The aim of this study was to determine the maximal aneurysm diameter (MAD), the total aneurysm volume (TAV), the intra-aneurysm vascular channel (IAVC), and total thrombus volume (TTV) and compare changes in those parameters during a 12-month time period. In addition, these parameters for three different endovascular grafts were compared. A retrospective review of 42 patients who had undergone endovascular aneurysm repair (EVAR) between July 1999 and March 2001, and without evidence of an endoleak or migration, was performed. The minimum follow-up in this group was 12 months. The three grafts deployed were Dacron-stainless steel bifurcated grafts with suprarenal fixation [Zenith; Cook, Inc. ( n = 14)], Dacron stainless steel aorto uni-iliac grafts with suprarenal fixation [custom-made ( n = 10)], and externally supported Dacron nitinol bifurcated grafts [AneuRx; Medtronic, Inc. ( n = 18)]. Volumetric measurements were obtained from CT images performed preoperatively, at 1 month and 12 months thereafter, using a 3-D Magicview 1000 workstation (Siemens, Inc.). Regardless of the type of endograft, a significant Change in MAD and TAV ( P = 0.008), IAVC ( P = 0.031), and TTV ( P = 0.001) was observed over the 12-month postoperative period. Both maximum diameter and total aneurysm volume appear to reflect accurately successful aneurysm exclusion. We conclude that both two-dimensional, maximal aneurysm diameter and three-dimensional, total aneurysm volume accurately reflect changes in morphology after endovascular aneurysm repair.
Polyester vs. Bovine Pericardial Patching during Carotid Endarterectomy: Early Neurologic Events and Incidence of Restenosis
Purpose The aim of this report was to compare polyester vs. bovine pericardial patching during CEA with regards to the incidence of early neurologic events and recurrent stenosis. Patients and methods One hundred and twenty-five consecutive patients with high grade symptomatic (14%) or asymptomatic (86%) carotid artery stenosis (>70%) who underwent 139 CEAs by a single surgeon between January 1997 and April 2001 were retrospectively reviewed. Patients were assessed postoperatively clinically and with routine follow-up duplex scanning. Recurrent stenosis was defined as a narrowing in the common or internal carotid artery of more than 50% by duplex ultrasound examination. Results From January 1997 to May 1999, a polyester patch was routinely used in 81 (58%) patients, while between June 1999 and April 2001, a bovine pericardium patch was exclusively used in 59 (42%) patients. There were no ipsilateral postoperative TIAs or strokes in either group. The combined 30-day mortality rate for both groups was 0.8%. One patient in the polyester patch group died from cardiopulmonary complications 10 days after discharge. The length of follow-up in the bovine pericardial patch group was 3–28 months (mean 12 months), while in the polyester patch group was 1–50 months (mean 24.5 month). One patient developed a carotid pseudoaneurysm of the suture line in the bovine pericardium patch group caused by a local infection after previous neck dissection and radiation. The incidence of recurrent stenosis was two patients (4%) in the bovine pericardium group as opposed to six patients (7.6%) in the polyester patch group. Conclusion Although this is a preliminary report, it is concluded that bovine pericardium provides excellent perioperative results and is at least comparable to polyester patching in terms of safety. Our study with short term follow up suggests that bovine pericardium patching during carotid endarterectomy may have a lower restenosis rate compared to knitted polyester patching. Clear superiority of bovine pericardium as a patch material awaits a prospective randomised study with long-term follow-up.
Natural History of the Iliac Arteries after Endovascular Abdominal Aortic Aneurysm Repair and Suitability of Ectatic Iliac Arteries as a Distal Sealing Zone
Purpose: To investigate the natural history of dilated common iliac arteries (CIA) exposed to pulsatile blood flow after endovascular abdominal aortic aneurysm repair (EVAR) and the suitability of ectatic iliac arteries as sealing zones using flared iliac limbs. Methods: Follow-up computed tomograms of 102 CIAs in 60 EVAR patients were investigated. Diameter changes in CIAs ≤16 mm (group 1) were compared with changes in vessels where a dilated segment >16 mm in diameter continued to be exposed to pulsatile blood flow (group 2). Within group 2, cases in which the stent terminated proximal to the dilated artery segment (2a) were compared with those that had been treated with a flared limb (2b). Results: The mean CIA diameter increased by 1.0±1.0 mm in group 1 (p<0.001 versus immediately after EVAR) and by 1.5±1.7 mm in group 2 (p<0.001 versus immediately after EVAR) within an average follow-up of 43.6±18.0 months. Diameter increase was more pronounced in dilated CIAs (p=0.048), and it was not significantly different between groups 2a and 2b (p=0.188). No late distal type I endoleak or stent-graft migration associated with CIA ectasia was observed. Conclusion: Dilatation of the CIA is significant after EVAR, and it is more pronounced in ectatic iliac arteries. Although ectatic iliac arteries appear to be suitable sealing zones in the short term, continued follow-up is mandatory.
Use of Proximal Aortic Cuffs as an Adjunctive Procedure during Endovascular Aortic Aneurysm Repair
The purpose of this study was to evaluate the incidence and durability of additional proximal cuffs during endovascular abdominal aortic aneurysm repair (EVAR). A retrospective review of 90 EVAR patients was conducted. Postoperative survival, proximal sealing zone–related complications, and secondary procedures were analyzed. Additional proximal cuffs were used in 11%. Their use did not affect postoperative survival ( p = .58), type I endoleak rate (4.4%; p = .19), or the need for sealing zone–related secondary procedures (6.3%; p = .38) compared with patients without cuff placement but was related to a higher cumulative graft migration rate (2.2% overall p = .02). Two patients (2.5%; p = .79) underwent conversion to open surgery, both for proximal sealing zone–related complications. Application of proximal cuffs appears to be an effective intraoperative adjunctive procedure to achieve a proximal seal during EVAR, with favorable midterm results. However, the risk of late endograft migrations may be elevated in this group.
Long-Term Results of Endovascular Aneurysm Repair with Aortouni-iliac Custom-Made Stent Grafts
The purpose of this study was to review the outcome of endovascular abdominal aortic aneurysm repair (EVAR) using custom-made aortouni-iliac (AUI) devices with femorofemoral bypass. Between June 1999 and March 2001, 23 consecutive patients (1 female, 22 male) at high risk of open aortic aneurysm repair underwent EVAR with custom devices in an AUI configuration. The mean follow-up was 37 months (range 2–72 months), and the mean age was 76.8 years (range 67.5–88.7 years). Increased surgical risk was evidenced by 92% and 69% of patients with significant pulmonary or cardiac disease, respectively. The preoperative mean aneurysm diameter ( n = 23) 62 ± 8.2 mm was significantly greater than the postoperative diameter, ( n = 23) 54 ± 16.4 mm. Ten endoleaks occurred. Migration of the stent graft occurred in 9% ( n = 2). Secondary interventions were necessary in 23%, whereas tertiary interventions were required in 9%. Patients at high risk of open aneurysm repair received sufficient protection from aneurysm rupture with custom-made AUI devices.
Paravertebral Blockade with Propofol Sedation versus General Anesthesia for Elective Endovascular Abdominal Aortic Aneurysm Repair
The objective of this study was to evaluate the applicability of paravertebral blockade (PVB) for endovascular abdominal aortic aneurysm repair compared with general anesthesia (GA). Data from patients who underwent elective infrarenal endovascular abdominal aortic aneurysm repair between August 2001 and July 2002 using PVB or GA were retrospectively reviewed and compared with respect to risk factors, intraoperative hemodynamic characteristics, operative outcome, and complications. Ten patients underwent elective infrarenal endovascular abdominal aortic aneurysm repair under PVB, whereas 15 patients were operated on under GA. One conversion from PVB to GA was necessary for block failure. The perioperative (< 30 days) cardiovascular morbidity and overall mortality were zero in both groups. The PVB group benefited significantly with respect to the incidence of intraoperative hypotension ( p < .05) and blood pressure lability ( p < .01), as well as postoperative nausea ( p < .01). Our preliminary results indicate that PVB is feasible and can be performed safely in a patient population with significant comorbidities.
A Comparison of AneuRx Aortic Cuff and Zenith Distal Flare Exclusion of Common Iliac Artery Ectasia for Endovascular Aneurysm Repair
Stent-grafts are ideally terminated within the common iliac artery (CIA). However, CIA ectasia may require hypogastric artery occlusion, with stent-graft extension to the external iliac artery. Alternatively, the diameter of the distal stent-graft may be increased, or flared, to allow exclusion of the abdominal aortic aneurysm. This report details the authors’ experience with this technique. Forty-one patients received bifurcated stent-grafts (BSG): 20 received an AneuRx device, and 21 received a Zenith device. CIA ectasia (diameter 15–25 mm) was treated with a distal flare of 2–4 mm greater than the CIA diameter. Patients were followed up with computed tomography scan at 1, 6, and 12 months. Statistical analysis was performed using ANOVA within groups and unpaired two-tailed t test between groups. A p value of <0.05 was considered significant. Eight of 20 patients (40%) (11 CIA) received an AneuRx device and 13/21 (62%) (17 CIA) received a Zenith device, with a distal flare. Values are (n) mean (mm) ± SE. There were no deaths, endoleaks, migrations, or conversions to open repair. Follow-up mean was 24.7 and 20.6 (range 15–28) months for AneuRx and Zenith groups, respectively. In comparing initial and 12-month CIA diameters, AneuRx grafts 20 ±0.8 vs 21.5 ±1.0 were not significantly different, p= 0.2, nor was the same comparison for Zenith, 17 ±0.5 vs 19.1 ±0.4, significant, p= 0.57. At a mean follow-up of 12 months, distal flare of iliac limbs with either AneuRx or Zenith devices affords a seal for CIA ectasia and/or aneurysms complicating EVAR.