The purpose of this study was to evaluate the incidence and durability of additional proximal cuffs during endovascular abdominal aortic aneurysm repair (EVAR). A retrospective review of 90 EVAR patients was conducted. Postoperative survival, proximal sealing zone–related complications, and secondary procedures were analyzed. Additional proximal cuffs were used in 11%. Their use did not affect postoperative survival ( p = .58), type I endoleak rate (4.4%; p = .19), or the need for sealing zone–related secondary procedures (6.3%; p = .38) compared with patients without cuff placement but was related to a higher cumulative graft migration rate (2.2% overall p = .02). Two patients (2.5%; p = .79) underwent conversion to open surgery, both for proximal sealing zone–related complications. Application of proximal cuffs appears to be an effective intraoperative adjunctive procedure to achieve a proximal seal during EVAR, with favorable midterm results. However, the risk of late endograft migrations may be elevated in this group.
A Comparison of AneuRx Aortic Cuff and Zenith Distal Flare Exclusion of Common Iliac Artery Ectasia for Endovascular Aneurysm Repair
Stent-grafts are ideally terminated within the common iliac artery (CIA). However, CIA ectasia may require hypogastric artery occlusion, with stent-graft extension to the external iliac artery. Alternatively, the diameter of the distal stent-graft may be increased, or flared, to allow exclusion of the abdominal aortic aneurysm. This report details the authors’ experience with this technique. Forty-one patients received bifurcated stent-grafts (BSG): 20 received an AneuRx device, and 21 received a Zenith device. CIA ectasia (diameter 15–25 mm) was treated with a distal flare of 2–4 mm greater than the CIA diameter. Patients were followed up with computed tomography scan at 1, 6, and 12 months. Statistical analysis was performed using ANOVA within groups and unpaired two-tailed t test between groups. A p value of <0.05 was considered significant. Eight of 20 patients (40%) (11 CIA) received an AneuRx device and 13/21 (62%) (17 CIA) received a Zenith device, with a distal flare. Values are (n) mean (mm) ± SE. There were no deaths, endoleaks, migrations, or conversions to open repair. Follow-up mean was 24.7 and 20.6 (range 15–28) months for AneuRx and Zenith groups, respectively. In comparing initial and 12-month CIA diameters, AneuRx grafts 20 ±0.8 vs 21.5 ±1.0 were not significantly different, p= 0.2, nor was the same comparison for Zenith, 17 ±0.5 vs 19.1 ±0.4, significant, p= 0.57. At a mean follow-up of 12 months, distal flare of iliac limbs with either AneuRx or Zenith devices affords a seal for CIA ectasia and/or aneurysms complicating EVAR.