Method Suitable for Whole Genome Amplification in Microfluidic Platforms
Single-cell sequencing is a powerful technology that provides the capability of analyzing a single cell within a population. This technology is mostly coupled with microfluidic systems for controlled cell manipulation and precise fluid handling to shed light on the genomes of a wide range of cells. So far, single-cell sequencing has been focused mostly on human cells due to the ease of lysing the cells for genome amplification. The major challenges that bacterial species pose to genome amplification from single cells include the rigid bacterial cell walls and the need for an effective lysis protocol compatible with microfluidic platforms. In this work, we present a lysis protocol that can be used to extract genomic DNA from both gram-positive and gram-negative species without interfering with the amplification chemistry. Corynebacterium glutamicum was chosen as a typical gram-positive model and Nostoc sp. as a gram-negative model due to major challenges reported in previous studies. Our protocol is based on thermal and chemical lysis. We consider 80% of single-cell replicates that lead to >5 ng DNA after amplification as successful attempts. The protocol was directly applied to Gloeocapsa sp. and the single cells of the eukaryotic Sphaerocystis sp. and achieved a 100% success rate.