AbstractBackground and AimThe aim of this study was to assess the effectiveness of yttrium‐90 (90Y) microspheres for the treatment of unresectable metastatic liver neuroendocrine tumors (NET).MethodsFrom February 2006 to September 2015, 36 patients (19 male and 17 female, age 63.6 ± 9.4 years) who underwent 90Y therapy for unresectable liver metastases of NET were included and analyzed retrospectively. All patients received a variety of treatments before 90Y therapy. The radiological response, symptoms improvement of carcinoid syndrome, tumor marker changes, complications, side effects/toxicity, survival, and factors related to survival were evaluated and analyzed.ResultsOf the 36 patients, the mean delivered dose of 90Y was 1.8 ± 0.7 GBq with a total of 40 treatments. Overall disease control rate was 88.9% (32/36) at 3 months following therapy. In 16 patients with carcinoid syndrome, 15 (93.8%) patients had symptomatic improvement. Tumor marker response (5‐hydroxyindoleacetic acid [n = 7] and chromogranin A [n = 13]) at 3 months after treatment were as follows: none (n = 0, 4), partial (n = 6, 7), and complete (n = 1, 2). Radiation‐induced gastrointestinal ulcers (n = 2, 5.6%) were identified. Side effects included fatigue (n = 31, 86.1%), anorexia (n = 26, 72.2%), nausea (n = 15, 41.7%), vomiting (n = 14, 38.9%), abdominal pain (n = 10, 27.8%), and fever (n = 8, 22.2%). The mean follow‐up was 27.0 ± 16.4 months, with a median survival of 41.0 months. Child–Pugh classification (P = 0.008) and lymph node metastases (P = 0.045) had statistically significant influence on overall survival.ConclusionsYttrium‐90 radioembolization can be effective in the treatment of unresectable liver metastases of NET who failed to respond to other treatments.
Hepatorenal Syndrome: A Review of Pathophysiology and Current Treatment Options
Background— Limited penetration into the caval wall is an important securing mechanism for inferior vena cava (IVC) filters; however, caval penetration can also cause unintentional complications. The aim of this study was to assess the incidence, severity, clinical consequences, and management of filter penetration across a range of commercially available IVC filters. Methods and Results— The MEDLINE database was searched for all studies (1970–2014) related to IVC filters. A total of 88 clinical studies and 112 case reports qualified for analysis; these studies included 9002 patients and 15 types of IVC filters. Overall, penetration was reported in 19% of patients (1699 of 9002), and 19% of those penetrations (322 of 1699) showed evidence of organ/structure involvement. Among patients with penetration, 8% were symptomatic, 45% were asymptomatic, and 47% had unknown symptomatology. The most frequently reported symptom was pain (77%, 108 of 140). Major complications were reported in 83 patients (5%). These complications required interventions including surgical removal of the IVC filter (n=63), endovascular stent placement or embolization (n=11), endovascular retrieval of the permanent filter (n=4), and percutaneous nephrostomy or ureteral stent placement (n=3). Complications led to death in 2 patients. A total of 87% of patients (127 of 146) underwent premature filter retrieval or interventions for underlying symptoms or penetration-related complications. Conclusions— Caval penetration is a frequent but clinically underrecognized complication of IVC filter placement. Symptomatic patients accounted for nearly 1/10th of all penetrations; most of these cases had organ/structure involvement. Interventions with endovascular retrieval and surgery were required in most of these symptomatic patients.
Natural History of the Iliac Arteries after Endovascular Abdominal Aortic Aneurysm Repair and Suitability of Ectatic Iliac Arteries as a Distal Sealing Zone
Purpose: To investigate the natural history of dilated common iliac arteries (CIA) exposed to pulsatile blood flow after endovascular abdominal aortic aneurysm repair (EVAR) and the suitability of ectatic iliac arteries as sealing zones using flared iliac limbs. Methods: Follow-up computed tomograms of 102 CIAs in 60 EVAR patients were investigated. Diameter changes in CIAs ≤16 mm (group 1) were compared with changes in vessels where a dilated segment >16 mm in diameter continued to be exposed to pulsatile blood flow (group 2). Within group 2, cases in which the stent terminated proximal to the dilated artery segment (2a) were compared with those that had been treated with a flared limb (2b). Results: The mean CIA diameter increased by 1.0±1.0 mm in group 1 (p<0.001 versus immediately after EVAR) and by 1.5±1.7 mm in group 2 (p<0.001 versus immediately after EVAR) within an average follow-up of 43.6±18.0 months. Diameter increase was more pronounced in dilated CIAs (p=0.048), and it was not significantly different between groups 2a and 2b (p=0.188). No late distal type I endoleak or stent-graft migration associated with CIA ectasia was observed. Conclusion: Dilatation of the CIA is significant after EVAR, and it is more pronounced in ectatic iliac arteries. Although ectatic iliac arteries appear to be suitable sealing zones in the short term, continued follow-up is mandatory.
Impact of Gender on the Outcome of Endovascular Aortic Aneurysm Repair Using the Zenith Stent-Graft: Midterm Results
Purpose: To analyze the 2-year outcomes of female patients after endovascular aortic aneurysm repair (EVAR) with the Zenith AAA Endovascular Graft. Methods: A retrospective analysis was conducted of data from the US Zenith multicenter trial and the Zenith female registry on 40 women (10.9%, study group) and 326 men (89.1%, control group) enrolled. All patients had completed their 2-year follow-up. Primary study endpoints were survival, aneurysm rupture, and conversion rate. Significance was assumed if p<0.05. Results: Overall rates of mortality (12.5% for women versus 13.2% for men, p=0.94) and aneurysm rupture (2.5% for women versus 0% for men, p=0.11) were comparable between groups. Conversion to open repair within 2 years was significantly more frequent in women compared to men (7.5% versus 0.6%, p=0.01). The incidence of endoleaks of any type was equivalent between groups at 2 years (13.3% for women versus 6.9% for men, p=0.30). No difference was observed in the need for secondary interventions (15% for women versus 13.5% for men, p=0.81) or aneurysm dilatation >5 mm (10.5% for women versus 2.3% for men, p=0.10). None of the patients developed device migration .10 mm or required intervention for migration. Conclusion: While women underwent conversion to open repair more frequently compared to men at 2 years post EVAR, there was no difference in survival, freedom from aneurysm rupture, or need for secondary interventions between groups. As in men, the Zenith AAA Endovascular Graft provides reliable protection from aneurysm rupture and aneurysm-related death in women in a midterm follow-up.
Use of Proximal Aortic Cuffs as an Adjunctive Procedure during Endovascular Aortic Aneurysm Repair
The purpose of this study was to evaluate the incidence and durability of additional proximal cuffs during endovascular abdominal aortic aneurysm repair (EVAR). A retrospective review of 90 EVAR patients was conducted. Postoperative survival, proximal sealing zone–related complications, and secondary procedures were analyzed. Additional proximal cuffs were used in 11%. Their use did not affect postoperative survival ( p = .58), type I endoleak rate (4.4%; p = .19), or the need for sealing zone–related secondary procedures (6.3%; p = .38) compared with patients without cuff placement but was related to a higher cumulative graft migration rate (2.2% overall p = .02). Two patients (2.5%; p = .79) underwent conversion to open surgery, both for proximal sealing zone–related complications. Application of proximal cuffs appears to be an effective intraoperative adjunctive procedure to achieve a proximal seal during EVAR, with favorable midterm results. However, the risk of late endograft migrations may be elevated in this group.
Long-Term Results of Endovascular Aneurysm Repair with Aortouni-iliac Custom-Made Stent Grafts
The purpose of this study was to review the outcome of endovascular abdominal aortic aneurysm repair (EVAR) using custom-made aortouni-iliac (AUI) devices with femorofemoral bypass. Between June 1999 and March 2001, 23 consecutive patients (1 female, 22 male) at high risk of open aortic aneurysm repair underwent EVAR with custom devices in an AUI configuration. The mean follow-up was 37 months (range 2–72 months), and the mean age was 76.8 years (range 67.5–88.7 years). Increased surgical risk was evidenced by 92% and 69% of patients with significant pulmonary or cardiac disease, respectively. The preoperative mean aneurysm diameter ( n = 23) 62 ± 8.2 mm was significantly greater than the postoperative diameter, ( n = 23) 54 ± 16.4 mm. Ten endoleaks occurred. Migration of the stent graft occurred in 9% ( n = 2). Secondary interventions were necessary in 23%, whereas tertiary interventions were required in 9%. Patients at high risk of open aneurysm repair received sufficient protection from aneurysm rupture with custom-made AUI devices.
Femoral Incision Morbidity Following Endovascular Aortic Aneurysm Repair
Currently available aortic stent-grafts require bilateral femoral incisions for device deployment. The incidence of morbidity (infection, lymphatic complications, breakdown) of vertical, infrainguinal incisions used in endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAAs) was assessed, and the natural history of asymptomatic groin fluid collections following such procedures was determined. Between June 1999 and February 2001, 77 consecutive patients underwent EVAR for AAAs utilizing bilateral vertical femoral incisions. Fifty-nine (77%) bifurcated stent-grafts (BSGs), and 18 (23%) aortouniiliac (AUI) devices, with femorofemoral bypass were performed. Patients returned at 2 weeks, 1 month, and 6 months for physical examination, and 1 month and 6 months for abdominal and pelvic computed tomography (CT) scans. The presence of fluid collections was determined from the dictation report of the attending radiologist. Data are reported as (n) mean ± SE. Patient characteristics were compared using Fisher's exact test; p <0.05 considered significant. There were 72 males and 5 females, age 75 ±6.4 years and aneurysm size (77) 5.6 ±0.8 cm. There were no cases of wound breakdown or lymph fistula. Wound infections occurred in 3/150 incisions (2%), 2/34 AUI incisions (6%), and 1/1 16 BSG incisions (0.86%). There was no statistical difference (p =0.13) between graft types (BSG vs AUI). All infections were diagnosed clinically before the 1-month CT scan, treated without operative intervention or hospitalization, and resolved. There was a significant decrease in the BSG group and overall in asymptomatic wound fluid collections from 1 to 6 months postoperatively. At 1 and 6 months, respectively, the BSG group had 17 (14.6%) and 3 (2.6%) fluid collections out of 116 incisions (p = 0.003); the AUI group had 6 (17.6%) and 1 (2.9%) fluid collection(s) out of 34 incisions (p = 0. 13); and overall 23 (15.3%) and 4 (2.6%) out of 150 incisions (p = 0.004). The present study demonstrates that bilateral vertical femoral incisions used in EVAR have a wound infection rate of 2.0%. Infections are usually detected and treated clinically and empirically without the need for hospitalization or surgery. Asymptomatic groin wound fluid collections resolve significantly within 6 months without intervention. Therefore, surgical femoral artery exposure adds little morbidity to the endovascular repair of abdominal aortic aneurysms.
Surgical and Interventional Visceral Revascularization for the Treatment of Chronic Mesenteric Ischemia—When to Prefer Which?
AbstractBackgroundThe purpose of the present study was to compare surgical and endovascular revascularization for chronic mesenteric ischemia (CMI).MethodsForty‐nine patients underwent surgical (SG) or endovascular (EG) treatment. Relief of symptoms was considered the primary endpoint; patency, morbidity, and mortality were secondary endpoints. For statistical analysis, significance was assumed if P values ≤ 0.05.ResultsTwenty‐six patients (53%) underwent surgical revascularization; 23 patients (47%), endovascular repair. Mean follow‐up was 25 ± 21 months (SG) versus 10 ± 10 (EG) months (P = 0.07). Except for body mass indices (SG 18.9 ± 2.7 versus EG 23.6 ± 4.8; P = 0.001), preoperative data were comparable. Freedom from symptoms was 100% (SG) versus 90% (EG) after intervention (P = 0.194), and 89% (SG) versus 75% (EG) at the end of follow‐up. Reocclusion or re‐stenosis occurred in 8% (SG) versus 25% (EG) (log‐rank test: P = 0.003), and mesenteric ischemia developed in 0% (SG) versus 9% (EG) (P = 0.04). Reintervention for CMI was required in 0% (SG) versus 13% (EG) (P = 0.01). Surgical patients experienced more early complications (42% versus EG 4%; P = 0.02) and longer hospital stays (11.6 ± 10.9 days versus EG 1.3 ± 0.5 days; P < 0.001). Overall mortality at the end of follow‐up was 31% (SG) versus 4% (EG) (log‐rank test: P = 0.08), including all patients with combined open mesenteric and aortic reconstruction (P = 0.001).ConclusionsSurgical treatment has superior long‐term patency and requires fewer reinterventions, but it is also more invasive with greater morbidity and mortality compared to endovascular treatment. Endovascular techniques may be preferable in patients with significant co‐morbidities, concomitant aortic disease, or indeterminate symptoms.
Management of a Large Intraoperative Type IIIb Endoleak in a Bifurcated Endograft
The purpose of this paper is to describe the intraoperative management of a type IIIb endoleak after deployment of a bifurcated endograft in a patient with narrow iliac access vessels. A 62-year-old man underwent elective endovascular repair (EVAR) of a 53 mm abdominal aortic aneurysm. After device deployment, a large IIIb endoleak, arising from the main body of the device, was visualized. Narrow iliac vessels precluded deployment of a second bifurcated graft, and the endoleak was successfully excluded with an aortomonoiliac device, followed by contralateral iliac occlusion and subsequent creation of a femorofemoral bypass. At 1-year follow-up, the aneurysm remains excluded and is decreasing in size. Type III endoleaks are a known complication of EVAR, requiring immediate treatment through their association with aneurysm enlargement and rupture. If an additional bifurcated graft cannot be used, aortomonoiliac conversion represents a feasible endovascular alternative treatment for type III endoleaks, other than conversion to open surgical repair. Therefore, aortomonoiliac converters with appropriate occluder devices should be readily available during deployment of bifurcated devices.